Loading...
2004-140 � ` TOWN OF QUEENSBURY IF 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20040140 Date Issued: Monday, June 21, 2004 This is to certify that work requested to be done as shown by Permit Number P20040140 has been completed. Tax Map Number: 523400-239-015-0001-010-000-0000 Location: 14 CROOKED TREE Dr Owner: KATHARINE SEELYE Applicant: KATHARINE SEELYE This structure may be occupied as a: By Order of Town Board Residential Addition ,w OWN OF •UEENSBURY 1 Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040140 Application Number: A20040140 Tax Map No: 523400-239-015-0001-010-000-0000 Permission is hereby granted to: KATHARTNF. SEM,YF, For property located at: 14 CROOKED TREE Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: KATHARINE SEELYE 2122 CALIFORNIA ST. NW ResidentialAddition Total Value WASHINGTON, DC 20008-1335 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2004-140 RESIDENTIAL ADDITION $75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,April 08, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tow of Qu nsbu T �s!.f v.s ri108, 2004 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement • Building Permit Application Town of Queensbury-Dept of Community Development,742 Bay Road,Queensbury,NY (518)761-8256 • A permit must be obtained before beginning construction. Permit File No. ® -/c/o No inspection will be made until applicant has received a Fee Paid $,/.3 valid building permit. All applicants' spaces on this Rec.Fee Paid $ application must be completed and must appear on the Reviewed B : application form. `` c y' Applicant: i d ee ( i Owner: . kv'� i -e_ Address: y ( cor 4-re e I&A& Address: /y 'rool i ree /4h e_ £4,�e CGcci.e ill Y• 2-9q Lu, Goo .e AY. 12 7? Phone#(fik) G(J - e-2-78 Phone#( / ) C4:£) - 6-5-7£1 • Property Location: Lot Number: / House Number /Y Subdivision Name: Tax Map Number: - 12_ I 2. 9- i5 - 1 -10 a New Building: residence /commercial 'Estimated Market Value of Construction: $ — - - rb�Addition: residence/ commercial a Alteration: residence/ commercial If an Additiqn,what will use of new addition be? 0 No change to exterior size: residence/com'l �"`.1 nc!r/ IV 0 Other work(describe ) Check OccupancyInformation 1"Floor 2 Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet a Single family dwelling a Two family dwelling a Townhouse o Multifamily dwelling ® � #of units _ �4 a Office a Mercantile OR 0 1 .2�704 a Manufacturing a 1 oar detached garage TOWN CF SJEENSEURY a 2 car detached B���� nuspi mon cOnF garage a 3 car detached garage 0 1 oar attached garage a 2 oar attached garage a 3 car attached garage 0 Storage building- commercial a Storage building- residential 3 Nx U 9 • a Other /'cat► •,-yO P 2-lc /C) / What is the proposed height of the structure feet /3 2 inches Will any second-hand or ungraded lumber be used? If so,for what? Iv 0 Type of Heating System: electric/ oil / a wood /forced hot air/ baseboard/other: Number of Fireplaces to be installed ` Number of Woodseoves to be installed /Voll-e- List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder Lam. . a . 'lij�l,; U Plumber Mason i • 1 lwt r<... _ . �i_. . eri d ka llY a2 c; Electrician �Ju 'te 7 IF La Ai'''. ' y1 y-sl73Q Declaration: please sign below after you have carefully read the statement To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Uwe shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an els Built Survey by a licensed surveyor;drawn to scale,showing actual location of all nstru 'o Signature: owner,owner's agent,architect,contractor • �Q Lie" Residential Final Inspection . Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: ,t/20 am/ Depart: am/pm C`sc-cf)3u 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: ' �— 7(06k, cti7� NAME: PERMIT#: LOCATION: DATE: � riret TYPE OF STRUCTURE: • Comments • Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 in.or more @ stairs, decks,patios ✓S Guard at stairwell at 34 in.or more 1� Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in. to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate • Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler • Relief Valve(s)installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches _ 3/4 hour fire door/door closer Garage fireproofing Duct work Sealed properly Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq. ft.