2005-937 TOWN OF QUIEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE O.F COMPLIANCE Permit Number. P20050937 Date Issued: Wednesday, December 13, 2006 This is to certify that work requested to be done as shown by Permit Number P20050937 has been completed. Tax Map Number. 523400-227-013-0002-041-000-0000 Location: 84 ROCKHURST Rd Owner. STEPHEN KIRSHON Applicant: STEPHEN KIRSHON This structure maybe occupied as a: - - Demolition By Oder of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals.' TOWN OF QUEENSBURY 742 Bay Road,Queensbuiy,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20050937 Application Number: A20050937 Tax Map No: 523400-227-013-0002-041-000-0000 Permission is hereby granted to: STRPHF,N MRSHON For property located at: 84 ROCKHURST Rd in die Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tyne of Construction Value Owner Address: STEPHEN KIRSHON Demolition 22 DALLAS Dr Total Value POUGHKEEPSIE, NY 12603-0000 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2005-937 DEMOLITION OF SINGLE FAMILY DWELLING $20.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday, December 15, 2006 (If a longer period is required,an application for an extension mnst be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tow q of ue nsbu ; T As y, December 15, 2005 SIGNED BY for the Town of Queensbury. Director of Building&Code EnIcement Permit No. P W Application for Demolition Permit Fee Paid A .Do Building&Code (Office—,—, b n of;gue sbury 742 Bay Road Queensbury,NY 12804 (518)761-8256a�'a`� p�. 1' �� S Notes: _Instructions/Re uirei G Ar2 tw it: Fill in all applicable spaces and submit two(2)plot plans,drawn to scale,showing lot boundaries with dimensions and adjacent roads/streets. Show all exisQlglsfrh^ctu'tes.:oIi flie p�,op sty and indicate which are to be demblished.iIndioate on the plot plan the location of all utilities. �DGU''� T�. -- UiiLil,.. a ,-� `` rz `1� �e c {C) z�7.'ersouRe_`s`onsibletorWot�k F Name Jt Gar Addresst � rifl mx < Isv"%-- ' S 2. Location of demolition: `�� ��r� 3. Tax Map No. 4. Where will demolition material be disposed of? 5. Asbestos Information A copy ofAsbestos Removal Report must be filed with our office before demolition begins. a. Is there any asbestos within the building to be demolished? ❑Yes %No If YES, our office needs the following information: b. Name of firm removing asbestos: C. License number of firm:- d. Indicate location where asbestos material will be disposed 6. Structure Information a. In cate which structure(s)will be demolished: esidence; ❑garage; [storage building; ❑business; Mother b. Size of structure: '�-i; ft.by ft. C. Number of stories ')- d. Foundation type: ❑full cellar; 191crawl space; ❑slab e. Foundation: ®will be removed; ❑will not be removed f. Structure(s): [`will be