2004-039 ` TOWN OF QUEENSBUIRY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20040039 Date Issued: Thursday, December 29, 2005
This is to certify that work requested-to be done as shown by Permit Number P20040039
has been completed.
Tax Map Number: 523400-295-015-0001-052-000-0000
Location: 27 LYNNFIELD Dr
Owner: JOHN &ELAINE HERSEY
Applicant: JOHN &ELAINE HERSEY
This structure may be occupied as a:
Porch By Order of Town Board
Residential Addition TOWN of EENSBUR
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
-7r TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20040039 Application Number: A20040039
Tax Map No: 523400-295-015-0001-052-000-0000
Permission is hereby granted to: JOHN&ELAINE HERSEY
For property located at: 27 LYNNFIELD Dr
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: JOHN &ELAINE HERSEY
27 LYNNFIELD Dr Porch
QUEENSBURY, NY 12804 Residential Addition $55,000.00
Total Value $55,000.00
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2004-039 John Hersey
AV 46-2003 approved by ZBA 8/27/2003
144 SQ FT OPEN PORCH AND 310 SQ FT RESIDENTIAL
$115.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday, February 06, 2005
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town o Quee )jury;
1d , 2004
SIGNED BY for the Town of Queensbury.
•a;a
Director of Building&Code Enforcement
� rr
Check Residential Plan Review: One&Two Family Dwellings
Y/N/N/A
(2)Full sets of plans
Over 1,500 sq. ft.—Stamped
Design Loads On Plans: 90 Wind Floor Loads 40 psf
70 Ground Snow Load Sleeping Areas and Attics 30 psf
Calculations:
Window Schedule With Glass Size 1
Door Schedule/Main Entrance 36"Door
Emergency Escape Or Bedrooms and Habitable Space
Above/Below grade,5.7 sq.ft.
Grade,5.0 sq.ft.
24"(h)x 20"(w)min.
44"Max.Height above floor
Residential Check Paperwork Compliance and Inspectors Checklist: OK
Dampproofing/Waterproofing Materials On Plans
Foundation Drainage On Plans,if required
g
6"Drop in 10'Exterior Grade
Framing Cross 'on or Each oof Line,Vertical Fire Stopping Every 10'Where
Required r ,z ` 00,e
Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls
Platforms At Exterior Doors
Stairway Headroom 6' 8'All Stairs 36"Width
Stair Run and Rise ,
kV 2 Winder Run and Rise
Spiral Not Allowed From 2n Story
i/ Smoke Detectors Battery Backup and Proper Location
Bathroom Fixtures Proper Clearance
Hall Width,36"min.
Handrails More Than One Riser On Open Sides
Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht.
Safety Glazing Notes For Required Areas
Garage Fire Separation
Garage Floor Sloped
Attic Access
Roof over 30"—22"x 30"/Crawl Spaces 18"is 24"access
Carbon Monoxide Detector Lowest Sleeping Level
Soil Test Results,if required
�. Septic To Well Or Water Line Separation
�%l All Paperwork Signed
Building Permit Application
Jam= Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury,NY
(Sl$)761-$256
A permit must be obtained before beginning constru o.. ,�
No inspection willbe made until applicant has received a e $ u�
valid building permit. All applicants spaces on this FEa e ,F aid
application must bo completed and must appear on the ed By;
application form. T WN OF Q
BUIL ING ND COD
Applicant:sod f� 4'
Address: a� )-x_ er Address:
Phone#(—) 3
Property Location: Lot Number:_/ House Number i. A
Subdivision Name: Tax Map mm er: 77 %�%�S� los
a New Building: residence /commercial 'Estimated Market Value of Construction:$
�Pc Addition: C—re—Ram—cat>00mraeroill If an Addition,what will use of new addition be?
C Alteration: rest once/ commercial
fl o change to exterior size: residence/com'1
Other work(describe �r`--
c Check QCCIIpAncyinformatlgD lot Floor 2° Floor Other floor Total
Below sq.ft. sq.ft. sq.ft. Square Feet
o Single finiily dwelling
o Two fi=fly dwelling
a Townhouse I ` �!` L4-13
o Multifamily dwelling
#of units,-,-„_ l`� I '.1s•
+' ../ ='� ` ^> t�
1
o Office f� N , (� ;� �'. ; �, .7`� - c`
c
o Mercantile 1 �'
0 u£aatutln �' .
