Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2004-118
TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE .OF OCCUPANCY Permit Number: P20040118 Date Issued: Friday, August 05, 2005 This is to certify that work requested to be done as shown by Permit Number P20040118 has been completed. Tax Map Number: 523400-300-016-0001-016-000-0000 Location: 126 FULLER Rd Owner: JAMES M ZAPPONE Applicant: JAMES M ZAPPONE This structure may be occupied as a: Fireplace By Order of Town Board Garage - 3 Cars Attached TOWN OF QUEENSBURY Single Family Dwelling Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. BLDG. PERMIT NO. 2004-1 1 8 APPLICATION FOR A TEMPORARY.CERTIFICATE OF OCCUPANCY A TEMPORARY CERTIFICATE OF OCCUPANCY is hereby requested for the property located at; 126 Fu te,t Road for the following uses: q,;nn.Po �,ri„y„ J January 6, 2005 , �! � �� ✓�- e DATE SIGNATURE OF XP l,6 A'�T TEMPORARY CERTIFICATE OF OCCUPANCY t OF OCCUPANCY is herebyAPPROVED The TEMPORARY CERTIFICATE ( )DISAPPROVED with the following conditions: CyLti6.i cane o(j Occupane.y. to 6e ilzzued.woon compteaon aj: 1) CompZ&ce handiLait 9, guoAd)Lait zgztem a4 pen k4S code 2) com}y ete AinaZ gxading in zpx,i.ng. 3) 1 i-L6taU new attic a.c cezz @ Fi&eAtace end 06 houa e. 4) Fina i Survey. 5) Az b u.,Lt .6 ept.�,c: TEMPORARY CERTIFICATE OF OCCUPANCY FEE: $10. FO $100:00 received on Januastu 6. 2005 - Date of Issuance Director of Bldg. & Code Enforcement THIS TEMPORARY CERTIFICATE,OF OCCUPANCY EXPIRES 180 DAYS VROM THE DATE OFJSSUANCE.' NOTE: This Certificate is NOT VALID unless signed by the Director of Bldg. & Code Enforcement or his designee. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes. (518) 761-8256 BUILDING PERMIT Permit Number: P20040118 Application Number. A20040118 Tax Map No: 523400-300-016-0001-016-000-0000 Permission is hereby granted to: JAWS M Z,APPONF, For property located at: 126 FULLER Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: TAMES M ZAPPONE 28 TRIPHAMMER Rd Fireplace QUEENSBURY, NY 12804 Garage-3 Cars Attached Single Family Dwelling $350,000.00 Total Value $350,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency 1 Plans&Specifications 2004-118 2656 SQ FT SINGLE FAMILY DWELLING WITH 3-CAR ATTACHED GARAGE AND 2 FIREPLACES $405.12 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday,May 21, 2005 (If a longer' eriod is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To of Queensbury; Friday, May 21,2004 r SIGNED BY % .' / for the Town of Queensbury. VV Director of BuildingV Modriforcement Check Residential Plan Review: One &Two Family Dwellings �. Y/N/N/A (2)Full sets of plans ' Over 1,500 sq.ft.—Stam ed Design Loads On Plans: 0'Wind Floor Loads 40 sf , 70 Ground Snow Loa eepmg eas and Attics 30 psf Calculations: Window Schedule With Glass Size } Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade, 5.7 sq.ft. Grade,5.0 sq.f3. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofing/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6"VRequired 10'Exterior Grade ross Sectio 'For Each Roof Lin Vertical Fire Stopping Every 10' Where ow shield 24"Inside Exterior Wall/24"Inside Knee Walls �i�At Exterior Doorseadroom 6' 8'All Stairs 36"Width and Rise fk Winder Run and.Rise r' Spiral Not Allowed From 2n Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas o L Garage Fire Separation Garage Floor Sloped Attic Access _ _ 6�) Roof over 30"— 2"x 30" Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results,if required Septic To Well Or Water Line Separation M— O ' - All Paperwork Signed ,�_ --,� Project Name: 1,,,ps 2a aonn z BP# U Address: - I D LIAR. 2 4 2004 Building Permit Submission SFD TOWj�q OF OUEBNSBUR}( Checklist 2-Famil BUIy��q All items below must be checked either yes,no or not applicable prior to submission of any building permit to the Town of QueensburyBuilding Department. If anyof the below items are lacking,the permit will not be accepted until such time as the application is deemed complete for submission. 1. Building Pernut Application Gompleted ... ... ... ...... 2. Energy Form or(liec"te Energy Gode Gompliance Forms Complete .. g yes ❑no ❑n/a (2 copies) 3. EnergyGode Inspector's Report from CheckMate Program.. :.. ... ... ... .. 0 yes n no ❑n/a (2 copies) 4. Septic application completelyfilled out(if applicable)... ......... ... ... ... ... ❑yes ❑no ❑n/a 5. Solid Fuel Burning or Gas Appliance Form... ... ... ... ...... ... ... ... ... ... ... . Ayes ❑no Dn/a 6. Electrical Inspection Form... ...... [ yes nno 0 7. Two(2) complete sets of structural drawings..... ... ... ... ... ... ... ... ... ... ... .Dyes [Jno Dn/a a) floor plan;b)foundation plan;c) cross sections:d)elevations; e)window and door schedule S. Two(2)site plans showing location of the structure to be built.... ... ...... yes Dno ❑n/a location of well or water lines,location of septic system or sewer line. 9. Setbacks from property lines to new structure......... ...... ............ ... .. Oyes Dno El 10. Setbacks to neighboring wells and septic systems,including onsite well... . ❑yes Dno n/a and septic systems (if applicable) 11. DrivewayPermit... ... ...... ... ... ... ...... ... ... ...... ............... ... ... ... ... d)VS DUO []n/a Date: t Staff Initial: L_\SueHemiagNva}\Buadingl'ernut, OIxMS\Generic Cbeckiist.doc January28,2003 ENERGY CODE COMPLIANCE APPLICATION veo TOWN OF QUEENSBURY, WARREN COUNT* 4. 9000 HEATING DEGREE DAYS op 4Q b�ISQ(lRY ��Compliance Methods:Part S -Acceptable Practice Method— 1&2 Family Dwellings (only) Part 6*-Thermal Rating—Component trade Offs 1&2 Family Dwelling; Multi-Family Dwellings(3 Stories or less) Part 4*-Design by Component Performance, Commercial Buildings=Hi Rise Residential *Requires submission of worksheets APPLICANT'S NAME: PROPERTY LOCATION: �m�s Z»L'Lnn i G Re! Qbt,1 ,v.V awl PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE: 1. Gross Floor Area square feet 2. Type of heat- Electric Oil )` - Gas Other 3. Is building mechanically cooled? A No yes 4. Percentage of area of windows and doors Over 17% Under 17% 5. R-VALUES FOR INSULATION GIVEN BELOW MUST CORRESPONDt TOR VALUES AS , SHOWN ON PLANS SUBMITTED: a: Roof R 3;�,OG b. Exterior walls R C. Glazed areas R a d. Exterior doors R 131 e. Floors over unheated spaces R ,3D, f. Edge of slab on grade(heated building) R g. Basement/cellar walls(above grade) R ice_ h. Basement/cellar walls(below grade) Rom_ i. Heating/cooling-ducts-piping in unheated space R I! 6. Service(domestic)hot water heating device Conforms.to minimum efficiency per code X Yes No TEMPERATURE CONTROL MAXIMUM SETTING 140—WILL NOT BE EXEEDED Applicant's Signature Date Phone Number INSPECTOR'S REMARKS: 1 Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY &5184,761-8205 Application for Fuel Burn O Chimneys applicable to solid fuel & v nted gas .app ces Date pc;�,B�R , 2003 TOWN Qfi Permit No. QUILQp P re IZE/VSBURY Application is hereby made to the Building i Co es issuance of a Building and Use Permit pursuant to-the New York State Fire Prevention and Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to per form required inspections. NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information Fuel Burning Appliance Information (circle appropriate words) Name:_ 01 Stove: wood coal pellet gas Fireplace insert Address: 96 Fireplace, factory-built: wood -gas Fireplace, masonry: oodff oilFurnace: wood Phone:�.�ifl) .3G " If non-masonary applicance, please provide Owner: Manufacturer Name: Address: a 6 rvuz P_ PA .Model Number: LAs�u�r y i/ Chimney Information Phone: �, /�s)�G/-�//9.5 circle appropriate words) IVI ff oc brick stone the steel size: inches Exact Address: z of construction or installation Factory-Built Manufacturer name: Model Number: Note: Listed By: Number: Construction/Installation must conform to NYS Fire Prevention &Building Indicate(circle) chimney material: Code. Consult available Town of Queensbury Handouts regarding required inspections. Double wall / Triple wall / Insulated / Direct venting Chimney Lir e� Cs,sEh�er'�a Depa ttme�t—Tosaru of Qrxe�•�cbuzy, e��or.T� Fire Marshal Code# $Collected $Refunded Receiv from (efiu ded {� � U address: A 173 3389 (190) Public Safity � A 233 2G55 (230) 'nor Sales DATC Nor - o i�nc�u2o— T ww 0"o,& White(Applicant) / Green(Fire Marshal) / Yellow(Bldg.Dept.) / Pink&Goldenrod(Cashier's Dept.) Building Permit Application Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury,NY .� (518)761-8256 TO�Ii BAR g ?0N, A permit must be obtained before beginning construction. Permit File No. No inspection will be'made until applicant has received a Fee Paid $ c0 CRY valid building permit. All applicants' spaces on this Rec.Fee Paid $ D application must be completed and must appear on'the iS Reviewed application form. � Applicant:1 ja.npc �ZA Owner: Address: .1x- Address: e X, tin V.wV 12bp44 Phone#(,igX)jg4,- 76 9 Phone# Property Location: Lot Number:-4L4/ House Number i2 l hvlLEie- i�r� Subdivision Name: Tax Map Number: C:C� New Building: residence /commercial Estimated Market Value of Construction: $ ❑ Addition: residence/ commercial If an Addition,what will use of new addition be? ❑ Alteration: residence/ commercial ❑ No change to exterior size: residence/com'l ❑ Other work(describe ) Check Occupancylnformation 1' Floor 2"d Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet �! Single family dwelling ❑ Two family dwelling Ic ❑ Townhouse ❑ Multifamily dwelling #of units ❑ Office ❑ Mercantile ❑ Manufacturing ❑ 1 car detached garage 2 car detached garage ❑ 3 car detached garage ❑ 1 car attached garage ❑ 2 car attached garage ;i! . 3 car attached garage dG ❑ Storage building- commercial ❑ Storage building- residential a Other - What is the proposed height of the structure. feet inches Will any second-hand or ungraded lumber be used? If so,for what? Ion, Type of Heating System: electric/ oil / gas/wood / orced hot ai,/ baseboard/other: Number of Fireplaces to be installed Z Number of Woodstoves to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number --- -Bondery� - 'l,fs •/R lt��intes2 l� t���;5�"_ c5/ir'-v[> Plumber Mason Electrician Declaration please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the'Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Uwe shall , submit,prior,to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual location of all new construction. Signature: e.