2005-817 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number. P20050817 Date Issued: Friday, October 13, 2006
This is to certify that work requested to be done as shown by Permit Number P20050817
has been completed.
Tax Map Number. 523400-308-005-0001-077-014-0000
Location: 11 LYDIA Ln
Owner. RONALD & JUDITH KEYS
Applicant: RONALD & JUDITH KEYS
This structure may be occupied as a:
Residential Addition By Omer of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
1, j/V e-
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code E orce t
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
(2t 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development-Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20050817 Application Number: A20050817
Tax Map No: 523400-308-005-0001-077-014-0000
Permission is hereby granted to: RnNAT,D & JT JDTTH KFYS
For property located at: 11 LYDIA Ln
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: RONALD & JUDITH KEYS Residential Addition $18,000.00
11 LYDIA Ln Total Value $18,000.00
QUEENSBURY, NY 12804
Contractor or Builder's Name J Address Electrical Inspection Agency
Plans&Specifications
2005-817
360 SQ FT RESIDENTIAL ADDITION (FAMILY ROOM)
$75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday, October 17, 2006
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at t CeTo f Q s ►ry; y, October 17, 2005
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
Job Site Address: LA C: Date:
Owner: R40r9' 4' c,.!U Y K rY�S Application No. File No.
��
Building Permit — Calculation Sheet
Natural-Light, Ventilation & Emergency Egress Requirements
Habitable Area of i % Req.Light Actual Req.Vent Actual <`' Sq.Ft. Remarks
Room Room 8%of Room Light 4%of Room Vent k' Opening for
in Area Square Area Square f Egress
Square , Footage Footage
Feet
Gxrs,7~tNG *� ,t.
//.22 ,
itvrnr , 324E D ,
.64 12,98 22,E
ff
i
� 3wXsSr
} `s ��
,eSi `6tk =y rr
LASueHemingway\BuiIding.PennitTORMS\Nat.Light.Ventil.CalcuIation.Sheet.doc
Job Site Address: / c l c»,� ��, Date: /Y/DZ
Owner: p,y e Ju.or KFYs Application No. File No. CIS--
WINDOW SCHEDULE
Window Window Mfg. Window Unit or Rraglzqugh SrF"I S( ,PT SQ 1~ Clear Clear. Special Hardware or
Number or Name Model Stock E)penxng Olietng' G1assFVzstTz Vent Egss/Clear Opeturtg Q .enng FLegttt Instructions
Letter on Or Type Numberr �ht Ie Open1t}g Width In'`' In Fnckes
Plan Call Size L>glff Inches
.,
A ,gND�RSEN Tway5�88 1/. 2Z &"3a Gs,26 2`7 �$ .30 k4
G-rl-rwOFl C T,1281 1 17 7 l
B ANOG�P 6/1/ �-NZA,441 2-/ng 7 44 /3,4Z. 4,36, 6412 8 29"Is 30 4
�x' d 3 3,.5' 6,q '7.6 r �-
1 ExlsTt;v� "�€S (-® �-� �/•92 33.58 f3 � � xi sr�K
THIS LINE HAS EXAMPLES OF SAMPLE ENTRIES
A' Andersen hlarraliiie 062 2 i/3 6'S l2" 15.30 " &£3G".'. 6 01 2415635 Pempeied
I3oubls. 1116 Glazing
Hun = x
.. ` s
L:\SueHemingway\Building.Pernvt.FORMS\Window Schedule.doc
Fire Marshal's Office Toown of Queensbury,742 Bay Road,Queensbury,NY
'- (518)761-8205
V
Application for Fuel Burning Appliances & Chimneys
applicable to solid fuel & vented gas appliances
Date , 20 QV" Permit No.
Application is hereby made to the Building,& Codes Office for the issuance of a Building and Use
Permit pursuant to the New York State Fire Prevention and Building Code. The applicant or owner
agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of
these requirements and also will allow all inspectors to enter premises to perform required inspections.
NOTE to applicant: Rough-in and Final Inspections are required.
