2005-934 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OFOCCUPANCY
Permit Number. P20050934 Date Issued: Monday, January 22, 2007
This is to certify that work requested.to be done as shown by Permit Number P20050934
has been completed.
Tax Map Number. 523400-308-016-0001-045-000-0000
Location: 36 PINEWOOD Rd
Owner. WILLIAM BROWN
Applicant: WILLIAM BROWN
This structure maybe occupied as a:
Garage - 1 Car Attached By Order of Town Board
Residential Addition TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20050934 Application Number: A20050934
Tax Map No: 523400-308-016-0001-045-000-0000
Permission is hereby granted to: WILLIAM BROWN
For property located at: 36 PINEWOOD Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: WILLIAM BROWN
PAMELA HIGGINS Garage Attached
36 PINEWOOD Rd Residential Addition $19,000.00
QUEENSBURY, NY 12804 Total Value $19,000.00
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2005-934
704 sq ft I-CAR ATTACHED GARAGE WITH 704 SQ FT LIVING SPACE ABOVE
$140.80 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday, March 02, 2007
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To o ueensb T rsday, March 02, 2006
SIGNED BY for the Town of Queensbury.
Director of Building c�.Code forcement
OFFICE USE ONLY ; �, rc� ,
3
PERMIT NO.
TAX MAP NO-30
; , ;
DEC
i FEES: PERMIT �� � RECREATION ENGINEERING i ; 2005 i
(If applicable) f O�VIN o ',
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. i
APPLICANT/BUILDER: )Oyu, -S&nW24 OWNER: Qh'1 GC�/1
ADDRESS: lD`[ V` 4ya)n Late. N ADDRESS: L`f l?9eur?Dc4 ecl
PHONE NOS. S�2- 1`� Z C�� 7 Ic970 PHONE NOS.
CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: ONE" 7-
d `Rt:C
LOCATION OF PROPERTY: ii- - ,.&
DEC 0 7 2005
SUBDIVISION NAME.-
EIVSRr f�,�,
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT p ❑ i-
APPLY TO YOUR z F- ❑ O Q "'
PROJECT CO W
F- O O ~ =
❑ W 0U_, � � _ O = U
W ❑ J a z O �
Z Q Q r (n N Cn O u_ [ 2 06
SINGLE FAMILY
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS )
:s
TOWNHOUSE
BUSINESS OFFICE
RETAIL- j
MERCANTILE
FACTORY OR
INDUSTRIAL
4TACH�EDD
GARAGE02'3) 76 ey-�gr�fA�lit�
OTHER
IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST:" 4me-° Please complete a separate Application
for"Fuel Burning Appliances&Chimneys"
available in our office
HOW MANY FIREPLACE(S): AND/OR W.00DSTOVES(S):
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?
IS THIS A HISTORIC SITE?
PROPOSED USE OF BUILDING 0 ADDITION` IQ
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN?
Town of Queensbury • Community Development Office - 742 Bay Road, Queensbury,NY 12804
ARE THERE EASEMENTS ON PROPERTY?
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.. .