-. li4 owner,owner's agent,architect,contractor J • C Application for Permit—Septic Disposal System Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8256 1. OWNER INFORMATION: /l P ......................o... .....�Q: ... ..... ...............,.. T Office Use,,, Location of installation: {2 6v/G E"� OF nt h J File �Q(iRt, Tax Map No. 11.3 1 l - _ Fee Paid Owner's Name: �n✓nes 2I 12Q07 !....................................................................................................................................... Address: `%SS %, y0I�z �t2_. ' V 2 -2.- INSTALLER'S-NAME :' 66MA , G xcat1A"r►9rn, PHONE NO. 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply#.of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gal/bdrm = 1980— 1991 x 130 gal/bdrm = 1991--present _ - -- x 110 gal/bdrm = Garbage Grinder Installed yes, / no U Spa or Hot Tub Installed yes— I no 4.' PARCEL INFORMATION: (circle applicable information&indicate measurements) Topography Soil Nature Ground Water Bedrock or Impervious Material Domestic Water Supply <fAlat== �and� at what depth at what depth municipal CRolla� ng - loam feet feet :_well Steep slope clay if well; water supply _%slope other from any septic-system depth: absorption is ft. other � Perbolation Test:(To be completed by licensed professional engineer or architect) Rate: ---minute per-inch- � 5. PROPOSED SYSTEM: For New Construction: -All individual sewage-disposal systems must be designed by a licensed professional engineer or architect(unless installed in-a Planning Board approved subdivision). Add 250 gallons to the size` ofthe septic tank and leach field for each-Garbage Grinder, Spa or Whirlpool Tub. - -- - Septic Tank:_ j gallon (min. size 1,000"gal) Tile-Field: each trench ft. Total System Length: ft. Seepage Pit(s): number of size of each: ft. by ft. Size of Stone to be used: # / depth or thickness feet Bed System Size: x (y , Alternative System: length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: I Size of each: . gallons I TOTAL Capacity: gallons Note: Alamn-S j'stem-and aSuGC.3+eCl f'l:C?r C`'l-.'J�&1C;1llS�hle inspected by o.-Town approveC� electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. : G -Signature of g sible person - -ate )ueensbury Building & Code Enforcement - jeia al Inspection p Office No.(518)761-8256 Arrive: art: a p Date Inspection request received: Inspector's Initi lNAME: :LOCATION: TYPE OF STRUCTU Comments . --- Y N let/A �I� Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake — 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more a)stairs,decks,patios 1/11 Guard at stairwell at 34 in.or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %Z" Gypsum Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve--shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector _ F Bathroom Fans, if no window 71?� Plumbing fixtures Foundation insulation Floor.truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/<hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 sq. ft.-150 s .ft. vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Ljem orar /Permanent L:\PamW\Buildinjz&Codes\Inspection Fornis\Res. Final Insp. form 2.docLast printed 2/12/04 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: NAME: �,._. LOCATION: t o F 0 V Li D PERMIT#: Final Survey Plot Plan Approved Denied The attached final survey has been received by the / Dept.of / Community Development. Upon review the survey s been: Craig own, Zoning Administrator Notes: P�� ( � Aw V L:\.SueHemingway�Building.Codes.Inspection.FORMS\Final Survey Zoning Administrator.doc Imo / p ► q ► ► �� ► ► qo W � ............ 50. z BERM W y �UL LANDS OF MADELINE WHITE AND LINDA HEAD 911- 189 00 v �t+�� ryf�OO; DIRT ROAD LOT � W Q a ' S7°'�'' R LANDS OF m 10.334 f AC. FRao Q GARAGE , \` S S'9�' PA TRIC/A SORESINO Ste¢; 1150-217 � / 2 STORY / FRAMEDNCE 2 SEPnc TANKS 111 '38" 18" OAK W WFL 'f K WJ v R = 105.00' 2�• oP p a h L = 205.21' FOUND IRON v� 3► PIPE ^ to aq 09y W LANDS OF WILLIAM HERALD 890-169 MAP OF SURVEY e� LEGEND. OF LANDS 01� , -. oF,�I,- 24� • FOUND IRON MARKER J"Ejs M. ZAT PONEG OOAK w,&w O SET IRON ROD W/TH CAP _ p O POINT —E— POWER LINE TOWN OF OUEENSBURY, WARREN COUNTY, NEW YORK —STONE WALL —•—_-FENCE SCALE: 1" = 100' FEBRUARY 5, 2001 ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY UPDATED:FEBRUARY 7, 2005 Fp I-AND SVP MARKED WITH AN ORIGINAL OF THE LAND SURVEYORS UPDATED: AUJ' 1, 2005 TO SHOW TILE FIELD EMBOSSED SEAL OR INKED STAMP SHALL BE CONSIDERED TO BE VALID TRUE COPIES SURVEYED PARCEL l S W. a RWRK& ASWaA TES Lkensed Land Surveyors � Unauthorized Alteration to this map is a TAX MAP PARCEL NO. 4"Abw10264 Sarotwo Rood P.O. Boat 1434 01-06 violation of Section 7209, Subdivision 2 South pens Faft N.Y. 128013 of the New York State Education Law. �2`3— �— � 7 WILLIAM J. ROURKE, LICENSED LAND SURVEYOR NO. 49098 JOB N0. Town of Q ueensbury Fire Marshal 742 Bay Road QZueensbury,NY 12804 761-8205/761-8206 fax 745-4437 Fact�yr Built Gas Fireplace/Stove Inspection Hegort Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructi as specifications contained in the Installation Manual accompanying the appliance.No deviation from the naanufact ed instructions or specifications is allowed. O I �� —Time am J�� aeaa time tat Permit# a, D4 l l v Schedule Inspection p y Name Z A p Pa r,�� Adda�ss 12� 1—� ��-t r� tZ r) -- Rough l�nalli Appliance Manufacturer �C� � r4 t Model# ? 