98-312 CERTIFICATE OF COMPLIANCE TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK Date 19 q This is to certify that work requested to be done as shown by Permit No. 98312 has been completed. This structure may be used as a SEPTIC ALTERATION Location 134 LAKE PARKWAY Owner ADAMSON P CHARLES & TAX MAP NO 9 > —1 -1� By Order of Town Board • TOWN OF QUEENSBURY Director of Building & Code Enforcement BUILDING PERMIT TOWN OF QUEENSBURY No: VALUE $ 0 98312 TAX MAP NO. 9.-1-10 WARREN COUNTY, NEW YORK PERMISSION is hereby granted to ADAMSON, rmitit Y OWNER of property located at 134 LAKE PARKWAY Street.Road or Ave. in the Town of Oueensbury,To Construct or place a SEPTIC ALTERATION. at the above location in accordance to application together with plot plans and other information hereto filed and approved and in compliance with the Town of Queensbury Building and Zoning Ordinance. t. OWNERS Address is LILLIAN TRUST 134 LAKE PARKWAY LAKE GEORGE, NY 12845 2. CONTRACTOR or BUILDER'S Name. • QUEENSBURY SEWER 3. CONTRACTOR or BUILDER%Address 0 4. ARCHITECTS Name 5, ARCHITECTS Address 6..TYPE of Construction—(Please indicate by X) SEPTIC 1 1 Wood Frame ( I Masonry (.I Steel 1 7. PLANS and Specifications SEPTIC ALTERATION. AS. PER. PLOT PLAN SPECIFICATIONS No. - , 8. Proposed Use SEPTIC ALTERATION 25 June 5 2000 $ PERMIT FEE PAID—THIS PERMIT. EXPIRES '19 (If a longer period is required an application for an extension must,.be made to the Building and.Zoning inspector of the town of Oueensbutybefore the expiration date.) 5. June 19 Dated at the Town of Queensbury this ..,Day of 19 SIGNED BY < for the Town of Queensbury Building and Zoning I ctor :T,tippiicauun iur air I tl, LiarlJ31-iL t'LK1V111 . ( Town of Queensbury 9 Dept. of Community Development Permit No. V Building &Codes Office 742 Bay Road , . — 1 V Fee Paid - $,,a5, Queensbury, NY 12804 Location of property for installation: ‘ polc,e, (I— oi Property Owner's Name: C c-( ( ' S /7-c1 elk),_co-,C) t' { ,:�:tril ' c Property Owner's Mailing Address: 1 ? V I u4 p v Lc% JUN .0 31998 Installer's Name: 4 nrs S. osj� Phone # ` ^`� 7 Number of bedrooms (if residential): 3 Total daily flow: (residential - compute @ 150 gal./bdrm.) Topography: flat, rolling, steep slope % of slope Soil Nature: }C sand, loam, clay, other / depth: Ground water: at what depth? feet / Bedrock or Impervious Material: at what depth? _ feet Percolation test: not required, required [rate 7 min. per inch ] i Domestic'water supply: municipal, well, other (�/44' ,,-,i e, If domestic water supply is a WELL, water supply from any septic absorption is feet. PROPOSED SYSTEM Septic tank: / U7)7) gallon (minimum size: 1,000 gal.) Tile field: each trench L-`J feet / Total system length: _ OtV feet Seepage pit(s): number of / size each: ft. by ft. Size of stone to be used: # J1 Z / depth or thickness / feet HOLDING TANK SYSTEM: (if required) Number of tanks: Size of each: gallons CAlarrn system and associated electrical work to be inspected by a certified agency. J For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal , ce. Signature of responsible person: �'" Date: 6 ' J - 7 TOWN OF QUEENSBURY BUILDING & CODE ENFORCEMENT 742 Bay Road Queensbury NY 12804 • (518) 761-8256 SEPTIC DISPOSAL S