Loading...
2004-249 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20040249 Date Issued: Wednesday, January 25, 2006 . e This is to certify that work requested to be done as shown by Permit Number P20040249 has been completed. Tax Map Number. 523400-266-001-0001-014-005-0000 Location: 80 OAK VALLEY Way Owner. THOMAS & TERRI KUBRICKY Applicant: THOMAS & TERRI KUBRICKY This structure maybe occupied as a: Residential Addition By Order of Town Board (POOL 6 HOME THEATER) TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, G Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals.- ` TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes '(518) 761-8256 BUILDING PERMIT Permit Number: P20040249 Application Number: A20040249 Tax Map No: 523400-266-001-0001-014-005-0000 Permission is hereby granted to: THnMAS & TF,RRT KTTBRTCT(Y For property located at: 80 OAK VALLEY Way in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: THOMAS & TERRI KUBRICKY 80 OAK VALLEY Wav Residential Addition $62,000.00 Total Value $62,000.00 QUEENSBURY, NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2004-249 1680 sq ft RESIDENTIAL ADDITION $201.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,August 30, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To f Queens ury; onday,August 30, 2004 SIGNED BY / � for the Town of Queensbury. Director of Building li Co nforcement Building Permit;Application Town of Queensbury-Dept of Community Development,742 Bay Road,Queensbury,NY R ? 9 .0 04 (518)761-8256 _ `PO'yll� Oi=�'Jt"B;'I0RUr Y A permit must be obtained before beginning construction. Permijdi le No. o' ection will be made until applicant has received a Fee P �� N �P valid building permit.,All applicants' spaces on this Roe.Fee Paid $ application must be completed and must appear on the Reviewed By: application form. Applicant: T Pr6-Nl l-s £ FLYZW,1 VuP,a lj&Owner: SArt 0 Address: OA-1 L Address: i A r �.�.�.ra,t.t 12`( �._1.�-f • (28a Phone#{510)�3`12_- �� Phone#(Z1j) 7-- v_ � Property Location:--Lot Number:- / House Number_/ Subdivision Name: No(2T!-1 - Tax Map Numbar: a New Building: residence /commercial Estimated Market Value of Construction: $ e r �4•ll h x Addition: rear arc commercial If an Addition,what will use of new addition be? a Alteration: residence/ commercial - f 0-Rc- r k-C- Ttr: O No change to wderlor size: residence/com'1 o Other work(describe _- Check OccupancyWormation 1' Floor 2° Floor Other floor Total Below sq.ft. sq.ft: sq.ft. Square Feet j oSingle fautily dwelling 3 2- S 1 C08© av 1 , Two family dwelling ea Townhouse o Multifamily dwelling #of units .o Office o Mercantile a Manufacturing a 1 car detached garage a 2 car detached garage a 3 car detached garage a 1 car attached garage a 2 car attached garage a 3 car attached garage a Storage building- commercial o Storage building- residential a Other What is the proposed height of the structure 0 feet 1438 inches Will any second-hand or ungraded lumber be used? If so,for what? �j C) Type of Heating System: electric/ oil / gas/woo forced hod auk baseboard/other: - Number of Fimplaces to be installed .O Number of Woodsigves to be installed Q List below the person(s)responsible for supervision of work as regards to building codes: Phone Number X Builderp4au �I ��- X Plumber x Mason X Electrician ` Dec ration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Uwe shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of B ' Cc ,an Ag Buitt Survey by a licensed surveyor;drawn to scale,showing actual location of all new co Signature: owner,owner's agent,architect,contractor Queensbury Building & Code Enforcement -Re id is I 1 Inspection_ Office No. (518)761-8256 Arrive: art: r am/ m Date Inspection request received: Inspector's Initi NAME: IT M 04— LOCATION: P ATE: TYPE OF STRUCTU Comments Yes No N/A Building Number/Address visible from road J Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete ��Jf Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Batterybackup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window ` Plumbing fixtures Q Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/® [Temporary/Permanent] L:1Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised_100405.doc Resi ntial Queensbury Building & Code Enforcement - i al Inspection Office No. (518)761-8256 Arrive: D arx: Date Inspection request received: Inspector's Ini R r� NAME: E IT 4: LOCATION: IL D TE: TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Z Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy!trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s . ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp, 110 Enclosed Stairs Sheetrock Underside minimum%z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Lo sin Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/® [Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc Queensbury Building & Code Enforcement - Residential Fin nspection Office No. (518)761-8256 Arrive: am/pm- D Date Inspection request received: Inspector's Initials NAME: l AD .! T#: ( 1 -a� p� LOCATION: Ci r TYPE OF STRUCTURE: L Comments Yes No N/A Building Number/Address visible from road — CMG FVAN� 1W ; L Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake Q n S� `.CJ✓lam �C V``�� ���� 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more `(7 Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate _ Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches �� Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Batteg backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft,150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures _ Foundation insulation � ���'� Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler F L \ Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched /J Garage fireproofing/3/4 hour fire door/door closer q �� Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical �-o�-- t-' Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/C [Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form—revised-1 00405.doc Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection re�que r dived: Queensbury Building& Code Enforcement Arrive: Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initia s: ..� NAME: 1 , Rk C PERMIT #: Zj�)O�}-Z LOCATION: INSPECT ON: Z--Z TYPE OF STRUCTURE: Y N N/A; PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. lumbin Vent/Vents in Place Rough Plumbing/Nail Plates A L — 7 Zy ��t� 1 % inch min.Drain Size Apppbo Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial 1- Coo er, CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check F �� Proper Vent, Attic Vent �� Duct/Hot Water Piping Insulation If required unheated spaces u; Combustion Air Supply for Furnace Duct work sealed properly/No duct,ta e COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 7- �D'-3 Rough Plumbing / Insulation Inspection Report- Office No. (518) 761-8256 Date Inspection reques re v Queensbury Building& Code Enforcement Arrive: Z: rt; ICJ a� 742 Bay Road, Queensbury,NY 12804 Inspector's-In NAME: PERMIT #: LOCATION: C INSPECT ON: TYPE OF STRUCTURE: r Y N N/A PVC: R-1,R-2,R-3, R4 Drain/Vents & Cast Iron, Copper Drain/Vent/ Comm. ,/PlumbingVent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch nun. � ;�;, 7F Head or Air Supply Test ��✓w ,�� Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial oo er, CPVC,Pex One and Two-Family