0 1 car detached prage /
0 2 oar detached garage i
0 3 car detached, ge
0 1 oar attached garage
0 2 oar attached garage
0 3 car.attached garage
e Storage building-
commercial W (POT
o Storage building
residential
other `� 310 3l0
What is the proposed height of the structure -_,feet � inches
Will any second-hand or ungraded lumber be used? If so,for what?
Type of Heating System: electric/ oil / gas I wood /forced hot air 1 baseboard/other:
Number of Fi ey to be installed Number of Woodsiagl to be installed
List below the persons)responsible for supervision of work as regards to building codes:
Name ddress Phone Numb or _
Builder C v� u. r I o T�er��.� u�G �rfs _ P/3Q_
Plumber
Mason
Electrician
Declaration: please sign,below after you have carefully read the statement:
To the best of my knowledge the statements contained in this application,together with the plans and specifications
submitted,at a true and complete statement of all proposed work to be done on the described premises and that all
provisions of the Building Code,the Zoning Ordinanoe and all other laws pertaining to the proposed work shall be complied
with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Uwe shall
submit,prior to a Certificate of occupancy or Certificate,of Compliance being issued,as requested by the Zoning,
Administrator or Director of Building and Codes,an Asfiuffe Survey by a licensed surveyor;drawn to scale,showing actual
location of all new construction.
Signature: owner,owner's agent,architect,contractor
Porch, Deck, Dock, or Boathouse Permit Application
Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury,NY
(518)761-8256
A permit must be obtained before beginning COMKQ�I rmifkle No. -
inspection will be made until applicant has received a valid a Paid
building permit. All applicants'spaces on this applicafi"4t Reviewed By
107
completed and must appear on the application form
1W
TOWN OF Q NSB
UILDIN CO
A E
JJ
Applicant: Di�� A ..f � a.�,:e Cam, r
Address: Address:
Phone#(_) 7`t5- lrA:7 Phone#(_) -
Email Address: —" Email Address:,
cei.P: -) ti4 - 4
Person Responsible for Supervision of Work as Regards to Building Codes:
Name�v�P � — Address: �'��C5 Phone
Property Location: Lot Number: / House Number
Subdivision Name: Tax Map Number:
Estimated Market Value of Construction: $ - I I
E?OPorch &P&P, `oo✓r-j, -�/ j
❑ Deck
❑ Dock -01
❑ Boathouse ^
i�-
❑ Other work(describe
Size of structure to be built square feet
Submit along with this application:
1. Two plot plans drawn to scale,preferably using a survey map. Indicate proposed
structure showing setback dimensions from all property lines. Show location of
water supply and location and configuration of septic disposal area.
2. Two sets of structural drawings. Indicate size of posts or studs,floor joists,
decking or flooring material to be used. Show how the porch or deck will be
fastened to the building. If a roof will be constructed,indicate the size of posts or
studs,roof rafter spacing and span. Indicate type of roof: sloped,flat, shed, or
other. Indicate the type of material being used for the roof.
Declaration: please sign below after you have carefully read the statement:
To the best of my knowledge the statements contained in this application,together with the plans and
specifications submitted,are a true and complete statement of all proposed work to be done on the
described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws
pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is
authorized by the owner
Applicant's signature: Date: :p '3'00
*—
L:\SueHemingway\Building.Permit.FORMS\Porch.Porch.Permit.doe 8/13/02 revised per DH
4'
. Queensbury Building & Code Enforcement - Residential Final Inspection
Office No.(518)761-8256 Arrive: am/pm Depart: ; am/pm
Date Inspection request received: �� Inspector's Initials:
NAME: v` `-E-�`�/��V�►-►. ,�'- -(`�1 7 PERMIT
LOCATION: 2�_ I Fib L\) bl DATE:
TYPE OF STRUCTURE: ct ,VA
Comments
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet f-
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(hei ht)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s . ft,150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp, 110
Enclosed Stairs Sheetrock Underside minimum%"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fire roofin /3g /<hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass gnclo ure
Final Electrical G
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Pla}n-Certification,if required
Okay to is96e C/C o C/O[Temporary/Permanent]
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc
AL Queensbury Building & Code Enforcement - Residential Final Inspection
,
e ?—f1
Office No.(518)761-8256 Arrive: am/p D art: --�m
Date Inspection request received: Inspector's Initials:
NAME: _ PERMIT#:
odd C�-( 'n
LOCATION: _ DATE:
TYPE OF STRUCTURE:
Comments
Y N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6"
Roof Complete/Exterior Finish Complete
Guard 30 in.or more a),stairs,decks,patios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in. or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in."'