3 3 z Direct dent Factory Built Chimney�Flue Size Double Wall Triple Wall Itasulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chase _ Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet alcove roof penetration;2 feet above away combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension (if any) Mantel Height above fip opening Witness Operation Tank Placement(if LP) White—Building 13ept. � 'Yellow Cant er Pink—Fire Marshal Queensbury Building 8z Code Enforcement - ResidentialIal Inspection A Office No.(518)761-8256 Arrive: am/pm e f!� a m / 6 Date Inspection request received: _ _ _ Inspector's In' iais- NAME: a 1 RMIT#: LOCATION: —'A I ,�{� DATE: — — TYPE OF STRUCTURE: Comments Y N N/A J In Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" �,,,`� G� ��1�D`—�`� Roof Co lete/Exterior Finish Complete - Guard 30 in.or more(a)stairs,decks patios \ V Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete _t P� p� Qo, Interior/Exterior Railin s 34 in.to 38 Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" Gypsum Grade away from foundation 6 in.with 10 ft. �P— Handrail Termination at Newell Post or Wall ; ��4 ` 6 inch clearance to sill late Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace-area Furnace/Hot Water Heater operating Low water shut-off boiler / Relief Valves installed/Heat Trap/Water Temp 110 `� Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safet glazing `�� Interior Smoke De t tors: j� Every level: / Every Be oom: _a 'p( Outside every bedroom rea: Inter Connected: ! Battery backup: �J Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly o Gas Logs in Sealed or Glass E re I It , ,- Attic access 30 in.x 22 i in,(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s , ft.-150 s . ft. vents Building No. Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan (14-,*� As Built Septic System/Sewer Dept,4nspep ion Sticker Flood Plain Certification, if reqpifed A Okay to issue C/C or C/U Tem ora ermane L:\PamW\BuildinQ&Codes nsvection FormslRes. Final Insp. form 2.docLast printed 2/12/04 Town of Queensbury Fire Marshal 742 Day Road Queensbury,NY-12804 761_8205/761-820G Factory Built Gas Fireplace/Stove Inspection Report Notice:New York State requires that an U L Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions r s ecifications is allowed. Permit# 200� Schedule Inspection 1 ZtiimeL —jGi)pill anytime Inspector Name 7— i yyw Address FuI : l Rough In�Final Appliance Manufacturer_ QS�J Model# F3 3 9 Direct dent Factory Built Chimney Flue Size � Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible 1 construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension(if any) Mantel Height above f/p opening _ Witness Operation Tank Placement if LP / White—Building slept. —��— Yellow t luet er Pink—Fire Marshal Queensbury Building & Code Enforcement - Residential Final Inspection Office No. 518 761-8256 1 Arrive: am/pm ep Date Inspection request received: _ Inspector's Ini NAME: C1RMIT " LOCATION: j A A k -i!; _ DATE: __ l TYPE OF STRUCTURE: IS - - Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake �/y� 3 inch Plumb Vent through roof minimum 6" ��� `'''`' av -1 —/I ' Roof Complete/Exterior Finish Com lete _ 1 Guard 30 in.or more a�stairs, decks,patios �/j `7 � '�5 Tu Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors 7L Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" G sum t�� Grade away from foundation 6 in.witli 10 ft. Handrail Termination at Newell Post or Wall or 6 inch clearance to sill plate Gas Valve shut-off ex osed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site , _ Oil Furnace shut-off at entrance to furnace area �` �� �-E�� T tip Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 — ` �� v Interior privacy/trim/doors/main entrance 36 in. � Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Dete,tors: Every level: / Every Bedtoom: Outside every bedroom ea: �/ Inter Connected: Battery backup: � Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures G Foundation insulation Floor truss,draft stopping finished basement 1,000 sf --A Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly _ ���� - Gas Logs in Sealed or Glass Enclosure p , Attic access 30 in x z2 in x 3o in.(ht.)In accessible area Crawl SpacE Irrx 24"access, 1 sq. ft.