Applicant Information Fuel Burning Appliance Information
(circle appropriate words)
NameLai u � V'' Stove: wood coal pellet V
k
Fireplace insert
Address: i.� t o 1 i Fireplace, factory-built: wood as
,a Fireplace, masonry: wood g s
F Furnace: wood gas oil
Phone:
If non-masonary applicance,please provide
} ,
Owner: � £� €_. Manufacturer Name: �� �( *-��T
Model Number:
Address: 0 V _5 in a,�
Chimney Information
Phone: (circle appropriate words)
Masonry block brick stone
Flue tile —e size. inches
Exact AddressLr ,_ t
of construction or installation Factory-Built
Manufacturer name:
Model Number:
Note: Listed By: _ _Number:
Construction IInstallation must
con Orin to NYS Fire Prevention &Building Indicate(circle) chimney material:
Code. Consult available Town of Queensbury
Handouts regarding required inspections. Double wall / Triple wall / Insulated I Direct venting
Chimney Liner
C'MAeier'Ac 17epax*tm t 4Q:xe493 XbXuy, Wesw Ybm-Ar --
Fire Marshal Code# $Collected S Refunded Received fi-onz (refunded to).
/ ti. address:_ ^` --- --
A 173 3389 (190) Public Safety ~
A 233 2655 (230)Minor Sales
DATE:
White(Applicant) / Green(Fire Marshal) ! Yellow(Bldg. Dept.) / Pink K Goldenrod(Cashier's Dept.)
4
Permit No.
Building 8,Codes Office-Department of Community Development-Town of Queensbury Fee Paid
742 Ba*Road,Queensbury, NY 12804 Recreation Fee
Dave Hatin,Director codes@c{ueensburv.net
Phone: (518) 761-8256 FAX: (518) 745-4437
Principal Structure Building Permit Application
Application & Plans subject to review before issuance of a valid permit for construction
Instructions: A permit must be obtained before beginning construction. No inspections will be made until the
applicant has received a valid building permit. All applicants' spaces on this application must be completed and
must appear on the�pli atign form.
Applicant/Builder 7? z Ida Owner: RoAl ;may
Address: r Wk Address: i1 ��`al: �Lv
AJ to 33 1QFbf/
wR
Home Phone: - Io Home Phone: ss/�) -2qa 3i5
Email Address: Email Address:
Cell Phone: Cell Phone:
FAX Phone: FAX Phone:
Person responsible for supervision of work with respect to building and codes compliance:
Name: / a-r r _
Address: o?b Phone 6
Location of proposed construction: Lot No. Legal Address:
Tax Map Number: V-5 1- / (• Subdivision Name:
Estimated Cost of Construction: $ ier�QO_='� dt
Proposed construction is for: Residential Use _Commercial Use p, -
Name of Business:
If proposed construction is an addition, what will use of new addition be? q : A 2
New dditfon Alteration Proposed Construction 1,t Floor 2nd floor Other Total Proposed
structure (Occupancy Type) Sq. Ft. sq.ft. Sq,Ft. Square feet Height
Ft.&in.
Single-Family Dwelling
Two-Family Dwelling
Townhouse
MuNifamity Dwelling
Number of Units:
Office
Mercantile
Manufacturing
Other:
Attached Garage 1, 2, 3
Type of Heating System: Electric, Oil, Gas, Wood, Forced Hot Air Baseboard, Other:
Is a fireplace and/or woodstove being installed, please refer to a separate application. Yes No
Applications are subject to Zoning Administrator, Code Compliance, and Structural Plan review.
The Building and Codes Office will allow commencement of your proposed project only after
issuance of your permit.
Declaration: Please sign below after you have carefully read the statement:
To the best of my knowledge, the statements contained in the application, together with the plans and
specifications submitted, are a true and complete statement of all proposed work to be done on the described
premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the
proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner.
Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance
being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a
licensed surveyor, drawn to scale, showing actual location of all new construction.
r,
Date:6 l sue- Applicant/Builder Signature:
The application of dated is hereby approved and
permission granted for the construction, reconstruction or 7ration of a building/and or accessory structure as set
forth above.
