Loading...
2004-383 TOE OF QUEENSBURY FILE Copy 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20040383 Date Issued: Thursday, December 02, 2004 This is to certify that work requested to be done as shown by Permit Number P20040383 has been completed. Tax Map Number: 523400-315-010-0001-016-000-0000 Location: 10 QUINCY Ln Owner: MICHAELS GROUP LLC THE Applicant: MICHAELS GROUP LLC THE This structure may be occupied as a: By Order of Town Board Fireplace TOWN OF QUEENSBURY Garage - 2 Cars Attached Single Family Dwelling Director of Building&Code nforce ent BLDG. PERMIT NO. 2004-383 FILE APPLICATION FOR A TEMPORARY CERTIFICATE OF OCCUPANCY A TEMPORARY CERTIFICATE OF OCCUPANCY is hereby requested for the property located at; 10 Quincy, Lane for'the following uses: S-Lngt e Farti.t, y Dwe. -;.ng Oci-obex 29, 2004 DATE SIGN URE OF APPLICANT TEMPORARY CERTIFICATE OF OCCUPANCY The TEMPORARY.CERTIFICATE OF OCCUPANCY is hereby 010PROVED ( )DISAPPROVED with the following conditions: TempOka y E .in.6ta.0 ,tempered bo:uoin zaz at bai6vcoorn window . TEMPORARY CERTTIFICATE OF OCCUPANCY EE: O$10.0• DE )$100.00 received on -- Date of ss nce Di of BMg. Code Enforcement TINS TEMPORARY CERTIFICATE.OF OCCUPANCY EXPIRES 3d DAYS FROM THE DATE OF ISSUANCE. NOTE: This Certificate is NOT VALID unless signed by the Director of Bldg. & Code Enforcement or his designee. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040383 Application Number: A20040383 Tax Map No: 523400-315-010-0001-016-000-0000 Permission is hereby granted to: M1CffART,S ('TROT TP T,T,C; THR For property located at: 10 QUINCY Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tie of Construction Value Owner Address: MICHAELS GROUP LLC THE 10 BLACKSMITH Dr Fireplace MALT NY 12020-0000 Garage-2 Cars Attached Single Family Dwelling $259,900.00 Total Value $259,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2004-3 83 Lot 16, House No. 10 Quincy Lane 2364 SQ FT SINGLE FAMILY DWELLING $327.68 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, June 08,2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Tuesday,June 08, 2004 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement LBuilding Permit application Town oI QLicenshry—Dept Of C01111111.IIllty Dcvelopment, 742 Bay Road, Quee"sbury, NY (518) 761-8256 A permit nulst be obtained before beginning construction. Permit File No. No inspection will be "lade until applicant has received a Fcc Paid valid building permit. All iplilic-an(s' splices on tliis IZcc. I cc Paid application must be completed and I11LIst appear on the Reviewed .By: application form. ��E1 ���� Cr7.Ya Applicant: Owner: Address: � 1�n 'bruj�, Address: Phone Phone## ( ) - Property Location: Lot Number: Igo / house Number 10 Subdivision Name: Tax Map Number: XNew Building: residence /conuricrcial Estimated Market Value of Construction: $ 2 59 ,°1 Oc� ❑ Addition: residence/ conlnlcrcial If an'Addition, what will use of new addition be? ❑ Alteration: residence/ Commercial. I� 1 ❑ No change to exterior size: residence/com'1 � � ``y I •w�' it� ❑ Other work(describe ) JUN 0 1 2004 Check OccupancylnforI11.1tio11 I" Moor 42'j'i?lii,pi; •;;t) Olhci noon 1'olal 13c1o1v �-- ._�. _ _.__ sq. R. sq. fL— - sq. ft, square beet I Single family dwelling 1 Z Sc7 1 1 1 4- Z 3to 4 ❑ Two family dwelling ❑ Towtlhouse ❑ Multifamily dwelling #of units ❑ Office ❑ Mercanti le ❑ Manufacturing ❑ 1 car detached garage ❑ 2 car detached garage ❑ 3 car detached garage ❑ 1 car attached garage 2 car attached garage 440 ❑ 3 car attached garage ❑ Storage building- — - Commercial ❑ Storage building- residential ❑ Other Will any second-hand or ungraded lumber be used? If so, for what? Wk , Type of Heating System: electric/ oil / gas wood / forced_]lot air/ baseboard/other: Number of'Rreplaces to be installed Number of Woodstoves to be installed List below the person(s) responsible for supervision of work as regards to building codes: Name Address Phone Number Plumber ��C. l' I�mh�nc\_ Mason J D F-'0UCj 1ER- BOY, zloe jp--* V►t-LE b32 - 91%a Electrician At-EaF- S El-1E=-r7M C- Roc '78 FoRT HuNTe_7_ 3(0'� - 214 S Declaration: please sign below;Iflcr you linve carefully rend the slulenlenl: To the best of illy knowledge the statements contained in this application, together with the plans and specifications subinillcd, are a u-uc and complete statement of all proposed work to be done on the described premises and that all provisions of the 1hilding Code, the 7oning Ch(linancc alld all