-150 s . ft. vents Building No./Address visible from road Final Electrical 1 Site Plan /Variance required 1� " Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker . Flood Plain Certification, if required t" Okay to issue C/C or C/O orar /Permanent � � �, ���, i fir/ L:1PamW�BuildinQ&Codes pection Forms\Re . Fina rm 2, cS�print 2/12/04 \ Town of Queensbury Fire Marshal 742]day Road Queensbury,NY 12504 761-8205/761-8206 fax 7454437 Factory Built Wood Burning Fireplace/Stove Inspection Report Notice: New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit#1DO Schedule Inspection C _ p Time. ]] am pan anytime Inspector Name Z 1 Address Elrlo Q Rough In Final Appliance Manufacturer /" l a") Model# J z �57— Masonry Chimney Factory Built Chimney Flue Size '' Double WallyTriple Wall:Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Safety Strip Installation (fireplaces only) Firestop(s) Vertical Chase Wall Penetration Chimney Clearances to Combustibles Chimney Termination 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Combustion Air Hearth Extension J S S �>` Mantel (freight above Up openings Fireplace Doors /Screea' (required) wluite—Building Dept. yell- —Cus mer Pink—Dire Marshal Septic Inspection Report Office No. (518) 761-8256 Date Inspection req Istre e Queensbury Building& Code Enforcement Arrive: part: 742 Bay Rd., Queensbury,NY 12804 Inspector's Initial NAME: IZE IT NO.: Z—,CA 1�, LOCATION: _ 11 \ i �R PAR �_ SPECT ON: va "ZZ—O`-I RECHECK: Comments and/or diagram Soil Type- Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft• Well separation distance ft. Other wells: ft Absorption Field: Total length ft• Length of each trench ft. Depth of trenches ft. Size of Stone See a e Pits: Number Size: x Stone Size: • Piping Size Type bA Buildingto tank ��C�� Tank to Distribution Box Distribution Box to Field 7-Pit Opening Sealed: Y/N/Partial Location/Separations Foundation to tank ft• r� � — Foundation to absorption ft. Separation of Pits ft. _ Conforms as per Plot Plan `�� � �� Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: E�?D%approverd proved rtial Appoved and needs to be re-inspected, please call the Building&Codes Office LASueHemingway\Building.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 67 McDonald Street Glens Falls, NY 12801 December 16, 2004 Mr. John O'brien RECEIVE® Buildings and Codes Town of Queensbury G`i: 1 20C4 742 Bay Road Queensbury, NY 12804 TOWN OF QUEENSBURY PLANNING OFFICE Re: Septic System Jim Zappone Residence Fuller Road Town of Queensbury Dear Mr. O'brien: This letter is certification that the septic system plans for the Zappone residence that were submitted to you prior to the issuance of a building permit were prepared in conformance with the New York State Department of Health Individual Residential Wastewater Treatment Systems Design Handbook. This is to also certify the system was constructed in substantial conformance with those plans. If you should have any questions, please feel free to contact me at 793-4677. Sinc ely, D n Machell, P.E. �P�� OF NEW Y o gg. MACy�` ��, CFO 4,O 0580ar' - A��FESSIONA�- Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection reques re eived: Queensbury Building&Code Enforcement Arrive: 1/p• D art: _am/ 742 Bay Road, Queensbury, NY 12804 Inspector's Initi s: ' NAME: _ -�, 0'r2 PERMIT #: 0 �( --Z/ LOCATION: v �� INSPECT ON: %Off TYPE OF STRUCTURE: V N N/A PVC: R-1,R-25 R-3,R-4 Drain/Vents Cas ier Drain/Vent/ Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min. Drain Size Washing Machine Drain 2 inch min. Bead or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Coo r Commercial �o0 er,CPVC,Pex One and Two-Family sulation/Residential Check/Commercial Check Pro er Vent,Attic Vent Duct/Hot Water Piping Insulation V2 If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: LAS=Hemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insu.lation Inspection Report r�-- Office No. (51 8) 761-8256 Date Inspection reques ec v d: Queensbury Building& Code Enforcement Arrive: pn part: a 742 Bay Road, Queensbury,NY 12804 Inspector's Ini 'als NAME: PERMIT #:0 O N 11-2— LOCATION: jaj INSPECT ON: -- TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2, R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. 1g Vent/Vents in Place u Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper,CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If re uired unheated spaces Combustion Air Supply for Furnace Duct work sealed properl /No duct tape COMMENTS: LASuel-lemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insulation Inspection Report Office No. (51 8) 761-8256 Date Inspection request eiv d: O Queensbury Building& Code Enforcement Arrive: pm epa a 742 Bay Road, Queensbury,NY 12804 Inspector's Initi NAME: PERMIT #: /d LOCATION: j, (P INSPECT ON: to TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/gent/ Comm. -Phllfifflffl- /Vents in Place Rough Plu /Nail Plates z inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test -D -�� Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Family Insulation/Residential Check/ Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation \� If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct toe COMMENTS: L:\SueHemingway\$uilding.