Loading...
2005-802 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUP-A-N- CY Permit Number. P20050802 Date Issued: Friday, June 16, 2006 This is to certify that work requested to be done as shown by Permit Number P20050802 has been completed. Tax Map Number. 523400-227-013-0002-053-000-0000 Location: 58 ROCKHURST Rd Owner. DENNIS & SHARON BUCKLEY Applicant: DENNIS & SHARON BUCKLEY This structure maybe occupied as a: Fireplace By Order of Town Board Residential Alteration TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code E e t Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050802 Application Number: A20050802 Tax Map No: 523400-227-013-0002-053-000-0000 Permission is hereby granted to: DENNIS & SHARON BUCKLEY For property located at: 58 ROCKHURST Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tyne of Construction Value Owner Address: DENNIS & SHARON BUCKLEY 1592 BROOKFIELD Dr Residential Alteration $60,000.00 NEWTOWN, PA 12940-0000 Total Value $60,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2005-802 780 SQ FT RESIDENTIAL ALTERATION $78.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, October 27, 2006 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queenshury before the expiration date.) Dated at t e To of Q e ns day, October 27, 2005 1 • SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement P rmit No. Building &Codes Office-Department of Community Development-Town of Queensb Fee Paid 742 Bay Road, Queensbury, NY 12804 lids ! Ft=�J Recreation Fee Dave Hotin,Director c odesQaueensbury.net Phone: (518) 761-8256 FAX: (518) 745-4437 Principal Structure Building -Permit Application Application & Plans subject to review before issuance of a valid permit for construction. Instructions: A permit must be obtained before beginning construction. No inspections will be made until the applicant has received a valid building permit. All applicants' spaces on this application must be completed and must appear on the application form. Applicant/Builder. --���- ®y l C Owner: - Address: o . /3 „ 3e e Address: Home Phone: Home Phone: Email Address: Email Address: Cell Phone: i2 2 one: a1/.s�- 80/ FAX Phone: _ - _ _ -__w._. ...._....__._.FAX-Phone. 1 Person responsible for supervision of wor respect to building-e�codes compliance: Name: • e4<<r Address: oa W o .ae,s-Phone 4EC-3sYY Location of proposed construction: Lot No. R Legal Address:-Y-e /Aepc Tax Map Number: �'� 7' !3 �'1 _ 3�-3 Subdivision Name: y Estimated Cost of Construction: $ moo. e e o Proposed construction is for: (_Residential,Use _Commercial Use Name of Business: If proposed construction is an addition, what will use of new addition be? �I< <�•ir'.. ..�' New Addition Alteration Proposed Construction 10 Floor 21d floor Other Total Proposed structure (Occupancy Type) Sq. Ft. sq.ft. Sq.Ft. Square feet Height Ft.&In. Single-Family Dwelling spi Two-Famity Dwelling Townhouse Multifamily Dwelling L I Number of Units: Office \\\ J b Mercantile Manufacturing Other: f I .Attached Garage 1, 2, 3 Type of Heating System: Electric, il, Gas, Wood,- arrced Hot Air, Base bo Other: Is a fireplace and/or woodstove being installed, please 4er to a separate application. 7)!- Yes No Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review. The Building and Codes Office will allow commencement of your proposed project only after issuance of your permit. Declaration: Please sign below after you have carefully read the statement: To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new construction, Date: ie1-41-- e Applicant/Builder Signatur The application of dated is hereby approved and permission granted for the construction, reconstruction or alteration of a building/and or accessory structure as set forth above. Date: (Oh- Authorized Signature L:\Sue Hemingway\Building,Permit,FORMS\Principal Structure Permit Application.doc V:12/14/04 Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY (518)761-8205 Application for Fuel Burning Appliances & Chimneys applicable to solid fuel & vented gas appliances g ^` g Date ✓z- , 20 s Pe rmit No. Application is hereby made to the Buildin & Codes Of f ce for the issuance of a Building and Use Permit pursuant to the New York State Fire Pre, Ition and Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information Fuel Burning Appliance Information (circle appropriate words) Stove: wood coal pellet gas Fireplace insert Address: `=' ,� r Fireplace, factory-built: Cawood' gas �� � � {ft �M,,� ,� #.,�� Fireplace, masonry: wood gas Furnace: wood gas oil Phone: '�=• � - ,3,,'Y , r if non-masonary applicance,please provide Owner: .t; s f ;. , Manufacturer Name: Model Number: Address, -- } — Chimney Information Phone: �'! = 2.:?/ - t (circle appropriate words) - Masonry block brick stone Flue the steel )size: _ inches Exact Address: ° "a'i , r s of co •truction or installation Factory-Built Manufacturer name: Model Number: Note: Listed By: Number: Construction IInstallation must conform to NYS Fire Prevention &Building Indicate(circle) chimney material: Code. Consult available Town of Queensbur)r Handouts regarding required inspections. 