Loading...
2004-415 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY PennitNumber. P20040415 Date Issued: Tuesday, April 24, 2007 This is to certify that work requested to be done as shown by Permit Number P20040415 has been completed. Tax Map Number. 523400-308-006-0001-004-000-0000 Location: 39 BURCH Rd Owner. JAMES VAN DORAN Applicant: JAMES VAN DORAN This structure maybe occupied as a: Residential Addition By order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the µ property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforvement Planning Board or Zoning Board of Appeals. T TOWN OF QUEENSBURY LIJ 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040415 Application Number: A20040415 Tax Map No: 523400-308-006-0001-004-000-0000 Permission is hereby granted to: JAWS VAN LORAN For property located at: 39 BURCH Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JAN ES VAN DORAN BRENDA GRANGER Residential Addition $7,000.00 39 BURCH Rd Total Value $7,000.00 QUEENSBURY, NY 12804 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2004-415 476 SQ FT RESIDENTIAL ADDITION $75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, June 29, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at#tc-- 'own oft eensb , Tuesday, June 29, 2004 s` SIGNED6BY Y ' � ,d for the Town of Queensbury. Director of Building&Code Enforcement Building Permit Application Town of Queensbury—Dept of Community Development,742 Bay Road,Quie nsbury,NY (5l8)761.8256 A permit must be obtained before begbming construction. Permit File No. U —` No inspection will be mado until applicant has received a Fee paid $ valid Vuilding permit. All applicants' spaces on this Rec.Fee Paid application t=tbe completed and must appear on the Reviewed By. applidation form. Applicant: �' 'ems Owner: G- Address- ddress- Phone#O l =. Phone# Property Location: Lot Number: f-0 / House Number3,�,_ Subdivision Name: Tax Map Number.,�7a k©6 6_0 6o�VleLqo o New Building: residence i commercial . 'Estimated Market Value of Construction. $ 761:�Ld-a4 Addition: residence/ commeraial an Addition,w will use of new addition be? 0 Alteration: residence/ commercial /r- G No chop to exterior size: residence!com'1 m Other wbrk(d"Cdbe } Check Occupancylnformation 1' Floor 2° Floor Other floor Total B®low sq.it. sq.3't.. sq.ft. Square Feet ' Single Waily dwellin o Two 2M&dwelling o Townhouse o MuldfaraUy dwelling #of units o Offices o Mercantile o Maaufaotudzq o ?hnA 0 1 oar detached pme - 0 2 oar detached o I I I TOWN GFUEP SBURY 0 3 Cox detached garage �U!!_U9ia1C 1i 1'? �UUte_ 0 1 oar attached Pmge 0 2 oar afched I=gt . a 3 car attached Smse 0 Storage building- commercial o Storage building- residential o O er " r r What is the proposed height of the structaro Y feet —inches Will any second-band or ungraded lumber be used? If so,for what? Type of Heating System: electric/ oil as a /forced hot a' / baseboard/other: „ Number of Firemlaces to be installed Number of Foodst&l to be installed List below the person(s)responsible for supervision of work as regards to building codes: N e Address Phone Numb or Builder Plumber Mason Electrician DeolgattQn: pleaso sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,area true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified cr noted,and that such work is authorized by the owner. Further,it is understood tbat Ilwe shall submit,prior to a Cerecate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an pis Built Sarvey by a licensed surveyor.,drawn to scale,showing actual location of all new construction. Signature: � ✓✓� u� l�M � ` Mer owner's agent,architect,contractor ENERGY CODE COMPLIANCE APPLICATION TOWN OF QUEENSBURY, WARREN COUNTY 9000 HEATING DEGREE DAYS Compliance Methods:Part 5 -Acceptable Practice Method—1&2 Family Dwellings(only) Part 6*-TMenmal Rating—Component trade Offs 1&2 Family Dwelling; Multi-Family Dwellings(3 Stories or less) Part 4*-Design by Component Performance,Commercial Buildings-Hi Rise Residential *Requires submission of worksheets AP LICANT/'�)NAW, PROPERTY LO/CA N: PART 5 METHOD OF.COMPLIANCE BY ACCEPTABLE PRACTICE: 1. Gross Floor Area- S square feet 2. Type of heat-_J Electric . Oil Gas Other 3. Is building mechanically cooled? yes_,�k _No 4; Percentage of area of windows and doors Over 17% Under 17% 5. R VALUES FOR INSULATION GIVEN BEL.OW MUST CORRESPOND TO R VALUES AS . SHOWN ON PLANS SUBMITTED: a: Roof R--f C) b. Exterior walls R c: Glazed areas R d. Exterior doors R e. Floors over unheated spares R 1 f. Edge of slab on grade(heated building) R .r g. Basement/cellar walls(above grade) R c h. Basementicellar walls(below grade) R ZLI�te i. Heating/cooling-ducts-piping in unheated.space , R_ _ 6. Service(domestic.)hot water heating device Conforms to minimum efficiency per code_�( Yes No TEMPERATURE CONTROL MAXIMUM SETTING 140—WILL NOT BE EXEEDED .Applicant SipjrJ41re . Dat Phone Number INSPECTOR'S REMARKS: Queensbury Building & Code Enforcement - Residential Final Inspection . OfficeWo.(518)761-8256 Arrive: �, a e am/ Date Inspection request received: Inspector's Initia " z. - NAME: IT#: LOCATION: 1° ATE: 4—Z —0-7 OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft. vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/a hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Wicker Site Plan /Variance required / Flood Plain Certification,if required / Okay to issue C/C or C/® [Teinpor /Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form—revised-1 00405.doc Town of,Qj*nsbury Fire Marshal 742 Bay Road Queensliury,NY 12804 761-8105/761-8206 fax 745-4437 Factory Built Wood Burning Fireplace/Stove Inspection Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions r s ifications is allowed. Permit# _ Schedule Inspection ime C m m anytime Inspector �5 'vt, Name ( ��( Q Address Bough In Final Appliance Manufacturer Model# (J'l✓ ( C./ Masonry Chimney _. Factory Built Chimney Flue Si. /rDouble Wall Triple Wall Insulated Yes No N/A Comments Floor Protection IV Clearances to Combustibles(all sides) ,i A Safety Strip Installation-(fireplaces only) Firestop(s) vertical Chase Wall Penetration Chimney Clearances to Combustibles Chimney Termination I ` 3 feet above roof penetration;2 feet above L- any combustible construction within 10 feet Combustion Air Hearth Extension Mantel(height above f/p opening) .Fireplace Doors/Screen(required) White—M&Ug Dept. YOU0 —Cus mer `+ —n,,m Marshal Queensbury Building & Code Enforcement - Res'. dh ' inal Inspection Office No. (518)761-8256 Arrive: pm , De art: Date Inspection request received: Inspector's Initia NAME: �� E IT#: LOCATION: �?L 5j�k t�BC B D P&) ATE: CRT TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more(a)stairs, decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in, or more Exterior Finish Complete �� Interior/Exterior Railings 34 in.to 38 in. ►�� Platform at all exterior doors Interior Handrails stairs 2 or more risers '2 Enclosed Stairs Sheetrock Underside minimum %2" Gypsum II Grade away from foundation 6 in.with 10 fit. Handrail Termination at Newell Post or Wall i 6 inch clearance to sill plate t/ Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area —7- 1 t t 1 Furnace/Hot Water Heater operating Low water shut-off boiler4fwl Relief Valves installed/Heat Trap/Water Temp110 ���l 1 Interior privacy/trim/doors/main entrance 36 in. i1 Bathroom/Kitchen watertight Safety Iazin /Window in stairwells safety glazing �� Interior Smoke Detectors: 11 AeT \\ �7 Every level: / Every Bedroom: / �-�\�jCT 1 ' Outside every bedroom area: Inter Connected: Batter backup: Carbon Monoxide Detector Bathroom Fans, if no window F Plumbing fixtures C*�_—��� Foundation insulation '�, C���._ fi Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade �� � Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/4 hour fire door/door closer Duct work Sealed properlyJ Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in,(ht,)In accessible area ,�� y, �� tA ky- Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents Building No.No./Address visible from road / Final Electrical U Site Plan /Variance required Final Survey Plot Plan 1 As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res. Final Insv. form 2.docLast printed 2/12/04 cv Rough Plumbing / Insulation .Inspection Report Office No. (518) 761-8256 Date Inspection reques i Queensbury Building&Code Enforcement Arrive: 'a p part: am/Lm 742 Bay Road, Queensbury,NY 12804 Inspector's Init' r NAME: PERMIT #: O Q ' /IS LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2, R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. Plumbkg Vent/Vents in Place h Plumbing/Nail Plates 1 % inch min..Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Z CqVer, CPVC,Pex One and Two-Famil sulation/Residential Check/Commercial Check " Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: .f L:\SueHemingway\Building.Codes.lnspection.FORMS\Rough Plumbing fiisulatiJ Rep mdoc November 17,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins ection reque ceived: � Queensbury Building&Code Enforcement Arrive p pa : rya pm 742 Bay Road, Queensbury, NY 12804 Inspector's Imtl NAME: PERMIT#: LOCATION: INSPECT ON: gPool - 4"®d r TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly c c 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate �� 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses kc _ Anchor Bolts less 6 ft. or le on center lee and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour ✓ _1 Firestopping Penetration sealed 19 16 inch insulation in cavity min. Garage Fire Separation VN- House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X c Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHernin.-way\Building.Codes.Inspecti on.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/ Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: ltlol, PERMIT — #: LOCATION: INSPECT ON: V TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Iee and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed ; 16 inch insulation in cavity min. lAf 1 Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspecti n request received: Queensbury Building& Code Enforcement Arrive: II1 am/p epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: h PERMIT#: LOCATION: INSPECT ON. /1 G TYPE OF STRUCTURE: Y N N/A Framing COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Ins e tion request received: Queensbury Building& Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: _ NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS mg Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASuel-iemingway\Building.Codes.Inspection.FORNISTraming Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (51-8) 761-8256 Date Ins ecth�r , e e e' 1) 0 b Iwo am Queensbury Building&Code Enforcement Arrive. _ a m Dep rt: 742 Bay Rd., Queensbury,NY 12804 Inspector's iti NAME: sq- , VL RMIT#: 15 LOCATION: INSPECT ON: 0 ' o'co at. TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place r Foundation Dampproofing b undation/Waterproofing � �H Waterproofing p Footing Drain Daylight or Sump Footing Drain Stone: S 12 inch width 6 inches above footing t l Y 6'mil poly for wet areas under slab ackfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 G Foundation Inspection Report 'T � Office No. (518) 761-8256 Date Inspection re es rec iv d: Queersbury Building&Code Enforcement Arrive: 1/p Depart: ,oval in 742 Bay Rd., Queensbury, NY 12804 Inspector's Initi s: NAME: IZMIT#: LOCATION: c _ TSPECT ON: �_ TYPE. OF STRUCTURE: Comments Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providin rotection from freezing for 4 . ours following the placement of e concrete. aterials for this pu.Tpse on site. oundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASucHcmingway\Building.Codes.Inspection.rORMSToundation Inspection Report.doc January 28.2003 Foundation Inspection Report Office No. (518) 761-82.56 Date Inspection r s rec e Queensbury Building&.Code Enforcement Arrive: 0" Depart: 742 Bay