Date: d Authorized Signature:
L:\Sue Hemingway\Building.Permit.FORMS\Principal Structure Permit Application.doc V:12/14/04
ueensbu Building & Code Enforcement - Residential Final I�ection U�
Q rY � P
Office No.(518)761-8256 Arrivf: am/ Ke a mDate Inspection request received: Inspector s Ini I
NAME: �. eAE!:
T
LOCATION:
TYPE OF STRUCTURE: B EA t non
m cents
Yes No N/A P��_ F\
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks, atios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate _
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s . ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below ade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater o eratin
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Tern 110
Enclosed Stairs Sheetrock Underside minimum%z"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fire roofin /%hour fire door/door closer
Duct work Sealed pro efl
Gas Low in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required____
Flood Plain Certification,if required
Okay to issue C/C or C/O [Temporary(Permanent
L:\Building&Codes Forms\Building&Codes\lnspection Forms\Residential Final Inspection Form—revised—I 00405.doc
Queensbury Building & Code Enforcement - Residential F' 1 Inspection - l
Office No. (518)761-8256 / Arrive: A D art: A,�E�
Date Inspection request received: 5 � �w` Inspector's Initia : /
NAME: ' P T#: t1
LOCATION: (��g �ir�� D T �
TYPE OF STRUCTURE:
Comments
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location _ L���
Fresh Air Intake ` O
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Com lete
Platform at all exterior doors G- \
Guards at stairs,decks, atios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft,150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/Y4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O [Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 176 Doe Run Road-Manheim,PA 17545
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
Permit No...................... ................Clert.N2 93153 Cut-in Card No..............................
Owner........................ e.. .......
/. ��/..-5...................................................................................................
Location...................U..........�;l/ l..A.....L?./ ........................... .i.t.. 4.t .,9.. .0 .................
Inst//allation Consisting of..... s.......L'A. l..�.Q 2.�=......../..�?.../�� .4-}......................
4.....S..kc�l...:..... ...... ..l.. ....................................................................................................................
....................................................................................................................................................................................
InstalledBy.............s..h?. .......................................................Lic.No...................................................
The conditions following governed the issuance of this certificate,and any certificate previously issued is
cancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations,application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of making inspections at any time, and if its
rules are violated,the Company shall have the right to revoke this certificate. J J
Date....... . .I O.' .�4................ INSPECTOR rca� . /r�^- ..................................
Member N.RP.A.,I.A.E.I.
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspe on recut received:
Queensbury Building&Code Enforcement Arrive:' am/ m Depart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initialsl�Ci�
NAME:_ PERMIT #: C 7
LOCATION- INSPECT ON: �- o
TYPE OF STRUCTURE: J j ,
Y N N/A
PVC: R-1,R-2,R-3,R-4 Drain/Vents
Cast Iron,Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 % inch min.Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout eve 100 feet/chi a of direction �(�S Z
Water Supply Piping t C
Cooper Commercial Zj
Coo , PVC,Pei One and Two-Family
Ado /Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace A
Duct work sealed properly./No duct tape
COMMENTS:
LASueHemingway\8uilding.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003
Framing / Firestoppmg Inspection Report X0
Office No. (518)761-8256 Date Ins ectti n r }uest received: 1-6 -
Queensbury Building&Code Enforcement Arrive: a Depart: am/pm
742 Bay Road,Queensbury,NY 12804 Inspecto itial3
NAME: wti, �r.� PERMIT#: &SJ 41 7
LOCATION: INSPECT ON: 1Ljv��-f w, a3
TYPE OF STRUCTURE: - �
Y NIA COMMENTS
F>'
Attic Access 22"x 30"minimum 1 g
Jack Studs/Headers
wBracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %z w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq.ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fir eparation 1, 2, 3 hour
ire wall 2, 3,4 hour
treso)Ving
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side ''/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in.(W)
5.7 sf above/below grade
5.0 sf gade
Framing / Firestopping Inspection Report
Office No.(518) 761-8256 Date Leis cponXc4jmst received:
Queensbury Building&Code Enforcement Arrive: m/pm D�ePart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector s Initials: A J19
NAME: C PERMIT#:
LOCATION: {,�} r� INSPECT ON: l Cf
TYPE OF STRUCTURE:
Y N /A raming COMMENTS
Attic Access 22"x 30"minimum
Jack Studs/Headers ` l•
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
I
Stairwells 36 in. or more
a
Headroom 6 ft. 8 in. 1
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/s(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side '/z inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms j
24 in. (H)
20 in. (W)
a
5.7 sf above/below grade
5.0 sf grade
Framing /Firestoppin ; Inspection Report - - I
Office No. (518) 761-8256 Date Lzsp�rqtipn re received:
Queensbury Building&Code Enforcement Arrive: epart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT#: 7
LOCATION: INSPECT ON: Z
TYPE OF STRUCTURE: '
/ V ATY)
Y N N/A-Fril ming COMMENTS
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in.or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
I '/z w 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft.or less on center
I nd water shield 24 inches from wall
App
Fire separation 1,2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side '/z inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Foundation Inspection Report
Office No. (51 8) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p Depart: in
742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: �,�t.G
NAME: - PERMIT#:
LOCATION: _ ° 1 ;�� INSPECT ON: _�
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings Ty
Piers
Monolithic Slab _
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site. -`
Foundation/WallpourAl-
f'
Reinforcement in Place T
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R- _
Rough Grade 6 inch drop within 10 ft.
