Loading...
insulation depth report �ZG-b-TUS-- Z-O\C\ (Nf zero =---==----=- --------- The Foam Guys Spray Foam Solutions December 27, 2019 DEPTH REPORT 'LEASE NOTE: This document is intended for the use of NY State Building nd Code requirements. PROJECT: 4 Glendale Ave. Queensbury, NY 12804 SIGNEE: Bill Miner 518-260-3209 Roof Slopes(Closed Cell) RValue(41 .25) Depth(5.5 inches) "Product used was Demelic HFO High Lift Closed Cell Sprayfoam." I, Nick Sciald e, sta these RValues and Depths are correct. 12/27/19 Nick Scialdone Date 698 Route 29 1-877-330-,'FOAM Saratoga Springs 518-932-2989 New York 12866 ESIcc IMES Evaluation Report ESR-4073 Reissued August 2019 This report is subject to renewal August 2020. www.icc-es.org 1 (800)423-6587 1 (562)699-0543 A Subsidiary of the International Code Council® DIVISION:07 00 00—THERMAL AND MOISTURE The attributes of the insulation have been verified as PROTECTION conforming to the provisions of ICC 700-2008 Section Section:07 21 00—Thermal Insulation 703.2.1.1.1(c) as an air impermeable insulation. Note that decisions on compliance for those areas rest with the user REPORT HOLDER: of this report. The user is advised of the project-specific provisions that may be contingent upon meeting specific DEMILEC(USA)INC, conditions, and the verification of those conditions is outside the scope of this report.These codes or standards EVALUATION SUBJECT: often provide supplemental information as guidance. HEATLOW HFO HIGH LIFT SPRAY FOAM 3.0 DESCRIPTION INSULATION 3.1 General: 1.0 EVALUATION SCOPE Demilec Heatlok®HFO product is a rigid, medium-density, spray-applied cellular polyurethane foam plastic insulation 1.1 Compliance with the following codes: installed as a component of wall assemblies, ceilings, ■ 2018, 2015, 2012 and 2009 International Building floors, crawlspaces and cavities of roofs.The foam plastic Code®(IBC) insulation is a two-component, closed-cell, one-to-one by volume spray foam system with a nominal density of ■ 2018, 2015, 2012 and 2009 International Residential 2.0 pcf(32 kg/m3). The insulation is produced in the field Code®(IRC) by combining a polymeric isocyanate (A component) with ■ 2018, 2015, 2012 and 2009 International Energy a polymeric resin blend (B component). The insulation Conservation Code®(IECC) components have a shelf life of six months when stored in factory-sealed containers at temperatures between 50°F Property evaluated: (10°C)and 80*F(26°C). ■ Surface-burning characteristics 3.2 Surface-burning Characteristics: ■ Physical properties Demilec Heatloe HFO product,at a maximum thickness of 4 inches (102 mm) and a nominal density of 2.0 pcf ■ Thermal resistance (32 kg/m3), has a flame spread index of 25 or less and a ■ Attic and crawl space installation smoke-developed index of 450 or less when tested in ■ Water vapor transmission accordance with ASTM E84 (UL 723). There are no thickness limitations when insulation is covered by a ■ Air permeability code-prescribed 15-minute thermal barrier. ■ Exterior walls in Types I through IV construction 3.3 Thermal Resistance(R-values): 1.2 Evaluation to the following green standard: Demilec Heatloe HFO product has thermal resistance (R-value),at a mean temperature of 75°F(24°C),as shown ■ 2008 ICC 700 National Green Building Standard m(ICC in Table 1. 700-2008) 2.0 USES 3.4 Vapor Permeance: Demilec Heatlok® HFO has a vapor permeance of Demilec Heatlok® HFO closed cell spray foam is a 1.0 perm or greater and less than 10 perms when applied spray-applied polyurethane foam plastic insulation used as at a minimum of 1 inch (25.4 mm)thickness and may be a nonstructural thermal insulating material in Types I, 11, 111, used where a Class III vapor retarder is required by the IV and V construction under the IBC and in dwellings under applicable code. the IRC.The insulation is intended for use in wall cavities, floor/ceiling assemblies, or attics and crawl spaces when 3.5 Air Permeability: installed