Loading...
Application S At the direction of the Planning Board Chairman on 10/1/01, please note the following message - "The Planning Board will not accept additional information during the applications review. Additional submissions will result in the application being tabled for further staff and engineering review." Applicant Name James J. Grande Tax Map No. 239.18 - 1 - 48 Zonng Classification WR - 3A APA,CEA Zoning Ordinance Compliance Section: 179-4-010 C6: table 4; & 179-5-090 minimum floor area DESCRIPTION OF PROJECT: Construction of garage with attached cottage in lieu of existing cottage; cottage will then be in compliance with setbacks; garage is fully in compliance. PRE-APPLICATION y MEETING NOTES: / �II�,i7 � �IL1ht wY'p�µ^J� 1'°r S✓�1.�w�^^^ u " tq Z Date(s)of Pre-Application Conference I Applicant Initials y Staff Member Initials Nothing stated in this meeting is to be construed as an approua.l or disapproual. The sole intent of the pre-application meeting is to address submission requirements and to identify potential concerns. All content of subnaission,s is the responsibility of the applicant or authorised designee. Area Variance Last Revised: 04/16/2002 / General Information Application No. (Office Use Only) Project Location: 3222 Rt. 9L Lake George NY Tax Map ID: 239.18 - 1 - 48 Zone Classification: WR - 3A Compliance with Zoning Ordinance Section: Detailed Description of Project: (include current& proposed use): Construction of garage with attached cottage in lieu of existing cottage; cottage will then be in compliance with setbacks; garage is fully in compliance Applicant: James J. Grande Address: 3222 Rt. 9L Lake George NY 12845 Home Phone: 668-4628 Work Phone/Fax: 584-5940 FAX 581-1945 Applicant's Agent: Michael J. O'Connor Address: Little & O'Connor PO Box 898, Glens Falls, NY 12801 Home Phone: 793-3387 Work Phone/Fax: 792-8728 FAX 792-6972 Property Owner: James J. Grande Address: 3222 Rt. 9L Lake George NY 12845 Home Phone: 668-4628 Work Phone/Fax: 584-5940 FAX 581-1945 Directions to Site: Go to the North end of Bay Rd. Turn left on Rt. 9L go ' mile turn right (first driveway past Cedar Points) Area Variance Last Revised: 04/16/2002 Site Development Data Area/Type Existing sq. ft. Proposed Addition Total sq. ft. so. ft. A.Building Footprint 1350t 1350 B. Detached Garage 892 892 C. Accessory Structure(s) cabin 400± 382 382 shed 48 D. Paved, gravel or other hard surfaced areas 10,000± 1500 11,500 E. Porches/Decks 650± 650 F. Other Total Non-Permeable Sum A through F 12,448 14,774 Parcel Area 142,441 142,441 Percent Non-Permeable (Total Non-Permeable/Parcel 8,7% 10.1% Area Setback Requirements Required Existing Proposed Front(l) Front(2) Shoreline 75 house 65' garage 126'6" Side Yard 1) 25 cabin 22.7' cabin 33'± Side Yard 2) 25 garage 185'± Rear Yard(1) Rear Yard(2 Buffer/Travel Corridor Height Permeability Sign Setback No. of Parking Spaces Area Variance Last Revised: 04/16/2002 3 FLOOR AREA RATIO WORKSIIEET Any construction,addition or replacement of structures in the Waterfront Residential Zones(WR-lA &WR- 3A) is subject to the Floor Area Ratio requirements as defined in Section 179-16 of the Town of Queensbury Zoning Ordinance. Floor Area Ratio (FAR) is the relationship of building size to lot size derived by dividing the total building square footage by the lot size in squarc feet, yielding a percentage. The maximum allowable FAR is 22 percent. *#Please note that FAR requirements are separate and distinct from the permeable area requirements that may apply. Building square footage includes all floors of the primary structure,covered porches,and basements(when at least three (3) feet in height of one (1) wall is exposed and the space meets the living space requirements as defined in Section 711 and 712 of the NYS Building Code — see reverse side of pace. Detached storage buildings greater than 100 sq. It. and detached garages are so included in the FAR calculations. Building square footage does not include: open decks, docks and that portion of covered docks extending into the water,and one shed 100 sq. ft.or less. All additional sheds arc included in the FAR calculations. Use/Location Existing Area (sq. ft.) Proposed Area (sq, ft.) Primary Ilouse First Floor 13 + Second floor 1500± Basement(living space) 0 Covered or enclosed porches 1st & 2nd floor 785— Covered decks 0 Guest House 400_ to be Apartment removed existing Detached Garage(s) 892 Shed(I shed 100 sq. ft.or less exempt) Covered Dock or Boathouse(portion on land) Other(describe): A. Lot area: Acres x 43,560= 142,441 B. Total Allowable Floor Area=A x.22 31.337 C. Existing Floor Area;Total from above lines 4035 D. Remaining Area:potentially developable=B minus C 27 302 E. Proposed Area of Construction 892 *** If E is larger than D, a variance or revisions to your plan may be needed. Please consult witli Staff. Area Variance Last Revised: 04/16/2002 Compliance with Zoning Ordinance Section requesting relief from 179-4-010 C6; table 4• & 179-5-090 minimum floor area Require(s): OSetback, OLot Width, OBufferZone, DOther that can not be met by the project as proposed. Specific requirements should be provided on the site development data sheet. • - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - The following questions reflect the criteria for granting this type of variance. Please complete them, using additional sheets if needed. 1. How would you benefit from the granting of this Area Variance? A pre-existing non-conforming condition would be brought into compliance for setback. Number of accessory buildings would be decreased. 