replaced; ❑will not be replaced 7. Utilities Information Indicate utilities for this structure: ❑gas electric ❑propane TAonsite well-water pump ❑public water ❑public sewer Have you notified the Town Water Dept, for public water and public sewer disonnect? ❑Yes ❑No Have all utilities been disconnected? ❑Yes UNo Qa,J�S \„ \-.e- ,Dc_tkk Signature of Applicant: Date: \ — Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/pm epart: am/pm Date Inspection request received: Inspector's Initials! ,/ NAME: G PERMIT#: LOCATION: -6t-4 up,57- -0 DATE: �� TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate _ Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(het ht)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp, 110 Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched �(�'�►v Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/® [Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc Framing /Firestopping Inspection Report Office No. (518) 761-8256 Date Ins ctio quest received: Queensbury Building&Code Enforcement Arrive am/ part: am/pm 742 Bay Road, Queensbury,NY 12804 Inspecto 's"Initials: NAME: ��?��n'J PERMIT#: v LOCATION: INSPECT ON: Z 1 c o� TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Attic Access 22"x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls /-IAkb Metal Strapping for Notches Top Plate 1 '/s(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side `/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Qa �. EROSION & SEDIMENT CONTROL NOTES BEFORE ANY CLEARING OR GRUBBING OF THE SITE IS INITIATED, AND DURING _ EARTHWORK PHASES, SEDIMENT TRAPS SHALL BE CONSTRUCTED IN ALL STORM SWALES AND DITCHES AND AS INDICATED ON THE PLAN. �.�KE "0RGE �.�XE C�02G� DEC a�5 2. SEDIMENT TRAPS SHALL CONSIST OF HAY BALES PLACED TO FORM A ""PERVIOUS BARRIER IN THE SWALE OR DITCH. 3. AT LEAST TWO WOODEN OR METAL STAKES SHALL BE DRIVEN THROUGH DOCK DOCK EACH BALE TO ANCHOR IT IN PLACE, CONVENTIONAL SNOW FENCING MAY BE USED IN LIEU OF STAKES TO STABILIZE BALE TYPE SEDIMENT TRAPS. 4. AFTER EVERY STORM EACH SEDIMENT TRAP SHALL BE INSPECTED FOR FAILURES OR CLOGGING, AND ANY FAILURE OR CLOGGING SHALL BE i DOCK 't` DOCK IMMEDIATELY CORRECTED. 5. ALL BARE EARTH AREAS SHALL BE SEEDED AND MULCHED AS SOON AS IS POSSIBLE TO PREVENT EROSION, AND EVERY BARE EARTH AREA SHALL BE SEEDED AND MULCHED AS SOON AS PRACTICAL. TEMPORARY RAPID GROWTH COVER CROPS, SUCH AS ANNUAL RYEGRASS MAY BE USED FOR TEMPORARY SURFACE STABILIZATION. _„„_,S14°04'471N_9$.09' �-�_' ""--_' '--- --.