'Double wall / Triple wall t Insulated / Direct venting _. Chinmey Liner I Ca�aclzier'�r Z2�px�a+�>E'—Tos�.0 oaP$u�e�n,e�bzzxsy, N�e�7['or�ic^- -- i Fire Marshal Code# $Collected $Rcf tnded Received fi-otn (refunded to): N A 173 3389 (190) Public Safety A 233 2655 (230)M" or Sales Lam' r DATE: White(Applicant) / Green(Dire Marshal) / Yellow(Bldg.Dept.) ! Pink&:Goldenrod(Cashier's Dept) Queensbury Building & Code Enforcement Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm De art: %�am/pm Date Ins cfion request received: ®( Inspector's Initials: - i ll L NAME: l t ..f e tC�t PERMIT#: c ' LOCA I DATE: G TYPE OF STRUCTURE: Co men s Yes No N/A BuildingNumber/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porcbes 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backu : Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below Eade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fire roofin /1/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O[Temporary/Permanent L:\Building&Codes Forms\Building&Codes\lnspection Forms\Residential Final Inspection Form revised_100405.doc Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/pm Depart:Z��am/pm Date Inspection request received: Inspector's Initials: NAME: PERMIT#: . _� LOCATION: DATE: TYPE OF STRUCTURE: " Comments Yes No NIA Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks, atios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate zf Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .1-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%:"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enc sure Final Electrical Final Surve Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification Okay to issue C/ C Ter L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc j Framing/ FirestoPPin. Ins ection Report ` Office No. (518) 761-8256 Date Tnspe tao g(lest received: Queensbury Building&Code Enforcement Arrive: (, n/p epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspecto ' itials: NAME: PERMIT#: LOCATION: c�,k4t U 7- to INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. I Notches/Holes/Bearing Walls f Metal Strapping for Notches Top Plate 1 %z w 16 gauge 8) 16D nails each side ^ A �"JLC Draft stopping 1,000 sq. ft. floor trusses ter l chor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing/ FirestoPPm. Inspection Report Office No. (518)761-8256 Date Inspeptio quest received:(, <9 lo�' Queensbury Building&Code Enforcement Arrive: m/e_part: m/pm 742 Bay Road, Queensbury,NY 12804 Inspect s In ials: NAME: PERMIT#: C? LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams i Exterior sheeting nailed properly i 12"O.C. i Headroom 6 ft. 8 in. } Stairwells.36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anch _- '��I� Ice and water shield 24 inches from wall 5 Fire separation 1, 2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Town of:Qp*nsbury Fire Marshal / 742 Bay Road Queensbury,NY 12804 7614W5/761-8206 fax 745407 Factory Built Wood Burning /Stove Inspection Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. J Permit#�(Sd O 'Schedule Inspection te"' Time- l U am pm anytime inspector Ck') Name_ Address ... Rough>a Final Appliance Manufacturer d --- Model# Masonry Chimney Factory Built Chimney VFlue Sixel\ilk Double Wall Triple Wall Insulated Yes Ao N/A Comments Floor Protection Clearances to Combustibles(all sides) Safety Strip Installation(fireplaces only) Firestop(s) Vertical Chase Wall Penetration Chimney Clearances to Combustibles Chimney Termination 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Combustion Air Hearth Extension Mantd(height above f/p opening) Fireplace Doors/Screen(required) White--Baimut DePL Y —C Pink—Fhv Marshal V-- 10 oLr-r-- Rough Plumbing O Insulation Inspection Re oft Office No. (518) 761-8256 Date Inspection request received: A/C)�" Queensbury Building & Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: evw� NAME: PERMIT #: _ LOCATION: INSPECT ON: O TYPE OF STRUCTURE: Y N N/A Rough Plumbing Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction ead 5 P.S.I.jor 10 ft. above highest connection for 15 minutes e Test Water Supply Piping - Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check l5 c:3 Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: N LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005 Town of Queensbury Fire Marshal 742 Bay Road _- Qucensbury,NY 12804 / 761-8205/761-8206 fax 745-4437 Factory Built Wood Burnipg Fireplace/Stove Insaection Resort Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit Q Schedule Inspection- S - ime 21 /5 pm ytime Inspect Name Address -e�- � U` Rough In Final Appliance Manufacturer Model# �i c tS / _ Masonry Chimney Factory Built ChimmeyX Fine Size fY Double Wall Triple Wall_Insulated Yes No NIA Comments Floor Protection Clearances to Combustibles (all sides) Safety Strip Installation (fireplaces only) Firestop(s) Vertical Chase Wag Penetration Chimney Clearances to Combustibles Chimney Termination 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Combustion Air Hearth Extension X Mantel(height above f!p opening) J jrtcl�y�- Fireplace Doors/Screen(required) White-Birilding Dept. Yen- -C —r. Pink-Fire Mashed Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT #: 0, LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents . � 9 } Cast Iron, Copper Drain/Vent/Comm. ' J -PlumbingVent/Vents in Place -�- Rou Plumbing/Nail Plates O _ 1 % inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial 0o er,CPVC,Pex One and Two-Family sulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SucHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Framing / Firestopping Inspection Report �� Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arriv�:r�_am/pm Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspectors Initials: r NAME: J�;I C�i PERMIT#: — C� LOCATION: INSPECT ON: TYPE OF STRUCTURE: ( - r Vi N N/A COMMENTS Framin Attic Access 22'x 30"minimum Jack Studs/Headers i ,i^ f ---�`"�"•' (�,�j c' Bracing/Bridging , 3v m4 I , Joist hangers Jack Posts/Main Beams �", �� `� Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping -- Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart:C - 'am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: w NAME: PERMIT#: � LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N .,. /A COMMENTS aming Attic Access 22"x 30"minimum o Z Jack Studs/Headers j Bracing/Bridging Joist hangers I Jack Posts/Main Beams Exterior sheeting nailed properly V- 12"O.C. Headroom 6 ft. 8 in. t L `�(--tZ-� , j . ✓' Stairwells 36 in. or more Headroom 6 ft. 8 in. -. Notches/Holes/Bearing Walls Metal Strapping for Notches To Plate 1 1/2w 6p ( ) gauge 8 16D nails each side ��� Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft.or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping A \ Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade doe Roul;e: (518)656.3544 Pax(518)636.9901 Box 301,Cleva)Me,NY 12820 t �Q w` W _ J � Z Ji .. W � w O-C N d_ y 1 x� w ' S I 11 N. � = 1 1�1 1 �Inr�S nv- mck IS 2°t ��i Gt1 l� � J I-e,40 M T N(- t''U Re'I4 IZQG F7 �Q C7�A�E ►S' /3' �� Permit Number RECEIVE[ OC i 2 2005 REScheck Compliance Certificate Checked By/Date TOWN OF QUEENSBUM New York State Energy Conservation Construction Code BUILDING AND CODE REScheck Soiiware Version 3.6 Release 2 Data filename: C:\Program Files\REScheck\REScheck\080805 ROULIER-BUCKLEY RESIDENCE-58 ROCKHURST, CLEVERDALE.rck PROJECT TITLE: PLAN NO. 080805 COUNTY: Warren STATE: New York HDD: 7635 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE: Non-Electric WINDOW /WALL RATIO: 0.15 DATE: 10/26/05 DATE OF PLANS: OCTOBER 5, 2005 PROJECT DESCRIPTION: ROULIER-BUCKLEY RESIDENCE 58 ROCKHURST ROAD CLEVERDALE, NEW YORK 12820 DESIGNER/CONTRACTOR: WILLIAMS & WILLIAMS DESIGNERS INC. 509 GLEN STREET GLENS FALLS, NEW YORK 12801 COMPLIANCE: Passes Maximum UA= 172 Your Home UA= 165 4.1%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-ValueR ValueU Factor Ceiling 1: Flat Ceiling or Scissor Truss 389 38.0 0.0 12 Ceiling 2: Cathedral Ceiling(no attic) 550 38.0 0.0 15 Wall 1: Wood Frame, 16" o.c. 1175 21.0 0.0 56 Window 1: Wood Frame:Double Pane with Low-E 136 0.340 46 Door 1: Solid 22 0.130 3 Door 2: Glass 40 0.350 14 Floor 1: All-Wood Joist/Truss:Over Outside Air 778 30.0 10.0 19 Furnace 1: Forced Hot Air, 78 AFUE L COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York tate Pergy Conservation Constriction Code requirements. When a Registered Design Professional has st p and si ed t is e they are attesting that to the best ofhis/her knowledge, belied and pro£ssional judgm t, s h 1 s or cations are in compliance with this Code. esign Date s R +' check Inspection Checklist New York State Energy Conservation Construction Code REScheck Sofware Version 3.6 Release 2 DATE: 10/26/05 PROJECT TITLE: PLAN NO. 080805 Bldg. Dept. Use Ceilings: [ ] ( 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-38.0 cavity insulation Comments: [ ] 2. Ceiling 2: Cathedral Ceiling(no attic), R-38.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Wood Frame:Double Pane with Low-E, U-fctor. 0.340 For windows without labeled U-fictors, describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: Doors: [ ] 1. Door 1: Solid, U-factor. 0.130 Comments: [ ] 2. Door 2: Glass, U-factor. 0.350 Comments: Floors: [ ] 1. Floor 1: All-Wood Joist/Truss:Ovcr Outside Air, R-30.0 cavity+ R-10.0 continuous insulation Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1: Forced Hot Air, 78 AFUE or higher Make and Model Number Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated, or 2)installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. Ifnon-IC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [ ] Required on the wane-in-winter side ofall non vented famed ceilings, walls, and floors. Materials Identification: [ J Materials and equipment must be installed in accordance with the manufacturees installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] ( Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R- [ ] ( Return ducts in unconditioned spaces (except basements)must be insulated to R-2.. Insulation is not required on return duds in basements. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 18113. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point ofthe largest zone. Electric Systems: [ ] Separate electric meters are required fDr each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/ofheatcr switch and require a cover unless over 20% ofthe heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying lluids above 105 T or chilled fruids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature Fl Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickmess in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts 1" and Less 1.25"to 2" .52 "to 4„ Heating Systems Low Pressure(Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only) Joe (518)656-3544 Fax(518)656-9901 / Box 301,Cleverdale,NY 12820 �[�... i— U7ir'JC•�, g isms .. Na�� S.C- .e As or � u 17 G " o y,.