2. What effect would this variance have on the character of the neighborhood and the health,safety, and welfare of the community? Guest cottage already exists so there would be no negative impact on the character of the neighborhood or the health safety and welfare of the community. 3. Are there feasible alternatives to this variance? No - the guest cottage is no being enlarged; it is simply being moved and combined with an otherwise compliant garage. The only alternative would be to remodel niece-meal. where it is, and build a separate garage 4. Is the amount of relief substantial relief relative to the Ordinance? No - a Quest cottage of this size already exists; allowing it to be moved does not create anything new. 5. Will the variance have an adverse effect or impact on the physical or environmental conditions in the neighborhood or district? No - this cabin by nla ement, is not visible from the Lake; given the size and deed restrictions against renting it approval will not affect the density of use .of this Take_ Arca Variance Last Reviscd: 04/16/2002 Checklist-Please prepare a map depicting existing and proposed conditions. Failure to complete ale following checklist or include all the required information on your plot plan will result in a determination of incompleteness and a delay in the processing of your application. *Check/Initial Bach Box P—Provided ADDRESS EACH ITEM NA—Not Applicable WR—Waiver Re acsted GENERAL P NA WR A. Title,name,address of licant& crson res onsiblc for r aration of draw:.. B. North arrow,Tax Ma 1D,date repared and scale minimum 1 in.=40 ft. C. Boundaries of the monerty plotted to scale,zonin bounds i/ D. Location of rinci al structure,accesso structures with exterior dunensions E. Location of site improvements including outdoor storage areas,driveways(existing and ro sod , arkin areas,etc. F. Setbacks for all structures and im rovcnrcnis G. Elevations of ro posed struc\p. &SEWER A. Location of on-site sewage disposal facilities, design details, construction details, 1/ flow rates,and number of bedrooms served. ✓ B. Location of water supply (i.e. well) and septic on adjoining lots with separation distances to exist... or r- osed on-site water su 1 and se itic. C. Sc aration distances for proposed sewage dis sal s tern to well pP(d walerbodics. D. Location and description of existing public or private water su 1 well,lake,etc.). Method of securing Public or private water, location, design and construction of water su 1 includin dail water us; e. E. Percolation test location and results. PARKING/PERMEABLE AREAS A. No.of s aces required for project includin calculations and'ustification. / B. No. of existing parking spaces, no. to be removed, no. to maintain and type of ✓ surfacin material e. ., avel, aced . C. Provision for edestrian and handica access and arkr D. Location ad deli details of in ess,a ess, areas and modon : . E. Location and character of grceu areas(existing and proposed),modification to green area,buffer zone to remain undisturbed. ✓ F. Li htin ,location and deli n of all existnm or ro osed outdoor li htn . ADDITIONAL SITE DEVELOPMENT AND MISCELLANEOUS A. Location of on-sitc&adjacent watercourses:sucams,rivers,lave and wetlands. t� B. Location of proposed & existing: udli /encr y distributions stems (g solar,tcle hone. C. Location, design, mid construction of all existing and proposed site improvements / nmcludumg: drains, culverts, retaining walls, fences, fire & emergency zones and v h drants. (/ D. Location and amount/portion of build ng area proposed for office,manufacturing, retail sales,or other commercial activities. B. Si a e: Location,size,Me,CICSIgn and setback Area Variance Last Revised: 04/16/2002 / (D Signature Page This Page includes the Authorization to Act as Agent Form, Engineering Fee Disclosure, Other Permit Responsibilities,and Agreement to provide documentation required. Complete the following if the OWNER of the property is not the same as the applicant: Owner's Agent Form Owner: (Print Owner Name) Designates: (Print Applicant/Agent Name) As agent regarding: _ Variance _Site Plan _Subdivision For Tax Map No.: Section _ Block_ Lot Deed Reference: Book _ Page_ Date SIGNATURE: (Owner) Date Complete the following if the APPLICANT is unable to attend the meeting or wishes to be represented by another party: Applicant's Agent Form Applicant: James J. Grande (Print Applicant Name) Designates: Michael J. O'Connor (Print Agent Name) As agent regarding: _Variance % Sit Ian �Subdivision For Tax Map No.: on 239,t8 B ck of 4 SIGNATURE: — (Applicant) lam' L'�=Date Engineering Fee Disclosure: Applications may be referred to the Town consulting engineer for review of septic design, storm drainage, etc. as determined by the Zoning or Planning Department. Fees for engineering review services will be charged directly to the applicant. Fees for engineering review will not exceed$1,000 without notification to the applicant Please Note: Other permits may be required for construction or alteration activity subsequent to approval by the Zoning Board and/or Planning Board. It is the applicant's responsibility to obtain any additional permits. Official Meeting Minutes Disclosure: It is the practice of Community Development Department to have a designated stenographer tape record the proceedings of meetings resulting from application,and that minutes transcribed from those tapes constitute the official record of all proceedings. If there is a discrepancy between such record and the handwritten minutes taken by the designated stenographer, the handwritten minutes shall be deemed the official record. I,the undersigned,have thoroughly read and un ersta a ins ctions for submission, agree to the submission requirements and c ted the lice is app ,d Date app e6 agad a• Date Area Variance Last Revised: 04/16/2002 1