Loading...
blower door resultsTesting Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:26 Alessia Address:26 Alessia Dr Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.277735 Longitude: -73.722608 Timestamp: 2021-04-28 14:28:33 Customer Information: Name:Cerrone Builders Address: Measured Leakage:987.2 CFM50 Test ID:26 Alesia Purpose of Test:RESNET Multi-Pt Env. Leakage Measured ACH50:2.24 (+/- 1.4%)Effective Leakage Area: 51.0 in² Building Volume:26,460.0 ft³Enclosure Surface Area: 3,024.0 ft² Coefficient (C):70.4 (+/- 6.3%)Exponent (n): 0.675 (+/- 0.018) Correlation Coefficient:0.99989 Test Standard:RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 62 °F Altitude: 412.0 ft Outdoor Temp: 49 °F Time Average Period: 10 seconds Test Date and Time:2021-04-29 08:39:05 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -0.4 -60.0 -60.2 -59.8 -39.1 1,135.6 Ring A -48.0 -47.7 -47.3 -28.6 975.6 Ring A -35.0 -34.3 -33.9 -176.4 787.2 Ring B -23.0 -24.4 -24.0 -108.7 619.2 Ring B -10.0 -12.0 -11.7 -40.1 377.8 Ring B Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3173 Custom Calibration Date: 2021-02-10 Pressure Gauge:DG1000 Serial #: 5193 Calibration Date: 2020-01-16 Deviations from Standard: None Comments: None Envelope Leakage Test Page 2 of 2Report by TEC Auto Test 1.7.3 (91), © 2020 The Energy Conservatory, Inc.