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum '/"
Gypsum
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
.Gas Furnace shut-off within 30 ft.or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: / Battery backup:
Carbon Monoxide Detector
Bathroom Fans, if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grRde
Basement stairs closed rise>4 inches
Garage Floor Pitched _
Garage fireproofing/3/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Attic access 30 in.x 22 in,x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents
Building No./Address visible from road
Final Electrical
Site Plan /Variance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Flood Plain Certification, if required
Okay to issue C/C or C/O Temporary/Permanent
L:\PamW\Buildiniz&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04
0 -10,`3�
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT #: '
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2,R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 % inch min.Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/chan a of direction
Water Supply Piping
C per Commercial
0O _er,CPVC,Pex One and Two-Family
iis'` anon=/Residential'Check/ Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
uct work sealed properly/No duct tape
COMMENTS:
c
L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building& Code Enforcement Arrive: am/ Depart: am/p ��
742 BayRoad ueensbu NY 12804 Inspector's Initials �f/ - v
, Q ry� p ����
NAME: PERMIT #: Oq ' O
LOCATION: INSPECT ON: (4
TYPE OF STRUCTURE:
YY N N/A
PVC: R-1,R-2,R-3,R4 Drain/Vents
Cast Ir , Copper Drain/Vent/ Comm.
PI ing Vent/Vents in Place
'kou h Plumbic [Nail Plates
-1 1/2 inch min.Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/chan a of direction
Water Supply Piping
Cooper Commercial
Cooper,CPVC,Pex One and Two-Family
-WWation/Residential Check/Commercial Check
Pro er Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
ct work seal! ro 1 /No duct tape
COMMENTS:
L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003
Framing /Firestopping Inspection Report s
Office - 2 Date Inspection request received: -
No. (518) 761 8 56 p q
Queensbury Building&Code Enforcement Arrive: a p Depart: am/pm
742 Bay Road,Queensbury,NY 12804 Inspector's Initial
NAME: PERMIT#: `/ 03
9
LOCATION: \ INSPECT ON: Q 7
TYPE OF STRUCTURE:
Framing
Y N N/A COMMENTS
.
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2(w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft, floor trusses
Anchor Bolts 6 ft. or less on center
ce and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side 11/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LASuelIemingway\Building.Codes.Inspection.FORMSTraming Firestopping Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No. (518)761-8256 Date Inspection request rZ(�'Depart:
:
Queensbury Building&Code Enforcement Arrive: --L a L L am/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:
NAME: NAE PERMIT#: -ZUo
LOCATION: INSPECT ON: .7_ S t-
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
r
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\SueHemingwaylBui]ding.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection e'v
Queensbury Building&Code Enforcement Arrive: I a Depart:
742 Bay Rd., Queensbury,NY 12804 Inspector's Im IN s:
NAME: H C 1��1L� c Y�V.1 #: 2AG�-1
LOCATION: L SPECT ON: �A 0
TYPE OF STRUCTURE: (Zela , RW
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
LASueHemingway\Building.Codes.Inspection.FORMSToundation Inspection Report.doc January 28,2003
S �
Permit Number
MECcheck Compliance Report Checked By/Date
New York State Energy Conservation Construction Code
MECcheck Software Version 3.3 Release lc
Data filename:C:\Program Files\Check\MECcheck\Hersey.cck
TITLE:House Addition
COUNTY: Warren
STATE:New York
HDD:7635
CONSTRUCTION'TYPE:Detached 1 or 2 Family
HEATING TYPE:Non-Electric
DATE: 04/02/04
DATE OF PLANS: 10 sept.2002.rev.3.26.0 LI%
PROJECT INFORMATION:
Mr.&Mrs.John Hersey,
27,Lynnfield drive,
Queensbury,N.Y. 12804
COMPANY INFORMATION:
Roger King-Hall,architect,
17,Kings road,
Gansevoort,N.Y.12831.
