Loading...
blower door resultsTesting Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:5 Apres Address:5 Apres Circle Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.282079 Longitude: -73.722197 Timestamp: 2020-12-08 07:29:40 Customer Information: Name:Cerrone Builders Inc Address: Measured Leakage:1,044.9 CFM50 Test ID:5 Apres Purpose of Test:50 Pa Env. Leakage Measured ACH50:2.08 Effective Leakage Area: 57.5 in² Building Volume:30,192.0 ft³Enclosure Surface Area: 4,276.0 ft² Coefficient (C):82.2 Exponent (n): 0.650 (assumed) Test Standard:RESNET 380 One-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 62 °F Altitude: 420.0 ft Outdoor Temp: 26 °F Time Average Period: 10 seconds Test Date and Time:2020-12-08 07:42:26 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -2.7 -50.0 -51.4 -48.7 -36.4 1,097.2 Ring A Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3173 Custom Calibration Date: 2020-02-10 Pressure Gauge:DG1000 Serial #: 5193 Calibration Date: 2020-01-16 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.7.3 (91), © 2020 The Energy Conservatory, Inc.