Loading...
2004-006 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20040006 Date Issued: Friday, December 30, 2005 This is to certify that work requested to be done as shown by Permit Number P20040006 .has been completed. Tax Map Number: 523400-296-009-0001-050-000-0000 Location: 11 TWICWOOD Ln Owner: STEPHEN &ROBYN MAGEE Applicant: STEPHEN &ROBYN MAGEE This structure may be occupied as a: Residential Addition By order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the d property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040006 Application Number: A20040006 Tax Map No: 523400-296-009-0001-050-000-0000 Permission is hereby granted to: STF.PffF,N&ROBYN MACTEE . For property located at: 11 TWICWOOD Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: STEPHEN&ROBYN MAGEE ' 11 TWICWOOD Ln Residential Addition $25,000.00 . Total Value $25,000.00 QUEENSBURY, NY 12804 Contractor or Builder's Name /Address Electrical Inspection Agency DA2B BIJILDERS LLC 85 ELM St FRJDSON FALLS_ NY 12839-0000 Plans&Specifications A2004-006 224 SQ FT RESIDENTIAL ADDITION $75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday, January 29, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Thursday, January 29, 2004 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Project Naive: BP# Address: ��i� ; Budding Pernut Submission SFD Checklist 2-Family All items below must be checked either yes,no or not applicable prior to submission of any building permit to the Town of Queensbury Building Department. If any of the below items are lacking,the permit will not be accepted until such time as the application is deemed complete for submission. nf 1. Building Permit Application Completed ..................................... ❑no ❑n/a 2. EnergyForm or Checkhdate Energy Code Compliance Foam Complete.. j4yes ❑no ❑n/a (2 copies) 3. Energy Code Inspector's Report from CheckMate Program..... ........... es ❑no ❑n/a (2 copies) 4. Septic application completely filled out(if applicable)........................ ❑yes ❑no Aida S. Solid Fuel Burning or Gas Appliance Form... ...... []yes Ono Nda 6. Electrical Inspection Form... ...... ... ... ................................. ... ..... ❑yes ❑ao Oda 7. Two(2)complete sets of structural drawings.:......... ..................... ....Lqves Ono On/a a)floor plan;b)foundation plan;c)cross sections:d)elevations; e)window and door schedule S. Two(2)site plans showing location of the stricture to be built....... ...... Pyes Ono Oda location of well or water lines,location of septic system or sewer line. 9. Setbacks from property lines to new structure......... ..................... .. Dyes Ono Wa 10. Setbacks to neighboring wells and septic systems,including onsite well.... Dyes ❑ao [ a/a and septic systems(if applicable) 11. DrivewayPenmit.................. ... ...... ... ......... ..................... ...... Dyes Ono On/a yv- Date: i Staff Initial: L:\Suctieming-%tray\Buildingl'erau'c-FOF'\MS\Generic ChccHse-doc January 28,2003 Building Permit Application Town of Queensbury.—Dept of Community Development,742 Bay Road,Queerisbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No. Q� No inspection will be made until applicant has received a Fee Paid $ Y75, valid building permit. All applicants' spaces on this Roc,Fee Paid $ application must be completed and must appear on the Reviewed By: application form. ''. Applicant: ,��' & /��/�!r S l owner: poi sk z�b/o Address: Address: u>/e FIVE Phone#( ) - a Phone#( ) 4'�z- or`5/d� JAN ® 9 2004 Property Location: Lot Number: / House Number / MM nc QUEENSBURY Subdivision Name: i�ir�1c u»6u?� Tax Map Number: BUILDING AND CODE n New Building: residence /commercial 'Estimated Market Value of Construction: $_,eS) M Addition: esi once commercial If an d 'tion,what will use of new addition be? 0 Alteration: residence/ commercial �gy� P�,2.