nsulation/Residential Check/Commercial Check Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces' l tJ �a�1�Lrt Combustion Air Supply for Furnace � � Duct work sealed properly'/No duct tape COMMENTS: r r rr, r LASueHemingway\Building.Codes.Inspection.FORM S\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insulation Inspection Report -141 Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm art: J am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: Y PERMIT #: ��CI LOCATION: (n 0gLk INSPECT ON: TYPE OF STRU TURE: - Y N N/A C: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. -PlumbingVent/Vents in Place /�S� N A-t L t,-Rou h Pflumbin /Nail Plates V 1 % inch min. Drain Size Washing Machine Drain 2 inch nun. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Co der Commercial 0o er,-CPVC,Pex One and Two-Family 'sulaiom/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required re uired unheated spaces / Combustion Air SR ply for Furnace {act work sealed properly/No duct toe A, COMMENTS: v C`c 1 L I /IJG�C-D 0,>L Fak LASueHemingway\l3uilding.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Framing / FirestoppingIns ec o Office No. (518) 761-8256 Date Inspection dim t ece'ved: Queensbury Building& Code Enforcement Arrive: epart: � �,'J rn742 Bay Road, Queensbury, NY 12804 Inspector's Initia NAME: ��fJ ^ PERMIT#: C� LOCATION: C)I—X Vok I to - INSPECT ON: TYPE OF STRUCTURE: 4ax Y N N/A COMMENTSG�,;raming Jack Studs/Headers _ Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. 1.t�l�L_ Headroom 6 ft. 8 in. �=kT- W N%-i_ Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls �t�cC aU` h'11�5 l l� L6J Fccu Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour 2 Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X _ _ Garage side 5/8 inch Type X �v� Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection req st re iu d: Queensbury Building&Code Enforcement Arrive: a p epart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initia s: r' NAME: &y��®� PERMIT#: -- y LOCATION: \1� � �,�p `� INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers ���� Bracing/Bridging Joist hangers pF Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade I-ASueHemingway\Building.Codes.Inspection.FORM STraming Firestopping Inspection Report.doc January 28,2003 Iy_. .lye ,.R;44;f_,,. J-r�`-.:iiF I.1}`:r:-!i:J.::$�S air � — _—� �l Tc`, c:"o:rd 2:t4 5RF :550f•1.5t �U� Li'SUr I] 2t' SPF �1 ra2 is PL.�rl:.-OL�!R_Ehi..-3.lsj ��Ey �r I iiebs 2%4 5QF Se.::c3 Tr ro: 32S ";.F at .$7 to T?.S-ps 3' 3k 22.54 � m :Lt Slider 2kb W ;,-!,Y2: BLOCK $9n° RC frog 20 PLC at Ll_00 CC 20 PtF at 21.07' :Rt Slider 2f6 SPF jl;kc2: MCK LENGTH - 1.899' Pi.3- 33 .a Cone. Load at (9;67a2:.27) U W m PLB- 33 LEConc_ LCad at 0- IL 40 ri.Dh wild, 25.96 ft r•.{ean hgt, ASCF 7"93r CLOSED bldg. -)I i Gated IF _j wikhin 4_50 ft from., roof edge, 100 ,€ from coast. CAT is EY,P C. wir:d 1C. IIJ LIEU rF STRUCTURAL PAMELS OP. RAM CEILIMa USE PLRLINS: cc OL-°5.0 psf, wind OC 0L=5.0 psf_ 010110 Spkclmcl& OC) STAPT(FT) c`"IO(1 O TC 29 -0.87 22.54 F_ Truss designed for unbalanced snow load using 0.00 windward factor and BC 120 10.00 21.67 � 1.50 leeward factor. 19 Miss supports 100P, nech unit; unit centered Q 10-10-4; supported by CD 4X5 sR) IN RC; unit width 2-4-0; supported by 3 trusses. RECEIVED N O DEC 16 2004 3X3 03 3X3S I OWN OF QUEENSBURY ry g BUILDING AND CODE g 8 003 00 in 33C4 a 3 K4% 1-0-0 1-0.0 ¢ 4X4= 3 X 4 04- 4X4(E3)_ 4X4(E3) Ld 3X41G3} yI 3k3(E3) loll J $ ItyB Its-10-0 _I_ 10-10-0 _l ry ----- 21-9-C Over 2 Suppcfts ----- R-1404 302 'd-5.5" R"=iy03 s1-'s02 {;"5.5a m PI_1_TYI_T4Jr1VE 'rp5 — - T_- 'Jesigrl C;it; TPI-1495;S70j 7.1 4T .5 NY '1i Le Scale =_2511rFt. QD 11{{ !OARNI$li-1 W*RS ['-l:?t WFA HZ `•l ]I•LU-FArLr•,,:+:0i GS:•'yi'S'[u•1:lLi fii}�I::p.