in accordance with Section 4.4. Under the IRC Demilec Heatlok® HFO foam plastic insulation, at a and 2018 and 2015 IBC, the insulation may be used as minimum 1-inch (25.4 mm) thickness, is considered air-impermeable insulation when installed in accordance air-impermeable insulation in accordance with 2018, 2015 with Section 3.5. The insulation also may be used in and 2012 IRC Section R806.5 (2009 IRC Section R806.4) exterior walls of Type I, II, III or IV construction when used and 2018 IBC Section 1202.3 [2015 IBC Section 1203.3] as described in Section 4.5. based on testing in accordance with ASTM E283. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed as an endorsement ofthe subject ofthe report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,as To to any finding or other matter in this report,or as to any product covered by the report. - Copyright©2019 ICC Evaluation Service,L.L.C. All rights reserved. Page 1 of 4 ESR-4073 I Most Widely Accepted and Trusted Page 2 of 4 3.6 Blazelok TBX Intumescent Coating: 4.3.2.2 The maximum installed thickness of the insulation BlazelokTm TBX intumescent coating (see ESR-3997), must not exceed the thickness set forth in Table 2. manufactured by TPR2 Corporation, is a one-component 4.3.3 The coating must be applied over the insulation in water-based liquid coating. The coating is supplied in accordance with the coating manufacturer's instructions 5-gallon (19 L) pails and 55-gallon (208 L)drums and has and respective ICC-ES evaluation report for the coating a shelf life of (1) year when stored in factory-sealed and this report. containers at temperatures between 45°F (7°C) and 95°F 4.4 Ignition Barrier—Attics and Crawl Spaces: (35°C). 3.7 DC 315 Intumescent Coating: 4.4.1 Application with a Prescriptive Ignition Barrier: When Demilec Heatloe HFO insulation is installed within DC 315 intumescent coating (see ESR-3702), attics or crawl spaces where entry is made only for service manufactured by Intemational Fireproof Technology, Inc., of utilities, an ignition barrier must be installed in is a water-based coating supplied in 5-gallon (19L) pails accordance with IBC Section 2603.4.1.6 and IRC Sections and 55-gallon (208L)drums and has a shelf life of one (1) R316.5.3 and R316.5.4, as applicable, except when the year when stored in factory-sealed containers at installation is in accordance with Section 4.4.2.The ignition temperatures between 50°F(10°C)and 80°F(24°C). barrier must be consistent with the requirements for the 4.0 DESIGN AND INSTALLATION type of construction required by the applicable code, and must be installed in a manner so that the foam plastic 4.1 Design: insulation is not exposed. The attic or crawl space area Demilec Heatlok® HFO product must be installed in must be separated from the interior of the building by an accordance with the manufacturer's published installation approved 15-minute thermal barrier as described in instructions and this report. A copy of the manufacturer's Section 4.3.1. published installation instructions must be available at all Demilec Heatlok® HFO insulation, as described in this times on the jobsite during installation. section, may be installed in unvented attics in accordance 4.2 Application: with 2018, 2015 and 2012 IRC Section R806.5 (2009 IRC The insulation is spray-applied on the jobsite using Section R806.4) or 2018 IBC Section 1202.3 [2015 IBC equipment identified in the manufacturer's published Section 1203.3]. installation instructions. The Demilec Heatlok® HFO 4.4.2 Application without a Prescriptive Ignition product must be applied when the ambient and substrate Barrier: Where the spray-applied insulation is installed in temperature is between 50°F (10°C) and 100T (38°C). accordance with Section 4.4.2.1, the following conditions The insulation must not be used in areas that have a apply: maximum service temperature greater than 180°F (82°C). a) Entry to the attic or crawl space is to only