� )d 0 No change to exterior size: residence/com'1 o Other work(describe ) Check occuponcyWormation V Floor 2° Floor Other floor Total Below sq.ft. sq.ft, sq,ft. Square Feet 14 Single*=dly dwellin ci Two family dwelling v Townhouse o Multifamily dwelling #of units o Office o Mercantile o Manufacturin 1 car detached garage D 2 car detached garage 0 3 car detached garage a 1 car attached garage 0 2 oar attached garage v 3 car attached garage C Storage building- commercial o Storage building- residential a Other :. ?' ' 7 ^ /e,z What is the proposed height of the structure feet inches Will any second-hand or ungraded lumber be used? If so,for what? JJ � Type of Heating System: electric/ oil / gas/wood orced hot a' / baseboard/other: 15T I✓1. Number of Fireplaces to be installed 11 Number of ffgodseoyes to be installed List below the person(S)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder 4 C &h >?J 79Y 37��— fig Plumber e� Mason Electrician Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with.the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall , submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and'Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual location of Lall4eyvconstructionsSignature: / C i owner,owner's agent,architec contractor Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 / Arrive: am/pm Depart: �Y�` m Date Inspection request received: a' 0 Inspector's Initials: �[ NAME: J� e — l PERMIT#: l '00 LOCATION: DATE: O TYPE OF STRUCTURE: v' fL� Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches � D Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interiog Exterior Railings 34 inches to 38 inches V/ Interior Handrails @ stairs 2 or more risers V Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertiglit Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x n-ac le area Crawl Spaces 18 inch x 24 inch acc ss, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s . ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification, if required Okay to issue C/C or C/0 [Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc Queensbury Building & Code Enforcement - Residential Final Inspection Wice .(518)761-8256 Arrive: arn<Vpar . am/(9 Date Inspection request received: Inspector's Initials: NAME: --3�P 4V,�T : 0 D LOCATION: �N , 1 r tYx>� TYPE OF STRUCTURE: cC.n Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in. or more a)stairs, decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete krwTj&/Exterior Railings 34 in.to 38 in. Platform at all exterior doors L�T�s 6P I riar Handrails stairs 2 or more risers Gypsum sum Stairs Sheetrock Underside minimum %2" Grade away from foundation 6 in. with 10 ft. V Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 �(� Interior privacy/trim/doors/main entrance 36 in. (/ Bathroom/Kitchen watertight ,�j Safetyglazing/Window in stairwells safetyglazing N� Interior Smoke Detectors: � Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector L/ Bathroom Fans, if no window OePlumbing fixtures Foundation insulation C.DvEBE Floor truss,draft stopping finished basement 1,000 sf Emergency egress below rade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl S aces 18"x 24"access, 1 s . ft.-150 s . ft. vents Buildin No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification if required Oka to issue C/C C/O)Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res. Final Inso. form 2.docLast printed 2/12/04 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.0 Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL 0r .......................................Permit No. Cert. N® 75928 Cut-in Card No...........................`. Owner.......... ..a...... ... � , ' s,. Location.....,l.E......7m a 'Q Installation Consistingof L.............................. ................................... ................................. .................... JG .............................................................................................................................. ............................ :)..................... ........................................................... ............................................................... Installed By......✓.........y.��G'.#—......................................Lie.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of AM i spections at any time, and if its rules are violated,the Company shall have the right t re ke thi certificate. Date............................1..................... INSPECTOR........:...........t......................................................................... Member N.F.P.A.,I.A.E.I. Rough Plumbing Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p m/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT #: 0 UI ock) LOCATION: INSPECT ON: _ TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping C( ooperii, 00per Commercial gip, CPVC,Pex One and Two-Family ` Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces mbustion Air Supply for Furnace uct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doe November 17,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: S _ Queensbury Building&Code Enforcement Arrive: am/p e rt: L_am/pm 742 Bay Road,Queensbury,NY 1.2804 Inspector's Initials: `� /lie' .