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November l7,2003 CA) Y\ 1�AX Rough ]Plumbing / Insulation Inspectio. Report Office No. (518) 761-8256 Date Inspection reques ece' Queensbury Building&Code Enforcement Arrive: pm part: r am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initia S' / 1 ,7 NAME: PERMIT #: L-. LOCATION: �� �,;/ (ate INSPECT ON: I TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates I % inch min.Drain Size Washing Machine Drain 2 inch min. Head or A' •Supply Test rain and Ven s 5 PS or 11 eet above hi hest V4 connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Au o er,CPVC,Pex One and Two-Family t,miulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: LASueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Town of Queensbury Fire Marshal 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Builvwooia B rning Fireplace/Stove Ins ection a ort Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's f instructions or specifications is allowed. Permit#�� G' �t �Qs;/ Schedule Inspection %� �� ime a pi°manytime Inspector c/ Name Address Rough In X Final D • ' i Appliance Manufacturer a, 11i , I�i Model 1,� Masonry Chimney Factory Built Chimney Flue Size l .Double Wall Liple Wall Insulated_ Yes No N/A Comments) FIoor Protection Y\ ��•� �' j l l��,� I,kN �' (�/J Clearances to Combustibles (all sides) � (������ U� �►c�yvuL2yv� � �'eL� h+�, Safety Strip Installation (fireplaces only) �'ICE �y/��. ���— Firestop(s) vertical Chase �Cj -- WWallPenetration►��---- k Chimney Clearances to Combustibles Chimney 'Termination 3 feet above roof penetration;2 feet above ��C �W any combustible construction within 10 feet Comb'tnstdon Air �Q,'�� atV I� Dearth Extensi®n f4 cv mf Y& Mantel(height above f/p opening) Fireplace floors Screen (required) � ✓��� ��tl� P White—Building Dept. yen. —Cus mer rr c Pink—Fire Marshal �� Town of Queensbury Fire Marshal 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Facto m�Gasfi;eace! tove Ins ectiorn Re_Dort Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit# �L'�' Schedule Iahspection7 Time �— aaffi anytime Inspector • Name__2 Address t! (�C ti4 `�� Rough In Final_ Appliance Manufaclurex. e Model# :Direct Ten&$ Factory Built Chimney Fine Size � .Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection M `� --n}�y TVa.11rlL� Clearances to Combustibles all sides Firestop(s) Vertical Chase_,_ �a�� �l b'�j�L 7 � ©K Wall Penetration Vent Clearances to Combustibles `lent/Chimney Termination i Chimney height int st be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air i'IOQ OK Hearth Extension if any) Mantel � — Ate, e, Height above f/p opening Witness Operation y ✓ Ate .. Tank Placement(if LP) r � '® ✓,j; t l hJ+� Whtte—Banding Dept. fellow Cust4ner Pink-1 re Marshal �'� ram. �` \ Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection req receiv �� ,©Q �f1L Queensbury Building& Code Enforcement Arrive: p art: a pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initi NAME: o PERMIT#: LOCATION: JAt, - ( INSPECT ON: T131104 70/A'-0(-) TYPE OF STRUCTURE: F l� Y N N/A COMMENTS ' Framing / Jack Studs/Headers Bracing/BridgingG� Joist hangers Jack Posts/Main Beams ( Exterior sheeting nailed properly `'�a' � V-- G�V, 12"O.C. Headroom 6 ft. 8 in. U L ��'1 �_i� $J ��L�,s , Stairwells 36 in. or more 1 T�fLj Ede v u� Headroom 6 ft. 8 in. � Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate �( 1 %2 (w)-16 gauge (8) 16D nails each side C-�'CL ;K L�- Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center �� ti �d�'J � TV, Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping --�- Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X �` r Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASue1-Iemingway\BuiIding.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p1v epart: U ZUM/Pm 742 Bay Road, Queensbury,NY 1.2804 Inspector's Initials: �VJ III NAME: O NC _ PERMIT#: (� . LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS Framing . Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 3 6 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %a(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses An or Bolts 6 ft, or less on center 00, ce and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.InspectionTORMSTraming Firestopping Inspection Report.doc January 28,2003 ram_ 1 Framing /Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: a n e art: am/pm 742 Bay Road, Queensbury,NY 1.2804 Inspector's Initials: NAME: PERMIT#: v7' A LOCATION: INSPECT ON: D TYPE OF STRUCTURE: Y N N/A COMMENTS Framing . Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses An hor Bolts 6 ft. or less on center ce and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing /Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: ' Queensbury Building&Code Enforcement Arrive: am/ Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials I NAME: .A-r-P6 JO'c� PERMIT#: LOCATION: '��( . V=cy Lu/2 INSPECT ON: j 0 TYPE OF STRUCTURE: Y N 'N/A COMMENTS Framing . Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft, floor trusses chor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour F' e wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 518 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Septic Inspection Report Office No. (518)761-8256 Date Inspection re est iv Queensbury Building&Code Enforcement Arrive: amlp epart: 0ja 742 Bay Rd., Queensbury,NY 12804 Inspector's Initia : ` Q NAME: IT NO.: nO O ' LOCATION: PECT ON: RECHECK: Comments and/or diagram Soil Type: an Loam/C1ay Type of Water: Municipal/ ell Water Waterline separation distance ft. Well separation distance — k Im _ Other wells: ft. Absorption Field: Total length Length of each trench ft. ` _ ��L� �,bT�C_ Depth of trenches ft• L l� Size of Stone Seepage Pits: Number Size: Stone Size: Piping Size a e Buildin to tank Tank to Distributioj'eld x Distribution Box to I Pit ko i Opening Sealed: /Partial Location/Se arations Foundation to tank ft• Foundation to absorption ft. Separation of Pits ft• Conforms as per Plot Plan Y N V3X=�- P\'D—' tN b��lc— pl_bT Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: Approved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved L:\SueHemingway\Building.