Signed6�aw"� U6 2'k
Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
, / '
Permission is hereby granted to the above This application / proposed action described
Applicant to erect or alter the building herein is found to be in accordance with the
described herein in accordance with said % zoning Laws of the Town of Queensbury. 01
,
Application: ' '
.. - , , ,
I , / ,
I ` 1 0 1
l JJ////jjjj`�(\l� 0
BU IN & CODES AP OVAL oo ZONI PPROVAL ;
,
1 , 0 7 '
DA E DATE 0
'
0 r '
0
0-------------------------------------------- �___________________________________________:
QUESTIONS? CALL 761-8256 OR EMAIL
codes@queensbury.net
VISIT OUR WEBSITE FOR MORE INFORMATION
www.gueensbury.net
Town of Queensbury - Community Development Office • 742 Bay Road, Queensbury,NY 12804
` c
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518)761-8256 Arrive: am/pm Depart: J3'.ZD: am/pm,
Date Inspection request received: J (v Inspector's Initials:
NAME: S� VV PERMIT#:
LOCATION: ",, (=�J�iWL'Z`,�T C? DATE:
TYPE OF STRUCTUIZ
Comments
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs, decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety dazing/Window in stairwells safety glazingf
Interior Smoke Detectors: ,
Every level: EFaa:
Bedroom:
Outside every bedroomInter Connected: atte r backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%z"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fire roofing/3/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker /
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/® [Temporary/Permanent]
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form—revised-1 00405.doe
Queensbury Building & Code Enforcement - Residentia Final Inspection
Office No.(518)761-8256 Arrive: am/pm Depart: '� t On/pm
Date Inspection request received: Inspector's Initials:
NAME: PERMIT#: �
LOCATION: DATE:
TYPE OF STRUC RE:
Comments
Ye No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall 01
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade "
Interior privacy/trim/doors/main entrance 36 inches ia
Bathroom/Kitchen watertight ice"
Safety glazing/Window in stairwells safety la n
Interior Smoke Detectors:
Every level: Eve edroom:
Outside every bedroom ea:
Inter Connected: Battery backup:
Carbon Monoxide Detector
-
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft,150 s . ft.vents
Bathroom Fans.if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
"o—
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/'/a hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosur
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/® [Temporary/Permanent]
L:\Building&Codes Forms�Building&Codes\Inspection Forms\Residential Final Inspection Form—revised-1 00405.doc
VgN- - /0 -/ Z --FvE-6 Z)Ay `7 -ZS--c-)L/,
Framing / Firestopping Inspection Report
Office No:.(5.18) 761-8256 Date Inspection request received: -�(O
QueensburyBuilding&Code Enforcement Arrive: am/pm art: �,�m
742 Bay Road; Queensbury,NY 12804 Inspector's Initials: � '�
NAME: �63 K— PERMIT#:
LOCATION: 1 ' � INSPECT ON: _ —
TYPE OF STRUC
WtticAccess
Y N N/A COMMENTS
22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls i
Metal Strapping for Notches Top Plate
1 %z w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq.ft. floor trusses
�- Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
0jQFire wall , 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation , L
House side %Z inch or 5/8 inch Type X j
Garage side 5/8 inch.Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
I
- s�
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: moo.) PERMIT #:
LOCATION: INSPECT ON:
TYPE -OF STRUCTURE:
Rou h Plumbing Nail Plates
lumbin . /'Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet change of direction
Pressure Test
Drain./.Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air / Head
50 P.S.I for 15 minutes
Insulation Residential Check/ Commercial Check
Proper Vent Attic Vent "
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
LAPam Whiting\Building&Codes\Inspection Fotms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
®ugh Plumbi / Insulation Inspection Report`
Office No. (518) 761-8256 Date Inspe r cyst received: G
Queensbury Building & Code Enforcement Arrive: < am/p epart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspecto s I 'tials:
i
NAME: PERMIT #:
LOCATION: 7-)6 INSPECT ON: 1 _-C
TYPE OF STRUCTURE:
- - y N N/A
9RoVlumbin / Nail Plates
Plumbing Vent / Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
eanp.utj�ve-_-100 feet / change of direction
i.,'A
Pressure Test`
Drain / Vent
Air/ Head
P.S.I. or 1_0 ft. above highest connection for 15 minutes
e sure:77est =--
Water Supply Piping
Air/ Head
50 P.S.I for 15 minutes
Insulation / Residential Check/ Commercial Check
Proper Vent Attic Vent _
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
_Duct work sealed properly / No duct toe
COMMENTS: rr
LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005
6V -j0 1110A) 6 - / Z - 06
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection r/ uest received:
Queensbury Building & Code Enforcement Arrive: am/ Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspec r' itials:
NAME: /8 r cj PERMIT #: OS--
LOCATION:— INSPECT ON
TYPE OF STRUCTURE:
,AT - :• Y N N/A A
(jR,,g�U'-'h �umbrn %" it Plates IILI>r+LL- A 41L
nt / Vents in Place
L�f
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cjeanout eve 1QQ:.f.,eet / change of direction
r.'iin �
Dra / Vent
Air / Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
lessure Test
V1l ler-Supply`-`Piping
Air / Head d ��
50 P.S.I for 15 minutes
Insulation / Residential Check / Commercial Check
Proper Vent Attic Vent
Duct / Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
uct work sealed properly / No duct tape
COMMENTS:
fis Y
Vc5c-(W?6i0
LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Foundation Inspection Report
Office No. (518)761-8256 Date Insp ction quest received:
Queensbury Building&Code Enforcement Arrive: _L!1= pm� Depart: am/pm
742 Bay Rd., Queensbury,NY 12804 Inspec or's Initials: V r—
NAME: ' PERMIT#: 0
LOCATION: a s INSPECT ON:
TYPE OF STRUCTU
Comments
N N/A
ootings
Piers
Monolithic Slab
Reinforcement in Place ✓/ a
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place f
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofmg/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfrll Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\SueHemingway\Buisding.Codes.Inspection.FORMS\Foundation Inspection Report.doe January 28,2003
V
ee'�77 /
4
Jown o Q ueensbur� )..