- C/ 01 NAME: \ ' �--� PERMIT#: [ ~~(-� (2 LOCATION: XQ, I INSPECT ON: (� TYPE OF STRUCT Y N N/A COMMENTS aming 1� Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour 'Fire wall 2, 3,4 hour Firestopping �,� ,- 4 1 Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 11/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilin hwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\,SueHemingway\Building.Codes,Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003. Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: IL Queensbury Building&Code Enforcement Arrive: am/pJ ,.,/ Depart: - m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: JG/ NAME: PERMIT#: LOCATION: kt nLh�\C— b,� , INSPECT ON: O TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour /11einforcement in Place Foundation Dampproofing - Foundation/Waterproofing Type of Dampproofing/Watel proofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.Inspection.FORMSToundation Inspection Report.doc January 28,2003 S f� Foundation Inspection Report Office No. (5113)761-8256 Date Inspection request received: �( Queensbury Building&Code Enforcement Arrive: amp/ Depart: " pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:`� /`Q NAME: _ L-Z- PERMIT#: LOCATION: / ) ECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place r Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing et area under slab Backfill Approval) Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Glade 6 inch drop within 10 ft. L:\SueHemingwaylBuilding.Codes,InspectionTORMS\Foundation Inspection Report.doc January 28,2003 �1 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request' ecfv _ Queensbury Building&Code Enforcement Arrive: am/prr} Depart: m/ 742 Bay Rd., Queensbury,NY 12804 Inspector's Initialer:' NAME: $ERMIT#: LOCATION: INSPECT ON: LI --Irl TYPE OF STRUCTURE: �— Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. M rials for this purpose on site. undation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (5IS) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ ep : I/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: � NAME: G�. � � PERMIT#: LOCATION: INSPECT ON: LIIII19 1 TYPE OF STRUCTURE: P omments _ Y N N/A Footings Piers Monolithic Slab Reinforcement in Place 2 The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place • Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas raider slab Bacicfill Approval t Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 o Engineering Evaluation of Residential Building Plans Submitted by: Doug French, Da2B Builders, LLC 5 sheets for: Magee Addition, Twicwood Lane, Queensbury, New York 1. This is a single story one-room addition to an existing residence. 2. Floor joists 2"x10", 16" O.C. (span = approx. 13ft.) are suitable for supporting a total dead and live load of 50 PSF. 3. Roof support is by 2"x10"rafters, 16" O.C. with 2"x8" ceiling joists, 16" O.C.. The new roof will - match the pitch of the existing screened-porch roof and will be rubber covered. 4. The frost walls for the addition will be 8" poured concrete on 16"x10" reinforced concrete footings and keyed to the footings. Bottom of footings will be at least 48"below grade. The new 8" frost walls shall be doweled to the existing basement walls at top, bottom and midpoint of the new 8"frost walls. 5. A 2"concrete slab will be poured under the addition, with its top surface matching the elevation of the existing septic tank. The existing septic tank will adjoin the room addition ---no basement in the addition, though. 6. The new header for supporting the second floor joists (span = 16ft.) is labeled as 1 3/a" x 9 %2" Versa-Lam members. This beam must support 1/2 of the 2°d. floor load, %2 of the new roof load, the existing side wall and a portion of the existing roof load. This beam should be a 4-member beam using a double 1 %" x 9 Y2" LVL for the 2°d. floor hangers and a double 1 %" x 14" LVL to support the roof and wall loads. The two double beams are to be securely fastened together to act as one continuous beam(bottoms of LVL at same elevation). The existing wall should be fastened to the double 14" members also. Each end of the new one-piece beam must be supported with wood construction capable of supporting an axial load of 10,000 lbs. (each end). 