-_._ S14°04'47"W 98.09' 6. SMALL BENCHES AND TEMPORARY INTERCEPTOR DITCHES INCORPORATING (TIE LINE ONLY) --�— __ (TIE LINE ONLY) SEDIMENT TRAPS, SHALL BE CONSTRUCTED WHERE LONG SLOPES ARE STRIPPED - OF COVER GRASSES, OR WHERE FILL AREAS ARE EXTENSIVE. LOT AREA —11,991 SFf 7. NEW SWALES AND UNLINED DITCHES SHALL INCORPORATE MATTING OR �c NETTING OVER SEED AND MULCH WHEN THE INVERT SLOPE EXCEEDS 2%0. ALL a LAWN SWALES AND UNLINED DITCHES SHALL BE SEEDED WITH REED-CANARY GRASS 50.0' FOR FOUR(4) FEET EITHER SIDE OF THE SWALE OR DITCH CENTERLINE, AT A 0 42.5' o RATE OF 25 POUNDS per ACRE AFTER JUNE, ALL SEEDED AREAS SHALL BE MULCHED WITH STRAW IMMEDIATELY. N b /---- SF SF SF SF — SF' —SF SF ---��� PROPOSED LIMIT OF DISTURBANCE, 5660 SFt 8, THE CONTRACTOR SHALL COMPLY WITH THE NEW YORK GUIDELINES FOR \\ URBAN EROSION AND SEDIMENT CONTROL AS PUBLISHED BY THE EMPIRE STATE S� PROPOSED SILT FENCE CHAPTER OF THE SOIL AND WATER CONSERVATION SOCIETY. a� SLATE PATIO AREA--1064 SF PROPOSED 2' WIDE, 4' DEEP, STONE FILLED ZONING INFORMATION N► EAVE TRENCH; 185LF, AREA OF PROPOSED BUILDING - ZONE WR-1 A 590CFf VOLUME 50 c LIAKE SHACK _ Ln n 50,L4KF 5� , ZONE WR-1 A - WATERFRONT RESIDENTIAL CK 1-4z c SETBACKS - 30' 0 ROAD, 50' SHORELINE, 20' SIDE 22 3, �! N^ MAX BUILDING HEIGHT - 28' nNi ' N ^;m N 00 u, EXISTING „� � N G COVERAGE o z 0 TOTAL AREA = 11,991 SF = 0.275 ACRES z a ' Nn z TOTAL IMPERMEABLE AREA = 5164 SF F- Y AREA OF PERMEABILITY = 6827 SF LAWN — PERCENT PERMEABLE = 56.9% WSTING HOUSE 20.0' 1756 SF FO4-rpRINT ' PROPOSED HOUSE PROPOSED 4" SCH-40 PVC HOUSE SEWER; 1/4" PER FT. MIN SLOPE z 1582 SF FOOTPRINT POSED COVERAGE __,_ � -_______ • .A • ( 0 3' TOTAL IMPERMEABLE AREA = 5510 SF RES rn PVCPEFFLUENT SEWER; 1/8" PER FT. MIN SLOPE AREA OF PERMEABILITY = 14,704 SF Ul " ? { -PROPOSED 1250 GAL PERCENT PERMEABLE = 72.7% SEPTIC TANK TOTAL DISTURBED AREA = 5400 SF 21.5' _o POSED " N DISTRIBUTION BOX PROPOSED 2 SDR-11 ` SIDEINA1:4 HDPE FORCE MAIN SIDEWALK — 492 SF' 198 SF 3V FRONT SETBACK — a LAWN .o � LAWN 36J' 34.8' 00 20.0 SF� QQJAXE A=140 SF 100 SETBq`+ 4 f _1 c CONCRETE RETAINING WALL 50 SF I SETBA CONCRETE RETAINING WALL 50 SF /ca m ��- -", ' PROPOSED 32' / CONCRETE CURBING i . `+! PROPOSED ASPHALT ' 1155 SFt Q E C 0 9 R 0 D 4 0 OS EN'CIVEL EN, 2005 C N E C B G IN D IN E` S D FIL R N09°22'3 "E 38.81' NI A 2 N09°22'34"E 38.81' E S F 7 S N17°08'45"E 59.50 N17008-45"E 59.50' E 0,F t <. ROCKH U RST ROAD ROCKH U RST ROAD t SITE PLAN-EXISTING CONDITIONS PROPOSED SITE PLAN & EROSION CONTROL PLAN SCALE: 1"=10' SCALE: 1"=10' ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. STORMWATER DESIGN AREAS STORMWATER DESIGN CRITERIA SITE SETBACKS TOTAL LOT AREA 11,991 SF TOTAL DISTURBED AREA 5660 SF REQUIRED EXISTING CONDITION PROPOSED 0 ISSUED FOR APPROVAL 12/6/2005 EXISTING IMPERVIOUS AREAS PROPOSED IMPERVIOUS AREAS CHANGE IN IMPERVIOUS AREAS N o. Revisions TOTAL INCREASE IN IMPERVIOUS (1863 SF) - NET DECREASE Date LAKE So' 42.5' So.o' E HOUSE 1756 SF 1582 SF (174 SF) XISTING & PROPOSED SITE PLANS ASPHALT 1844 SF 1155 SF (689 SF) QUEENSBURY SIZING CRITERIA - 147-9(A) 1.5 GPD/SF