�Y:A:�CI=SK%iIL.:-Sii�t 1 S3i4!`!l4l!,pS!,:c 1;,I-:fNCaL:�i1H,5:.!;:.1I'x:Q�I[tiL f"L?C�::1 A::r1!fDif a[ i•j{y4L'lia4:=, i.�V,�. TC U KI G USF REF _ t423 _3 i L[. ,qniC _1f Jv' _- Y _ ^ rl it.ili;X, ::},r;n.:^.!sa:Fl,t4A51 fiS i%-1:: la::I!!�i••v' f�_c::I,Lr;!:I,t lY.i4t R!.t'aN!SL -Cm, T4 L:],Q a'F DATE i +1 C• , y W :sa s.i.aF.�,s:.Y:::t'xi•a:1:f:.`!::�!..:Ix�..r.nA. I.L,'iLl eA-F.;1:JK r�Ji[I i•.il. .Aa! [ri.. ♦.a.� [fl-Cc U "LNFCRi tRc. .4- [{F! .: !�:v ra<IG,: ;,5",•.isi:S-:C•,IiA:1,A t;'.11f L.,lila I w j} f LLl +[. <r:Al Li^l fLRi:•,!4.E L4z ur L'C,::'1: fi'.a,a:•.R:5:6,[ a•f:•'.L:CI Eai r,1- ■AAA= GI ;L1Ur;E 1 - ... A7{' _ _4 _. _ �4. � V rS 7r.(Ilai •._.•. ffsl>l ir._[I;LY-:Vain+=i:ice:-i:l fliar:�:.�F,�_!.si iYr.7 i:�sF :.l's i�4 Tail,.fai A'wfJ.l a s:FrL; • !!,, . �•— _p+4l,1[=riA:i%"I :.:!• S: • .,. :E. }:Lt .{.a:!:srvF ter?G, a'r,Y i .Lit I'3.., Ci" ~I^ l !r!' i WT'- Chi`_I�J- 3a 't FLk;L%-.Fti-Y.I,[;f:f i¢,SI_ utll Si u �!-L`,-µ<I i[`•,% ,.I`- ..K, :1=' !i0• j� _I. t F Is!:•.rrl 4= t!s:Eirl..i 'Q' Sy girl v [��iR,F1iC. .L.,.17 L F"�''r r T :'I l E 5i •<p $ •sue iA'. !:sr _aEi - V..[�sl;C tl� irL L:1.4'IIYl':Cal'Lx:JISJ.IS,�l ii- .•r E _� � P _ }f f c;Si=_r Sa•.v. gp:lr __I: •a: LI;_n .u,l�ri:,n.y:�.t�,:x.15':.,, su err: V,�-.' �q 4V _-_A�^ I 1 ....._.�I.:II .,tib�ViJ — :I[rl[:LCi i,L:l.c:l`,AL.il rlfl ....._.._...----r.__,.._ �7 ) 'V'•'I�ftL:t1 C� i _iJ Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection re es re ry d: zL lok Queensbury Building& Code Enforcement Arrive: i/p part: m/ 742 Bay Road, Queensbury, NY 12804 Inspector's Initials` NAME: PERMIT#: Q)U LOCATION: INSPECT ON: b TYPE OF STRUCTURE: L`1� Poop, Framing Y N `^�v/� COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12 O.C. Headroom 6 ft. 8 in. _ Stairwells 36 in. or more Headroom 6 ft. 8 in. UJ. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate ���I .,� 1 '/2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour _ Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 518 inch Type X Garage side 5/8 inch Type X v V� Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) '67 5.7 sf above/below grade ' -� 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection re uest rece ed Queensbury Building& Code Enforcement Arrive: m/p e rt: i m 742 Bay Road, Queensbury, NY 12804 Inspector's Initi r v NAME: ) PERMIT#: LOCATION: N!i INSPECT ON: t j TYPE OF STRUCTU : 1 Y N 'v/A COMMENTS Jack Studs/Headers Bracing/Bridging i Joist hangers ��-�- Jack Posts/Main Beams Exterior sheeting nailed properly �- 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate ` 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Q)�Akt.\ U— � LA Penetration sealed 1 6 y 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doe January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/n Depart: m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials`' ,r NAME: ) PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing y N IN/A COM MENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor olts 6 ft. or less on center and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation. House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemin_way\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-82.56 Date Inspecti � U a�QD Qireersbury Building&Code Enforcement Arrive: Depart: a m 742 Bay Rd., Queensbury,NY 12804 Inspecto,Fn NAME: r rZ �LOCATION: t / () TYPE, OF STRUCTURE: Comments Footings �` Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site._ _ Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASucHemingwav\Bui Win g.Codes.Inspection.FO WSW oundation