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 t FULLER Rt P S 74'4214' " E 355.if RT ROAD L G 2,O•; OF A NEAP NDWHITE AND �IN� 3 �, MADELINE 911 189 `i WELL 100' MIN. GARAGE HOUSE 4' DIA, SOLID PVC PIPE, SCHEDUL i 0, 10' MIN TIGHT JOINTS, MINIMUM SLOPE 1/4, PER FT, 20' MIN, 1000 GALLON SEPTIC TANKS IN SE R DISTRIBUTION BOX INFILTRATOR SYSTEMS, INC. EQUALIZER 24 CHAMBERS TO BE INSTALLED LEVEL AND PARALLEL WITH NATURAL SLOPE PROPERTY LINE 10' MIN, Equalizer 24 Trench Detail (Not to Scale) 61 and for Proper Drainage EstabUsh Vegetative Cover •-+:C'- .Yi � i.' .,"it^t w•r .•+.C- .:.ti. 6' Min, -- 12' Max.\� Natfve 8'-24 24' MlnImum separatlon to seasonal high ground water 7�'uj�cr <` 'Y 058�" r "I have'seen or observed, or believe 1 sale evidence of, all, objects such as houses, wells, trees, €ernes, etc., shown on this document. I also represent that I h{We personal y measured th (stances set Terri oil t!ie diagram. . MAY 20, 2004 Z — JAMES M. ZAPPONE SIGN% � SEPTIC SYSTEM DESIGN TOWN OF QUEENSBURY, WARREN COUNTY DAN MACHELL, P.E. 67 MCDONALD STREET GLENS FALLS. NY 19801 f am, Foundation Inspection Report Office No. (518) 761-8256 Date Inspection reques c'e' ed: r Queensbury Building&Code Enforcement Arrive: all p. Depart' m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: _ NAME: PEI�AIIT#: LOCATION: _ ��� Q.✓ TNSPECT ON: — (� TYPE OF STRUCTURE: ` Comments Piers VX ethic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete, Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing "Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: T 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under SIab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:1Sue1-lemingway\Building.Codes.Inspection.FORMS\foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection re est r c 've Queensbury Building&Code Enforcement Arrive: pm Depart: a m 742 Bay Rd., Queensbury,NY 12804 Inspector's Im 1 NAME: P IT#: LOCATION: o SPECT ON: TYPE OF STRUCTURE: Comments Y N N/A noting Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump. Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:1SueHemingway\Building.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 % 1 Foundation Inspection Report Office No. (51S) 761-8256 Date Inspection request rece ved: Queensbury Building&Code Enforcement Arrive: am/ Depart: f am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: —L NAME: OY��_ . PERMIT#: LOCATION: l3 INSPECT ON: TYPE OF STRUC . Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour inforcementin Place • Foundati6n Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Surnp Footing Drain Stone: 12 inch width 6 ' es above footing mil poly for wet areas under slab ackfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection r e recei ed Queensbury Building&Code Enforcement Arrive: . a I Depart: a m 742 Bay Rd., Queensbuiy,NY 12804 Inspector's Initl j• NAME: - - — - PE IT#: LOCATION: INSPECT ON: TYPE OF STRUCT 7-X'1 Conunents Y N N/A OOtings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. - - Materials for this p ose on site. - - - - Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing / Type of Dampproofmg/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 RECEIVE® DEC 2 8--2004 TOWN OF QUEENSBURY `t n7 BUILDING AND CODE - oZ �J ate= FS >1 . "w .� 5 .......... ......................... I I I ..................._............. ..r_: :::: " I Ir _ ' s W. J. ROURKE, ASSOCIATES REcF 10264 SARATOGA ROAD MAR � Q 2004 P.O. BOX 1434 PHONE( 93- SOUTH GLENS FALLS FAX(518)79 798-9031 NEW YORK TOWN OF(�i.1Er.::" 13UBY 12803 BUILDIi�d'��;yp CpDE PERCOLAT: IDN TEST ON L.-AND QIF JAMEP _ARPUtlE. FULLER ROAD. TOWN! OF QUEENSBURY. TA.), i+lr F' PARCEL 1=-2-1-17 BY WILLIAM J. ROURKE. LAND SURVEYOR. fUNlE 14. 2-001. PERK= TEST: 501 EAST (DOWN SLOPE) FROM F-ROP+:F;ED HOUSE LCICA;TIOM. 8" TOPSOIL 8" - 30" FINE BROWN SAND NO WATER TABLE REACHED TEST - 1 21:30 MIN. TEST - ? �: 30 MIN. TEST - .3 2:30 MIN. PROPERTY&TITLE SURVEYS SUBDIVISION PLANNING&DESIGN SITE PLANNING MAPPING CONSTRUCTION SURVEYS y C e� I t ber N op _= j0 ��� oz A Ccheck Compliance Report Checked By/Dat—e" CODE - rYork State Energy Conservation Construction de , i��Cj¢GC av Ll wQl2 Version 33 Release lc Data filename-C-\Program Files\Check\MECcheck\ZAPPONE.cck TITLE:JIM&SHERI ZAPPONE . COUNTY:Warren STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached 1 or 2 Family. HEATING TYPE:Non-Electric DATE:08/13/03 DATE OF PLANS:AUGUST,11,2003 COMPLIANCE:Passes Maximum UA=597 Your Home=574 2.2%Better Than Code Gross . Glazing Area or Cavity _ Cont, or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Cathedral Ceiling(no attic) 1737 32.1 0.0 56 Ceiling 2:Flat Ceiling or Scissor Truss 92 30.0. 