BUILDING and ZONING DEPARTMENT
Bay and Haviland Road, R.D. 1 Box 98
Queensbury, New York 12801
SEPTIC DISPOSAL SYSTEM INSPECTION
NAME
LOCATION
DATE,5—_6 PERMIT NO
SOIL TYPE -(Sand Loam - Clay f,
Percolation Test Required? YES NO
Percolation rate - Min/Inch
TYPE off,SYSTEM: tT 7�,,'��n�
Absorption field, total lerjth_s" `r�J�
Length of\each trench' Sip
Depth of t Benches
Size of gra T
SEEPAGE PITS{ umber of _ \
Size- ft. _ f
Gravel size
PIPING: Size Type
Bldg, to tank .r _ 1�- 5 C,igO P(r
Tank to dist. box R V C-
Dist. box to fiel,/ 19 VCr
,Openings sealed? E- NO Partial
LOCATION/SEPARATIONS:
Foundation to t4nk �ft.
Foundation to sorption C)ft.�
Absorption to of line ,eft.
Separation of its t.
LOCATION OF SYSTEM ON' PROPERT (circle one)
Front - ear d Left side - Righ side -
COMMENTS
SYSTEM USE APPROVED Y NO
Building Ins1r
ctor
01/86 and v1
Town of Queensbury 742 Bay Road, Queensbury, NY 12804
Building & Code Enforcement Building Permit 2005-934
Phone:(518)761-8256 Date: 12/20/2005
Fax: (518)745-4437'
Email: codespqueensbury.net
Dear Mr.Monroe,
Your building permit application has been reviewed and found to be deficient in the following areas.
esign loads.missing 90 mph wind load
r schedule does not list door at bottom of stairs as a 3/ hr fire door,
ofrek report is incorrect you have listed insulation continuous and cavity type it should be cavity only redo report.
Show on cross-section grade will drop 6"in first 10' away from foundation.
The stairs should be labeled with the proper run and rise with closed risers and '78"�clearanc
P
Show location of smoke detectors and carbon monoxide detector and that they are interconnected&battery backup.
7) Show handrails and guards on stairs with height and spacing requirements.
Show attic access 2nd floor roof area.
9) how entry door into existing home as per my conversation with Pam Brown, and fire door-that leads into garage.
Show slope of garage floor to overhead door.
IT
Bedroom window does not meet the required 8% light and 4%ventilation requirements. You will need to add
!another window. The required light is 13.44sf and ventilation is 6.72sf. Remember you must maintain 5.7sf egress.
