Signed Inspection Report (Fri Mar 26, 2021 at 1056 AM)INSPECTION WORKSHEET (BINS-009164-2021) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0571-2020 Case Module:Permit Inspection Date:Fri Mar 26, 2021 Inspection Status:Passed Inspector:O'Brien, John Inspection Type:Building Insulation Job Address:Parcel Number:728 QUAKER RD Queensbury, NY, 12804 303.15-1-10 Contact Type Company Name Name Applicant Hilltop Construction Contractor Hilltop Construction Engineer Daniel W. Ryan, PE Ryan, Daniel Primary Owner R & P Quaker II Realty, LLC Granted Permission R & P Quaker II Realty, LLC Checklist Item Status Mar 26, 2021 Page (1) INSPECTION WORKSHEET (BINS-009164-2021) Checklist Item Status Building Inspector Notes Passed 2/3/21 Building Insulation - Roof Only! - Ceiling Partial Approval (R25 + R13 on south half of building). 2/4/21 Building Insulation Partial Approval - Ceiling Partial Approval (R25+R13 on east half of north side. Note: Inspecting balance between 1:00 - 2:00. 2/4/21 Building Insulation Partial Approval - Balance of ceiling insulation approved R25+R13 2/5/21 Building Insulation Partial Approval - End Walls at overhead doors R27 partial approval. Ok to install white vinyl vapor barrier. 2/9/21 Building Insulation Partial Approval - Gable End Wall Insulation Approved R27. Ok to install white vinyl vapor barrier. - vinyl vapor barrier installed on overhead door walls Note: Correct R value is R27 not R25 as stated on previous inspection. 2/17/21 Building Insulation Partial Approval - Above pre-existing gable end wall R27 approved 3/2/21 Building Insulation Partial Approva - Air sealing not approved around side wall vents. I will recheck same time tomorrow. 3/3/21 Building Insulation Partial Approval - Air Sealing Partial Approval for exhaust system. Remaining Item: - Spray foam applied at gap between wall sleeve and Durovent B-vent pipe at each Modine heater. 1" clearance to combustibles required and foam must be removed around perimeter of B-vent and sleeve gap at each location. 3/26/21 Building Insulation Approved -Received exemption letter from Thermal Associates regarding being unable to isolate the addition from the pre-existing repair bays. Mar 26, 2021 Page (2) INSPECTION WORKSHEET (BINS-009164-2021) Checklist Item Status Insulation Residential Check Commercial Check Passed 2/3/21 Building Insulation - Roof Only! - Ceiling Partial Approval (R25 + R13 on south half of building). 2/4/21 Building Insulation Partial Approval - Ceiling Partial Approval (R25+R13 on east half of north side. Note: Inspecting balance between 1:00 - 2:00. 2/4/21 Building Insulation Partial Approval - Balance of ceiling insulation approved R25+R13 2/5/21 Building Insulation Partial Approval - End Walls at overhead doors R27 partial approval. Ok to install white vinyl vapor barrier. 2/9/21 Building Insulation Partial Approval - Gable End Wall Insulation Approved R27. Ok to install white vinyl vapor barrier. - vinyl vapor barrier installed on overhead door walls Note: Correct R value is R27 not R25 as stated on previous inspection. 2/17/21 Building Insulation Partial Approval - Above pre-existing gable end wall R27 approved 3/26/21 Building Insulation Approved -Received exemption letter from Thermal Associates regarding being unable to isolate the addition from the pre-existing repair bays. Blower Door Test Passed 3/26/21 Building Insulation Approved -Received exemption letter from Thermal Associates regarding being unable to isolate the addition from the pre-existing repair bays. Air Seal Outside Penetrations Passed 3/2/21 Building Insulation Partial Approval - Air sealing not approved around side wall vents. I will recheck same time tomorrow. 3/3/21 Building Insulation Partial Approval - Air Sealing Partial Approval for exhaust system. Remaining Item: - Spray foam applied at gap between wall sleeve and Durovent B-vent pipe at each Modine heater. 1" clearance to combustibles required and foam must be removed around perimeter of B-vent and sleeve gap at each location. Mar 26, 2021 Page (3) O'Brien, John