Loading...
blower door resultsTesting Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:12 Chestnut Address:12 Chestnut Ln Lake George, NY 12845 Geo-Tag Data:Latitude: 43.464811 Longitude: -73.654852 Timestamp: 2020-12-29 07:59:53 Customer Information: Name:Trevor McNeice Address: Measured Leakage:841.8 CFM50 Test ID:12 Chestnut 2 Purpose of Test:50 Pa Env. Leakage Measured ACH50:2.59 Effective Leakage Area: 46.3 in² Building Volume:19,488.0 ft³Enclosure Surface Area: 2,640.0 ft² Coefficient (C):66.2 Exponent (n): 0.650 (assumed) Test Standard:RESNET 380 One-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 52 °F Altitude: 344.0 ft Outdoor Temp: 30 °F Time Average Period: 10 seconds Test Date and Time:2020-12-30 15:33:06 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -0.9 -50.0 -49.8 -48.9 -216.7 871.6 Ring B Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3173 Custom Calibration Date: 2020-02-10 Pressure Gauge:DG1000 Serial #: 5193 Calibration Date: 2020-01-16 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.7.3 (91), © 2020 The Energy Conservatory, Inc.