COMPLIANCE:Passes
Maximum UA=82
Your Home=72
12.2%Better Than Code
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R Value R Value U Factor UA
Ceiling 1:Flat Ceiling or Scissor Truss 345 38.0 0.0 10
Wall 1:Wood Frame, 16"o.c. 333 21.0 0.0 14
Window 1:Wood Frame,Double Pane with Low-E 19 0.260 5
Window 3:Wood Frame,Double Pane with Low-E 19 0.260 5
Window 4: Wood Frame,Double Pane with Low-E 5 0.260 1
Window 5:Wood Frame,Double Pane with Low E 5 0.260 1
Window 6:Wood Frame,Double Pane with Low-E 12 0.260 3
Window 7:Wood Frame,Double Pane with Low-E 8 0.260 2
Door 2: Solid 21 0.250 5
Floor 1:All-Wood Joist/Truss,Over Unconditioned Space 345 21.0 0.0 15
Crawl 1:
Solid Concrete or Masonry,4.0'ht/3.5'bg/3.7'insul 212 21.0 -0.0 11
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the
building plans,specifications,and other calculations submitted with this permit application. The proposed systems
have been designed to meet the New York State Energy Conservation Construction Code requirements. When a
Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her
knowledge,belief,and olessional jud enrpgqiplans spec' i tions are in compliance with this Code.
Builder/Designer Z ( �- Date
P .. .KjjVQ y��
it 9�
r
�k
%749•N
F0F NE`��
MECcheck Inspection Checklist
New York State Energy Conservation Construction Code
MECcheck Software Version 3.3 Release lc
DATE:04/02/04
TITLE:House Addition
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R 38.0 cavity insulation
Comments:
Above-Grade Walls:
[ ] 1. Wall 1:Wood Frame, 16"o.c.,R 21.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1:Wood Frame,Double Pane with Low-E,U-factor:0.260
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
[ ] 2. Window 3:Wood Frame,Double Pane with Low-E,U-factor: 0.260
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
[ ] 3. Window 4:Wood Frame,Double Pane with Low-E,U-factor:0.260
For windows without labeled U factors,describe features:
#Panes Frame Type Thermal Break? [ ]Yes[ ]No
Comments:
[ ] 4. Window 5:Wood Frame,Double Pane with Low-E,U-factor:0.260
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
[ ] 1 5. Window 6:Wood Frame,Double Pane with Low-E,U-factor:0.260
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
[ . ] 6. Window 7:Wood Frame,Double Pane with Low-E,U-factor:0.260
For windows without labeled U factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
Doors:.
[ ] 1. Door 2: Solid,U-factor:0.250
Comments:
Floors:
[ ] 1. Floor 1:All-Wood Joist/Truss,Over Unconditioned Space,R 21.0 cavity insulation
Comments:
Crawl Space Walls:
[ ] 1. Crawl 1: Solid Concrete or Masonry,4.0'ht/3.5'bg/3.7'insul,
R-21.0 cavity insulation
Comments:
Applies to walls of unventilated crawl spaces.
Air Leakage:
[ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air
leakage must be scaled.
[ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly
with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a
3"clearance from insulation.
Vapor Retarder:
[ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications.
Duct Insulation:
[ ] Supply ducts in unconditioned attics or outside the building must be insulated to R 11.
[ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6.
[ ] Supply ducts in unconditioned spaces must be insulated to R 11.
[ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2.
Insulation is not required on return ducts in basements.
Duct Construction:
[ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
(adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in.w.g.(500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
Electric Systems:
[ ] Separate electric meters are required for each dwelling unit.
Fireplaces:
[ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
provisions of the Building Code of New York State,the Residential Code of New York State or
the New York City Building Code,as applicable.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
i
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55°F must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pine Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Up to 1„ Up to 1.25" _ 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD(Building Department Use Only)
QOGEQ A.Q . KING-HALL
AQCHITECT
v pj��- @um2J - D 11\)Css m-ru 10 ge p*v 200E FOR
q E A DVC[w;O � a, � � ��� 4 &r
C",OG& CetUO' G WFULaMD'O -To
r
Q Y
0TO6MI7
N
h.
17 Kin88 Qoad, Gamevoort. New York 12831
QOGEQ A.Q. KING-IIALL
AQCHITECT
2
A Pe� 2 c,-
-7 8Ay P.ePip 27," LyOa� D¢w&
Q�a�sg,�, 0V,FAX 74�'� 44:N7 - s P,aMEs
MF--c,U+904- GO"(7G%*K �
e4,vn R-D��utt�2�va.Tga k0oro&2��s99rcao 68cL)56
caXS-rLo,)s
17 Kings Road, Gansevoort, New York 12831
� J
Q0CEQ A. Q . KING-HALL
AQCHITECT
ADDENDUM #I to drawings dated 10 sept.2002,for house addition for
Mr. & Mrs. John Hersey, 27 Lynnfield,
Queensbury,N.Y.12 8 04.