TEM I S ECTION Name - _ t►,_ . : A,,,_ Location 1 i. N,i-.. Date (0 — --(1 'e rm i t # `.. — SOIL TYPE: Sand-Lom-Clay- Results of Percolation Test- (if applicable) Rat -Minute/Inch TYPE OF SYSTEM: ABSORPTION T tal Length Length of eac Mncyh k57� c'i) Depth of trenches Size of stone Q OA SEEPAGE PIT mber� Size - t. Stone size PIPING: Size Type Bldg. to Tank Viz ;- % ;6PE,C -V, Tank to Dist. Box- - " /Vovc _ i'-'irto Dist. Box to Field/Pit A'. oOP Openings Sealed? Yes No Partial LOCATION/SEPARATIONS. ~ ‘v39E0 Foundation to Tank ► �,�, feet Foundation to Absorption feet Separation of Pits / - feet Conforms as per Plot plan -.4: ' . LOCATION OF SYSTEM ON' PROPP`' : (circle one) Front - Rear Left1 Side - Rig t Side • e . t - dle Rear C ENTS: ,/ h l' Pit— ,, --1--E_C-TVA ,\ SYSTEM USE APPROVED: E NO Arrived: 0' 0 Depart Buildin ctor TOWN OF QUEENSBURY BUILDING & CODE ENFORCEMENT 742 Bay Road Queensbury NY 12804 (518) 761-8256 SEPTIC DISPOSAL SYSTEM INSPECTION Name C-VAPP-L F- ' Ant- 4 k\ Location % �L4 , �_ p l Date Kqp n Permit # o -- i SOIL TYPE: Sand Loam-Clay- Results of Percolation Test- (if applicable) Rate-Minute/Inc TYPE OF SYSTEM: - ABSORPTION FIELI Total Length Length of each' wench Depth of trench- Size of stone SEEPAGE PITS: N mber- Size - f . x f . Stone size PIPING: Size Type Bldg. to Tank Tank. to Dist. Box Dist. Box to Field Pit / Openings Sealed? Yes No Partial LOCATION/SEPARATION : Foundation to Tank feet Foundation to Absorp, io feet Separation of Pits _ feet Conforms as per Plot ,°1 an Yes No LOCATION OF SYSTEM ON PROPERTY: (circle one) Front - Rear - Lef/t Si e - Right Side Middle Front - Middle R ar COMMENTS: -1-6 ' vi SYSTEM USE APPROVED: YES Arrived: i_ i Departed: 1 N-_ i iding Inspe . o, "" i j � r i SITE P s�Oye. - V • to 1 = __ __ Z 1S ..................�r-I -, no u? �� •' EXISTING REES _BEING MOVED LOCATION PLAN _ ----- ISTRIBUTION BOX MIN. Z EFFLUEN 5' ,Y , �- `f F�RC PUMP ST TI❑N G A R A G E I�NcA ' MAIN A EXISTI G W S , _ oa `V 1 QED 1,000 G L. SEPTIC TANK APR❑XIMATE LOCATION EXISTING SEPTIC - SYSTEM _ - E wo SIDEN zW z RE i IL-1 G f-- w z a_ r w a a� `o ��r��M`I�IMl1 • >lnr ft*bnee of, r but fellCeS etc., � t f atbo represent that I have d n the diagram." w } IGNA DATE Ftia re z TE w LEGENn w � M Qi Z 1� PERCOLATIOM TEST TEST PIT Date: APRIL 24, 1998 EXISTING GRADE Scale: 1" = 10' G 330 FINISH GRADE � P 49017 SHEET 1 OF 2 co Nnr CONCRETE OR STONE FINISHED MARKER ABOVE ALL BURRIED COVERS � GRADE RECOMMENDED. W $Zo Z w ACCESS HATCH4 _ _ 1 INLET BAFFLE 12" MIN. COVER OVER 12" MAX. I'i o ALL STRUCTURES ELECTRICAL p 6" MIN. JUNCTION D oo$ Op dJ0 . ► •' .. O O 0 �� INTERCONNECT ENDS 6" MIN. g� OQU BOTTOM OF BED 4" PERFORATED PVCTar OF LATERALS N $� ALL OUTLET INVERTS LATERAL, LAID LEVEL 4" BUILDING SEWER ' TO BE SET AT UBMERSIBL PUMP EXACTLY THE SAME 4" PVC ELEVATION. PEA GRAVEL STANDARD ABS_ ORPTION BED PROFILE ALARM ON— _ � E 2" FORCE MAIN DISTRIBUTION BOX z SLOPE TO DRAIN N•T•S• �f" , PUMP ON 2" DIA. PIPE BACK TO PUMP STATION ^ w N.T.S. ` 0 0 PUMPS OFF •� OD CHECK VALVE., T�� �-i1 � iv Z. V1 : . : � A a e, a a. *. ► ► ►. ► , CONCRETE TO BE ~ TROWEL FINISHED 91 " SWALE AT UPHILL SIDE O � 4-0 LD. PRECAST CONCRETE MERCURY FLOAT OF BED TO DRAIN RUNOFF w 4) MANHOLE WITH INTEGRAL