RESFINAL-004336-2020 08172020INSPECTION WORKSHEET (RESFINAL-004336-2020)
RC-0132-2020Permit Management
Case Number:Case Module:
08/17/2020Failed
Inspection Date:Inspection Status:
Charles DyerResidential Final Inspection
Inspector:Inspection Type:
295.15-2-3
Job Address:Parcel Number:
36 John Clendon Rd
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantFOOTHILLS BUILDERS, LLC
ContractorFOOTHILLS BUILDERS, LLC
Granted PermissionFOOTHILLS BUILDERS, LLC
Primary OwnerFOOTHILLS BUILDERS, LLC
Checklist ItemPassedComments
Low flow toilet 1.3 gal/flushing cycleFalse
Bathroom Fans, if no windowFalse
3" Plumbing Vent through roof minimum 18 inchFalse
Grade away from foundation: 6" down, 10' outFalse
Final Survey Plot PlanFalse
Sewer Dept. Inspection StickerFalse
Window guards req:<2' above floor/6' above gradeFalse
Interior privacy/trim/doors/main entrance 36False
Backflow Preventors where requiredFalse
Emergency egress below gradeFalse
Fuel Tanks above flood plain elevationFalse
Intake OpeningsFalse
Safety glazing: w/in 5' of tub/showerFalse
Site Plan / Variance requiredFalse
Seals on Garage Doors, esp. WoodFalse
Basement ceiling covered 2x8 fl joist or lessFalse
Attic Access Insulation = Attic R- ValueFalse
Gas Shut-off Exposed & Regulator (18) Above GradeFalse
Platform at all exterior doorsFalse
Smoke Detectors: Carbon MonoxideFalse
Fireblocking at fl joist 80 s.f. or lessFalse
Garage Floor PitchedFalse
Buried Fuel Tanks anchored in flood zoneFalse
Wood deck: 2'+ from grade dia bracing requiredFalse
Inter ConnectedFalse
Arc Fault Breaker Habitable SpacesFalse
Dryer Duct Max Length 35', Labeled Over 35'False
Energy Sticker on Elec. Panel:R-Val. & Heating SysFalse
Furnace/Hot Water Heater operatingFalse
Fresh Air IntakeFalse
Chimney Rain Cap InstalledFalse
December 21, 2020Page 1 of 3
INSPECTION WORKSHEET (RESFINAL-004336-2020)
Checklist ItemPassedComments
Basement stairs closed rise greater than 4 inchesFalse
Outside every bedroom areaFalse
Oil Furnace Shut-Off at Entrance to Furnace AreaFalse
Blower Door Test CertificationFalse
Fin ElectEnergy Saving Light Bulbs 50 PercentFalse
Gas Log In Sealed or Glass EnclosureFalse
OK to Issue C/OFalse
Truss ID Signage Installed at Electrical MeterFalse
Range Hood 400+ cfm-Fresh Air REQUIREDFalse
4 inch Building Number Address visible from roadFalse
CO in Bedrooms w/GasFalse
HVAC Vent Terminal 10' from Lot Line & OpeningsFalse
Attic Access GasketedFalse
Jack posts in basement lagged at top and bottomFalse
Flood Plain Certification, if requiredFalse
Guard at deck, porches 36" or moreFalse
6" clearance to sill plateFalse
5/8" Type X with Living Space AboveFalse
Propane Tank: Proper Setback from Prop Line/StructFalse
Bathroom / Kitchen WatertightFalse
Encl. Stairs Sheetrock Underside minimum ½ GypsumFalse
Chimney Height / B Vent / Direct Vent LocationFalse
Deck Ledger-Bolted per CodeFalse
Handrail 4 or more risersFalse
As Built Septic SystemFalse
Attic Access 22 x 30 minimumFalse
Relief Valve ,Heat Trap/Water Temp 110 deg or lessFalse
Plumbing fixturesFalse
Guard at stairwell at 34" or moreFalse
CSST/other piping in conduit if buried,if requiredFalse
Foundation insulation to floorFalse
General CommentsFalse
Duct work sealed properlyFalse
Every level, Every bedroomFalse
OK to Issue Temporary C/OFalse
Guards at stairs,decks,patios 30" + above gradeFalse
Smoke Detectors 3' from Kitchens & Baths R314False
20 Minute Fire Door/Self-Closing HardwareFalse
1/2" Gypsum-Bsmt Ceiling<2x10 Frame/TJI/Fl. TrussFalse
Basement Egress: 5s.f. window w/sill or Bilco doorFalse
Handrail Termination at Newell Post or WallFalse
Fresh air supply 3' from gradeFalse
December 21, 2020Page 2 of 3
INSPECTION WORKSHEET (RESFINAL-004336-2020)
Checklist ItemPassedComments
All Hot Water Systems: 3/4" or larger piping R-3False
Floor truss, draft stop- fin base 1,000 sq. ft.False
4+ Deck Joist Ledger Connections-24" From EndsFalse
Furnace shut-off w/in 30 ft. or w/in line of siteFalse
Roof Complete / Exterior Finish CompleteFalse
Outside Spigots have Air GapFalse
Low water shut-off boilerFalse
HRV or ERV Installed per Bedroom RequirementsFalse
Battery backup: _____False
1/2" Gypsum or House Wall and GableFalse
Crawl Space Access 18 x 24False
Flex Gas Pipe BondingFalse
Interior/Exterior Railings 34 to 38False
December 21, 2020Page 3 of 3