1.Design loads: First floor-40 p.s.f. Ground snow load 70 p.s.f. Wind POECEIVED6E
2.See window schedule attached for egress compliance. MAR 2004
Master bedroom area 258 s.f. Req. Light @ 8%=20.6 s.f. Actual 44.5 s.f.
Req. Vent @ 4%= 10.3 s.f. Actual 21.01ONN OF QUEENSBURY
3.Dampproofing to be Thoroseal. �g�BUR-DING AND CODE
4.Ice and snow shield at eaves to be 24" beyond inside wall surface.
5.Slope finished grade 6" in first 10'.
6. Install safety glazing as required by N.Y. state building code.
7. Install 18" x 24" attic access in closet ceiling.
8. Install carbon monoxide and smoke detectors.
9.Porch roof cross section.
2ic6 CaXr.PLATE
2xeA7 W O.G �Gflx
PLYWoDD H GLiPS, i5 FELTPAPne
x4 Ga4�o•G Li3 FiE=2G4-ASS 6P[aSLES_
2x6�Locyu 2'C FLATE
<2x4 <�@ ��O.G.yz.c2ax PLC/WCoD .BEAfl EcteO F;M?iSN,
. EX�sTiti►G gUlL.att`lC
2-2 x µa<LeO- 6E--LFtEe P
QOWS f,12 o,c wrTH l lly r ,M
TO MATCK E.Xa STI i:(5.
�4.'=1-6 SEE stay EL,EvA rii)q A. .
`BRED AR�tii
�5 N.R.KING. Tim
r
01674CY
F NEB
17 Kings Load, GanbCvoort. NCW York 12831
f
x ,
�t
w
ui
a 108 SlTk ADTS1t lVY• i ! I --�_.__.._ OATF.-3f22I2()O4 _ _.. � m IT
vn4m. 00kinNels : 1CONTRACTOR: bavidFWler- APPDCA'j'JON10 fILEY ± o
a.
f WWD MlG. I CATALOG VIrRMW ltw� Roupy 'SQ.Err. SO.M From am CIA
QTY_ w NAME CONSTRUCROl1 Nt"JEA GLAZING Type. ow� Opa-4rta lit VI`MLE VENT I]A OPENMG OFENM NOT" rrt
j 11YlM LICUT O!•tdlLA WVfW HEIGHT o
m 1 Ah MAItVtN Aium Clad Wood C(MHT 3012 LuE Amp-IG DH tM)m 36.315 20-1875 2.37 HfA WA WA NIA Slalio
1 Ah MARVIN Alum Clad Wood CUDII7'3012 LaE 16 DE11mjtn 36.315 70.1375 2.5Y Na HIA WA NIA Statism
10 �Q 1 A MAR AbM Clad Woad CUDH 30M LOE n-16 DH 36.375 78.973 13.23 S." . SBa 3x.(low 26.3400 Go S k DID s in
cn Qj 1 A MARV A►w Clad Wo CUIW 3034 LaE -W 11H '36.375 78.975 13.23 S-93 SLSS 132.000D 26-UW SSLIC DH m
y•U• 1 B MAItVIN Alma Clad Wood CUDli 12U LGH&MIG DH• U373 60.675 30.72 4.81 Al 34.MM n
Co o DH t
I B ?d&RVIW Alum Clad Wood CUDH3226 WE 16 DH 39.37S 6AB75 10.72 -4.81 421 36.0900 ItDH
� c 1 H MARVM Atmn Clad Wot�d CEJDH 322b Lat?As IO DH 38 375 6Q_9<73 1@.7l 4.81 4A1 34.a8Qp 5 k DU
g�1ZOt5h I C 14IAHVIN t� Wood I CtIDH 2426 LoE iG D 30.375 1<73 7.44 3.69 3159 -1 26.00D 2034W SM DI{
-=� --- 1 I D IMAtI1N AlumCladwood CAWW41124 I Lay IG AWNIkG 49T •23.625 4.97 570 MIA NIA NIA AWNING
f ATp P.ODq 1 1 D MAAVIN Aka Clad Wood CAWN4424 LuE ArpwiG AW111N1` 44 1 23.625 4.97 31 /A NIA
Ft7l
?(tal Light!81.6645
_ Total Vent: 41.2800 '
O
rn Please rlotc: that only windows in bold type meet tht 5.7 SF(at 2ND Pir)regress►eepirsment
a
meet the 5.0 SF( 1st Flr.)egm ngairnmsnt i
a •
a
in
ca
o >y
ro
0
cn N of
N Q
L F rtpafca by fldwl Faa:
' ro rl[a?:u(�harbrook.com
7=