BASE EFFLUENT PUMP AND FLAT SLAB TOP. SWITCH WITH AWAY FROM BED SLOPED TO DRAIN w AS MANUFACTURED BY FORT MILLER WEIGHT (TYP.) OR EQUIVALENT O (NO LADDER RUNGS) EARTH _ w FILL FEII �I 6" TO 12" BACKFILLT 11 FILTER FABRIC EXISTING_ SEPTIC TANK PUMP STATION OR GEOTEXTILE N.T.S. 4" PERFORATED N.T.S. 2" MIN. 1. PUMP TO BE EFFLUENT PUMP RATED AT A MINIMUM OF 30 GPM LATERAL AT 20 FEET TOTAL DYNAMIC HEAD. PUMP TO BE 1/3 HP GOULDS MODEL 3885WE03L OR EQUAL 2. PUMP CONTROL PACKAGE TO BE SUPPLIED BY MANUFACTURER. 000 AUDIBLE AND VISIBLE ALARM TO BE ACTIVATED BY ALARM FLOAT to ��p0 ���0� p o 0 3/4" TO 1 1/2- CRUSHED STONE '-0" 2.-6" (TYP.) 36" MIN. MAXIMUM GROUNDWATER ELEVATION = w 4 O cAq Y� I- ABSORPTION BED SECTION STANDARD z o PIPN.T.S. a � z Ii+ m a a� U a z INSTALLATION STALLATI GN OF DISPOSAL FIELDS SEPTIC SYSTEM DESIGN SOILS DATA w w z I~ 111 1 DESIGN FLOW — EXISTING 3 BEDROOM HOUSE WITH WATER SAVING 0 —12" TOPSOIL . CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING, CA 12-28" LOAMY SAND AND SHALL BE IN ACCORDANCE WITH THE N.Y.S. DEVICES AND 1 GALLON FLUSH TOILETS = 270 GAL/DAY 28-48" FINE SAND W/TRACE SILT DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS, AND AS TANK — NEW 1,000 GALLON TANK INSTALLED 1997 MOTTLING AT 36" T'M F481-76 INSTALLATION OF THERMOPLASTIC PIPE AND w � SEPTIC A CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS. PERCOLATION TEST — 7 MIN. 10 SEC. STABILIZED RATE 2. NO HEAVY EQUIPMENT SHALL BE ALLOWED WITHIN THE LIMITS ABSORPTION BED — 7 MINUTE, 10 SECOND PERCOLATION RATE = 0.8 GAL/DAY/SQ.FT. OF THE DISPOSAL FIELDS AFTER PIPE INSTALLATION HAS BEGUN. w U 270 GAL/DAY + 0.8 GAL/DAY/SQ.FT. — 337.5 SQ.FT. REQUIRED SOIL & PERC. TEST BY NACE ENGINEERING 12/21/97 USE 15FT X 25FT BED = 375 SQ.FT. 3. AFTER EXCAVATION TO THE DEPTHS REQUIRED, THE WALLS AND — SYSTEM REQUIRES 3' SEPERATION TO SEASONAL HIGH GROUNDWATER FLOOR AND RA K THE BED OR TRENCHES SHOULD BE CLEANED <C KED TO ACHIEVE AN EVEN SURFACE AND TO LOOSEN Z — TEST PIT SHOWS 3' FROM EXISTING GRADE TO MOTTLING — THEREFORE SMEARED SECTIONS OF TRENCH. SYSTEM WILL BE SHALLOW SYSTEM WITH FILL REQUIRED TO COVER BED. — STRIP EXISTING TOPSOIL AND FILL AREA WITH FINE LOAMY SAND (PERC. RATE 4. PLACEMENT CRUSHED STONE, PERFORATED PIPE AN IL FABRIC SHALLLL OF 5 TO 10 MINUTES) TO ELEVATION REQUIRED TO MAINTAIN BOTTOM OF EXERCISED TO AVOID BE SHOWN, AND CARE SHALL BE D INCLUSION OF FINE GRAINED SOILS AND BED LEVEL AT MIN. 3' ABOVE MOTTLING. OTHER WASTE MATERIAL IN THE STONE AND PIPE. Date' AM 24o US 5. THE PIPE SHOULD BE LAID AT THE GRADES AND TO THE SEWAGE PUMP USE GOULDS EFFLUENT PUMP MODEL 3885WE03L RELATIONSHIPS SHOWN ON THIS DRAWING, MAINTAINING STRAIGHT — SIZE DOSE TO FILL 100% OF THE DISTRIBUTION PIPING = 62 GAL CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS — USING 4 FT DIAMETER MANHOLE NEED PUMPDOWN = 8 INCHES OR OTHER UNSUITABLE CONDITIONS. THE PIPE SHALL BE LAID . — WITH THE HOLES DOWN IN ALL CASES. USE STANDARD GOULDS PUMP PACKAGE WITH FLOAT CONTROLS AND HIGH LEVEL ALARM. 6. ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL I AND TO DIVERT SURFACE RUNOFF FROM ADJACENT AREAS AWAY FROM THE DISPOSAL FIELD. 7. NO PART OF THE DISPOSAL SYSTEM SHALL BE INSTALLED UNDER DRIVEWAYS. 80ale AS NOTM 4901 '7 &*ET2OF2