Signed Inspection Report (Wed Mar 3, 2021 at 225 PM)INSPECTION WORKSHEET (BINS-008646-2021)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:CC-0571-2020 Case Module:Permit
Inspection Date:Wed Mar 3, 2021 Inspection Status:Partial Pass
Inspector:O'Brien, John Inspection Type:Building Insulation
Job Address:Parcel Number:728 QUAKER RD
Queensbury, NY, 12804
303.15-1-10
Contact Type Company Name Name
Contractor Hilltop Construction
Applicant Hilltop Construction
Granted Permission R & P Quaker II Realty, LLC
Engineer Daniel W. Ryan, PE Ryan, Daniel
Primary Owner R & P Quaker II Realty, LLC
Checklist Item Status
Mar 03, 2021 Page (1)
INSPECTION WORKSHEET (BINS-008646-2021)
Checklist Item Status
Building Inspector Notes Failed
2/3/21 Building Insulation - Roof Only!
- Ceiling Partial Approval (R25 + R13 on south half of building).
2/4/21 Building Insulation Partial Approval
- Ceiling Partial Approval (R25+R13 on east half of north side.
Note: Inspecting balance between 1:00 - 2:00.
2/4/21 Building Insulation Partial Approval
- Balance of ceiling insulation approved R25+R13
2/5/21 Building Insulation Partial Approval
- End Walls at overhead doors R27 partial approval. Ok to install white vinyl vapor barrier.
2/9/21 Building Insulation Partial Approval
- Gable End Wall Insulation Approved R27. Ok to install white vinyl vapor barrier.
- vinyl vapor barrier installed on overhead door walls
Note: Correct R value is R27 not R25 as stated on previous inspection.
2/17/21 Building Insulation Partial Approval
- Above pre-existing gable end wall R27 approved
3/2/21 Building Insulation Partial Approva
- Air sealing not approved around side wall vents. I will recheck same time tomorrow.
3/3/21 Building Insulation Partial Approval
- Air Sealing Partial Approval for exhaust system.
Remaining Item:
- Spray foam applied at gap between wall sleeve and Durovent B-vent pipe at each Modine heater. 1" clearance
to combustibles required and foam must be removed around perimeter of B-vent and sleeve gap at each location.
Window Sealing Failed
U Factors = .3 cfm for windows, .5 cfm for doors Failed
Mar 03, 2021 Page (2)
INSPECTION WORKSHEET (BINS-008646-2021)
Checklist Item Status
Insulation Residential Check Commercial Check Passed
2/3/21 Building Insulation - Roof Only!
- Ceiling Partial Approval (R25 + R13 on south half of building).
2/4/21 Building Insulation Partial Approval
- Ceiling Partial Approval (R25+R13 on east half of north side.
Note: Inspecting balance between 1:00 - 2:00.
2/4/21 Building Insulation Partial Approval
- Balance of ceiling insulation approved R25+R13
2/5/21 Building Insulation Partial Approval
- End Walls at overhead doors R27 partial approval. Ok to install white vinyl vapor barrier.
2/9/21 Building Insulation Partial Approval
- Gable End Wall Insulation Approved R27. Ok to install white vinyl vapor barrier.
- vinyl vapor barrier installed on overhead door walls
Note: Correct R value is R27 not R25 as stated on previous inspection.
2/17/21 Building Insulation Partial Approval
- Above pre-existing gable end wall R27 approved
Duct work sealed properly / No duct tape Failed
Blower Door Test Failed
Combustion Air Supply for Furnace Failed
Fresh air supply 3' from grade Failed
Duct Insulation - if required in unheated spaces Failed
Mar 03, 2021 Page (3)
INSPECTION WORKSHEET (BINS-008646-2021)
Checklist Item Status
Door / Window Sealed (No Insulation)Failed
Air Seal Outside Penetrations Failed
3/2/21 Building Insulation Partial Approval
- Air sealing not approved around side wall vents. I will recheck same time tomorrow.
3/3/21 Building Insulation Partial Approval
- Air Sealing Partial Approval for exhaust system.
Remaining Item:
- Spray foam applied at gap between wall sleeve and Durovent B-vent pipe at each Modine heater. 1" clearance
to combustibles required and foam must be removed around perimeter of B-vent and sleeve gap at each location.
All Ductwork Sealed Return and Supply Failed
All Return Air Hard Duct Work Failed
Mar 03, 2021 Page (4)
O'Brien, John