Rd., Queensbury,NY- 12804 Inspector's Initi () q, — NAME: �� Yv` C� jy , IT#: LOCATION: �.0 - 0 INSPECT ON: TYPE OF STRUCTURE: 1 Comments Y N N/A "footings Piers - Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this pu.T2se on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under SIab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. [,:\Suellicmingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 t E {, ✓J � p nvC� , Tr 4 � _ =o TOWN OF QUEENSBURY BUILDING DEPARTMENT �_ C9 Based on odr limited examination, T comppliance with our comments shall c']r-not be construed as indicating the plans and specifications are in full compliance with the Building Codes t of idew York State. f.� 7� KRAI PAPS 91SULAT10N MUST y, - COVERE BY NON-COMBUSTIBLE BARRIER F, r N f " Ems.!,7 fL I1 BUILDING NOTICE REVIEWED BY , FOAM INSULATION MIXT BE COVERED DATEC BY A 15 MINUTE THERMAL BARRIER {I C2 x" 0001, 2' �>Z Com Ise- i 1 f - w� • 1 . CzO ' lam F IV ED RB eF I... ka 01 0 Y\ elt, V Cy gr Ga \C5 IR WINDOW SCHEDULE Job Site/Address: -39 Gi�BL" 9-c> ►D Date: Z�—�,� Owner: Application No. -tAv5 Window Window Window Unit or Rough Rough SQ.FT. SQ.FT SQ.FT. Clear Clear Special Hardware Number or Manufaturor Model/Type Stock Openin Opening GlassNis Egress/Cle Opening Opening or Instructions Letter on Name Numbe g Height ible Vent ar Width In Height Plan Call Width Light Opening Inches In Inches Size (' n o L L a Z s s loop Example Entry A Andersen Narroline 3062 3' 2 6'5 '/2 15.30 8.36 6.01 34 2415/36" Tempered Double 1/3" 11/16 Glazing Hun CADocuments and Settings\Sue\Local Settings\Temp\Window Schedule.doc i� P t er U� J REScheck Compliance Certificate Checked By ate 2000 IECC RES checkSoftware Version 3.6 Release 1 Data filename:C:\Program Files\Check\REScheck\Van Dorin Addition.rck PROJECT TITLE:Van Dorin CITY:Glens Falls STATE:New York HDD: 7635 CONSTRUCTION TYPE: Single Family WINDOW/WALL RATIO:0.08 DATE: 06/29/04 DATE OF PLANS: 6/25/2004 PROJECT DESCRIPTION: Residential Addition(Family Room) 39 Burch Road Queensbury,NY 12804 DESIGNER/CONTRACTOR: James Van Dorin COMPLIANCE:Passes Maximum UA=107 Your Home UA=102 4.7%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 576 30.0 0.0 20 Wall 1:Wood Frame, 16" o.c. 576 19.0 0.0 31 Window 1:Vinyl Frame:Double Pane with Low-E 35 0.490 17 Window 2:Vinyl Frame:Double Pane with Low-E 12 0.350 4 Door 1: Solid 20 0.140 3 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 576 19.0 0.0 27 Furnace 1:Forced Hot Air,78 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.6 Release 1 (formerly MECchecl and to comply with the mandatory requirements listed in the RES checkInspection Checklist. a �,Builder/Designer ►% i REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.6 Release 1 DATE: 06/29/04 PROJECT TITLE:Van Dorin Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Windows: [ ] 1. Window 1:Vinyl Frame:Double Pane with Low-E,U-factor: 0.490 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 2. Window 2:Vinyl Frame:Double Pane with Low-E,U-factor: 0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: Doors: [ ] 1. Door 1: Solid,U-factor: 0.140 Comments: Floors: [ ] 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-19.0 cavity insulation Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,78 AFUE or higher Make and Model Number Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Y 1 Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), mastic-plus-embedded-fabric,or tapes. Tapes and mastics must berated UL 181A or UL 181B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g. (500 Pa). [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 `17 or chilled fluids below 55 T must be insulated to the levels in Table 2. 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature FZ Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVACPipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes wing System Types Range F1 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) 30/ � PD TO ROAD r y -C