0.0 3 Wall 1:Wood Frame, 16"o.c, , 3833 19.0 0.0 181 Window l:Wood Frame,Double Pane with Low-E 48 0.300 14 Window 2:Wood Frame,Double Pane with Low-E 16 0.300 5 Window 3:Wood Frame,Double Pane with Low-E 14 0.300 4 Window 4:Wood Frame,Double Pane with Low-E 12 '0.300 4 Window 5:Wood Frame,Double Pane with Low-E 26 0300 8 Window 6:Wood Frame,Double Pane with Low=E 14 0.300 4 Window 7:Wood Frame,Double Pane with Low-E 71 0.300 .21 Window 8:Wood Frame,Double Pane with Low-E 48 0.300 14 Window 9:Wood Frame,Double Pane with Low-E 40 0.300 12 Window 10:Wood Frame,Double Pane with Low-E 47 0.300 14 Window 11:Wood Frame,Double.Pane with Low-E 14 0.300 4 Window 12:Wood Frame,Double Pane with Low-E 30 0.300 9 Window 13:Wood Frame,Double Pane with Low-E 23 0.320 7 Window 14:Wood Frame,Double Pane with Low-E 33 0.300 10. Door 1:Glass 40 0.300 I2 Door 2:Glass 120 0.310 37 Door 3:Glass 87 0.320 28 Door 4:Glass 20 0.310 6 Door-5:Glass 17 0.320 5 Door 6:'Solid 42 0.240 10 Door 7: Solid 36 0.240 9 Door 8: Solid 18 0.150 3 Basement Wall 1:Wood Frame,7.6'ht/6.0'bg/7.6'insul 1297 11.0 0.0 83 Basement Wall 2:Wood Frame,7.6'ht/0.0'bg/7.6'insul 111 19.0 0.0 7 Floor 1:All-Wood Joist/Truss,Over Outside Air 12 30.0 0.0 0 Floor 2:All-Wood Joist/Truss,Over Unconditioned Space 80 19.0 0.0 4 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief, and professional judgment,such plans or specifications are in compliance with this Code. Builder/Designer Date Aot /3 Zzn>3 '(�pF NEiyy ��PPOKEiry�d 09,f- s,P Q Q Z r CC Ld F � A 066� 2 �? F IONP MECcheck Inspection Checklist New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release 1 c DATE: 08/13/03 TITLE:JIM&SHERI ZAPPONE Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Cathedral Ceiling(no attic),R-32.1 cavity insulation Comments: [ ] 2. Ceiling 2:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: ] 1. Basement Wall 1:Wood Frame,7.6'ht/6.0'bg/7.6'insul,R-11.0 cavity insulation Comments: [ ] 2. Basement Wall 2:Wood Frame,7.6'ht/0.0'bg/7.6'insul,R-19.0 cavity insulation Comments: Windows: [ ) 1. Window 1:Wood Frame,Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: { J 2. Window 2:Wood Frame,Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?{ ]Yes{ ]No Comments: [ ) 3. Window 3:Wood Frame,Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 4. Window 4:Wood Frame,Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 5. Window 5: Wood Frame,Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 6. Window 6:Wood Frame,Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 7. Window 7:Wood Frame,Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ l I 8. Window 8:Wood Frame,Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 9. Window 9: Wood Frame,Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 10. Window 10:Wood Frame,Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 11. Window 11:Wood Frame,Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] I 12. Window 12:Wood Frame,Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] I 13. Window 13:Wood Frame,Double Pane with Low-E,U-factor:0.320 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 14. Window 14: Wood Frame,Double Pane with Low-E,U-factor:0.300 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: I Doors: [ ] 1. Door 1:Glass,U-factor:0.300 #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] I 2. Door 2:Glass,U-factor:0.310 #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] I 3. Door 3:Glass,U-factor:0.320 #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] I 4.. Door 4:Glass,U-factor:0.310 #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] I 5. Door 5:Glass,U-factor:0.320 #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 6. Door 6: Solid,U-factor:0.240 Continents: [ ] I 7. Door 7:Solid,U-factor:0.240 Comments: [ ] I 8. Door 8:Solid,U-factor:0.150 Comments: I Floors: [ ] I 1. Floor 1:All-Wood Joist/Truss,Over Outside Air,R-30.0 cavity insulation Comments: [ .] 2. Floor 2:All-Wood Joist/Truss,Over Unconditioned Space,R-19.0 cavity insulation Comments: I Air Leakage: [ ] S Joints,penetrations,rand all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-right assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R 11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] E3upplr ducte in unconditioned epaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R 2. Insulation is not required on return ducts in basements. Duct Construction: [ s] I All-joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exceptton:Continuously welded and locking-type longitudinal joints and seams on ducts F,pper4ting.at.jjpss than 2 in.w.g.(500 Pa). [ ] 'b&*A&hall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Coolllig+ducUs with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. 3JAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: [ !] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] { Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. i Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105°F or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 11, Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Ding System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only)