Loading...
2004-101 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20040101 Date Issued: Friday, June 18, 2004 This is to certify that work requested to be done as shown by Permit Number P20040101 has been completed. Tax Map Number: 523400-309-006-0001-014-000-0000 Location: 50 VETERANS Rd Owner: LARRY CLUTE Applicant: LARRY CLUTE � This structure may be occupied as a: j By Order of Town Board Garage - 1 Car Attached TOWN OF QUEENSBURY Single,Family Dwelling j .� /� A— Director of Building&Code Enforcement I - TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040101 Application Number: A20040101 Tax Map No: 523400-309-006-0001-014-000-0000 Permission is hereby granted to: TARRY CT,T TTF, For property located at: ALTA Ave in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: LARRY CLUTE 13 DAWN Rd Garage- 1 Car Attached Single Family Dwelling $85,000.00 QUEENSBURY,NY 12804-0000 Total Value $85,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency CLTTT'E ENTERPRISES INC. 13 DAWN Rd OITEENSBITRY_ NY 12804 Plans&Specifications 2004-101 Tax Id No. 309.6-1-14 and 13 936 SQ FT SINGLE FAMILY DWELLING (2 lots combined which goes from Alta Ave. thru to Veterans Road). House appears to front on Veterans Road. $142.32 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, March 30, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To o eensb s rch 30, 2004 SIGNED BY . for the Town of Queensbury. r .y Director of Building&Code Enforcement jDuuumg Term -c xppucanon Town of Queensbury—Dept of Community,Development,742 Bay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No. �`1 J No inspection will be made until applicant has received a Fee Paid $ valid building permit. All applicants'spaces on this Rec.Fee Paid $ application must be completed and must appear on the Reviewed By: application form. Applicant: Owner. Address: Address: 21� Lid Phone#(_) - —T Phone# 7>77 Property Location: Lot Number. / House Number—/ Subdivision Name: Tax Map Number: 7,�r'1 . iCl tam •-tI - New Building: residence /commercial 'Estimated Market Value of Construction:$ aT6 o Addition: residence/ commercial If an Addition,what will use of new addition be? u Alteration: residence/ commercial t] No change to exterior size: residence/com'l o Other work(describe ) Check OCCIIpanCyTnfonntion 1' Floor 2 Floor Other floor Total Below sq ft. sq.ft. sq.ft,_ Square Feet Single fauu'ly dwelling mot , 9 3 o Two#pA!y dwelling v Townhouse o Multifamily dwelling #of units a Office ci Mercantile o Manufacturin 13. 1 car detached garage v 2 car detached garage 0 -3 car detached garage 1 car attached garage :24-0 v 2 car attached garage 0 3 car attached garage v Storage building- commercial o Storage building- residential 13 Other What is the proposed height of the structure = feet inches Will any second-hand or ungraded lumber be used? If so,for what? 5I`:C V'e Type of Heating System: electric/ o' gas/ od forced hot air_�Saseboard/other. Number of ire laces to be installed ("L Number of Woodstoves to be installed_ List below the person(s)responsible for supervision of work as regards to budding codes: Name Address PhoneNumber Builder Plumber Mason Electrician DecIarationi please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a.trot and complete statement of all proposed work to be done on the described premises and that all provisions of the Btril ,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether sp or noted,and that such work is authorized by the owner. Further,4 is understood that Uwe shall submit;prior Certificate of O ancy or C4ficate of Compliance being issued,as requested by the Zoning Adn ' 7&Y or Director of ding and Cod As Butlt Survev by a licensed surveyor,drawn to scale,showing actual locatio new S' owner,owner's agent,architect;contractor Application for Permit—Septic Disposal System Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 1. OWNER INFORMATION: __.�...._ +� I Office Use Location of installation: File Permit No'-)-00`7��/ � l Tax Map No. f Fee Paid Owner's Name: �.4^-z�l•--� �-- � )�,P. ?____ _... . __ __. - - __._._...._ Address: 2. INSTALLER'S NAMEJ�e �. r-.G � '� r PHONE NO. Z`LZ - �Z? 3. RESIDENCE INFORMATION: (circle year of dwelling,indicate#bedroom(s)and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) Zow) Year of House: No of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gal/bdrm = 1980-1991 x 130 gaYbdrm = 1991-present IV7- x 110 gal/bdrm = -"Z 2� Garbage Grinder Installed yes_ J ni < Spa or Hot Tub Installed yes_ / no 4: PARCEL INFORMATION: (circle applicable information&indicate measurements) ToDopranhv S tare Ground Water Bedrock or Impervious Material Do Water Su 1 lat sand at what depth at what depth munici Rolling oam" _____feet -feet well Steep slope clay if well;water supply slope other from any septic system depth: absorption is ft. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: minute per inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: (.W a gallon(min.size 1,000 gal.) Tile Field: each trench . Total System Length: ( 50 ft. Seepage Pit(s): number of size of each: ft. by ft. Size gf Stone to be used: # / depth or thickness feet Bed System Size: x Alternative System: length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons /TOTAL" Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136 29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have r the regulation with re sp t to this application and agree to abide by these and all re q ' ements of the Que sb Sanitary Sewage Disposal Ordinance. Signa ure of responsible person Date ENERGY CODE COMPLIANCE APPLICATION Ll_ TOWN OF QUEENSBURY, WARREN COUNTY �l 9000 HEATING DEGREE DAYS / Compliance Methods:Part 5 -Acceptable Practice Method—1&2 Family Dwellings(only) Part 6*-Thermal Rating—Component trade Offs 1&2 Family Dwelling; Multi=:Fau ly Dwellings(3 Stories or less) Part 4*-Design by Component Performance,Commercial Buildings-Hi Rise Residential *Requires submission of worksheets APPLICANT'S NAME: c� PROPERTY LOCATION: PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE- I. Gross Floor Area-- .3 square feet 2. Type of heat- Electric . Oil_ �� Gas Other 3. Is building mechanically cooled? yesNo 4. Percentage of area of windows and doors Over 17% >-15',' Under 17% ` 5. R VALUES FOR INSULATION GIVEN BELOW MUST CORRESPOND TOR VALUES AS SHOWN ON PLANS SUBMITTED: a: Roof R 77,z) b. Exterior walls R t1 C. Glazed areas R Z. d. Exterior doors R (1Y.5 e. Floors over unheated spaces R — f. Edge of slab on grade(heated building) R g. Basement/cellar walls(above grade) Rom_ h. Basementicellar walls(below grade) R t-1 i. Heating/cooling-ducts-piping in unheated space R k_j�5 6. Service(domestic)hot water heating device Conforms to minimum efficiency per code Yes No TE CONTR L MAXIMUM SETTING 140—WILL NOT BE EXEEDED pp ' "gtmat Date Phone Number �3 / --Z Z S _7XI 77 INSPECTOR'S REMARKS: i 4 Job g to ,Adress: ' Date: Owner: LI-A-s'7 �4 L�j\ Application No. File No. r--7 WINDOW SCHEDULE .;'.'' .;,....t. ., ., t �i, .•o'. . `. .,. �,Opej�tn$5pGo7�ic��gn¢....,� �., ,,,, .. .. .,a>.,. ...... . . . Window Window Mfg, Window Unit or Rough 'i Rough SQ FT SQ;FT SQ FT :Clear. : Clear „; Special Hardware or Number or Name Model Stock Opening �Openuig r GlassNi`sib Uettt EgresslGlear Qpenuig t2penitrg Height instructions Letter on Or Type Number Widih, 'i Hetg t �l;' Opc�ntng Widxh In ' In Itc hes Plan Call Size n �•� r I hes ` 1/c� 57 -THIS LINE HAS EXAMPLES OF SAMPLE ENTRIES A Andersen Narcohpe 3062• 3':21/3" 6'5'/" 15,30 8,3.6 ' 601 34 4t;5/35" Temliered t Double i 11M6 Glazing a .\SueHemingwny\9uilding.Permit.PORMS\Window Schedule.doc t fib Site Address: .� QS Date: 71, lk� dcs� Owner; ' ���.-.�� ,r �.__�J�. Application No. File No. Building Permit — Calculation Sheet Natural Light, Ventilation & Emergency Egress Requirements Habitable Area of Req. Light Actual ' - Req,,Vent Actual ' Sq.Ft. Remarks Room Roo F ; Room Li ht m ; a 8%of g 4%of Room Vent R Opening for in Al.,i, ,;. mzw Area Square Fy;4i; Area Square ;; :;; Egress Square #` g q s Footage y Footage Feet Prt �•}, U:mac ,•'�-!?; `; W ..2" �• L:\SueHeminpvay\Building.Permit.FORMSW at,Light.Ventil.Caleulation,Sheet.doe Permit Number REScheck Compliance Certificate Checked By/1)ate New York State Energy Conservation Construction Code REScheckSoflware Version 3.5 Release 1d Data filename:A:\\26 x 36 Ran Veterans Road.rck PROJECT TITLE:26 x 36 Ranch COUNTY:Warren STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING.TYPE:Non-Electric DATE:03/16/04 DATE OF PLANS: 03/16/2004 PROJECT DESCRIPTION: Veterans Road Queensbury,NY 12804 DESIGNER/CONTRACTOR: Clute Enterprises.Inc. 13 Dawn Road Queensbury, NY 12804 COMPLIANCE:Passes Maximum UA=339 Your Home UA=237 30.1%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 936 30.0 . 