service The foam plastic insulation must not be used in electrical utilities,and no storage is permitted. outlet or junction boxes or in continuous contact with rain or water. The substrate must be free of moisture, frost or b) There are no interconnected attic or crawl space ice, loose scales,rust,oil and grease,or contaminates that areas. will interfere with adhesion of the spray foam insulation. c) Air in the attic or crawl space is not circulated to other The Demilec Heatlok® HFO product may be applied in parts of the building. passes having a maximum thickness of 61/2 inches d) Attic ventilation is provided when required by 2018 (165 mm) per pass. When multiple passes are required, IBC Section 1202.2.1 [2015, 2012 and 2009 IBC subsequent passes can be sprayed once the core Section 1203.2] or IRC Section R806, except when temperature drops below 100°F(37.7°C). air-impermeable insulation is permitted in unvented 4.3 Thermal Barrier: attics in accordance with the 2018 IBC Section 1202.3 4.3.1 Application with a Prescriptive Thermal Barrier: [2015 IBC Section 1203.3] or 2018, 2015 and 2012 Demilec Heatlok® HFO insulation must be separated from IRC Section R806.5(2009 IRC Section R806.4). the interior of the building by an approved thermal barrier e) Under-floor(crawl space)ventilation is provided when of Y.-inch-thick (12.7 mm) gypsum wallboard or an required by 2018 IBC Section 1202.4 [2015 IBC equivalent thermal barrier complying with and installed in Section 1203.4 (2012 and 2009 IBC Section 1203.3)] accordance with the applicable code except where the or IRC Section R408.1,as applicable. installation complies with the requirements set forth in Combustion air is Section 4.3.2. When installation is within an attic or crawl fl provided in accordance with space as described in Section 4.4, a thermal barrier is not Intemational Mechanical Code®Section 701. required between the foam plastic and the attic or crawl 4.4.2.1 Application without a Prescriptive Ignition space, but is required between the insulation and the Barrier: In attics and crawl spaces, Demilec Heatlok®HFO interior of the building, insulation may be spray-applied to the underside of roof There is no thickness limit when installed behind a code- sheathing and/or rafters, and to vertical surfaces and the prescribed thermal barrier except as noted in underside of floors as described in this section. The thickness of the foam plastic applied to the underside of Section 4.4.2.1. the overhead surfaces (roof sheathing, rafters and the 4.3.2 Application without a Prescriptive Thermal underside of floors)must not exceed 71/4 inches(184 mm). Barrier: Heatlok® HFO spray foam insulation may be The thickness of the foam plastic applied to vertical installed without the prescriptive 15-minute thermal barrier surfaces must not exceed 111/4 inches (286 mm).The attic or ignition barrier described in Section 4.3.1 or or crawl space must be separated from the interior of the Section 4.4.1, respectively when installation is in building by an approved thermal barrier as described in accordance with the following: Section 4.3.1. 4.3.2.1 The insulation must be covered on all surfaces 4.4.3 Use on Attic Floors: Demilec Heatlok° HFO with a fire protective coating at the minimum thickness set insulation may be installed at a maximum thickness of forth in Table 2. 71/4 inches (184 mm) between and over joists in attic rESR-4073 I Most Widely Accepted and Trusted Page 3 of 4 floors. The Demilec Heatlok® HFO insulation must be (2009 IECC Sections 303.1.1 and 303.1.1.1), as separated from the interior of the building by an approved applicable. thermal barrier. 