Loading...
2004-424 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number. P20040424 Date Issued: Wednesday, September 29, 2004 This is to certify that work requested to be done as shown by Permit Number P20040424 has been completed. Tax Map Number. 523400-308-010-0002-064-000-0000 Location: 14 ROSE Ln Owner. NICHOLAS LOSITO JR Applicant: NICHOLAS LOSITO JR This structure maybe occupied as a: By Order of Town Board Deck TOWN OF QUEENSBURY Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040424 Application Number: A20040424 Tax Map No: 523400-308-010-0002-064-000-0000 Permission is hereby granted to: NTC;HOLAS LOSTTO JR For property located at: 14 ROSE Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: NICHOLAS LOSITO JR 14 ROSE Ln Deck $3,000.00 Total Value $3,000.00 QUEENSBURY, NY 12804-0000 Contractor or Builder's Name /Address Electrical Inspection Agency LEE HORNTNG NY 12804-0000 Plans&Specifications 2004-424 468 SQ FT DECK $46.80 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday, June 21, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To o eensb n y, June 21, 2004 SIGNED BY for the Town of Queensbury. Director of Building&Code nforcement Porch, Deck, Dock, or Boathouse Permit Application Town of Queensbury—Dept of Community Development,742 Bay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. No Permit File No. ' inspection will be made until applicant has received a valid Fee Paid $ building permit. All applicants'spaces on this application must be Reviewed By: completed and must appear on the application form. PP �/�Gha l4 S ��S�,�aJ�1�/1 Owner: /a )4 S k 6 fir. Applicant: Address: Address: /1�' Afl-. Phone#(01 )142- - Phone#(5-79-)712- Email Address: Email Address: P.�� JUIV 0 9 2004 Person Responsible.for Supervision of Work as Regards to Building Cod?b _ BUILDING�MjV8,Lft4,,,U Name Lee or r Address: Gfen� � ��s � Property Location: Lpt Numb / House Number 7a, �a, Subdivision Name: -)`a G Tax Map.Number:3�5�. id_ Estimated Market Value of Construction: $ ,�000 ❑ Porch Deck ❑ Dock p7�0-P x 18-�4 ��-- ❑ Boathouse ❑ Other work(descnbe �zt = 30 Size of structure to be buiiF4_ 8 square feet 5 ^ aG Submit along with this application: 1. 1 Two plot plans drawn to scale,preferably using a survey map. Indicate proposed structure showing setback dimensions from all property.lines. Show-location of water supply and location and configuration of septic disposal area. 2. Two sets-of-structural-drawings. Indicate size of posts or studs,-floor-joists, decking or flooring material to be used. Show how the porch or deck will be fastened'to the building. If a roof will be constructed,indicate the size of posts or studs,roof rafter spacing and span. Indicate type of roof: sloped,flat, shed,or other. Indicate the type of material being used for the roof. Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises anlc tliat all-provisions of the Building Code,the Zoning-Ordinance-and-all-other-laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Applicant's signature: Date: LASueHemingway\Building.Permit.FORMS\Poreh.Porch.Permit.doc 8/13/02 revised per DH sV, Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/p 1�e - - art: tc a m P Date Inspection request received: 7 Inspector's Initials: 1 NAME: 0/ —4 PERMIT#: �/�- LOCATION: DATE: - TYPE OF STRUCTURE: (R Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete E Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minitnum %2" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss, draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl S aces 18"x 24"access, 1 s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent] L:\PamW\Building&Codes\Inspection FormslRes, Final Insp. form 2,docLast printed 2/12/04 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/pm Depart: -3 am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: i; NAME: PERMIT#: LOCATION: INSPECT ON: L,E: I Q co`� TYPE OF STRUCTUR f t Y N lv/a COMMENTS raming ' s Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.,or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in.'