-150 sq. ft.vents Building No./Address visible from road Final Electrical i� • Site Plan /Variance required �,,,/lG'/I CO Final Survey Plot Plan i�// As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C(Cert. Of Compliance) jj1Jn 2r Okay to issue Temporary C I 0(Cert. Of Occupancy) V Okay to issue Permanent C/0(Cert. Of Occupancy) L:1SueHemingway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003 Residential Final Inspection Office No. (518) 761-8256 Date Inspection request received: . Queensbury Building&Code Enforcement Arrive: /O'er am/pm Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: p . NAME: c( c ()( PERMIT#: (J — t) LOCATION: l y , v /rtc- (i:.,' DATE: TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 in. or more @ stairs,decks,patios 7 r� Guard at stairwell at 34 in. or more ,,,4 /s rcZ v/ ,J e•y Guard at deck,porches 36 in. or more Exterior Finish Complete • Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site • Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed • Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches 3/4 hour fire door/door closer Garage fireproofing Duct work Sealed properly Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq. ft.-150 sq. ft.vents Building No./Address visible from road , /r n / 1/ / �"/�s/ Final Electrical . �� ,4 x/ /nc/ o e a Site Plan /Variance required p Final Survey Plot Plan f� �ry0. �21f 7 c eX Ih f,'1�, As Built Septic System/Sewer Dept. Inspection Sticker g h'0"Z"re ertification, if required •C/C(Cert. Of Compliance) Temporary C/0 (Cert. Of Occupancy) 'Permanent C/0 (Cert. Of Occupancy) ty\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003 Residential Final Inspection . Office No. (518)761-8256 Date Inspection request received: . Queensbury Building&Code Enforcement Arrive: ,2r 3-, am/pm Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: '-ipk" . '' NAME: islet?e. r PERMIT#: 0`�-we, LOCATION: �� � i�C� \ i ez <<-'c DATE: S7/10 TYPE OF STRUCTURE: Comments Y lei N/A. Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof IJ i Roof Complete . Guard 30 in. or more @ stairs,decks,patios t✓ Guard at stairwell at 34 in. or more tiid �Q�( L, ei Srz r/ r ir ive(j// Guard at deck,porches 36 in. or more ✓ Exterior Finish Complete ✓ Interior/Exterior Railings 34 in.to 38 in. ✓ . Platform at all exterior doors V Interior Handrails stairs 2 or more risers . Grade away from foundation 6 in. with 10 ft. ✓ Handrail Termination at Newell Post or Wall ✓ 8 inch clearance to sill plate ✓ __ Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30.ft. or within line of site ✓Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shutoff boiler . Relief Valve(s)installed 1✓- Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight 1/- Safety glazing ✓ Window in stairwells safety glazing . Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: / Inter Connected: / Battery backup: • . Bathroom Fans, if no window / Carbon Monoxide detector V Plumbing fixtures Foundation insulation ' ✓ /,�� ; ;J4Gt•` 4- ^�'`� °� Floor truss,draft stopping finished basement 1,000 sf Vj Emergency egress below grade ✓ /� Basement stairs closed rise>4 inches V C lao— 6s`eU 3/4 hour fire door/door closer Zr Garage fireproofing 1 / Duct work Sealed properly ✓� Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq.ft.-150 sq. ft.vents Building No./Address visible from road ✓ �' / � Final Electrical ✓ , ,l/ rie d,"r -�/:y Site Plan /Variance required Final Survey Plot Plan . Vz As Built Septic System/Sewer Dept. Inspection Sticker - Flood Plain Certification, if required ✓ Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C/0(Cert. Of Occupancy) Okay to issue Permanent C/0(Cert. Of Occupancy) L:\SueHemingway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: Cj J/Vf am/pm Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: (/-- NAME: — crPe e PERMIT#: LOCATION: INSPECT ON: c- d TYPE OF STRUCTURE: Comments Y N N/A Footings �f Piers • Monolithic Slab Reinforcement in Place The contractor is responsible for • providing protection from freezing • for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place f $ Foundation Dampproofing y/ Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width • 6 inches above footing 6 mil poly for'wet areas under slab Backfill Approval 6 Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:1SueHemingway\Building.Codes,Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Framing /Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: /► 3v am/pm Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: C /F • NAME: �AQ� i r. `� 4— /. PERMIT#: `7— LOCATION: � c�r� ,o j r(�'.