Other la\vs 11Crfaliiing to the proposed lvork shall he conlplictl with, whether specified or noted, aild that such work is au(horized by the owner. Furlhcr, it is understood that I/wc shall submil, prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Adnlinislralor or Director of Building and Codcs, an ifs Blurt Stirre,by a licensed surveyor;drawn to scale.,showing actual location of all new conslr lion. Signaltirc:_ _-_ __ owner,Owner's agent, architect, Contrrador Check Residential Plan Review: One & Two Family Dwellings Y 2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade, 5.7 sq. ft. Grade,5.0 sq. It. 24"(h)x 20"(w)min. 44"Max.Height above floor esidential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofmg/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6"Drop in 10'Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where Re uired tee and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise Winder Run and Rise Spiral Not Allowed From 2n Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper CIearance Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation arage Floor Sloped ttic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed Application for Permit=Septic Disposal System Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 1. OWNER INFORMATION: i Office Use Location of installation: 1 O GilN C-C LANF. l L-OT #1(0) I File Permit No. - Tax Map No. Fee Paid Owner's Name: G T4F-��� p` -S �OVP Address: 10 2. INSTALLER'S NAME : ��r� �S �Vo��� PHONE NO. fq!2­ ,e 1 j 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No.of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gal/bdrm = 1980- 1991 x 130 gal/bdrm = 1991 -present G]- x 110 gal/bdrm. = Garbage Grinder Installed yes_ / no e Spa or Hot Tub Installed yes_ / no 4: PARCEL INFORMATION: (circle applicable information&indicate measurements) ToDop.ra,ohv Sail-Nature Ground Water Bedrock or impervious Material . Domestic Water SlIpply la Wam at w at depth at what depth municip olling I Y&feet feet well Steep slope clay if well, water supply _%slope other from any septic-system depth: absorption is ft. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: minute per inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: 1262' gallon(min. size 1,000 gal) Tile Field: each trench_ _ft. Total System Length: Z,!,0 ft. Seepage Pit(s): number of size of each: ft.'by ft. Size of Stone to be used: '#t//r- / depth or thickness feet Bed.System Size: Alternative System: length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved — _ - - electrical-inspection agency.-- -- 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. Signa ur responsible person to ''•. it . ' ,'l'awtt••ttf �Zuta'!tt;tlnti•y ' 5[;tivta•a soul e Di. gal 011ovit':• Ap))'.ndi x t`(1 w I A-11.SUM"TION I"I I-Ijl.) ' RI�,I'/1lt/�,'!'1WMI It��tZl:3IItIa•I�]I��N'I`� : - . }�QN D it- • MIS tt'w•t . 'cur c�St►Ic� • ' t w r• t •�r 1 F`t Rtitr � ss 1 77 .ram •I.•r '� --CAM•.•/1 ROM) 7, SIONA�TURE &WOFMATIt'JN PO4 USPI UN;$WJ.4 rz"vt4 ��vw��.vyv;:r' ; :•":: Queensbury Building & Code Enforcement - Residential Final Inspection 30 I Office No.(518)761-8256 Arrive: am/ epart: am/pm Date Inspection request received: Inspector's Initials: NAME: 0,1 , C Li a-u' r U PERMIT#: LOCATION: I L) Lnt&& DATE: TYPE OF STRUCTURE: L e Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Com lete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more -C/I�G�C Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 terior privacy/trim/doors/main entrance 36 in. athroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s .ft. vents C Building No./Address visible from road //; (/LL J1 Final Electrical 0 D C b j Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker food Plain Certification, if required *Mkay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res• Final Insp. form 2.docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/ Depart:/ - m/pm Date Inspection request received: Inspector's Initials: NAME: VA t cV,_ $ 6R PERMIT#: LOCATION: Id U I Aj -i. --N , DATE: TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake G�u 3 inch Plumb Vent through roof minimum 6" i Roof Complete/Exterior Finish Com lete Guard 30 in. or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum '/2" Gypsum Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. $athroom/Kitchen watertight zP pG� � ✓��� �f;4 Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: L /������ Every level: / Every Bedroom: JVT Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches _ [,Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft. vents Building No./Address visible from road v 5 �G 1 p Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Ii Flood Plain Certification, if re •red- Okay to issue C/C or C/ [Temporary Permanent] AIL:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. /Orm 2.docLast printed 2/12/04 V Town of Queensbury Fire Marshal 742 Day Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Firepla e� /Stove ln�spection Renort Notice: New Fork State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contai d in the Installation Manual accompanying the appliance.No deviation from the manufacturer's > �J� instructions or specifications is allowed. Permit V I r_ Schedule Inspectionssn - -NTimc � ain pm anytime Inspector jP" Name I ' oja �.�� Address �1.-►� ram_. Rough In.Final Appliance Manufacturer Model# Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) 'Vertical Chase Wall Penetration Trent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Start-Off Value Combustion Air Hearth Extension if any) Mantel Height above Up opening Witness Operation Tank Placement(if LP) White—Btailding Dept. jveuow C-ust er Pink—Dire Msuslml Queensbury Building & Co Enforcement - Residential Final Inspection :. Offic o. (518)761-8256 Arrive: am/pm Depart: 3;3+ am/pm Date Ynspection request received: Insp'ector's Initials: NAME: PERMIT#: LOCATION: C DATE: TYPE OF STRUCTURE: I Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake �0 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete - — Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %Z" / Gypsum ✓ %;i Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window,in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Batter backu : Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"aeces , 1 s . ft.-150 s . ft. vents Building No./Address isib fyom.re A Final Electrical to S Site Plan /VarianceVegillWed Iv Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Oka to issue C/C or C/O Tem orar /Permanent L:\PamW\Building&CodesUnspection Fornis\Res. Final Inso. form 2.docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: anVpm Depart: am/pm Date Inspection request rece'VAd: — Inspector's Initials: , 2 NAME: �t 1 (- PERMIT#—:_-- 0 ! —,3 3 LOCATION: 1 C t.� �� DATE: TYPE OF STRUCTURE: _ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs, decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches _ Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in,(ht,)In accessible area Crawl S aces 18"x 24"access, 1 s . ft.-150 s . ft. vents Building No./Address visible from road Final Electrical Site P an /Variance required -Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Buildinp,&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: , Queensbury Building&Code Enforcement Arrive: a Depart-q am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials NAME: Ax614A""-1'5 610r PERMIT NO.: 9iG LOCATION: iL> CRU L,4 L tj INSPECT ON: `� a RECHECK: Comments and/or diagram Soil Type: Sand/Loam/Clay _.Type of Water: Municipal/Well Water Waterline separation distance Well separation distance ft. ,�✓C . C� ��L � � ���L C—� Other wells: Absorption Field: Total length Length of each trench ft. ["� Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/Pit Opening Sealed: Y/N/Partial Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as_per Plot Plan Y N CIS Location of System on Property: Front Rear Left Side Right Side Middle Fro Middle Rear S stem Use Stat s: Approved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved L:\SueHemingway\Building.Codes.Inspection.FORMS\Septic Inspection Report.doc January 23,2003 '4 Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: o �l Queensbuiy Building&Code Enforcement Arrive: am/p epart: am/pm 742 Bay Rd., Queensbuly,NY 12804 Inspector's Initials: NAME: f_ C PERMIT NO.: �� LOCATION: INSPECT ON: RECHECK: Comments and/or diagram Soil T e: and Clay Type of Water: i unicip 1/Well Water Waterline sepa ation d' tance Well separation nce ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone -Seepage Pits: Number Size: x < Stone Size: Piping Si T Building to tank G Tank to Distribution Box 0 � Distribution Box to Field/Pit Opening Sealed: Y/N/Partial Location/Separations Foundation to tank U ft. Foundation to absorption _ft. Separation aration of Pits ft. Conforms as per Plot Plan Y_N Location of System of Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: C Approved rtial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved L:\SueHemingway\Building.