Loading...
2004-444 TOWN QF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20040444 Date Issued: Tuesday; January 09, 2007 This is to certify that work requested to be done as shown by Permit Number P20040444 has been completed. Tax Map Number. 523400-252-000-0001-058-000-0000 Location: 50 WOODCHUCK HILL Rd Owner. JOHN & CYNTHIA COON Applicant: JOHN & CYNTHIA COON This structure maybe occupied as a: Fireplace By Order of Town Board Garage - 2 Cars Attached TOWN OF QUEENSBURY Porch IRS Ah11AgI(fjqtAficate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040444 Application Number: A20040444 Tax Map No: 523400-252-000-0001-058-000-0000 Permission is hereby granted to: JOHN& CYNTHIA.COON For property located at: 50 WOODCHUCK HILL Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JOHN& CYNTHIA COON Fireplace 50B WOODCHUCK HILL Rd Garage-2 Cars Attached. LAKE GEORGE, NY 12845-0000 Porch Residential Addition $65,000.00 Total Value $65,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2004-444 572 SQ FT RESIDENTIAL ADDITION, 660 SQ FT PORCHES, 900 SQ FT 2-CAR ATTACHED GARAGE $231.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,August 30, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queen before the expiration date.) Dated at the To n of u s , gust 30, 2004 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Buuldhig. Permit App]ication Town of Queensbmy—Dept of Community Development,742 Bay Road,Queensbury,NY (518)761.825d ' A permit must be obtained before beginning construction. Permit File No. No inspection will be made until applicant has received a Fco pad valid i;Wldiug permit. All applicants spaces on this Roo.Fee Paid . $ 1 application must be completed and must appear on the application form. Reviewed By; Applicant: Xo � '11= 0, �o� Owner: o+ rqM4A L 7 Address: 60 LutCpLl Address: 6kcm it Phone#O Phone Property Location: Lot Number:�„/ House Number J50 Subdivision Name: Tax Map Number: Z52— t o 0 New Building: residence /commercial 'Estimated Market Value of Construction: $ . ;.60®' f t Addition:-j residence commercial If an Addition,what will use of new addition be? 0 Alteration: res Bence/ commercial o No change to exterior size: residence/com'1 o Other work(doectibe Check OccnpancyYnformation 169FiqW 2° U0* Oth or Total Below .£t. q.ft. sq.ft. Square Feet Singlefinlilydwelling r5 7 Z al 00 4w 4- l Q D -2-j o Two f=RY dwelling o Townhouse o Multifamily dwelling #of units • Office 0 Mercantile o Maaufaotutin �, a l car detached e 0 2 car detached wage 0 3 car detached . ge 0 1 oar attached garage i U N 0 2 car attached pmge 0 3 car attaehod garage 0 Storage building- commercial o Storage building- residential _ ❑ O er What is the proposed height of the structure feet inches Will any second--hand or ungraded lumber be used? If so,for what? NZ> Type of Heating System: electric/ oil / gas wood /forced hot air/ baseboard/other:l Number of M=iaces to be installed. Number of 1 *&jgyg to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder C '7 S?71 Plumber Mason Electrician Deglltag= please sign below after you have carefully read the statoznent: To the best of my knowledge.the statements contained in this application,together with the plans and specifications submitted,are a true aad complete statement of all proposed work to be done on the described promises and that all provkioas of the Building Code,the Zoning Ordinanco and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall submit,prior to a Certificate of Occupancy or Certificato of Compliance being issued,as requested by the Zoning Administrator or Dir or of Building and Codes,an A.s built Survev by a licensed surveyor;drawn to scale,showing actual location of a ew ctioa. Signature: owner,owner's agent,architect,contractor Job Site Address: C4Gle-4,_- 4YUL Date: (0;0,hc�� Owner: �,6LW Cal Application No. File No. Db _Zlv� WINDOW SCHEDULE yv�x s'�t�a � .cs.�r"�^t�yc s.✓,� e t �, 'axc•xz sx ^g, �,. tv. �# _.._ 4 ,',�.�.: '.�..,en'�'�` "z��' f'"�..,�5,'� �."a:.., �:,:QPentng�S�eci1`ic2�i.4�s.,, �;,, ..i� .. •• �:.:.:. °'x',,.Window Window Mfg. Window Unit orata Rcatlgh SQ,TT SC`FT SIFT, Clear Clear Special Hardware or Number or Name Model Stock C� entz #fJ entn �'rlass�is7b �e�t�t p g l gress/Cl'eaI Qpeznng Oezxt sg 1lelht Instructions Letter on g , Or Type Number tdt1iG z le , c a° $ rs s a =zs Eetttng r' rll 111 G g�1i1 1rlG�leS .. z ryr •:..'w.0f tl3a` r xirig.lf � i.r.