2005-715 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
4z Community Development- Building &Codes (518) 761-8256
CERTIFICATE (J""F COMPLIANCE
Permit Number. P20050715 Date Issued: Friday, November 03, 2006
This is to certify that work requested to be done as shown by Permit Number P20050715
has been completed.
Tax Map Number. 523400-290-005-0001-013-000-0000
Location: 65 SUNNYSIDE Rd
Owner. ROBERT & GAIL HUNTZ
Applicant: ROBERT & GAIL HUNTZ
This structure may be occupied as a:
Porch
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: P20050715 Application Number: A20050715
Tax Map No: 523400-290-005-0001-013-000-0000
Permission is hereby granted to: ROBERT & GAIL H[NTZ
For property located at: 65 SUNNYSIDE Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Tyne of Construction Value
Owner Address: ROBERT & GAIL HUNTZ Porch $10,000.00
65 SUNNYSIDE Rd Total Value $10,000.00
QUEENSBURY,NY 12804
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2005-715
320 SQ FT PORCH
$40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday, September 19, 2006
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the T 7:!,ueens 1V�o ay, September 19, 2005
SIGNED BY for the Town of Queensbury.
Director of Building K Code nforcement
No. c���J�
Building&Codes Office-Department of Community Development-Town of Queensbury Permit /Fee Paid
742 Bay Road,Queensbury,NY 12804
Dave Hatin,Director codesQaueensbury.net
Phone: (518) 761-8256 FAX: (518) 745-4437
Accessory Structure Building Permit Application
Application & Plans subject to review before issuance of a valid permit for construction
Any structure other than the principal structure (i.e., house), typically a garage, shed, greenhouse, dock, deck,
etc. (not necessarily limited to the list below). Refer to attached Informational Brochure No. 3
Instructions: A permit must be obtained before beginning construction. No inspections,will be made until the
applicant has received a valid building permit. All applicants' spaces on this application must be completed and
must appear on the application form.
Applicant/Builder Owner: P 6/ ���•�T z
Address: Address: !S".3°�: �,✓r,'r f1 ,
�rA14 /,?8a
Home Phone: Home Phone: / '-7 I s-r
Email Address: Email Address: e 4 Vz (0-J Ab_�h . cat,
Cell Phone: Cell Phone:
FAX Phone: FAX Phone:
Person responsible for supervision of work withrespect to building and codes orripliance:,.
Name: m er Y �, ct Lr
Address: SQ1"-4 _C )CAf Rd, A ne
Location of proposed construction: Lot No. Legal Address: s1�{ 14
I
Tax Map Number:� �s f � � Subdivision Name: a ipt�%ew
Estimated Cost of Construction: $ /C9 O a0
Does an accessory structure currently exist on the property Yes / _No
If YES, list all existing accessory structures: 3 .repe.�m4_ ye3ee4
Proposed Construction 1-f floor 2nd floor Total Proposed Height
sq.ff. sq.ff. Sq.ft. ft.&
Open Porch
Covered or Enclosed Porch
(considered floor area&must comply to FAR [Floor Area Ratio]
requirements if the structure is located in the Waterfront
Residential zone.
3-season porch is considered an enclosed porch.
Deck
Boathouse
Boathouse with sundeck
DOCK
Shed
Pole Barn
Detached Garage 1, 2, 3 car
Other Accessory Structure:
Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review.
The Building and Codes Office will allow commencement of your proposed project only after
issuance of your permit.
Declaration: Please sign below after you have carefully read the statement:
To the best of my knowledge, the statements contained in the application, together with the plans and
specifications submitted, are a true and complete statement of all proposed work to be done on the described
premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the
proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner.
Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance
being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a
licensed surveyor, drawn to scale, showing actual location of all new con truction.
Date: 3% Applicant/Builder Signature:
The application of dated is hereby approved and:
permission granted for the construction, reconstruction or alteration of a building/and or accessory structure as set
forth above.
Date:911 Authorized Signature: _ "
L:\Sue Hemingway\Building.Permit.FORMS\Accessory Structure Permit Application.doc V:12/28/04
12-/0(�
` Queensbury Building & Code Enforcement - Residential Final Inspection
Office No.(518)761-8256 Arrive: mn �epa�rt: am/pm
Date Inspection request received: Inspector's Initials: !�
NAME: PERMIT#:
LOCATION: 2 a nst4 DATE:
TYPE OF STRUCTURE:
Comments
Yes No NIA
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location GFresh Air Intake i2c— '`
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Com lete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porcbes 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy!trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s . 1-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Tra /Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%s"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/o hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O[Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form—revised—I 00405.doc
L f- r1 moll�bAy.