Inspection Report.doe January 28,2003 '4 ao� a Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheck Sollware Version 3.6 Release la Data filename: Untitled.rek PROJECI'TITLE: THOMAS AND TERRI KUBRICKY CITY: Glens Falls STATE: New York HDD: 7635 CONSTRUCTION TYPE: Single Family - WINDOW /WALL RATIO: 0.24 DATE: 12/01/04 DATE OF PLANS: 10/28/04 COMPLIANCE: Passes Maximum UA= 503 Your Home UA=464 7.8%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 1012 38.0 0.0 30 Wall l: Wood Frame, 16" o.c. 1772 19.0 0.0 79 Window 1: Wood Frame:Double Pane with Low-E 172 0.340 58 Door 1: Glass 249 0.340 85 Door 2: Solid 38 0.100 4 Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 816 19.0 0.0 38 Floor 2: Slab-On-Cnade:Heated 236 10.0 170 Insulation depth: 2.6' Furnace 1: Forced Hot Air, 90 AFUE Air Conditioner 1: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 TECC requirements in REScheck Version 3.6 Release la(formerly MECcheck) and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. -BuH4erfDesigner Date Z l 1 REScheck Inspection Checklist 2000 IWC REScheck Sol-ware Version 3.6 Release la DATE: 12/01/04 PROJECT TITLE: THOMAS AND TERRI KUBRICKY Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-38.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Wood Frame:Double Pane with Low-E, U-factor 0.340 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: Doors: [ ] 1. Door 1: Glass, U-fictor: 0.340 Comments: [ ] 2. Door 2: Solid, U-factor. 0.100 Comments: Floors: [ ] 1. Floor 1: All-Wood Joist/Truss:Over Unconditioned Space, R-19.0 cavity insulation Comments: [ ] 2. Floor 2: Slab-On-Grade:Heated, 2.6'insulation depth, R-10.0 continuous insulation Comments: Slab insulation to extend down from the top of the slab to at least 2.6 It. OR down to at least the bottom ofthe slab then horizontally for a total distance of2.6 f. Exterior insulation must have a rigid, opaque, weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in. below grade. Heating and Cooling Equipment: [ ] 1. Furnace 1: Forced Hot Air, 90 AFUE or higher Make and Model Number [ ] 2. Air Conditioner 1: Electric Central Air, 10 SEER or higher Make and Model Number Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated, or 2)installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. Tfnon-TC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non vented framed ceilings, walls, and floors. Materials identification: [ ] Materials and equipment must be installed in accordance with the manufacturers installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R values, glazing U-faactors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must berated UL 181A or UL 181B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The HVAC system must provide a means for balancing air and water systems.. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut offthe heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% ofthe heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55°F must be insulated to the levels in Table 2. v t Table]: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" -Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness fur HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pine Sizes Piping System Types Range F 2"Runouts 1" and Less 1.25"to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only) SAVE qA i r 1-4 8_Z` -04- IOBIC��,�-1, 14cf-EP -To / 2,. x-Ooc--n "j @ E:L ev/4-7a-r2 S i+, �=T E sue- OT'e' RT o F- T(--rp t;)d-L-J J `t`d Fovmos (PAC �- /4 '. J�J(�-r5 /5, `( �v .6e-L F C,Los 10 G F- , r-A G ES O-A) 4e a �o o • am a • \ + Q Y ^ H • M Z r c o `•�i� UNN� •' Av o 14 Si . oIN 01 48 114 ••• kA L �WVY ` Q e M O �J INLi W I tu a tv 14 1 W