=. a§, .�. 31 Plan Call Size 5 a r gm �S-t ,5—Lv (l2 �• �� � --THIS LINE HAS EXAMPLES OF SAMPLE ENTRIES A Arider zt -" 77/�G *3"xf �:,. .r i<^ ��yy � � x.,� •;",*Ka,nr:4 2415/35'_.• Tempered �1.. .?...-� ..tlti.•"1a�`i} ��.'N C.(. ,� max# ,�e, �,i�. GY' X:'YS +P :.:�.5 Y,��y^� F.,e 5 ',l ,7:: :"YY4d x''t'�F L"f.l ',-.N'^T .,�.,� �.. d.7 ,ry. ..°..., a.:� .. w,xy a,.3r. G. =".011p .*„- .;.yf § .:x 4Y, �}Y.. tt:..,E'sYa. �S :,f. `a•!r ��.+4 ,,,¢$" . .S"P'1„a<�16'.. fr_ r!.f. 14„}'vw.F�✓1�,j1..�;r°<.:;�:4? r,t yxtf��.4df�.,$ + g. +�..f sl �",��`�r� 11 's �..3.z'. t?r- .'.':`�:"' .fi e. ':a: 3. Glazing: a ..i< .<. >k. i .t .}.fi•s �xc<"5�'�` v�C:+�'t�d Z �..� .t. .}t: �. #T.�J s Y ,ty �.:,,4 � y�;. tEx L:\SueHemingway\Building.Permit.FORMS\Window Schedule.doc Job Site Address: 60 WcpDFG(C .- Z'C,C, Date: 0A 25/24 Owner: lam( C1 Jo- Application No. File No. Building Permit — Calculation Sheet Natural Light, Ventilation & Emergency Egress Requirements Habitable Area of Req.Light Actual Req.Vent Actual Sq.Ft. Remarks Room Room 8%of Room Light 4%of Room Vent C=?F Opening for r P g in Area Square 3@ ' Area Square Egress Square Footage Footage Feet *a 31 y {{ C fi y y firy� r a �� � i J� 1 (Ada p y'C ;It, Its, L:\SueHemingway\Building.Permit.FORMS\NatLight.Ventil.Calculation.Sheet.doc 2P Check Residential Plan Review: One &Two Family Dwellings YIN/N/A \/ (2)Full sets of plans Over 1,500 sq.ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade, 5.7 sq.ft. / Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK /V Dampproofing/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6"Drop in 10'Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where Required Iee and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise Winder Run and Rise Spiral Not Allowed From 2n Story y Smoke Detectors Battery Backup and Proper Location N � Bathroom Fixtures Proper Clearance Hall Width, 36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped Attic Access . H ((0" Roof over 30"—22"x 36"/Crawl Sp ces 18"x 24"Access r� Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results,if required Septic To Well Or Water Line Separation All Paperwork Signed Town of Queensbury 742 Bay Road, Queensbury, NY 12804 -Building & Code Enforcement Building Permit# phone:(518)761-8256 Date- Fax: (518)745-4437 Email: codes@qucensbuq.net P Dear y Your binding permit application has been reviewed and found to be deficient in the following areas: Ue6of (/h %` P�!✓c+r� �a ''e/ / <G�tl i/- Ad j lxsr .� �J�f/ �/�y /�'/ai��}o/�(c. .z0'z !� G /•L / /i S9'�'vc0(�r-2. These det&*need to be added to or noted on both sets ofph= Please feel free to contact this ofF"with any gwsd(> s regarding ibis nafter. ... Sincerely, BUILDING&CODES OFFICE L.LSneHemingwayWuiWing:Pa7r iLFORMSWericient bUjWiA2perrniths2oD3-doc Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY (518)761-8205 Application for Fuel Burning Appliances &.Chimneys applicable to solid fuel & vented gas.appliances Date 24 � , Permit No, t..("?( �- , .{, .� Application is hereby made to the Building& Codes Office for the issuance of a Building and Use Permit pursuant to the New York State Fire Prevention and Building Code. The applicant or owner agrees to comply with all applicable laws, ordina ices, regulations, and all conditions that are part of these requirenaetnts and also will allow all inspectors to enter premises to pet f4rrn required inspections. NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information Fuel Burning Appliance Information (circle appropriate words) Name: Stove: wood coal pellet gas Fireplace insert Address: Ci> = l - _3 Fireplace, factory-built: wood � as.. Fireplace, masonry: wood gas Furnace: wood gas oil Phone: 7`l<°. If non-masonary applicance, please provide Owner: :=i t ..6, : F.,zf:�a* Manufacturer Name: �� o°`. t �jt"-- Address: Model Number: " Chimney Information Phone: (circle appropriate words) Masonry' block brick stone Flue tile steel size: inches Exact Address: of construction or installation a fFactory-Built 1Vlanufacturer name: Model Number: Note: Listed By: Number: Construction/Installation must cote. ortn to NYS Fire Prevention &Building Indicate (circle) chimney material: Code. Consult available Town of Queenshury Handouts regarding required inspections. Double