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 boo 169 Haviland Road, Queensbury,NY 12804 Phone-518-745-4400 Fax -518-792-8511 October 7, 2004 Job#46176 New York State Dept. of Health 77 Mohican Street Glens Falls,,NY 12801 RE: Quincy Lane Subdivision- Queensbury(T) 10 Quincy Lane(Lot# 16) Septic System Dear Sir/Ma'am: This letter is to inform you.that we inspected the completed septic system for the house at 10 . Quincy Lane(Lot#16) in the Quincy Lane Subdivision on September 29, 2004. The septic system as installed was for a four bedroom house and consisted of a 1,250 gallon septic tank and 200 lineal feet of absorption trench constructed with stone and perforated pipe. The system conforms to the requirements of the approved subdivision design drawings. Please call me if you have any questions or concerns. Sincerely, Thomas R. Center Jr., EI cc: Dave-Hatin,Town-of Queensbur�- 4 Eric Wilson, The Michaels Group Oq -393 R E i V'-D —Tovirm'OF Wool MAP REFERENCE: LOT 15 QLMGY LANE 5UBDM510N THE flGHALE5 GROUP By, VAN DU50 + 5TEVE5 DATED APRL 15. 2003 S16026'30'W LA5T REVI5M JUNE 10. 2003 249. 18' _ V 0 0 1 � C 1 a �• o Lj wr 40 •y- �. c p R t vE �4y cc h H w Cal al ) N 16 to 'a e o n $ r N = 0 C 2 Z o C4 A 0 � lA q n 246.87'• �+ Ul N16°26'301E bS cn n a LOT 17 cd 8-1 a Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/pm �rt: m/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: A-\CL eL ��Y PERMIT #: LOCATION: 1/ A i n ZA INSPECT ON: — _ I TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. PlumbingVent/Vents in Place Rough Plumbing/Nail Plates I % inch min. Drain Size Washing Machine Drain 2 inch min. /' 1 Head or Air Supply Test VCJ - S Drain and Vents 5 PSI or 10 feet above highest C�1 �- !�� �� connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper,CPVC,Pex One and Two-Family / r `1IRsul407ii/Residential Check/Commercial Check U /J 5 . - o er Vent,Attic Vent ZE- ; WC 11f Pr Duct/Hot Water Piping Insulation If required unheated spaces A4rZ-- Combustion Air Supply for Furnace Duct work sealed properl /No duet tape COMMENTS: D U LASueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: _am/ m Depart am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:� <_ NAME: 1 \1 C. PERMIT#: L/ (-f 3 �3 LOCATION: INSPECT ON: _ � TYPE OF STRUCTURE: Y I NI N/A COMMENTS Fr ing _ Jack Studs/Headers 06, C u7— Bracing/Bridging Joist hangers 1,V:5 7_�4-1— /)4 Ie- 5 7J� Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour ` Fire `112, 3, 4 hour restopping Penetration sealed 16 inch insulation in cavity min. 2Cc1 Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Q 9S 7 � �1 �� Rough Plumbing / i.� sulatCOn Ins ct�on Report 1/ Ck Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/prr� Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: �1 fC,Ei NAME: PERMIT #: LOCATION: (� INSPECT ON: -n TYPE OF STRUCT Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron,_Copper Drain/Vent/Comm. Plumb' Vent/Vents in Place ),_Ro`u*`gh Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper,CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces_ Combustion Air Supply for Furnace Duct work sealed properly I No duct tape COMMENTS: L:\SueHemingway\13uiIding.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November]7,2003 Town of Queensbury Fire Marshal 742 Day Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fire lace/5tove Inspection Re>�ort Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit# � Schedule Inspectio Time am pawn anytime Inspect Names An C�4 Address Rough In IFinal_ Appliance Mannf cturer 1*464t_6�`171 C Model# -3 re (312 yy lr -G�?�8 cp Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated - Yes No N/A comments Floor Protection Clearances to Combustibles (all sides) F'irestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension(if any) Mantel Height above Up opening Witness Operation Tank Placement(if LP) Wt dte•-Banding Dept. ----- Y e61ow Cast er Pink—Fire Marshal Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received Queensbury Building& Code Enforcement Arrive: am/ epart: an�/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. f-- NAME: PERMIT#: LOCATION: ,fj QU\ CU C_ • INSPECT ON: ff Ski d TYPE OF STRUCTURE: Y N N/A COMMENTS Framing -Jack Studs/Headers I Bracing/Bridging Joist hangers �[ Jack Posts/Main Beams �J Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. IDS �LL 1 ���� j