Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2004-504
TOWN OF QUEENSBURY 742 BayRoad,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20040504 Date Issued: Tuesday, July 07, 2009 This is to certify that work requested to be done as shown-by Permit Number P20040504' has been completed. Location: 5 JACQUELINE Dr Tax Map Number. 523400-295-006-0001-028-000-0000 Owner- DEXTER JENKINS Applicant: DEXTER JENKINS This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBLIRY Issuance of this Certificate of Occupancy DOES NOT relieve the fd. property owner of the responsibility for compliance with Site Plan " v P �J Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. d^ r. - \ TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 i Community Development-Building&Codes (518) 761-8256 1 BUILDING PERMIT Permit Number: P20040504 Application Number: A20040504 Tax Map No: 523400-295-006-0001-028-000-0000 Permission is hereby granted to: DEXTER JF,NKTNS For property located at: 5 JACQUELINE Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: DEXTER JENKINS ROBIN ROSE-JENKINS Residential Addition $5,000.00 Total Value $5,000.00 5 JACQUELINE Dr QUEENSBURY, NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2004-504 170 SQ FT RESIDENTIAL BASEMENT ADDITION .$75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday, July 07, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Qu::; ury befor a expiration Dated at the b dnesday, July 07, 2004 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Building Permit Application Town of Queensbury—Dept of Community Development,742 Bay Road,-Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No, 0 LI"S O No inspection will be made until applicant has received a Foe Paid $. -) .C,(� valid building permit. All applicants' spaces on this Rec.Fee Paid $ application must be completed and must appear on the Reviewed By. application form. Applicant:�� 3' K I I Owner: _j�r�x,�V L,9 i to rJ K ii�S Address: 5- J XaL fZ Address: Phone#(S=s ) L( - 6 7 37 Phone#(,) Property Location: Lot Number: / House Numbers/ Subdivision Name: L-&7tt�b L—Si• Tax Map Number: -5SZ3 ,Q,_67` '°0Q°0eZ 'a � W o New Building: residence /commercial 'Estimated Market Value of Constructio . $—:ez� ;rd, Addition: residence/ commercial If an Addition,what will use of new addition be? 0 Alteration: residence/ commercial 0 No change to exterior size: residence/com'1 S � � Cl Other work(describe ) Check Occupancylnformation 1' Floor 27Floor Other floor Total Below sq.ft. sq.ft, sq.It. Square Feet o Single fin&y dwelling v Two family dwelling e Townhouse o Multifamily dwelling #of units o Office o Mercantile o Maaufactutin 0 1 oar detached garage 0 2 oar detached L=ge 0 3 car detached garage 0 1 oar Attached garage 2 oar attached garage 0 3 car attached garage o Storage building- TOWN OF UEENSBURY commercial o Storage building- residential o Other What is the proposed height of the structure. feet inches Will any second-hand or ungraded lumber be used? If so,for what? e-o��em: electric/ oil / gas/wood /forced hot air! baseboard/other: NumYeef of Erenr"r.,�to be installed Number of Woodstoyes to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder Plumber Mason Electrician Declaration; please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Vwe shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or D r of Building and Codes,an js Built Survey by a licensed surveyor;drawn to scale,showing actual location of all na on. Signature: + owner,owner's agent,architect,contractor Queensbury Building.