INCREASE FRONT 30' 36.7' 34.8' prepared for SHED 140 SF 0 (140 SF) RETENTION VOLUME REQUIRED 0 NORTH SIDE 20' 22.3' 20.0' Stephen Kirshon SIDEWALK 198 SF 192 SF (6 SF) SOUTH SIDE 20' 21.5' 20.3' 84 Rockhurst RETAINING WALLS 162 SF 162 SF 0 RETENTION VOLUME PROVIDED (STONE EAVE TRENCH) 590 CF MAP REFERENCE Town of Queensbury,Warren County,New York PA110 1064 SF 0 SF (1064 SF) PROPERTY LINES AND BOUNDARY Drawn: LWD Checked: GTH Scale: 1"=10' Date: 11/9/05 TOTAL IMPERVIOUS 5164 SF (43.06%) 3091 SF (25.78%) (2073 SF) (DECREASE) INFORMATION TAKEN FROM "SURVEY MAP MADE FOR STEPHEN KIRSHON" DATED 169 Haviland Road TOTAL PERVIOUS 6827 SF (56.94%) 8900 SF (74.22%) 2073 SF NOVEMBER 16, 2005, PREPARED BY: ZAREH Queensbury, NY 12804 29131-01-S 1 ALTOUNIAN, LLS, LOUDONVILLE, NY Hutchins Engineering (518) 745-030 Phone g (518} 745--03 0 g 08 Fax POLYETHYLENE EXTENSION TO APPROXIMATE GRADE WITH TAMPER POLYETHYLENE EXFENS10N TO OVERFILL TO ALLOW SETTLMENT FINISH GRADE RESISTANT ACCESS COVER INSTALL FLOAT SWITCHES TO OPERATE PUMP GRADE WITH TAMPER & TO DIVERT STORMWATER AND MAINTAIN LEVELS AS INDICATED RESISTANT ACCESS COVER 12" t COVER AWAY FROM SYSTEM 4" MIN. TOPSOIL, ESTABLISH TURF INSTALL ZABEL A1800 FILTER 12"t SUCH THAT IT IS READILY DISBRIBUTION BOX 4" SCH 40 PVC REMOVABLE THROUGH TANK EXPLOSION PROOF JUNCTION PERFORATED PIPE a ACCESS COVER BOX. INSTALL CONTROL 8" MIN 12-18" 4" SCH. 40 PVC 3" PANEL IN HOUSE ® GEO-TEXTILE COVER INLET 4" PVC SCH-40 LIQUID LEVEL OUTLET BAFFLE-" CONCRETE SAND MIN. SLOPE NA 2" SDR 11 1/4" PER FOOT MIN. SLOPE HDPE FORCE:MAIN USE SPEED LEVELERS TO IN-DRAIN UNIT 15" 1/8 PER FOOT ASSURE ALL OUTLETS ARE AT 7n 18"MIN. EXACTLY THE SAME ELEVATION WATERTIGHT SLEEVE ALARM - 6" :. -" 4" PVC SCH-40 SOLID HEADER TO � <"� ��•• - _ ABOVE 'PUMP ON' 3-4" VOLUME OF DOSE " 777, AND SEAL TYP. .._ :- ,- :. .. . . _. .-: ..,. ._.... :. .. -,:,.:-: •. .:. ;....:. ( ) t- PERFORATED TRENCH PIPING, 1/8 HOLES 0 5&7 O'CLOCK--------"" " TO BE 60f GALS - 6 MIN a_ x " P FO T MIN SL E z PUMP ON ER 0 OP w � ¢ � : .� - - 2 SCH 40 PVC OR � ' ` " - o GALVANIZED PIPING INSIDE , :. ti:.,... .. ;.. '.=:"•;,::::. ;. ; :, o o PUMP OFF • WET WELL THROUGH WALL 1000 GAL PRECAST "� crD ZABEL A1800 CONCRETE SEPTIC TANK SERIES FILTER 12" MIN. 6" MIN 36" 6" MIN GATE VALVE' MINIMUM 2X WIDTH + .. REDUCING TEE POINTED EVEN IN-DRAIN TRENCH SECTION MAXIMUM 4X WIDTH DOWNWARD WITH 1" BALL VALVE PUMP STATION NOTES CHECK VALVE THROTTLED TO ALLOW TRICKLE SEAL ALL TANK OPENINGS WATERTIGHT. NTS • .. . ,. : 4. . +" DRAIN BACK INTO WETWELL 750 GAL PRECAST CONCRETE PROVIDE AND INSTALL UL LISTED PACKAGED PUMP CONTROL PANEL WITH VISUAL AND SEPTIC TANK NOTES SIMPLEX EFFLUENT PUMP TANK AS HOLDING/PUMP TANK UNION - LOCATE SUCH THAT AUDIBLE ALARM. INSTALL CONTROL PANEL INSIDE HOUSE IN ACCESSIBLE LOCATION. ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK STATE GOULDS 3885 UNION CAN BE DISCONNECTED DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE: AS WE0512H 230V AND PUMP REMOVED WITHOUT INSTALL POWER & CONTROL WIRING TO CONTROLLER WITH ALARM IN HOUSE IN MANUFACTURED BY FORT MILLER OR EQUIVALENT. SINGLE PHASE TANK ENTRY ACCORDANCE WITH NATIONAL ELECTRIC CODE (N.E.C.) REQUIREMENTS. ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE. SET ALARM LEVEL 6" ABOVE "PUMP ON." 10'-0" O.C. MAX. WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE PLACED AS NECESSARY TO ACHIEVE A STABLE BASE. LIQUID VOLUME BETWEEN "PUMP ON" AND "PUMP OFF" TO BE 60t GALLONS. 36" FENCE POST SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF EXTRA HEAVY PUMP TO BE GOULDS MODEL 3885, WE0512H 23OV, SINGLE PHASE, DRIVEN MINIMUM 16" CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING. QQ�� 35 GPM PUMP AT 20 FT HEAD. INTO GROUND ALL JOINTS MUST BE SEALED. SEPTIC TANK & PUMP STATION DETAIL VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO PURCHASING PUMP. SILT STOP EMBED IN GROUND NTS 8" MIN. OD 32' ELJEN IN-DRAIN TYPE B SAND FILTER UNIT TRENCH , SOIL BACKFILL SHALLOW SCALE TO CREATE POSITIVE DRAINAGE AROUND 4" TOPSOIL COVER ABOVE SYSTEM ABSORPTION FIELD FILL; SEED & ESTABLISH TURF �'� _PERSPECTIVE PROPOSED ASPHALT PARKING CONCRETE CURBING EXISTING CONCRETE RETAINING WALL 36" FENCE POST GRANULAR SYSTEM FILL 5' TO CENTER OF TRENCH —�' WASTEWATER SYSTEM DESIGN SYSTEM INSTALLATION NOTES ROCKHURST ROAD ` , ` W - o SILT STOP 4 BEDROOM RESIDENCE CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN N EMBED IN GROUND WATER SAVING FIXTURES (1.6 GPF MAX. FLUSH, 3.0 GPM MAX. FAUCETS) ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL FLOW 8" MIN. I -- I^ i !__; I _I1 I_,-=1 { j—! 1 ICI �_ i !-- , , �, I (=-' I �=' � • � - . -- - - —.., ,- HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF THERMOPLASTIC .� _ D`SIGN FLOW - 110 GPD/BEDROOM - NYSDOH CRITERIA - i SYSTEM DESIGN FLOW - 440 GPD PIPE AND CORRUGATED TUBING IN SEPTIC TANK. LEACH FIELDS. � zUNDISTURBED SEPTIC TANK - 1250 GAL GROUND THIS DESIGN UTILIZES ELJEN CORPORATION TYPE B IN-DRAIN GEOTEX11LE PUMP STATION - 750 GAL - - SECTION " LEACH FIELD ELJEN IN DRAIN TYPE B GEOTEXTILE SAND FILTER UNITS SAND FILTER UNITS INSTALLED IN TRENCH CONFIGURATION. INSTALLATION �— } 48 SYSTEM DESIGN PERCOLATION RATE IN FILL MATERIAL= 1-5 MIN/IN SHOULD BE IN ACCORDANCE WITH THIS DRAWING, NYS DEPARTMENT OF 3' FILL HEALTH REQUIREMENTS, AND MANUFACTURERS INSTRUCTIONS. APPLICATION RATE= 1.2 GPD/SF SILT FENCE ABSORPTION TRENCH AREA REQUIRED: 367 SF DETAIL QDISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT NTS - --; ELJEN IN-DRAIN TYPE B UNITS PROVIDE 6 SF LF _ SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. 