-2 �Y INSPECT ON: -O LI TYPE OF STRUCTURE: cc�? y N N/A COMMENTS airing Jack Studs I.Headers Bracing/Bridging s / Joist hangers Vic,, j( �G etc Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center • Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed • 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade • L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report j /ii � ViN6 ti Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: „PIA,' am/pm . Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials:4 c NAME: 5-e_c).e-y PERMIT#: �--� ,I LL LOCATION: i L( C(rc>v\/,-Pm-fv-e- 1 "-- INSPECT ON: F/ TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates / Head or Air Supply Test / 1?.(1 Drain and Vents j`r. riu,.. 4'� 5 PSI or 10 ft. above highest ri/a . Connection for 15 minutes e��,� C ( s I Water Supply Piping / X Copper Commercial t/ Copper, CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces _ Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: • L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Framing /Firestopping Inspection Report C._D Office No. (518) 761-8256 Date Inspp,ection request received: 1 iJ A ' 'A/ Queensbury Building&Code Enforcement Arrive:a&i am/ i Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: . • NAME: SQei(- PERMIT#: a()/L(/1��0 LOCATION: l C rho -�, .ems z_5c — INSPECT ON: TYPE OF STRUCTURE: Y i i N/A COMMENTS .„)eraming Jack Studs/Headers Bracing/Bridging 1 Joist hangers / Jack Posts/Main Beams 1/ Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center • Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour n Firestopping /C Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side ''/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade • L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Queensbury Building & Code Enforcement - Residential Final Inspection -k• O.fice 1No.(518)761-8256 Arrive: /i am/pm Depart: am/pm 1 Date Inspection request received: Inspector's Initials: `�' NAME: I \G� �.,��, n e G ? v.9 ` PERMIT#: O Z—( ( 1-( 0 LOCATION: 1 L\ ('\roc) DATE: TYPE OF STRUCTURE: C—=- Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs, decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in. to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum ''A" Gypsum Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating ■■■ Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safet tlazin_ Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector _ Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss, draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing I%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24" access, 1 sq. ft.-150 sq. ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/0 [Temporary/Permanent] L:\PamW\Building&Codes\Inspection Forms\Res.Final Insp. form 2.docLast printed 2/12/04 Framing /Firestopping Inspection Report Office No. (518) 761-8256 Date Inspe tion request received: Queensbury Building&Code Enforcement Arrive: JJ'C- am/pm .Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: Df NAME: Yee-filg, PERMIT#: 7 V6I LOCATION: PO cid/ INSPECT ON: l ' TYPE OF STRUCTURE: Y N ,N/A COMMENTS Framing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. , e l,••� L I T" Headroom 6 ft. 8 in. Stairwells 36 in. or more 4. ok•k, Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center • Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in,cavity min. Garage Fire Separation House side 1Y2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade • • L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 • Rough Plumbing / Insulation Inspection Report • Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: AV'(Nam/pm Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: '2/1— NAME: I,y t _ PERMIT#: G y 6 LOCATION: /`f JJJJ ciZ74/ t (. INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place _ y� Rough Plumbing/Nail Plates A s;v. Head or Air Supply Test Drain and Vents • ��c,/ Gir �� 5 PSI or 10 ft. above highest • Connection for 15 minutes Water Supply Piping • Copper Commercial Copper,CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check Proper Vent, Attic Vent et„/ ¢r�� Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace I / LA-4z Duct Work Sealed Properly (� J� L ter- ea, -2e— COMMENTS: • • •L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: /t&r am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: (7)0- NAME: PERMIT#: G V- LOCATION: r Y. ����� « (4„� INSPECT ON: 3 u U TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Jack Studs/Headers Bracing/Bridging Joist hangers ✓ _ 1 �� '�' r/ Jack Posts/Main Beams _ 444( „�� `J.