Queensbury Building & Code Enforcement Oitials:
Residential Final Inspection
Office No. (518)761-8256 Arrive: am/prr� t: ' am/pm
Date Inspection request received: Inspect 's I �}
NAME: PERMIT#: --
LOCATION: J DATE: /
TYPE OF STRUCTURE:
Comments
Yes No N/A
Building Number/Address visible from road ] //V
ChimneyHeight/"B"Vent/Direct Vent Location LJ
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Com lete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy!trim/doors/main entrance 36 inches
Bathroom/Kitchen waterti ht
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s . ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Tern 110
Enclosed Stairs Sheetrock Underside minimum%s"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O Temporary/Permanent)
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc
Queensbury Building & Code Enforcement - Residential Final Inspection
i
O ice No. (518)761-8256 Arrive: am/pm Depart: am/pm
Dat •nspection request received: Inspect 's Initials: 4�
NAME: O PERMIT#: -77
LOCATION: /2 DATE:
TYPE OF STRUCTURE:
Comments
Yes No NIA
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
------d T
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches /
Interior Handrails stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate 7� �
Gas Valve shut-off exposed/regulator 18 inches above grade l
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Batterybackup:
Carbon Monoxide Detector W,06- ��Attic access 30 inches x 22 inches x 30 inches(hei ht)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .1-150 s .ft.vents
Bathroom Fans,if no window �j F �� ^ ),. 'N
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%s"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/Y4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O[Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc
-,� -TOSS 6 _ 13 06
Foundation Inspection Report
Office No. (518)761-8256 Date Ins do equest received: '6 — /3 —D 6
Queensbury Building&Code Enforcement Arrive: r p Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspect is Initials:
NAME: h�Z PERMIT#:
LOCATION: r INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10$.
L:\Building&Codes Forms\Building&CodeWnspection Forms\Foumwo►►Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
J-ay P."'I'O Vd
f/aS
a..jai✓p� �
r � [�
� 21Y,2-7
V7
19
77.1
L6 '6L S' n1
17N/7 -- -
rig
Jj
W
�r
1
-e C) N OF QUaENSBURY
-T,
_ DEP
54
PULDiNG & CODAS
REVItVE
- 6 4
E
Fllw F (4`; P t
(el
THIS PL N TO BE ON
N To BE 0'
PROJE SITE AT 1119
S FOR
ALL FOR 0 F
T�E- DRAT OF
C ST tjCTI RE C`OPY
ONSTRUCTI
bA^'
N .-+
o41
r O
EXISTIN& FRONT 13'-0'PLAN 2-2XIO PT (PRIMARY BEAM) 2XI0 SKIRT
SCALE: 1/4"=I'-O" 5/4X& PT gyp`
DECKING PORCH ,��-2XI PT ,@ 16 OG
i= Q
(SECONDARY BEAM) Z
STONE GAP
SECONDARY F—+
STONE BEAMS U
VENEER CANTILEVER
OVER
GMU COLUMN PRIMARY
40' 3" BEAM
z
PROF05ED FORGH FRAMIN&
PLAN
SCALE: 1/4"=I'-O" -�
V �° o
j
,
DowN PORCH
4
LLUO 2w
Li U
Foo ❑ ❑ ❑ ❑
44'-3'
40'-3N
EX15TIN6 FRONT ELEVATION EXISTINO -SIDE ELEVATION - PROP05ED PORC4H PLAN
SCALE: 1/4"=I'-O" (D 5GALE: 1/4"=I'-O" (D!SCALE: 1/4"=I'-O"
FACE EXISTING
CHIMNEY IN
STONE VENEER
— TO MATCH PORCH PILLARS
!_
� i
rc> S�
I� hce e44 C)
NOTES:
1. METAL 5TAND I NG 5EAM
Q
4 12D ROOFING : COLOR Ti3D � P
2. ELDOR4DO STONE VENEER: FILE �-R� �
Y [�
STYLE TBD w
Ln METAL i"x V-GROOVE 3. R I L I NG - TOP RAIL AND
p
STANDING SEAM PINE DECKING p
FOR RooF 6 p BOTTOM RAIL lk4x3 W/ I x I
\ E3ALLU5TER5
4. DESIGN CRITERIA - 70 LB �r
SNOW LOAD AND QO LB WIND S_
� ROUGH GUT PULL LOAD
8X8 YV/ 2X,5 ® lb" OG
- PRESSURE
TREATED SILL I �1
_ _ 2" STONE
- GAP RAILING AT
- - - 36" HIGH TOWN OF QUEENSBURY
0 -
--_ _
BUILDING & ODES DEPT. 0-4 a
REVIEWE BY W
IL FINISHED FLOOR
DECK SURFACE - DATE l t
2XIO LEDGER
w 43 0' " 8'-0" BOARD
0 .. 4 4'
b, �� ,, n PORCH
0
44'-3' a
/ � illas Vt'i�1tcL*,zC, �SY � L�t{ r `,�I Ci`iI
d r� r Da$ed on our vomited examination,
conppliance,.,Mh our comments$ha'! DRAWINGS
o not be cen$rued as inoica:ing the
PROP 0 5 E D FRONT ELEVATION I=10 plans and spec catnaps are in Ball
o comp!�ance with.the Building Codes
of Now York State. DATE
PROP05LD 51 DE ELEVATION G N0_DWG. . 6-05
N 5GALE: 1/4"=I'-O"
SCALE: 1/4"=I'-O" 1
JOB NO.