5.9 The insulation components A and B are produced in 4.5 Exterior Walls of Type 1,II,III and IV Construction: Arlington, Texas and Boisbriand, Quebec, Canada, 4.5.1 General: When used on exterior walls of Type I, 11, under a quality control program with inspections by Ili, and IV construction, the assembly must comply with ICC-ES. Section 2603.5 of the IBC and this section, and the 6.0 EVIDENCE SUBMITTED Demilec Heatlok® HFO insulation must be installed at a 6.1 Data in accordance with the ICC-ES Acceptance maximum thickness described in Table 3. The potential Criteria for Spray-applied Foam Plastic Insulation heat of Demilec Heatlok® HFO insulation is 2300 Btu/ftz d p (26 Mj/m2)per inch of thickness when tested in accordance 2018), i dated April 2016 (editorially revised April with NFPA 259. 2018), including reports of tests in accordance with AC377 Appendix X. 4.5.2 Specific Wall Assemblies: Wall assemblies 6.2 Reports of air leakage testing in accordance with complying with Section 4.5 must be as described in ASTM E283. Table 3. 5.0 CONDITIONS OF USE 6.3 Reports of water vapor transmission test in accordance with ASTM E96. The Heatlok®HFO spray foam insulation described in this 6.4 Reports of room corner tests in accordance with report complies with, or is a suitable alternative to what is NFPA 286. specified in,those codes listed in Section 1.0 of this report, subject to the following conditions: 6.5 Reports of fire propagation characteristics tests in 5.1 The products must be installed in accordance with the accordance with NFPA 285. manufacturer's published installations instructions, 6.6 Reports of potential heat of foam plastic tests in this evaluation report and the applicable code. If there accordance with NFPA 259. are any conflicts between the manufacturer's 6.7 Supplementary fire engineering analysis. published installation instructions and this report, this 7.0 IDENTIFICATION report governs. 5.2 The insulation must be separated from the interior of 7.1 Components of the insulation are identified with the the building by an approved thermal barrier, except manufacturer's name [Demilec (USA) Inc], address when installation is as described in Sections 4.3.2 and and telephone number; the product name (Demilec 4.4.2.A thermal barrier must be installed between the Heatlok® HFO B-side or A-PDMI); use instructions; insulation and the interior space above (crawl space) the density; the flame-spread and smoke-developed or below(attic). indices; the date of manufacture; thermal resistance values; and the evaluation report number 5.3 The insulation must not exceed the thicknesses noted (ESR-4073). in this report based upon the intended end use. The TPR2 Corporation BlazelokTm TBX intumescent 5.4 The insulation must be protected from exposure to coating and primer is identified with the weather during and after application. manufacturer's name, the product name, use 5.5 The insulation must be applied by contractors instructions and ICC-ES evaluation report number authorized by Demilec(USA)Inc. ESR-3997. 5.6 Use of the insulation in areas where the probability of The International Fireproof Technology / Paint To termite infestation is `very heavy" must be in Protect, Inc. DC 315 intumescent coating is identified accordance with 2018, 2015, and 2009 IBC Section with the manufacturer's name, the product trade 2603.8 (2012 IBC Section 2603.9) or IRC Section name, use instructions and ICC-ES evaluation report R318.4,as applicable. number ESR-3702. 5.7 When use is on exterior walls of buildings of Types I, 7.2 The report holder's contact information is the II, III, and IV, construction must be as described in following: Section 4.5. DEMILEC(USA)INC. 5.8 Jobsite certification and labeling of the insulation must 3315 EAST DIVISION STREET comply with 2018 or 2015 IRC Sections N1101.10.1 ARLINGTON,TEXAS 76011 and N1101.10.1.1 (2012 IRC Sections N1101.12.1 (817)640-4900 and N1101.12.1.1 or 2009 IRC Sections N1101.4 and www.demilecusa.com N1101.4.1)]and 2018, 2015 and 2012 IECC Sections C303.1.1, C303.1.1.1, R303.1.1 and R303.1.1.1 f-SR-4073 I Most Widely Accepted and Trusted Page 4 of 4 TABLE 1-THERMAL RESISTANCE(R-VALUES) THICKNESS(inches) R VALUE('F.ft2.h/Btu) THICKNESS(inches) R VALUE('F.ff'.h/Btu) 1.0 6.3 7.0 52 1.5 10 7.5 56 2.0 14 8.0 60 2.5 18 8.5 64 3.0 22 9.0 67 3.5 26 9.5 71 4.0 30 10.0 75 4.5 34 10.5 79 5.0 37 11.0 82 5.5 41 11.5 86 6.0 45 12.0 90 For SI:1 inch=25.4 mm;1'F.ft2.h/Btu=0.176 110'K.m2/W. 