U105 Stairwells 36 in. or more S ^ C Headroom 6 ft. 8 in. l SC v S J�✓� Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping �V_`"Penetration sealed` 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHeminsway\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request c ive q i D a 1__5 L Queensbury Building&Code Enforcement Arrive: art: n 742 Bay Road, Queensbury,NY 12804 Inspector's Initi , NAME: L ( PERMIT #: 00 �3 I LOCATION: 0 INSPECT ON: D 0, TYPE OF STRUCTURE: -5 T) Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. i Plumbing Vent/Vents in Place -Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/chan a of direction Water Supply Piping Cooper Commercial Cooper,CPVC,Pex One and Two-Family Insulation/Residential Check/ Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doe November 17,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement -Arrive: _<6 am/p Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: I _ PERMIT LOCATION: / �} v INSPECT ON: V ilk TYPE OF STRUCTURE: Y N N/A PVC: R-1,k-2,R-3,R-4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents f 5 PSI or 10 ft. above highest (,,�/l� /-ec/ E Connection for 15 minutes Water Supply Piping Z Copper Commercial Copper, CPVC,Pex One &Two Family Insulation/Residential Check/Commercial Check Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: L:\Suel-lemingway\Building.Codes.In spection,FORM S\Rough Plumbing Insulation Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection re est ece' e o Queensbury Building&Code Enforcement Arrive: p art: a sp 742 Bay Road, Queensbury,NY 12804 Inector's Initia s NAME: J /, PERMIT#: c� LOCATION: LZ-b-)G' INSPECT ON-7i, 3 0 TYPE OF STRUCTURE: y N: lv/a COMMENTS Framing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 `/2(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center ce and now shield 24 inches fro 1 Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28;2003 Foundation Inspection Report Office No. (51-8)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Depart: 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: D®. LOCATION: O ald%uf, %VYL, INSPECT ON: `]/A 0 J • :Q(? TYPE OF STRUCTURL: (j Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place F undation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab ackfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 1 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection reque t received: Queensbury Building&.Code Enforcement Arrive: am/p Depart. _ am/pm 742 Bay Rd.; Queensbury,NY 12804 Inspector's Initials: NAME: _ iC� —C� PERMIT#: C;) I J LOCATION: _� \ INSPECT ON: TYPF,OF STRUCTURE: S43p Comments ootings Piers Monolithic Slab Reinforcement in Place/ The contractor is responsible Y+oi providing protection from freezin for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation./Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHcmingway\BuiIding.Codes.InspectionTURMS\foundation Inspection Report.doc January 28,2003 0 Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lc Data filename:F:\SHARE\Design\Energy Calc\Quincy Lane\10 Quincy.rck TITLE:QL542 Madison COUNTY:Warren STATE:New York HDD:7635 JUN 0 j 2004 CONSTRUCTION TYPE:Detached 1 or 2 Family _ HEATING TYPE:Non-Electric DATE:05/26/04 DATE OF PLANS:May 26,2004 PROJECT INFORMATION: 10 Quincy Lane Queensbury,NY COMPANY INFORMATION: r t � The Michaels Group 10 Blacksmith Dr. Malta N.Y. 12020 NOTES: Pella Proline Series Windows �aq All? COMPLIANCE: COMPLIANCE:Passes Maximum UA=457 Your Home UA=399 12.7%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Raised or Energy Truss 1252 30.0 0.0 40 1st Floor walls:Wood Frame, 16"o.c. 1602 19.0 0.0 83 2x Family(AP):Wood Frame,Double Pane with Low-E 28 0.340 10 lx Family(AV):Wood Frame,Double Pane with Low-E 23 0.340 8 Brkfst#7:Glass 40 0.350 14 Utility#20:Solid 19 0.240 5 Ix Study(BC):Wood Frame,Double Pane with Low-E 31 0.340 11 Entry#1:Solid 21 0.350 7 1x Living(BC):Wood Frame,Double Pane with Low-E 31 0.340 11 lx Dining(BC):Wood Frame,Double Pane with Low-E 31 0.340 11 2nd Floor walls:Wood Frame, 16"o.c. 1307 19.0 0.0 70 2x Mbr(BB):Wood Frame,Double Pane with Low-E 31 0.340 11 lx Mbath(DL):Wood Frame,Double Pane with Low-E 16 0.340 5 lx Bath(N):Wood Frame,Double Pane with Low-E 6 0.340 2 lx Bed#2(BC):Wood Frame,Double Pane with Low-E 31 0.340 11 lx Foyer(AE):Wood Frame,Double Pane with Low-E 14 0.340 5 lx Bed#3(BC):Wood Frame,Double Pane with Low-E 31 0.340 11 lx Bed#4(AB):Wood Frame,Double Pane with Low-E 16 0.340 5 Basement Wall 1:Solid Concrete or Masonry 1179 0.0 11.0 76 Wall height:7.5' Depth below grade:6.5' Insulation depth:6.0' Bsmnt windows:Wood Frame,Double Pane with Low-E 5 0.560 3 Furnace 1:Forced Hot Air,80 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are a esti g that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in comp l an with e. Builder/Designer Date 2 ¢ REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lc DATE:05/26/04 TITLE:QL542 Madison Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. Above-Grade Walls: [ ] 1. 