L1 C'_A - r 1
\-T to Obir �=_
�JL4 17VW
Z' F O
e items must be addressed immediately. Please feel free to contact this office with any question garding this
Sinc y,
IL INCd CO OFFICE vs
VA�
rt
\\BIGRED\Users\johno\My Docmnents\Residential Plan Review. c V 1
FROM FAX NO. :5184'344543 Dec. 07 2005 12:26PM P2
�,C- CR,4,1,
Permit N=trer BWNS EC U
® 7
UppFUN��Sp ��/NGBU Mcheck Compliance Certicate Che"RyfDo 5
y
2000 IECC
Mcha*Sotware Vemion 3.6 Rdeme 2
Data flename:MHdo&mk
PROJECT TITLE William and Pam Brawn
CA'Y:Glens Falls
STAT&New Ybik
HM:76335
CONSTRUCTIAN TYPE:Single Family
WIlrMW/WALL RATIO:0.04
05 DATE
• DATE OFF PLANS: 12/fl2/05 C
PROJECT DESCRIPTION:
22a32 Garage and overlread bM/baffi ,Q
DESIOWCONTRACTOR
RDM Desips
Jon Send buildea
oo
COWLIANCE:Passes
Uvdm m UA=243 �� Q
Your Home UA=131
4&1%Betts Than Code(UA)
Gross nAn$
An&or Cavity Cont. Door
Perim lac - ilrFactorVA
Ceffing 1:Fiat Ceiling or Scissor Tmss 704 3$.0 10
Wall 1:Wood Frame. 16"o.m 176 21.0 / 5
Door 1:Solid 21 0.230 5
Wail 2:Wood 1:rane6 16"ox. 176 21.0 2
Door 2:Solid 112 0.2.30 26
W2113:Wood Frame, 16"o.a. 256 21.0 8
Wall 4:Wood Framer 16"o.c. 256 21.0 7
Door 3:Solid 21 0.230 5
Wall 5:Wood France, 16"o.G 176 21.0 5
Window 1:Wood Fraue:Uouble Pane with Low E 6 0.330 2
Window 2:-Wood Pnme:l?ouble Pane with Low-E 15 0.340 5
WOU 6:Wood Faaane, 16"ox. 256 21.0 5 8
Wall 7:Wood France. 16"ox- 176 21.0 4
Winslow 3:Wood Fnne.Double Pane with L w-E 24 0.340 8
FROM Fnx No. :9184944543 Dec. 07 2005 12:33PM P1
t
Window4:Wood Frame0ouble Pane with;.ow-E 24 0.340 8
Wall 8:Wood Frame, 16"ox. . 256 21.0 8
Floor 1:All--Wood 7oistlrms:Over Un=chttoned Sparc 704 21.0 15
CQMPLIANCS STATEMENT: The proposed building design desmibed Jim is oonshment with the building plans,
qmfiabotts,and other calculations submitted with the permit application The:proposed building has beets designed to
mad the;2m IECC nquimnenm in Meheck Venion 3.6 Release 2(bntedy MECdeed) and to Omply ruith the
VIisthe RESchju*bsperfion Checklist.
BuildedDadgner Date ' Q
I �
Community Development Office
ozon of Queensbury • 742 Bay Road • Queensbury, New York •12804
Marilyn Ryba, Executive Director• David Hatin,Director of Building&Codes
Craig Brown,Zoning Administrator
-----------------------
BUILDING PERMIT CALCULATION SHEET:
NATURAL LIGHT, VENTILATIONAND EMERGENCY EGRESS REQUIREMENTS
REQUIRED ACTUAL
ACTUAL LIGHT REQUIRED SQUARE FOOT
AREA OF ROOM IN LIGHT VENTILATION OPENING FOR REMARKS
HABITABLE ROOM SQUARE FEET 8"OF ROOM AREA SQUARE V F ROOM AREA SQUARE
FOOTAGE OF ROOM AREA FOOTAGE EGRESS
9
oLA9 to.-12—
QUESTIONS? CALL 761-8256 OR EMAIL
codes@queensbury.net
VISIT OUR WEBSITE FOR MORE INFORMATION
www.guensburV.net
B 10-LTR 11-20
I
c Community�Development Office
own ;
,
of Queensbury • 742 Bay Road • Queensbury, New York •12804
Marilyn Ryba, Executive Director• David Hatin,Director of Building&Codes
Craig Brown,Zoning Administrator
I
WINDOW SCHEDULE 10 '
JOB SITE/ADDRESS: DATE:
OWNER: APPLICATION NO.:
WINDOW-
UNIT OR CLEAR CLEAR
WINDOW STOCK ROUGH ROUGH SQ.FT. OPENING
NO.OR WINDOW SQ.FT. WIDTH IN I OPENING SPECIAL HARDWARE OR
MANUFACTURER NUMBER OPENING OPENING EGRESS/CLEAR HEIGHT