62 LF OF ELJEN IN-DRAIN TYPE B TRENCH REQUIRED -- ! USE 16 ELJEN IN-DRAIN TYPE 6 UNITS 4' LONG EACH UNIT) DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER USE 2 TRENCHES AT 32 LONG (8 UNITS EACH TRENCH) _ 64 LF TOTAL TO BE PROVIDED IN DRAIN UNITS HAVE BEEN INSTALLED. Ti Jfi -,-1 ;__� ! I_i � i ► ;- III ! f-_I ! ! __ III I-__ II-- 1t !---i ! i --, , ►- it = 1I �! , ,__I � I _! ! II —i i I -- ' E--i — I POTABLE WATER SUPPLY TO BE LAKE GEORGE LAKE WATER ABSORPTION TRENCH NOTES ---! ► !—, =i I -- I I=i ! ►--� ,= !-- ! — — � — I=! : — 11— i —. I_-_E __ ____ I .— -- MIN. SEPARATION FROM SEPTIC TANK TO LAKE = 50 THIS DESIGN UTILIZES ELJEN IN-DRAIN TYPE B GEOTEXTILE SAND FILTER 12' WIDTH OF EXCAVATION MIN. SEPARATION FROM ABSORPTION FIELD TO LAKE = 100' UNITS INSTALLED IN A TRENCH CONFIGURATION. REMOVE EXISTING FOR SYSTEM FILL ASPHALT IN THE AREA OF THE PROPOSED ABSORPTION FIELD. AN AREA SITE SOILS DATA 12' WIDE BY 4' DEEP IS TO BE EXCAVATED OVER THE ENTIRE LENGTH ABSORPTION FIELD SECTION TEST PIT OF THE ABSORPTION TRENCHES AND BACKFILLED WITH CLEAN SYSTEM IPA - 10/31/05 BY T. HUTCHINS FILL USE TRACKED EQUIPMENT FOR ALL WORK IN ABSOPRTION FIELD SCALE: 1"=2' 48" DEPTH AREA. ABSORPTION TRENCHES TO BE EXCAVATED IN STABILIZED SYSTEM FILL ABSORPTION TRENCHES TO BE BOTTOM OF TRENCH 0-2" ASPHALT (BOTTOM OF CONCRETE SAND) TO BE INSTALLED AT 25-31" BELOW 2-4" CRUSHED STONE EXISTING GRADE. 4-12" GRAVEL FILL 12-22" SILT LOAM 22-48" SILTY CLAY LOAM FILL MATERIAL NOTES LOAM, SEED AND MULCH ALL 6" 1 1/2" R AFTER EXCAVATION OF INCONSISTENT NATIVE SOILS OVER THE AREAS SPECIFIED, DISTURBED AREAS DRY ENTIRE DEPTH OF PIT BACKFILL EXCAVATED AREA WITH SYSTEM FILL MATERIAL SYSTEM FILL TO BE BASE COURSE NO SEASONAL HIGH GROUNDWATER EVIDENCE LOAMY SAND FILL WITH IN-PLACE PERCOLATION RATE OF 3-5 MINUTES. FILL INCONSISTENT FILL SOIL THROUGHOUT ENTIRE DEPTH OF TEST PIT TO BE STABILIZED IN 6" LIFTS TO MEET EXISTING GRADE. PAVEMENT PERCOLATION TEST PT-1 - 10/12/05 BY T. HUTCHINS `0 18" DEPTH SILT LOAM & SOME GRAVEL FILL SUITABLE UNDISTURBED NATIVE MATERIAL zoo STABILIZED PERCOLATION RATE = 2 MIN/IN ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL OR BACKFILL WITH COMPACTED GRANULAR 2 ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. MATERIAL Q 12- POURED C;?�E IN PLACE CONCRETE CURB EXPANSION JOINTS AT 8' INTERVALS 0 . .. a D. nn $;, 0 ISSUED FOR APPROVAL 12/6/2005 iv 12" COMPACTED BASE COURSE p Q N o. Revisions Dote NYSDOT ITEM 4 .0 DETAIL SHEET prepared for CURB DETAIL - POURED IN PLACE Stephen Kirshon NTS 84 Rockhurst NOTE: USE EITIER POURED IN PLACE CURB, OR PRECAST CIRB SET IN PLACE Town of Queensbury, Warren County, New York Drawn: LWD Checked: GTH Scale: 1"=10' Date: 11/9/05 169 Haviland Road Queensbury, NY 12804 Hutchins Engineering (518) 745-0307 Phone 29131-01-S2 g g (518) 745-0308 Fax