1st Floor walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 2. 2nd Floor walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 1:Solid Concrete or Masonry,7.5' ht/6.5' bg/6.0' insul, R-11.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. Windows: [ ] 1. 2x Family(AP):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 2. lx Family(AV):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 3. lx Study(BC):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 4. lx Living(BC):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 5. lx Dining(BC):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 6. 2x Mbr(BB):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 7. lx Mbath(DL):Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No A Comments: y [ ] 8. lx Bath(N):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes - Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 9. lx Bed#2(BC):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 10. lx Foyer(AE):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 11. lx Bed#3 (BC):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 12. lx Bed#4(AB):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 13. Bsmnt windows:Wood Frame,Double Pane with Low-E,U-factor:0.560 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: Doors: [ ] 1. Brkfst#7: Glass,U-factor:0.350 Comments: [ ] 2. Utility#20:Solid,U-factor:0.240 Comments: [ ] 3. Entry#1: Solid,U-factor:0.350 Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,80 AFUE or higher Make and Model Number Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. w Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [ ] All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State ,the Residential Code of New York State or the New York City Building Code ,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 must be insulated to the levels in Table 2. Table l: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts l"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) MAP REFERENCE: QUINCY LANE SUBDIVISION THE MICHALES GROUP BY: VAN DUSEN & STEVES DATED: APRIL 15, 2003 �rvly�cr LAST REVISED: JUNE 10, 2003 psx LOT 15 S16026'30"W 249. 18' a; w W LOT 16 co1.00 acres ! N es.z 43,611 sq.ft. r0 to T o I maw O 0 LL 5 cp M! y EnpS ti 0 OO r CV) LLI)_ r l ASPHALT DRIVE Cr N N 246.87' Lj UTILITIES N16026'30"E 1 HEREBY CERTIFY THAT THIS MAP WAS PREPARED FROM AN ACTUAL FIELD SURVEY. THIS CERTIFICATION SHALL RUN ONLY TO THE PERSONS FOR WHOM THE SURVEY WAS PREPARED, AND ON THEIR BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON. ' Qu( N G CERTIFICATIONS ARE NOT TRANSFERABLE TO ADDITIONAL INSTITUTIONS OR SUBSEQUENT OWNERS. CERTIFIED TO: BRIAN D. RUMRILL LOT 17 BANKNORTH, N.A., IT'S SUCCESSORS AND/OR ASSIGNS • . CHICAGO TITLE INSURANCE COMPANY k . CERTIFIED BY: b -- MATTHEW C. SIEVES, ILLS NYS 50135 DATED: OCTOBER 8, 2004 a ID S (r (Date+ ctober 0 4 'UNAUTHORIZED ALTERATION OR ADDITON TO A SURVEY Ma of a Survey inade for Scale 1'=30� YAP BEARING A LICENSED LAND SURVEYORS SEAL IS A Map S y VIOLATION OF SECTION 7209,SUB-DIVISION 2,OF THE NEW YORK STATE EDUCATION LAW.' 'ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY MARKED WTH AN ORIGINAL OF THE LAND SURVEYORS SEAL SHALL BE CONSIDERED TO BE VAUD TRUE COPIES.' '. t e v e s IS SURVEY WAS PREPARED HEREON DANCE THAT Brian D . Rumrill S 1 THIS SURVEY CO O PREPARED O LAND URE OR THE E%ISTING CODE OF PRACTICE FOR LAND SURVEYORS ADOPTED L a r� d Surveyors LA THE NEWRVE PORK STATE ASSOCIATION OF SHALL RUN lAtJO SURVEYORS.SAID CERTIFICATIONS SHAD.RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED,AND ON HIS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL %IM7 1 OF 1 AGENCY AM LENDING INSn7uTION USTEU HEREON,AND Town of Queensbury, Warren County, New York 169 Haviland Road Queensbury, New York 12804 TO THE ASSIGNEES GF THE LENDING WSTITUnCN. RUMRILL (518) 792-8474 New York Lic. No. 50135 NO. DATE DESCRIPT70N DWG. NO. 02333-16