(W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\I3uilding.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 �� c✓�`s L Foundation Inspection Report _ 7 Office No. (518) 761-8256 Date Inspection requ G Queensbury Building&Code Enforcement Arrive: VHD an ' epart: ° a pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials e v. NAME: � r� )-v S i Y. ZMIT#: �� --l Ll LOCATION: _ I� _ INSPECT ON: _ TYPE OF STRUCTURE: ^ Comments deck - N/A Fo 'ngs _ Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. _ Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. U\SueHcmingway\Building.Codes.Inspection.PORMSToundation Inspection Report.doe January 28,2003 L4-Lt,;)-(4 D —i co iCf�®PY m�� �' 4O��FILE m 9: JUN 0 9 2004 0 rowN of .A W>_ BUILDING Ay OD RY C o E m W. QIlj ILDI BU REVIEWED F DATE G DEPAR�M NY `� � RY gU1tDIN ination, . t QUEo r limited a ments shall lianceourco the . z Based m. com ed as �ndicat�ng i not be cons iflcabons are Cod s plans and swi the 6uddm9 f oaf New Yoh S � 1 � t - ti" � Z �"mot 6�p0C I r m m N',m .� - -4mCD , � _Ili CO ED _ ry ` r C U3 rn33DC G m. O - O V\Ew L05\-�ODeckQA\q8 GvS�O�EP Gv � p512-1tp DR�E <j tad # ' 0p \VAG. goo 0\E' 2-sr o\ ! BEAMI LAYOUT FOR LEVEL 3 CURTIS LUMBER CO. INC. CUSTOMER -- LOSITO 460 BIG BAY RD DATE 05/27/04 REF Deck04148 OUEENSBURY, N.Y. 518-792-8501 1, 7„ 1' 3 1/4" 1' 4" C 1, 4„ D 1' 4" E 1' 4„ 1' 4„ G ` 1' 4„ H 1' 4" I J 1' 4" 1' 4" K {— Y 4" L �- 1' 9 3/4' BEAM BEAM POST POST LABEL LENGTH COUNT SPACING A 10 1/2" 0 B 10 1/2" 0 C 10 1/2" 0 D 10 1/2" 0 E 10 1/2' 0 F 10 1/2' 0 G 10 1/2" 0 H 10 1/2" 0 1 10 1/2" 0 J 10 1/2" 0 K 10 1/2" 0 L 10 1/2" 0 Post spacing is measured center-to-center. Depth of concrete footers --- 48 inches. BEAM LAYOUT FOR `LEVEL 2 CURTIS LUMBER CO. INC. CUSTOMER -- LOSITO 460 BIG BAY RD DATE 05%27/04 REF ,Deck04148 L1�C� �f- UEENSBURY; N.Y. 4,t.Ab4j 8-792-8601 a _A 9' 1/2, I FT 1' 11 1/2" ;7 BEAM BEAM POST POST LABEL LENGTH COUNT SPACING A 8' 1 1/2" 2 7' 10" B 24' 10 1/2" 4 8' .2 114". Post spacing is measured_ center-to-center. Depth of concre�foot�ers ---- 48 inches. I BEAM LAYOUT FOR LEVEL I CURTIS LUMBER CO: INC. CUSTOMER -- LOSITO 460 BIG BAY RD DATE 05/27/04 REF Deck04148 CUEENSBURY, N.Y. 518-78 2-8601 �. �0.4 _ .^'�i F�_���� t t�`k;�'F tF i iys i,ice. ;� i��:. � d_J'4v":•�Y....x--,A� •-i7 wx- d�-:...... Z4 Z. Y 3 �3 sri x:, t may' V Y � t C 4r ?� �'�,5 u,eS�:A�:{.i���ct'' "4��': - �r �,.w �';-�is�5�'."c'3 xs::,�.^���S.�r-��i.'y+:u..,�'"�'.x7•��.'�a,Y�,-, -��rr. ��.`�:%ax, ,f<,nri��+ s.Nsz,t„s t .�K azf NAz, 2 - Al A a � rah - tA. z z a � CU BEAM BEAM POST POST LABEL LENGTH COUNT SPACING A 5' 5 114" 2 5' 1 3/4" Post spacing is measured center-to-center. Depth of concrete footers --- 48 inches. . BILL OF -MATERIALS CUSTOMER: LOSITO E: 05/27/04 DESIGN: DECK04148 REF: _ _._ESMAN # UNAVAILABLE COMPONENTS 1X10S IN PT PINE NOT AVAILABLE FOR FASCIA (1 26 FOOT LENGTHS) 1X10S IN PT PINE NOT AVAILABLE FOR FASCIA (1 18 FOOT LENGTHS) 1X10S IN .PT PINE NOT AVAILABLE FOR FASCIA (1 7 FOOT LENGTHS) 1X10S IN PT PINE NOT AVAILABLE FOR FASCIA (2 25 FOOT LENGTHS) 1X10S IN PT PINE NOT AVAILABLE FOR FASCIA (2 17 FOOT LENGTHS) 1X10S IN PT PINE NOT AVAILABLE FOR FASCIA (1 12 FOOT LENGTHS) 1X10S IN PT PINE NOT AVAILABLE FOR FASCIA (2 8 FOOT LENGTHS) 1X10S IN PT PINE NOT AVAILABLE FOR FASCIA (1 6 FOOT LENGTHS) ------=-------------------------------------------------------------------- SUMMARY ----------------------=---------------------------------------------------- T.TTwBER MATERIALS $ 1640 . 