0.0 33 Wall 1:Wood Frame, 16"o.c. 1972 19.0 0.0 112 Window 1:Vinyl Frame:Double Pane 67 0.490 33 Door 1: Solid 21 0.230 5 Door 2:Glass 21 0.490 10 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 936 19.0 0.0 44 Furnace 1:Forced Hot Air,90 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are a V g t at to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance 'th' Code. Builder/Designer Date I f 6 �(� REScck l-nspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release Id DATE: 03/16/04 PROJECT TITLE:26 x 36 Ranch Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1:Wood Frame, 16" o.c.,R-19.0'cavity insulation Comments: Windows: [ ] 1. Window 1:Vinyl Frame:Double Pane,U-factor:0.490 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: Doors: [ ] 1. Door 1: Solid,U-factor: 0.230 Comments: [ ] 2. Door 2: Glass,iI-factor:0.490 Comments: Floors: [ ] 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-19.0 cavity insulation Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,90 AFUE or higher Make and Model Number Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation:, [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R 11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State ,the Residential Code of New York State or the New York City Building Code ,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1:` Minimum Insulation Thickness for Circulating Hot Water Pipes. r Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5. 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature - 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) .L.. ...... . i-"_. L i...... ! I Y. or ixi + e ' s4P CV I I I I _. .i , I ' _ [ . . I II ..._........i.. �\ I hr� � I �. �+ I rJ , L. .. .I n l jh.4 ib 5 uQt Tsai C111 E?r papa"i ?. S)?L ,QCfS�!?�+'rl� Ifii•;aIO, i,, C QQ ..I I, tr , I I I t I ' I J' 1 I ITT RE I ATE i I I I Si I. I i i i i I i i I I I I i I I + I I L .-. i ..._ .... I i I. .. .. _. i .. .. � . : ; 1 i I I I i i i I I I I I I i i I I I...... i.... i. .... . L.. I, ... �.. . ! I I _ � I i 1. I I I i Im7an—I —t! 7 y I ...I ..I .. 01 .. . . . . i I I I Id 1 ? 1 I I I I ! 1 I I �, '� r`.�" I ' ..�„= I ----i'--,.,"-�'�----� ,�. ! .. ..�-•,. I.. _� � I i .. ... i i 1 . . .. .IIi J-4 1 . I I.. . . . j L L .ff..... I'I . -.... ... Ii.. .. ! . 1 .• , ni. ! I I T. ' i ---- ._.. it I I : I I 1 I I I I i , _.I ._ I ... I . _i. .._.I . ..L. . i.. !_... I. . I i I I i I I I I I I f i I I j. �. of I i I i. i r I I _ ---i j I _.. i... _. , I � ..... .. ....... . .. III ..._.ii.. .. lI ...'I . I1.1. . . I I I . ,... ii...... .....,..I .......... .... .Ii . ... r ; I , I ...-... , _ _.I I. I 1 ' I,I IIII,i II l ii .I; �n i -, =.�..�.- �,- _•I--'� aIs. p-::_a-iIw... .I .� -- I .i I. I I _ I i . I . I . K_- I . _ _ _ _ ++4 I!II +1 _ •I .. I. _. -,Queensbury Building & Code Enforcement - Residential Final n�spection Office No.(518)761-8256 Arrive: am/p D part. ,LS am/pm Date Inspection request received: 1 7 U t/ Inspector's Initials: NAME: 414LIkl —�'1 �� PERMIT#: LOCATION: DATE: _ TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Com lete Guard 30 in. or more @ stairs, decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in,to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at enhance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Batter backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss, draft stopping finished basement 1,000 sf Emergency egress below rade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properlyl Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24Y acg6ss, 1 s . ft.-150 s .ft. vents Building No./Addresjv'&g,forn.ro Final Electrical Site Plan /Varianc-efre4hired Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent J L:\PamW\Building&Codes\Insuection Forms\Res.Final Inso. form 2.docLast printed 2/12/04 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection reque t received: Queensbury Building&Code Enforcement Arrive: am/p /' Depart: pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: ( L� NAME: PERMIT#: LOCATION: INSPECT ON:TYPE OF STRUCTU Comments Y N/A ngs Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour <J d U ` �� j J � 5K Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for"wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade:6 inch drop within 10 ft. L:\SueHeniingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 TOWN OF QUEENSBURY BUILDING '& CODE ENFORCEMENT } 742 BAY ROAD QUEENSBURY NY 12804 (518)745-4447 ARRIVE: DEPART: INSP: FINAL INSPECTION REPORT COMMERCIAL ------ MULTIPLE DWELLING (hotel, motel, apt. complex) DATE INSPECTION REQUEST RECEIVED: NAME / LOCATION47 A DATE PERMIT A L r D TYPE OF STRUCTURE FOOTINGS _BACKFILL_ FRAMING_ PLUMBING_ INSULATION N/A YES NO CHIMNEY "B" VENT HEIGHT PLUMBING VENT FIXTURES ROOFING EXTERIOR FINISH HEATING HOT WATER RELIEF VALVES FLOORS FOUNDATION INSULATION