ivall / ` Triple wall / Insulated / Direct venting �) r¢� Chimney Liner Ca,,�if�x-',�Depar�m�e�ut—Toi�ri of Que��ne�®rbu�ry, 1V"e�7[�or�;-- Fire Marshal Code#1 3 Collected $Refunded Received from (refunded to); °+�,:t_; A 173 3389 (190) Public Safety A 233 2655 (230)Minor Sales ,ATc: White(Applicant) / O•een(Fire Marshal) / Yell€owt(g'lag.Dept.) / Pink R Goldenrod(Cashier's Dept.) Town of Qmeeodxiury Fire Marshal 742 Bay Rw d Queadwry,NY 12804 761-nM/761-9206 fax 7454437 Factory Bait Gays Fir+ealace 0 Stove Inspection Reoort Notice:New Yo&State requires that all UL IAd4 factory bdtt appliances be installed aeeordmg to the inns and SPOCifiCIGONS ooKWWd lo the IRStalIZOOM h+lanast WCOMpanying tide appliance.No deviation from the manufadumes imzWwtkm or speefficatiew is allowed Pia�it# Scbcft a InBp �f n I-a 3 s ,® ytiffie h •� ' NUW Add¢ess 4f�InMal Appliance i�Ianafadarer �1rN1� t' }s-�-� r•yy model# '� l J Direct veg�ai"s ry Built iilwe Size Double Kull Triple Fall Insulated Yee No NIA Comments Floor Protection Clearances to Combustibles(all sides) Fir+estop(s) vertical Chris Wall ra mb-Ation, Vent Clearances to Combustibles Vent/Chimney Termination Cbimr cy mat be 3 feet above roof penetration;2 feet above any combustible within 10 feet Gas ShutAM Valve Combustion Air Hearth Extension(if any) 10 ILOP V Mantel HeCbt above Up opem" 'I Witness Operation Tank Placement(If LP) 'dam of Q,oenbary Fire blamhal 742 Bay Road Qaemftry,➢.11Y 12804 761-5205/761-SM fax 7454437 Factor Built Gas Fireplace 0 Stove Inspection&Nrt Nab=New York State cegnim that all III.Lasted,factory bWt appliaaoes be installed according to the ioskoctions and contained in the butAntion Manual accompanying the ap&aeoa No deviation from the mamdaclunees indnictiow or specifirations ( is allowed. permit 0 -- Sihedale kgmAon 1 I Time ( anytime Vodor�J� � � j Rase Adds ..� t ,�cis / Rough La Apprumce Mudd 0 Duct Vent�aF ry Baia Chimney Flan;Size Double Wag Triple Wall Eu lated Yes No N/A Commends Floor Protection Clearances to Combustibles(all sides) Fireatop(s) Va6cal Chase Wau Paaetrvtioa�" Vent Clearances to Combustibles Vent/Chimney Termination CUmsey bdgbt meat be 3 feet above roof peaebidiw,2 feet above any cowbwfible eomttaaetion with"10 feet Gas Shut-Off Valve f Combustion Air Hearth Extension(if any) Mantel Hoot above Rp%waing Witness Operation Tank Placement(If LP) White—BoUdIng DepL Ydi- Pblkk—Me AE"IW Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: m De am 6m � Date Inspection request received: _ Inspector's Imtials: r vJ NAME: I MIT#: LOCATION: ATE: TYPE OF STRUCTURE: Comments _ Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more / Guard at deck,porches.36 inches or more �• Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet t � 6 inch clearance to sill plate _ Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safe lazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .1-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly •� �� Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic S stem/Sewer Dept.Inspection Sti ker Site Plan /Variance re red Flood Plain Certificati ,if re 4 ui d Okay to issue C/C q C/20emporary/ ermanent L:\Building&Codes Forms\Building&Codes\Inspection FormsTesideV- Final Inspection Form_revised_100405.doc -�� muly ain Y. //8/p/ Queensbury Building & Code Enforcement - ResidenZa1 Inspection Office No.(518)761-8256 Arrive: I a Date Inspection request received: Inspector's I NAME: M _ZV--k LOCATION: Z) �/I TYPE OF STRUCTURE; Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more ! Guard at deck,porches 36 inches or more / ✓� Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches (height in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum%s"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/<hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form—revised-1 00405.doc -OMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No.. .............. Cert. _ 90935 but-in Card No..................................... t � Owner......... ............*9................ . .....✓ ....I. .�.. ..................... ............ ............ff .. .... ... Location......>�p......... JdL.'..Ef L,I.. L. ...... �s�a y�� ..... .... ............ . In Nation Consisti Of../............ ... .... l �` ....... l`....�.0...2..f�*.�''/....:7......... Di �'.