L:\SueHemingway\Building.Codes.Inspection.FURMSToundation Inspection Report.doc January 28,2003
9Wk
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: _
Queensbury Building&Code Enforcement Arrive:G� am/pm�-'_-Depart: am/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Ifiit als.Y - �_,
_
NAME: PERMIT#: 7
LOCA:ION: _ \ INSPECT ON:
TYPE OF STRUCTU �,�c-.
Comments
Y N N/Aotings
' f
V L'
Piers ^�
Monolithic Slab
Reinforcement in Place ?� I
The contractor is responsibler
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site. `
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval Plumbing Under Under Slab _
PVC/Cast/Copper
Foundation Insulation^Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
LASucHemingway'Building.Codes.Inspection.FORM SToundation Inspection Report.doc January 28.2003
G. Peter Jensen
17 West Road
South Glens Falls
New York 12803
(518) 798—3859
January 12, 2006
Re: Ron& Judy Keys Addition
To Whom It May Concern:
The rigid insulation may be eliminated from the sidewalls of the Ron& Judy
Keys addition, plan#05-0802, provided '/z" rigid insulation(R-4) is added to the ceiling.
This would provide a total ceiling insulation value of R-42. The attached Res Check
indicates that the change would meet the requirements of the Energy Conservation
Construction Code of the State of New York.
Sincerely,
�tR�° Arc RECEIVED
�yl a C•
G. Petef Jensen
' IAN 2 4 2006
' i N UI TOVV
t 4 r
0i'bp24
,9rF OF NeM j�
Permit Number
REScheck Compliance Certificate Checked By/Date
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release le
Data filename:Untitled.rck
PROJECT TITLE:Ron&Judy Keys
COUNTY:Warren
STATE:New York
HDD: 7635
CONSTRUCTION TYPE:Detached 1 or 2 Family
HEATING TYPE:Non-Electric
DATE: 01/12/06
DATE OF PLANS:Oct 05
PROJECT DESCRIPTION:
Residential Addition
COMPLIANCE:Passes
Maximum UA=77
Your Home UA=77
0.0%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U Factor UA
Ceiling 1:Flat Ceiling or Scissor Truss 360 42.0 0.0 10
Wall 1: Wood Frame, 16"o.c. 464 21.0 0.0 21
Window 1: Wood Frame:Double Pane with Low-E 58 0.340 20
Door 1: Glass 40 0.340 14
Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 360 30.0 0.0 12
Furnace 1:Forced Hot Air,78 AFUE
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,
specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the
New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and
signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment, such plans or
specifications are in compliance with this Code.
Builder/Designer Date
.a
ti
02ep20 P�
TF 09 NEW yp
REScheck Inspection Checklist
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release le
DATE: 01/12/06
PROJECT TITLE:Ron&Judy Keys
Bldg. I
Dept. I
Use I
I
Ceilings:
[ ] I 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-42.0 cavity insulation
Comments:
I
Above-Grade Walls:
[ ] I 1. Wall 1:Wood Frame, 16"o.c.,R-21.0 cavity insulation
Comments:
I
Windows:
[ ] I 1. Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
I #Panes Frame Type Thermal Break?( ]Yes[ ]No
Comments:
I
Doors:
[ ] I 1. Door 1: Glass,U-factor:0.340
Comments:
i
Floors:
[ ] I 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation
Comments:
I
Heating and Cooling Equipment:
[ ] I 1. Furnace 1:Forced Hot Air,78 AFUE or higher
Make and Model Number
I
Air Leakage:
[ ] I Joints,penetrations,and all other such openings in the building envelope that are sources of air
I leakage must be sealed.