INTERIOR STAIRS RAILINGS STOCKROOM ENCLOSURE FIRE DEMISE WALLS PENETRATION FIRE DAMPERS CEILING FIRE STOPPING FIRE DOORS CLOSERS EXIT DOOR HARDWARE EXIT STAIRS/RAILS PLATFORM ELEVATOR HANDICAPPED ACCESS HANDICAPPED BATHS HANDICAPPED PARKING FINAL ELECTRICAL �NALSURVVEY IANCE RE . PLOT PLAN IF RE OK TO ISSUE C/O OR C C Septic Inspection Report - i Office No. (518)761-8256 Date Inspection request received: QueensburyiBuilding&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd, Queensbury,NY 12804 Inspector's Initials: NAME: ' PERMIT NO.: l 1 r LOCATION: INSPECT ON: RECHECK: Comments and/or diagram Soil Type: Sa ay T e of Water unicipal/ ell Water Waterline sea ce ft. Well separation distance ft. Other.wells: ft. -Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping . Si Type Building to tank G Distribution Box % Field/Pit w n Opening Sealed: N/Partial Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y N Location of Syste on Property: Front Rear Left Side Right Side Middle Front dle Rear S stem Use Statu Approved Partial Approved and needs to.be re-inspected,please call the Building&Codes Office Disapproved L:1SueHemingwaylBuilding.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 t s, WA i — — — — ---- an — --- JI Oil j s f 222www s — t � ;,� Rough Plumbing / Insulation In ��- � � Inspection Rep Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: , NAME: Q PERMIT #: LOCATION: o d INSPECT ON: (� TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size WasWg Machine Drain 2 inch min. E "a 'ff-Supply Test ram and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply PipingA�-5 /q Cooper Commercial Cooper, CPVC,Pex One and Two-Family 4Insul'tiori`%Residential Check/ Commercial Check Pro _er Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.hispection.FORMS\Rough Plumbing Insulation Repott.doc November 17,2003 Framing/Firestoppmg Inspection Report Office No. (518)761-8256 Date Inspection request received: J Queensbury Building& Code Enforcement Arrive: am/p epart: 7z Al-aTh/pni ( � 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: �(�-t"L� PERMIT#: C�_X LOCATION: - � INSPECT ON: TYPE OF STRUCTURE: Y z Framing N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I %2(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches fiom wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Irestoppm Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L 4 L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing /Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/nrrLi Depart: m/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: Lu L'' PERMIT#: I LOCATION: INSPECT ON: Z TYPE OF STRUCTURE: Framing 1`V Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate '1 %2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses chor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes,Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing /Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: �-PJZ3 Queensbury Building:&Code Enforcement Arrive: am/p epart: " am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials. NAME: ( c-1►-�—� PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: . Framing Y N l N/A COMMENTS � . Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. . Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center c an sno s I d 24 inches from wall Fire separation 1, 2,3 hour Fire wall.2, 3,4 hour , Firestopping Penetration sealed 16 inch insulation in cavity min. Garage.Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade . L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection reque t received: - U Queensbury Building&Code Enforcement Arrive: am/p Depar am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: i — LOCATION: INSPECT ON: � TYPE OF STRUCT RE: Q- , `5y' -T-7) Comments 30S . &-1--lq�(13 Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Inforcementin Place • Foundation Damp proofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing _6 miLp0 for wet areas under slab -Mac l 11 Approva Plumbing Uri er a PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.Inspecti on.FORIVISToundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: 1 Queensbury Building&Code Enforcement Arrive: am/ , Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:V NAME: PERMIT#: / ^ LOCATION: &A I ALL INSPECT ON: L TYPE OF STRUCTURE: S� Comments Y N/A otings Piers Monolithic Slab Reinforcement in Place The contractor is responsible or providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 1.2 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003