7. The double 1 %" x 9 Y2" LVL header over the large window in the East wall of the new addition will satisfactorily support Y2 of the new roof in a ground snow load area of 70 PSF with a deflection of less than 1/180 span. 8. All design- and construction must comply with the latest editions of the Energy Conservation Construction Code, the Residential Code of New York State, The National Electric Code and with any applicable local codes and/or regulations. Q�OFESSIOry9 WilliamE. Montgomery r. PE Sao Dated: January 8, 2004 Work No.04-01=C � , 931419 `THE STAt��� General Specifications for Magee Addition Exterior Features: o Premium Vinyl Siding, White Vinyl Soffits and Aluminum Fascia. o Rubber Roof on Existing Porch and Addition o Andersen Windows o White Vinyl Window Grids for All Andersen Windows. o Velux Roof Ventilating Windows o Exterior Electrical Outlet o Light Fixture at Atrium Door Location Construction And Energy Features: 0 8" Poured Concrete Foundation Walls 0 3/" Oriented Strand Board Subfloor, Nailed and Glued 0 2x6 Exterior Walls with 7/16" Oriented Strand Board Sheathing o Exterior House Wrap on All Heated Exterior Walls o R-21 Fiberglass Batts Wall Insulation o R-30 Fiberglass Batts Ceiling and Floor Insulation o Andersen Exterior Doors Custom Interiors: o Walls and Ceilings Finished with Two Coats of Latex Paint o Interior Trim and Doors Finished with High Gloss Paint Floor Coverings: o Hardwood Floor to Match Existing i Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code RES checkSoftware Version 3.5 Release 1 c Data filename:C:\Program Files\Check\REScheck\magee.rck TITLE:Magee Addition COUNTY:Warren STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached I or 2 Family HEATING TYPE:Non-Electric DATE: 01/09/04 DATE OF PLANS: 12/28/03 PROJECT INFORMATION: C1��E�SgUE� Expand existing Kitchen by 14'x16' ge"k\D'G COMPANY INFORMATION: Da2B Builders,LLC COMPLIANCE:Passes Maxnnum UA=75 Your Home UA=74 1.3%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 224 30.0 0.0 7 Skylight 1: Metal Frame with Thermal Break:Double Pane with Low-E 14 0.330 5 Wall 1:Wood Frame, 16" o.c. 352 21.0 0.0 14 Window 1:Wood Frame:Double Pane with Low-E 48 0.280 13 Door 1: Glass 33 0.280 9 Door 2:Glass 21 0.280 6 Basement Wall 1: Insulated Concrete Forms 227 18.0 13 Wall height: 5.5' Depth below grade:2.0' Insulation depth: 5.5' Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 224 30.0 0.0 7 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. ;' Builder/Designer /' �i r/ Date ! l� REScheck Inspection Checklist — O 0 y New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lc DATE:01/09/04 TITLE:Magee Addition Bldg. I ® 9 20p4 Dept. I J A� Use �O�t�00`NG AND CODE Ceilings: dU�l [ ] I 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: I Above-Grade Walls: [ ] I 1. Wall 1: Wood Frame, 16" o.c.,R-21.0 cavity insulation Comments: I Basement Walls: [ ] I 1. Basement Wall 1: Insulated Concrete Forms,5.5'ht/2.0'bg/5.5'insul, R-18.0 assembly R-value Documentation must be submitted verifying the overall assembly R-value. The R-value must be developed in accordance with accepted engineering practice. Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. I Windows: [ ] I 1. Window 1: Wood Frame:Double Pane with Low-E,U-factor:0.280 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: I Skylights: [ ] I 1. Skylight 1:Metal Frame with Thermal Break:Double Pane with Low-E,U-factor:0.330 For skylights without labeled U-factors, describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: I Doors: [ ] I 1. Door 1: Glass,U-factor: 0.280 Comments: [ ] I 2. Door 2: Glass,U-factor:0.280 Comments: I Floors: [ ] I 1. Floor 1: All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation Comments: I Air Leakage: [ ] I Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3" clearance from insulation. I i r Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [ ] J All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State ,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts 1" and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refi-igerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)