�aJC>jt' ................................... .................... ...........,�............... , ........:::::.................................. InstalledBy.. .....:.....................................................Lie.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment an //nstallation conditions as of date. Upon the introduction of additional equipment or alterations,applica 6n shall/ promptly made for inspection. Inspectors of this-Company shall have the privile of mak'd inspections at time, and if its rules are violated,the Company shall have the right to voke cc if. ..7tr ............ INSPECTOR ! .... ....... . Me er N. . .A..I.A. MR) Queensbu Building & Code9nforeement - Reside 1 Final Inspection ry g p O .�;e No.(518)761-8256 Arrive. e �� am! Date Inspection request received: Inspector's Init NAME: P RMIT M �y LOCATION: ✓DATE: TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location i Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors > Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railiri s 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers S,IL"-( Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate S �AJ� Gas Valve shut-off exposed/regulator 18 inches above grade / �A Interior privacy/trim/doors/main entrance 36 inches !� Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Tern 110 Enclosed Stairs Sheetrock Underside minimum''/z"Gypsum Basement stairs closed rise nc Garage Floor Pitched Garage fireproofing/ /4 hour fire d96;//_door closer Duct work Sealed pr2e Gas Logs in Sealed or Glass Enclosure :�3� ,mac Final Electrical �� C>D :"'� Final SurveyPlot Plan �� p� C`q As Built Septic System/Sewer Dept.Inspection Sticker AJ��-` Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form—revised-1 00405.doe Framing/ Firestoppinq:; Inspects% ort Office No. (518) 761-8256 Date Inspection equest e ve < Queensbury Building&Code Enforcement Arrive:: am/ art: a in 742 Bay Road, Queensbury,NY 12804 Inspec�or s In', ial NAME: PERMIT#: O L—(Ll Ll LOCATION: INSPECT ON: — S TYPE OF STRUCT lV N/A aming COMMENTS Attic Access x 30"minimum Jack Studs/Headers Bracing/Bridging Joist hangers �• Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I %z w 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall r ire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection reques c-' ed° Queensbury Building & Code Enforcement Arrive: /p part: gyp am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initi Is• �� J NAME: PER T #: C) L1 qq LOCATION:_ 7 1 INSPECT ON: TYPE OF STRUCTURE: Y leT N/ARou h Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air ead VP.S.I for 15 minutes R o nsulation / Residential Check / Commercial Check Proper Vent Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&CodeAnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Z V g � ; Framing / Firestop nss�- tion�e t l p ll Office No. (518) 761-8256 Date Inspectionr- IQueensbury Building& Code Enforcement Arrive: t: � (.�am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initi C� 0 NAME: PERMIT#: _ LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A F aming COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping �) Penetration sealed / 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X I Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemiii-way\Building.Codes.Inspection.FORMS\I--raming Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection reque ce ed• a Queensbury Building & Code Enforcement Arrive: _a pm art: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initial L NAME: ? PERMIT#: d LOCATION: D t c k '( INSPECT ON: 3 o� TYPE OF STRUCTURE: lv N/A COMMENTS TS 1 Framin Jack Headers �� , � �� �— racing /Br grog �DQ�r,*z angers1 �l t,) 1b Jack Posts/Main Beams rt7ZIVC�� Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Z Garage Fire Separation 1� House side %2 inch or 5/8 inch Type X �7g - �� )4— ©tV Garage side 5/8 inch Type X Ceiling/wall } -rp 6 c�— Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report i Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: I V1 arn/pm Depart: ar&pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: ' f NAME: [X%Yl PERMIT#: �' 1444 —\ LOCATION: Woo l INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS rJackStuds /Headers g/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches frorn wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour irestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHeminmvay\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 ti Rough Plufnbing /Insulation Inspection Report Office No. (518)761-8256 Date Inspection re est ece' ed: Queensbury Building&Code Enforcement Arrive: m/p ep t: , a p� 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: C PERMIT#: LOCATION: �h0 ��0©C�CFiIC, 1Ll—f�� INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper,CPVC,Pex One &Two Familyc'� Insulation/Residential Check/Conunercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: L:\SueHemingwayl3uilding.