Loading...
Signed Inspection Report (Wed Mar 31, 2021 at 1146 AM)INSPECTION WORKSHEET (RESFINAL-009232-2021) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0549-2018 Case Module:Permit Inspection Date:Wed Mar 31, 2021 Inspection Status:Passed Inspector:Dyer, Charles Inspection Type:Residential Final Inspection Job Address:Parcel Number:12 Chestnut LN Lake George, NY, 12845 226.19-1-20 Contact Type Company Name Name Applicant McNeice, Laura Engineer Hutchins Engineering Granted Permission McNeice, Laura Architect Jelley, Frank Primary Owner McNeice, Laura Checklist Item Status General Comments Passed 11/3/20 walk through for CO Items from previous list completed/ OK to issue CO 4 inch Building Number Address visible from road Passed Provide 4" house numbers Provided Chimney Height / B Vent / Direct Vent Location Passed Fresh Air Intake Passed Fresh air supply 3' from grade Passed Mar 31, 2021 Page (1) INSPECTION WORKSHEET (RESFINAL-009232-2021) Checklist Item Status 3" Plumbing Vent through roof minimum 18 inch Passed Outside Spigots have Air Gap Passed Not yet installed Installed and verified Roof Complete / Exterior Finish Complete Passed Platform at all exterior doors Passed Provide guards and handrails at balconies Completed Handrail 4 or more risers Passed Guards at stairs,decks,patios 30" + above grade Passed Guard at stairwell at 34" or more Passed Window guards req:<2' above floor/6' above grade - quick release installed Passed Guard at deck, porches 36" or more Passed Handrail Termination at Newell Post or Wall Passed Interior/Exterior Railings 34 to 38 Passed Mar 31, 2021 Page (2) INSPECTION WORKSHEET (RESFINAL-009232-2021) Checklist Item Status Wood deck: 2'+ from grade dia bracing required - H/C ramp compliant Passed At front entry 4+ Deck Joist Ledger Connections-24" From Ends Passed At front entry Deck Ledger-Bolted per Code Passed Front stoop Grade away from foundation: 6" down, 10' out Passed Not completed Raking out top soil 6" clearance to sill plate Passed Gas Shut-off Exposed & Regulator (18) Above Grade Passed Propane HVAC Vent Terminal 10' from Lot Line & Openings Passed Dryer Duct Max Length 35', Labeled Over 35'Passed Interior privacy/trim/doors/main entrance 36 Passed Bathroom / Kitchen Watertight Passed Low flow toilet 1.3 gal/flushing cycle - showerhead/faucet Passed Mar 31, 2021 Page (3) INSPECTION WORKSHEET (RESFINAL-009232-2021) Checklist Item Status Smoke Detectors:Passed Smoke Detectors 3' from Kitchens & Baths R314 Passed Every level, Every bedroom Passed Outside every bedroom area Passed Battery backup: _____Passed Inter Connected Passed Carbon Monoxide Detectors:Passed CO Detectors within 10' of all sleeping areas Passed Attic Access 22 x 30 minimum Passed Attic Access Insulation = Attic R- Value Passed Provide ceiling insulation at access hatch Attic Access Gasketed Passed Provide gasket Crawl Space Access 18 x 24 Passed Mar 31, 2021 Page (4) INSPECTION WORKSHEET (RESFINAL-009232-2021) Checklist Item Status Bathroom Fans, if no window Passed Plumbing fixtures Passed Not yet installed Installed and working Backflow Preventors where required Passed Foundation insulation to floor Passed ICF's Energy Sticker on Elec. Panel:R-Val. & Heating Sys Passed All Hot Water Systems: 3/4" or larger piping R-3 Passed Duct work sealed properly Passed Intake Openings Passed Range Hood 400+ cfm-Fresh Air REQUIRED NA Blower Door Test Certification Passed Must provide for CO Provided by T. Locascio HRV or ERV Installed per Bedroom Requirements Passed Mar 31, 2021 Page (5) INSPECTION WORKSHEET (RESFINAL-009232-2021) Checklist Item Status Emergency egress below grade Passed Crawl area Furnace shut-off w/in 30 ft. or w/in line of site Passed Propane Tank: Proper Setback from Prop Line/Struct Passed Furnace/Hot Water Heater operating Passed Low water shut-off boiler NA Relief Valve ,Heat Trap/Water Temp 110 deg or less Passed In process of being installed Basement stairs closed rise greater than 4 inches Passed Provide risers no more than 4" gap as discussed Basement Egress: 5s.f. window w/sill or Bilco door NA Crawl area Jack posts in basement lagged at top and bottom Passed Fin Elect; Energy Saving Light Bulbs 50 Percent Passed Final Survey Plot Plan Passed Provide for CO Mar 31, 2021 Page (6) INSPECTION WORKSHEET (RESFINAL-009232-2021) Checklist Item Status Arc Fault Breaker Habitable Spaces Passed Flex Gas Pipe Bonding Passed Propane As Built Septic System Passed Provide septic asbuilt Site Plan / Variance required NA Flood Plain Certification, if required NA Fuel Tanks above flood plain elevation NA Buried Fuel Tanks anchored in flood zone NA Truss ID Signage Installed at Electrical Meter Passed Provide sticker with V over R at electrical meter panel OK to Issue C/O Passed Mar 31, 2021 Page (7) Dyer, Charles