'R-values are calculated based on tested K-values at 1-and flinch thicknesses. TABLE 2-USE OF INSULATION WITHOUT A PRESCRIPTIVE THERMAL BARRIER(TESTED IN ACCORDANCE WITH NFPA 286) MAXIMUM MAXIMUM COATING TYPE 8 Sz' MINIMUM MINIMUM THICKNES INSULATION TYPE THICKNESS(in.) THICKNESS(in.) APPLICATION RATE (Vertical Surfaces) (Overhead Surfaces) (Applied to all Foam OF COATING Surfaces Blazelok TBX Heatlok HFO 71/2 111/2 18 mils WFT 1.2 gal/100 ft2 12 mils DFT DC 315 Heatlok HFO 71/2 111/2 18 mils WFT 1.125 gal/100 ft2 12 mils DFT For SI:1 inch=25.4 mm;1 mil=0.0254 mm;1 gallon=3.38 L;1 ft2=0.93 m2. Notes: 'See Section4.32 2DFT=Dry Film Thickness;WFT=Wet Film Thickness 'See Sections 3.6 and 3.7. TABLE 3-NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES-WALL CAVITY INSULATION WALL COMPONENT MATERIALS Base Wall System- 1-Concrete wall. Use either 1,2 or 3 2-Concrete masonry wall. 3-Minimum 35/g-inch-deep(92 mm),No.25 gage,C-shaped steel studs,spaced a maximum of 24 inches on center with lateral bracing every 4 feet(1219 mm)as required by code.Interior sheathing must be 1 layer 5/a-inch-thick(19.1 mm)Type X gypsum wallboard complying with ASTM C1396. Exterior Sheathing shall be a described in Exterior Sheathing below. Floodine Firestopping Minimum 4 pcf mineral wool in each stud cavity at each floodine,attached with Z-clips.Thickness must match stud cavity depth. Perimeter Fire Barrier System Perimeter fire barrier system complying with 2018,2015 and 2012 IBC Section 715.4(2009 IBC Section 714A)must be installed to fill the void between the edge of the concrete floor slab and the interior surface of the exterior wall assembly. Cavity/Interior Insulation-Use either 1-None. 1,2,3,4 or 5; 2-35/8 inches(92 mm)of Heaflok®HFO applied to the interior surface of Base Wall System 1 or 21. (Note:Cavity Insulation No.3 may be 3-Full cavity depth not exceeding 35/8 inches(92 mm)of Heatlok®HFO. combined with No.4 or Cavity 3-Any insulation qualified as noncombustible in accordance with ASTM El36. Insulation No.3 may be combined with 4-Glass fiber batt insulation°. No.5 to achieve depth of insulation 5-Mineral fiber insulationb. required) 8 Fireblocking in accordance with 2018,2015 and 2012 IBC Section 718(2009 IBC Section 717)and thermal barrier material requirements in accordance with IBC Section 2603.4 shall be met for Base Wall Systems 1 and 2,when a combustible concealed space is present on interior side of the exterior wall assembly. b Insulation must comply with the applicable requirements of 2018,2015 or 2012 IBC Section 720.2 (2009 IBC Section 719.2). Exterior Sheathing-Only for Base Wall Minimum 5/a-inch-thick(19.1 mm)glass mat gypsum sheathing complying with ASTM C1177. System No.3- Sheathing shall be attached with No.6,1'/4-inch-long(32 mm)self-tapping screws located 8 inches (203 mm)on center along the perimeter and 12 inches 302 mm)on center in the field of wallboard. Joints must be taped and treated with joint compound in accordance with ASTM C840 or GA-216. Exterior Wall Covering- 1-Any noncombustible exterior wall covering material using any standard installation technique Use either 1 or 2 (Base Wall 1 or 2) 2-Any noncombustible exterior wall covering system with a combustible WRB that has successfully been tested in accordance with NFPA 285.(Base Wall 3) Details of the exterior wall covering must be provided to the code official by the report holder, designer or specifier,with an engineering analysis demonstrating that(1)the exterior wall covering conforms to ASTM El36 and(2)the addition of the wall covering and/or water-resistive barrier to the assembly described in this section does not negatively affect conformance of the assembly with the requirements of IBC Section 2603.5.