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doe January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection re ue t - eiv G __ Queensbury Building& Code Enforcement Arrive: 742 Bay Road, Queensbury,NY 12804 Inspector's Initial . NAME: \ PERMIT #: aU(o � LOCATIO / INSPECT ON: /v TYPE OF S RUCTURE: .-� , �� �� z -. Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.. Drain Size Washing Machine Drain 2 inch nun. )head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial C CPVC,Pex One and Two-Fanul nsula ' esidentiai Check/ Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air S!!pply for Furnace Duct work sealed properly/No duct tape COMMENTS: LASueHemingway\Building.Codes.Inspection.FORMS1Rough Plumbing Insulation Report.doc November 17,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection reque reoe}rd: Queensbury Building& Code Enforcement Arrive: _aI D part: 742 Bay Road, Queensbury, NY 12804 Inspector's Initials ` NAME: PERMIT#: Q00 Li LI, LOCATION: INSPECT ON: TYPE OF STRU RE: Y N N/A raming COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses r Anc r Bolts 6 ft. or less on center I e and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour � irestopping s� Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SucHemingway\Building.Codes.lnspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 �_ � �_-) ��- /0 A"LA Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection r•equest rece�ugd: ?- G Queensbury Building&Code EnforcemLArrlve: _�am/p De rt: /mm� 742 Bay Road, Queensbury, NY 12804spector's In tivl awls:_-IT - NAME: C con PERMIT#: � -l LOCATION: 0V � INSPECT ON: Q `� TYPE OF STRUCTURE: Y N N/A \ raming EATS Jack Studs/Headers \ __ Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses � Ln Anchor Bolt 6 ft. or less on center Ice and snow shiel 24 inches from wally'�� Fire separation 1, 2, 3 our Fire wall 2, 3, 4 hour ---� Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASucHerningway\13uilding.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report - Office No. (518) 761-8256 Date Inspection request received: 91A, 0 Queensbury Building&Code Enforcement Arrive: am/pm Depa : p;`v�m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: _ PERMIT#: 0 - 40 LOCATION: Q C, _ INSPECT ON: 01) TYPE. OF STRUCTURE: I Comments ------ Y N/A 7 ootings /��V�'-x- y � Piers IC D5 Monolithic Slab Reinforcement in Place •2� The contractor is responsible foi providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above .footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASucHomingway\BuiI ding.Cod es.Inspection.FURMSToundation Inspection Report.doc January 28,2003 1 Foundation Inspection Report Cl Office No. (518) 761-8256 Date Inspection request received: _ _ Queersbury Building&Code Enforcement Arrive: anVp Depart: ��am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: _ CUB PERMIT#: �C7o LOCATION: U UUU+7 L('�vC 1�. I ( t — 1NSPECT ON: �' C✓ _^ TYPE, OF STRUCTURE: Comments ootings Piers Monolithic Slab Reinforcement in Place The contractor is responsible providing protection from freezing for 48 hours following the placement of the concrete, Materials for this pu_pr ose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:1SucHcmingway\Building.Codcs.Inspection. ORMSU�oundation Inspection Report.doc January 28,2003 6CAL : 1 ;,r too e 00// - 1.6' CLEAR ©� DArI,L eci ±15 / \ 40 5- 03`32'25" E ri. r. f. op 25.00 -, = 40"=35" W �i.r.f. 25.00 ' . - N- 83''34'- 05 - w Q gar. 18 2 . 62 ' N-6 4'- 12'-_2_5.' W 100. 00ol ' 3.22 ACRF- 5 fi Gs: TO CENTERLINE nF RnAn ��.\ Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release le _ Data filename: C:\Program Files\CheckU&Scheck\3040-04 Coon Addition.rck COUNTY:Warren STATE: New York HDD:7635 J CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE: 06/17/04 PROJECT DESCRIPTION: 43040-04 John&Cynthia Coon 50 Woodchuck Hill Road Lake George,NY 12845 DESIGNER/CONTRACTOR: Northern Design&Building Associates,Ltd. P.O.Box 47 Hudson Falls,New York 12839 518/747-2200 PROJECT NOTES: Efficiency values`for furnace and air conditioning are the minimum allowed by code. Any units used with higher efficiency values will raise the"%Better Than Code"value. COMPLIANCE:Passes Ibiaximum UA=483 Your Home UA=472 2.3%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Cathedral Ceiling(no attic) 572 30.0 0.0 19 Skylight 1: Wood Frame:Double Pane with Low-E 14 0.370 5 Wall 1: Wood Frame, 16" o.c. 629 21.0 0.0 32 Window 1: Wood Frame:Double Pane with Low-E 51 0.360 18 Door 1: Glass 21 0.320 7 Floor 1: Slab-On-Grade:Heated 572 10.0 391 Insulation depth: 4.5' Boiler 1: Other(Except Gas-Fired Steam), 80 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and ......... -signed this page,they are attei.tinglthat to the best of his/her knowledge,belief,and�pro&ss'iiDnaijudgment,,suchplans-or specifications are in coliance v 'th this:Code.IT, Builder/DesignerDateA&7�O 0 0 068955 JUN 1 8 2004 REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release le DATE:06/17/04 Bldg. Dept. Use 1 I Ceilings: ( ] I 1. Ceiling 1: Cathedral Ceiling(no attic),R 30.0 cavity insulation Comments: I ' Above-Grade Walls: [ ] I 1. Wall 1: Wood Frame, 16"o.c.,R-21.0 cavity insulation ' I Comments: 1 Windows: [ ] I 1. Window 1:Wood Frame:Double Pane with Low-E,U-factor: 0.360 1 For windows without labeled U factors, describe features: #Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: I 1 Skylights: [ ] 1 1. Skylight 1: Wood Frame:Double Pane with Low-E,U factor:0.370 1 For skylights without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: Doors: ' ] I 1. Door 1: Glass,U-factor: 0.320 1 Comments: 1 Floors: ( ] I 1. Floor 1: Slab-On-Grade:Heated,4.5'insulation depth, R-10.0 continuous insulation Comments: Slab insulation to extend down from the top of the slab to at least 4.5 ft. OR down to at 1 least the bottom of the slab then horizontally for a total distance of 4.5 ft. 1 Exterior insulation must have a rigid,opaque,weather-resistant protective covering that 1 covers the exposed(above-grade)insulation and extends at least 6 in.below grade. ' I Heating and Cooling Equipment: 1. Boiler 1: Other(Except Gas-Fired Steam), 80 AFUE or higher Make and Model Number I 1 Air Leakage: [ ] 1 Joints,penetrations,and all other such openings in the building envelope that are sources of air 1 leakage must be sealed. [ ] 1 Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-IC rated, the fixture must be installed with a 3" clearance from insulation. I Vapor Retarder: [ ] 1 Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. 1 1 Materials Identification: [ ] Materials and equipment must-be installed in accordance with the.manufacturer's-installation instructions. [ ] I Materials and equipment must be identified so that compliance can be determined.. [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be-provided.`s [ l I Insulation R values and glazing U-factors must be clearly marked on the building plpecifications. I ans or s, Duct Insulation: [ ] I Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] I Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] I Supply ducts in unconditioned spaces must be insulated to R-11. [ ] I Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. I Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g. (500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] I The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. I Electric Systems: [ l I Separate electric meters are required for each dwelling unit. I _ Fireplaces: [ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors., [ ] I Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code,as applicable. I Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ l I Insulate circulating hot water pipes to the levels in Table 1. I _ Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. I . Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes .Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0:5 1.0 Table 2: Minimum Inw1ation Thickness for HIVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts 1" and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)