LETTER NAME MODEL/TYPE CALL WIDTH HEIGHT VENT OPENING N INSTRUCTIONS
ON PLAN SIZE INCHES INCHES
,t
i
3 DEC 2 8
Permit Number_f
REScheck Compliance Certificate Checked By ate
2000 IWC
REScheck So$ware Version 3.6 Release 2
Data fi1e'name: Untitled.rck
PROJECT TITLE: William& Pam Brown
CITY: Glens Falls
STATE: New York
HDD: 7635
CONSTRUCTION TYPE: Single Family
WINDOW/WALL RATIO: 0.04
DATE: 12/27/05
DATE OF PLANS: 12/27/05
PROJECT DESCRIPTION:
22x32 Garage and overhread bed/bath
DESIGNER/CONTRACTOR:
RDM Designs
Jon Senecal
COMPLIANCE: Passes
Maximum UA= 223
Your Home UA= 181
18.8%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Truss 704 38.0 0.0 21
Wall 1: Wood Frame, 16" o.c. 236 21.0 0.0 12
Door 1: Solid 21 0.230 5
Wall 2: Wood Frame, 16" o.c. 336 21'.0 0.0 18
Door 2: Solid 21 0.230 5
Wall 3: Wood Frame, 16" o.c. 236 21.0 0.0 7
Door 3: Solid 112 0.230 26
Wall 4: Wood Frame, 16" o.c. 338 21.0 0.0 18
Door 4: Solid 21 0.230 5
Wall 5: Wood Frame, 16" o.c. 176 21.0 0.0 9
Window 1: Vinyl Frame:Double Pane with Low-E 5 0.330 2
Window 2: Wood Frame:Double Pane with Low-E 20 0.340' 7
Wall 6: Wood Frame, 16" o.c. 256 21.0 0.0 14
Window 3: Wood Frame:Double Pane with Low-E 14 0.340 5
Wall 7: Wood Frame, 16" o.c. 176 21.0 0.0 8
Window 4: Wood Frame:Double Pane with Low-E 21 0.340 7
Window 5: Wood Frame:Double Pane with Low-E 21 0.340 7
Wall 8: Wood Frame, 16" o.c. 96 21.0 0.0 5
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been designed to
meet the 2000 IECC requirements in REScheck Version 3.6 Release 2 (fonnerly MECcheck) and to comply with the
mandatory requirements in the REScheck Inspection Checklist.
Builder/Designer L' Date v2 0! DS
Cq
�o
�.---.-.-----,
Co�nmujeity Development Office ■
own of Queousbury■ 742 Buy Rood• Queensbury, New York •12804
Marilyn Ryba,Executiue Director•Dwid Hatin,Director of Buildi Fag is Codes
Crrig Brown,Zo►ringAdminis[rator •
r
WINDOW SCHEDULE ----
JOB SITE/ADDRESS: DATE:
OWNER: APPLICATION NO.:
MlINDOYu'- WINDOW UNITOR CLEAR CLEAR
STOCK ROUGH ROUGH SOFT. OPENING
NO.OR WINDOW SG1.FT. OPENING SPECIAL HARDbYARE OR
h1ANUFACTURER NUMBER OPENING OPENING EGR5SS+CLEAR HEIGHT
LETTER NAME MODELf1YAE CALL WIDTH HEIGHT ANT OPENING WIDTH IN IN INSTRUCTIONS
�`l PLAN NAMEES INCHES
c�
ANflcr�s� W,32 ' 029 33�/
A MJbEks(50 Tw 3a3� 3t�/,� 38�$, `{,32 � 29 337/g /SYS"
A A-NbERS TV q, 29 337��e
r
AY0b fZSe-rJ -TW 30 .3,2'� �85�8 �,�3 5, *7 3 z4
oo
d
w —
o�
w
F '
1
o `
N
0
N
N
ri
r
= r
z r _ Corrrmunity Development Office •
own ofQueensbury - 742 Bey Road• Queensbury, New York •12804 < <
Marilyn Ryba,Earcu ive Director- David Hatir?,Director orBrrildirrg&Codes
Creig Brcwn,Zoning Administrator 0
'----- ------
BUILDING PERMIT CALCULATION SHEET:
NATURAL LIGHT', VEN7TLA7'-IQNAND EMERGENCY EGRESS REQUIREMENTS
REQUIRED i ACTUAL
ACTUAL LIGHT REQUIRED ! SQUARE FOOT
AREA OF ROOM IN LIGHT SQUARE VENTILATION OPENING FOR REMARKS
HABITABLE ROOM SQUARE FEET V OF ROOM AREA SQUARE w A SQUARE
FOOTAGE OFF ROC1OO ION M AREA.EA, FOOTAGE EGRESS
a
2-7
t Sr 7 7
0
I
I
i
w
�r
F
? QUESTIONS? CALL 761-8256 OR EMAIL
codesOoueensb ru v riet
o VISIT OUR WEBSrTE FOR MORE INFORMATION
wwri auensb urV.rret
�+ B 10-LTR 11-20
r