76 ER MATERIALS $ 402 . 04 .L�lAL $ 2042 . 80 PRICE VALID TODAY ONLY. -----------------=----------=----------------------------------------------- --------------------------------------------------------------------------- WOOD TYPES USED IN DECK --------------------------------------------------------------------------- DECK PLANKS PRESSURE—TREATED PINE JOISTS PRESSURE—TREATED PINE FASCIA PRESSURE—TREATED PINE LEDGERS PRESSURE—TREATED PINE BEAMS PRESSURE—TREATED PINE GROUND POSTS PRESSURE—TREATED PINE RAIL POSTS PRESSURE—TREATED PINE RAIL CAPS PRESSURE—TREATED PINE RAIL SPINDLES PRESSURE—TREATED PINE 'sR RAIL MEMBERS PRESSURE—TREATED .PINE BILL OF MATERIALS --- LUMBER CUSTOMER: LOSITO E: 05/27/04 DESIGN: DECK04148 REF: - E SMAN # --------------------------------------------------------------------------- COMPONENT SKU QUANTITY DESCRIPTION WOOD TYPE --------------------------------------,,-i--- ------------------------------ DECKING 56,-0T .4-7'EA 5/4X6 10" PT PINE 5/4 X 6" 8 ' PT PINE' DECKING 5612T 22 EA 5/4X6 12' PT PINE -DECKING 5616T , EA 5/4X6 16' PT PINE - -_ IL CA 2612T 1 EA 2X6 12' PT PINE HORIZONTAL RAILS 2416T 1 EA 2X4 16' PT PINE VERTICAL RAILS 224TB 22 EA 2X2 4 ' SQ BAL PT PINE ,,RAIL POST 4412T l EA 4X4X12 PT PINE BEAMS �- 2108T EA 2X10 8 ' PT PINE JOISTS 2810T 14 EA 2X8 10' PT PINE JOISTS 2812T 6 EA 2X8 12' PT PINE JOISTS 288T 15 EA 2X8 8 ' PT PINE RIM BOARD 288T 10 EA 2X8 8 ' PT PINE RIM BOARD 2812T 1 EA 2X8 12 ' PT PINE RIM BOARD 2810T 7 EA 2X8 10' PT PINE RIM BOARD 2816T 3 EA 2X8 16' PT PINE rRnrJND POSTS 4412T 1 EA 4X4X12 PT PINE TND POSTS 4410T 1 EA 4X4X10 PT PINE ------------------------------------------------------------------------ r ct�1 s r C MAP REFERENCE: MAP ENTITLED "MAP OF A PROPOSED SUBDIVISION MADE FOR HERALD SQUARE SUBDIVISION LAYOUT AND UTILITY PLAN", DATED 5/29/96 LAST REVISED 10/2/96, PREPARED BY VANDUSEN do STEVES, LS. FILED IN THE WARREN COUNTY CLERK"S OFFICE ON DEC. 31, 1996 IN PLAT CABINET B, SLIDE 85, bw LOT 136 MAP #185. Q T � — REc �y EI VE p cl ` s1'6 CNN n 9 200 OWjy N BU/tpOF�pNSBORY •'00. w,�r O _ I HEREBY CERTIFY TO: 1 KURTIS C. & AMY L. GLENN 2� HOME FUNDING, INC., IT'S SUCCESSORS AND/OR ASSIGNS. 3) FIDELITY NATIONAL TITLE INSURANCE COMPANY OF NEW YbRK f/ THAT THIS MAP WAS PREPARED FROM AN ACTUAL FIELD F f SURVEY. THIS SURVEY AND THE CERTIFICATIONS HEREON SHALL BE �1t / VALID ONLY TO THE PARTY OR PARTIES HEREON NAMED AND Q _ ARE NOT TRANSFERABLE TO ADDITIONAL INSTITUTIONS OR LOT 137 �j� LOT 134 SUBSEQUENT OWNERS, OTHER THAN AS MAY BE OR 23,335 SQ.FT. Ooj' EXPRESSLY STATED HEREON. G` DAVID J.a.T.v. O DATE: NOVEMBER 24, 1998 O 198 LOT 10 MAP OF A SURVEY OF LOT 137 HERALD SQUARE MADE FOR - - LOT 138 z5,1 KUR TIS C. AMY L. GLENN TOWN OF QUEENSBURY, COUNTY OF WARREN, STATE OF NEW YORK "UNAUTHORIZED ALTERATION OR .ADDITION TO A SURVEY DAVID J. BOLSTER MAP BEARING A LICENSED LAND SURVEYORS SEAL IS A LICENSED LAND SURVEYOR VIOLATION OF SECTION 7209, SUB—DIVISION 2, OF THE 342 MAIN STREET, HUDSON FALLS, NEW YORK 12839 NEW YORK STATE EDUCATION LAW' "ONLY COPIES FROM THE ORIGINAL OF THIS SURVEY DATE: NOVEMBER 24. 1998 SCALE: 1" = 30' N.Y.S. UC. NO. 49534 MARKED WITH AN ORIGINAL OF THE LAND SURVEYORS SEAL SHALL BE CONSIDERED TO 8E VALID TRUE COPIES." DWG. NO. 98157 B �j