[ ] I Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly
I with a 0.5"clearance from combustible materials. If non-IC rated,the fixture must be installed with a
3"clearance from insulation.
I
Vapor Retarder:
[ ] I Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
I
Materials Identification:
[ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] I Materials and equipment must be identified so that compliance can be determined.
[ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating
I equipment must be provided.
[ ] I Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications.
I
Duct Insulation:
[ ] I Supply ducts in unconditioned attics or outside the building must be insulated to R-11.
[ ] I Return ducts in unconditioned attics or outside the building must be insulated to R-6.
[ ] I Supply ducts in unconditioned spaces must be insulated to R-11.
[ ] I Return ducts in unconditioned.spaces(except basements)must be insulated to R-2.
Insulation is not required on return ducts in basements.
I
Duct Construction:
[ ) I All joints, seams,and connections must be securely fastened with welds,gaskets,mastics
I (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in.w.g. (500 Pa).
( ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] I Air filters are required in the return air system.
[ ] I The HVAC system must provide a means for balancing air and water systems.
I
Temperature Controls:
[ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
I
Electric Systems:
[ ] I Separate electric meters are required for each dwelling unit.
I
I Fireplaces:
L ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ) I Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
I provisions of the Building Code of New York State,the Residential Code of New York State or
the New York City Building Code,as applicable.
Service Water Heating:
[ ] ( Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
I water heater has an integral heat trap or is part of a circulating system.
[ ] ( Insulate circulating hot water pipes to the levels in Table 1.
I
Circulating Hot Water Systems:
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Swimming Pools:
[ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
I of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I
Heating and Cooling Piping Insulation:
[ ) I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 T must be insulated to the
I levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Up to 111 Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HvAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD (Building Department Use Only)
r- 7-
i mber
REScheck Compliance Certificate Checked B to
2000 IECC
REScheckSoftware Version 3.6 Release 1
Data filename: Untitled.rck
PROJECT TITLE: RON&JUDY KEYS
CITY: Glens Falls
STATE:New York
7635
CONSTRUCTION TYPE: Single Family
WINDOW/WALL RATIO: 0.21
DATE: 01/09/06
DATE OF PLANS: 10/11/05
PROJECT DESCRIPTION:
RESIDENTIAL ADDITION
11 LIDIA LANE
QUEENSBURY,NY 12804
DESIGNEWCONTRACTOR:
G.PETER JENSEN
COMPLIANCE:Passes
Maximum UA=77
Your Home UA=77
0.0%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1:Flat Ceiling or Scissor Truss 360 38.0 4.0 10
Wall 1:Wood Frame, 16"o.c. 464 21.0 0.0 21
Window 1:Wood Frame:Double Pane with Low-E 58 0.340 20
Door 1: Glass 40 0.340 14
Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 360 30.0 0.0 12
Furnace 1:Forced Hot Air,78 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications,and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2000 IECC requirements in RES checkVersion 3.6 Release 1 (formerly MECchecl and to comply with the
mandatory requirements listed in the RES checkInspection Checklist.
Builder/Designer Date
REScheck Inspection Checklist
2000 IECC
REScheckSoftware Version 3.6 Release 1
DATE: 01/09/06
PROJECT TITLE:RON&JUDY KEYS
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss,
R-38.0 cavity+R-4.0 continuous insulation
Comments:
Above-Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16"o.c.,R-21.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1:Wood Frame:Double Pane with Low-E,U-factor: 0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
Doors:
[ ] 1. Door 1: Glass,U-factor: 0.340
Comments:
Floors:
[ ] 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation
Comments:
Heating and Cooling Equipment:
[ ] 1. Furnace 1: Forced Hot Air,78 AFUE or higher
Make and Model Number
Air Leakage:
[ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly
with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a
3"clearance from insulation.
Vapor Retarder:
[ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications.
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives),
mastic-plus-embedded-fabric,or tapes. Tapes and mastics must be rated UL 181A or UL 181B.
Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 IF or chilled fluids below 55 T must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pine Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Un to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVACPipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping ystem Types Ran e F 2"Runouts V and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD (Building Department Use Only)