*ram C,� jGAf13. Exterior sheeting nailed properly , / 12"O.C. �; {�e Ci,n) Headroom 6 ft. 8 in. � S d� ` fop �crr2c. Stairwells 36 in. or more t� Headroom 6 ft. 8 in. e /ev,,., Notches/Holes/Bearing Walls // ._. C(vi � riJ2r.5 Metal Strapping for Notches Top Plate S F ��i? �z�c�t"— 1 'A (w) 16 gauge (8) 16D nails each side ✓ ee.- J v �~ Draft stopping 1,000 sq. ft. floor trusses 145 k— rail- 411 Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall ' / ��,,frel / I�' / Fire separation 1, 2, 3 hour ,/ Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueFlemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: /j f am/pm Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: V NAME: �i 17 z- - PERMIT#: (�' �'1` 'C) LOCATION: J`-( 1? L INSPECT ON: 3 TYPE OF STRUCTURE: Comments N N/A Footings ��'' / /V z,,, ' J 2rerJ� a g 4/Za% Piers J • Monolithic Slab �,,A6.4 4`' ��// ven Reinforcement in Place fog �S pep�'h j s,z / C The contractor is responsible for ,�s providing protection from freezing 04� 1 J • for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofmg/Waterproofing Footing Drain Daylight or Sump • Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. • L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 • Permit umber MECcheck Compliance Report Checked By/Date 2000 IECC MECcheck Software Version 3.3 Release lb Data filename:C:\Program Files\Check\MECcheck\Addition to Seelye Residencel.cck TITLE:Addition to Seelye Residence CITY:Glens Falls STATE:New York HDD:7635 CONSTRUCTION TYPE: Single Family DATE:03/30/04 DATE OF PLANS:March 17,2004 PROJECT INFORMATION: Kit Seelye Residence 14 Crooked Tree Drive RECEIVED Town of Queensbury COMPLIANCE:Passes A PR 0 i 2004 TOWN OF QUEENSBURY Maximum UA=83 BUILDING N CO® Your Home=80 3.6%Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Cathedral Ceiling(no attic) 158 57.6 0.0 3 Skylight 1:Wood Frame,Double Pane 13 0.840 11 Wall 1:Wood Frame, 16"o.c. 93 19.0 0.0 6 Wall 2:Wood Frame, 16"o.c. 106 19.0 0.0 6 Window 1:Wood Frame,Double Pane 3 0.560 2 Wall 3:Wood Frame, 16"o.c. 106 19.0 0.0 6 Window 2:Metal Frame,Double Pane 9 0.570 5 Wall 4: Wood Frame, 16"o.c. 150 19.0 0.0 9 Basement Wall 1:Masonry Block with Empty Cells,8.0'ht/6.0'bg/7.0'insul 80 0.0 10.0 6 Basement Wall 2:Masonry Block with Empty Cells,8.0'ht/6.0'bg/6.0'insul 126 0.0 10.0 9 Basement Wall 3:Masonry Block with Empty Cells, 8.0'ht/7.5'bg/7.5'insul 80 0.0 10.0 5 Basement Wall 4:Masonry Block with Empty Cells,8.0'ht/6.0'bg/4.0'insul 126 0.0 10.0 12 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in MECcheck Version 3.3 Release lb and to comply with the mandatory requir ' ted in the ME.check Inspection Checklist. Builders Date MECcheck Inspection Checklist 2000 IECC MECcheck Software Version 3.3 Release lb DATE:03/30/04 TITLE:Addition to Seelye Residence Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Cathedral Ceiling(no attic),R-57.6 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 2. Wall 2:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 3. Wall 3:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 4. Wall 4:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 1:Masonry Block with Empty Cells,8.0'ht/6.0'bg/7.0'insul, R-10.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. [ ] 2. Basement Wall 2:Masonry Block with Empty Cells, 8.0'ht/6.0'bg/6.0'insul, R-10.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. [ ] 3. Basement Wall 3:Masonry Block with Empty Cells,8.0'ht/7.5'bg/7.5'instil, R-10.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. [ ] 4. Basement Wall 4:Masonry Block with Empty Cells,8.0'ht/6.0'bg/4.0'insul, R-10.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. Windows: [ ] 1. Window 1:Wood Frame,Double Pane,U-factor:0.560 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ J 2. Window 2:Metal Frame,Double Pane,U-factor. 0.570 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No • Comments: Skylights: [ ] 1. Skylight 1:Wood Frame,Double Pane,U-factor.0.840 For skylights without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be Type IC rated and installed with no penetrations,or Type IC or non-IC rated installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials and 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0, Duct Construction: [ ] All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ]. All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 105°F or chilled fluids below 55°F must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only) 1