�k Code Enforcement - Residentie Final pection Office No. (518)761-8256 Arrive: m art: a m Date Inspection request received: Inspector's Initi NAME: C I= tiL),4) PE IT#: p LOCATION: _--� ���JC 1 F L—► K')F f)R x F DA E: TYPE OF STRUCTURE: Yes No N/A 4° Building Number Address visible from road Chimney Height/"B°Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs decks patios more than 30 inches above grade, Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall InteriorlExterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off ex osed/regulator 18 inches above grade Al�t ,� ®i�> Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safL-ty glazing Interior Smoke Detectors I Carbon Monoxide Detectors Every level: Every Bedroom: Outside every.bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'/:"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pie Bonding _ As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if re aired L- Okay to issue C/C or C 10 Tem ora ermanent L:\Building&Codes Forms\Building&Codes\lnspecfon FormsWesidential Final Inspection Forrn_revised_100405.doc;Revised January 7,2008;Revised 6/26/08 L1-t- I V--7m H L-D r-%i l Queensbury Building & Code Enforcement - Residential Final specti®n � Office No. (518)761-8256 Arrive: '— epa �� a Date Inspection request received: Inspector's Initials: f , NAME: in /��{ LOCATION: DATE. — TYPE OF STRUCTURE: • &— I—Oct - Col�lrrrerr>s�• Yes No NIA � 4° BuildingNumber Address visible from road �� ChimneyHeight/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch PlumbingVent through roof minimum 6 inches 1 EO 1 of\ C�I,OG�Pc�T� Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wail Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/rea/ulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior'Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents ` Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site 'i,Zt- \t�Y l;>uEQ Oil Furnace shut-off at entrance to furnace area _ Fumace/Hot Water Heater operating 1 Low water shut-off boiler Relief Valves installed/Heat Trapj Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'/2"Gypsum ' Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/,hour fire door/door closer Duct work Sealed properlyp� Gas Logs in Sealed or Glass Enclosure Final ElectrSurvey Plot � Final SurvePlot Plan `— Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if re uired Okay to issue C I C or C 10 Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008; Revised 6/26/08 Queensbury Building & Code Enforcement m Residential Fin I I ection Office No. (518) 761-8256 Arrive: a /p e : [n-zj> and Date Inspection requees-t�rreec-eived: Inspector's Initials: NAME: �l F A>V� t IJ _ (SIT#: H --5©A LOCATION: �� c�CI�U��\lJ� ATE: K-�-l-©9 TYPE OF STRUCTURE: Yes No N/A 4° Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs decks,patios more than 30 inches above grade,` Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches \A N 7-0 )�i Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backu : Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents; Bathroom Fans,if no window Plumbing fixtures i Foundation insulation/Insulation Certification ? CZ EM tJ1.)E Floor truss,draft stopping finished basement 1,000 s .ft. 11J Cat�, �� 1 �bTR�L 1� Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site 6oX- R R-zA Oil Furnace shut-off at entrance to furnace area bTL100EQ �t�-S. REvv►o Fumace/Hot Water Heater operating Low water shut-off boiler U- FF fl , v � t p0 t Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'/"Gypsum WAL- "LYb-�- BE- CZ\V-Z Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical ���� Final Survey Plot Plan Arc Fault Breaker in Bedrooms �k�-- Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Forrn_revised_100405.doc;Revised January 7,2008;Revised 6126/08 Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: ie Date Inspection request received: InspectNAME: (�S LOCATION: TYPE OF STRUCTURE: C®o�ornents- j Yes No WA • 4" Buildiffl Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Dr� Fresh Air Intake �� `'L 3 inch Plumbing Vent through roof minimum 6 inches �L� 1�/� `�� Roof Complete/Exterior Finish Complete / / Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck;porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off eVosed/regulator 18 inches above grade 1` Interior privacy/trim/doors/main entrance 36 inches '�Lv Bathroom/Kitchen watertight Safety glazing/Window in stairwells safe glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: ` Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area N\Az— '3 Crawl Spaces'18 inch x 24 inch access, 1 sq.ft:150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation �a 1 Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency mess below grade Gas Furnace shut-oft within 30 feet or within line of site l� 1 Oil Furnace shut-off at entrance to furnace area �n r Fumace/Hot Water Heater operating Low water shut-off boiler x'�1 Relief Valve(s)installed/Heat Trap/Water Temp 110 O Enclosed Stairs Sheetrock Underside minimum'/�Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed pro Gas Logs in Sealed or Glass Enclosure Final Electrical ` 1 Final Surve Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding .� Built Septic stem/Sewer Dept. Inspection Sticker Si Site Plan /Variance required Flood Plain Certification,if r uired Okay to issue C/C or C 10 1 Tem ra /Permanent LABuilding&Codes Forms\Building&CodesUnspection Forms\Residential Final inspection Form_revised_100405.doc,Revised January 7,2008 Queensbury Building & Code Enforcement - Reside Inspection Office No. (518)761-8256 Arrive: � 1�� p p a pm Date Inspection request received: Inspector's Initial NAME: tL3 E T M S_ LOCATION: ti (!DA : TYPE OF STRUCTURE: Comments Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more 1 Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers �-TC-_� co�, L OIS Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches i��t Bathroom/Kitchen watertight Safe lzin /Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: 7j�u ' Outside every bedroom area: Inter Connected: Batte .backu ��� \ Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft. vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''/2"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/1/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required / Flood Plain Certification,if required Okay to issue C/C or C/O [Temporary/Permanent J t L:\Building&Codes Forms\Building&CodesUnspection Forms' ial Fina�nspection Form revised_100405.doc Queensbury Building & Code Enforcement - Re ntial final Inspection Office No. (518)761-8256 Arrive: am/p, m 1 Date Inspection request received: — Inspector's Initia s: NAME: fry RMIT##: LOCATION: _ r p ATE: TYPE OF STRUCTURE: a - a Comments Y N N/A Chimne •Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Com lete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in, or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers F: Z, Enclosed Stairs Sheetrock Underside minimum %2" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss, draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&CodesUnspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 PROJECT DESCRIPTION: STANDARD ARCHITECTURAL ABBREVIATIONS ADDITION OF UNHEATED BASEMENT SPACE TO EXISTING HOUSE. ACT ACCOUSTICAL CEILING TILE INSUL INSULATION FULL FOUNDATION & DECKING DESIGNED FOR POTENTIAL AFF ABOVE FINISH FLOOR JST JOIST FUTURE UPGRADE TO PORCH. ALUM ALUMINUM KS KNEE SPACE 8 JUNE 2004 PROJECT LOCATION: ANOD ANODIZED LVL LAMINATED VENEER LUMBER BLDG BUILDING MATL MATERIAL 5 JACQUELINE DRIVE CAF COMPUTER ACCESS FLOORING MAX MAXIMUM LEHLAND ESTATES CL CENTER LINE MECH MECHANICAL ° QUEENSBURY, NY 12804 CB CATCH BASIN MBL MARBLE > CJT CONTROL JOINT MFR MANUFACTURER � TAX # 295.6-1 -28 CLG CEILING MIN MINIMUM RELATED SURVEY BY DICKINSON ASSOCIATES, NOVEMBER 3, 1987 CMU CONCRETE MASONRY UNIT MO MASONRY OPENING ADDITIONAL CONDITIONS SHOWN ARE BASED ON DOCUMENTS ON CONIC CONCRETE MTD MOUNTED TOWN FILE FOR POOL INSTALLATION AND ON SITE VERIFICATION. CONT CONTINUOUS MTL METAL NIC NOT IN CONTRACT I W F-- CPT CARPET W CT CERAMIC TILE NOM NOMINAL > W JACQUELINE DRIVE CTR CENTER OC ON CENTER 0 _ DF DRINKING FOUNTAIN OD OUTSIDE DIAMETER U (n EF EXHAUST FAN OH OVERHEAD EIFS EXTERIOR INSULATION & FINISH OPP OPPOSITE OF EFS EXTERIOR FINISH SYSTEM OPNG OPENING ELECTRIC EGS EXTERIOR GYPSUM SHEATHING P LAM PLASTIC LAMINATE 1 ELEC ELECTRICAL PLY PLYWOOD z 53 —1 5„ ELEV ELEVATION POLY POLYETHYLENE 0 FRONT YARD I ETR EXISTING TO REMAIN P 0 T PRESSURE TREATED •� EXIST EXISTING QT QUARRY TILE I EXP JT EXPANSION JOINT RD ROOF DRAIN z 5'-0 1" I DRIVEWAY EXT EXTERIOR REC RECOMMENDED 75 FDN FOUNDATION REINF REINFORCED 0 }- STONE RETAINING FE FIRE EXTINGUISHER REQ'D REQUIRED I-1- z WALL FEC FIRE EXTINGUISHER & CABINET RM ROOM J „ EXISTING HOUSE I 28 —116 FIN FINISH RO ROUGH OPENING 15'-716 SIDE YARD FLR FLOOR RUB RUBBER LL_ C�d SIDE YARDIIiIIIII PROPOSED DECK FTG FOOTING SD SMOKE DETECTOR \ ADDITION GA GUAGE SF SQUARE FEET Q j- GALV GALVANIZED SLR SEALER -}-' Q) r- SHED GC GENERAL CONTRACTOR STL STEEL U Q) D - GWB GYPSUM WALLBOARD SV SANITARY VENT LW i) 0 l CURRENT DECK HDWD HARDWOOD T&G TONGUE & GROOVE 0 __ POOL HGT HEIGHT TO TOP OF --- ---------------------------- FENCE HM HOLLOW METAL TYP TYPICAL L _______________________ _ __ - ----- ----- HORIZ HORIZONTAL VAR VARIES -- -----~ - -- EXISTING SEPTIC --- -------- -- HR HOUR VCT VINYL COMPOSITION TILE LANDSCAPING WALL z ID INSIDE DIMENSION VERT VERTICAL cn IG INSULATING GLASS WWM WELDED WIRE MESH TOWN OF QUEENSBURY BUILDING DEPARTMENT o L Based on our limited examination, 10 5'—7 L I U comppliance with our comments shall 1 not be construed as indicating the BACK YARD cn CODE COMPLIANCE plans and specifications are in full I a� compliance with the Building Codes I a� of New York State. i I TO THE BEST OF OUR PROFESSIONAL JUDGEMENT, THESE PLANS O ARE IN COMPLIANCE WITH THE RESIDENTIAL BUILDING CODE OF NEW YORK STATE. = WOODS, , ,� THE BUILDING IS CLASSIFIED AS FOLLOWS: m cI6URY �UILDIIW GENERAL CLASSIFICATION BY OCCUPANCY OR USE ( BLDG CODE SECTION 302) _j U EP . SITE MAP "R-3"- RESIDENTIAL AND RESIDENTIAL CODE R 101 .2 REVIEWED B SCALE: 1" = 30'- 0" DATE CLASSIFICATION BY CONSTRUCTION TYPE (BLDG CODE SECTION 602.5) TYPE Vb F— Q GENERAL NOTES: -NEW BASEMENT SPACE DESIGNED AS UNHEATED-NO VENTILATION IN ROOF AREA USE OF THE CONSTRUCTION DOCUMENTS ASSOCIATED WITH THIS PROJECT —ALL FRAMING LUMBER TO BE GRADE NO 2. OR BETTER WITHOUT CONSULTANT KNOWLEDGE IS PROHIBITED. THESE DRAWINGS ARE —ALL CONCRETE TO BE AT LEAST 2500 PSI COPYEINSTRUMENTS OF SERVICE AND MAY NOT BE ALTERED, REPRODUCED, _ALL CONSTRUCTION TO CONFORM TO THE LATEST EDITION OF NYS & LOCAL CODES COPI D R USED F RCONSTRUCTION IFUTURE UPGRADE FROM FLAT ROOF TO DECK WOULD REQUIRE THE 0 0 W TROUT WRITTEN PERMISSION FROM TANYA L.B.BRUNO, ARCHITECTURAL PLANNING CONSULTANT. INSTALLATION OF RAILINGS & GUARDS PER SECTION R316. N = 0 } Cry EXIST. GARAGE WALL 8 JUNE 2004 FLAT ROOF— 5/4" X4" T&G SLOPED POTENTIAL 1/4" PER FT AWAY FROM HOUSE A _o FUTURE RUB RFING MEMBRANE 2 DECK 3/4" PLY W/ ROOFING FELT 9 —2 18'-6„ 10, 2X12 RIM JOIST 2 X 12 FLR JOISTS @ 16" O.C. 2) 2X10 P.T. SILL W/ 1/2" x 10" A.B. @ 6" O.C. m SET WITHIN 12" CORNER (typ) THRU 2" WASHERS, 1 >> O 4'-8- EXISTING GARAGE WALL Z _ BOLT SET 7" min. INTO CMU. SEAL SILL. 2 d Q U W 7>_8 ° SLOPE GRADE FROM FDN. MIN 6" WITHIN 10' - CIS a JOIST HANGERS BOLTED TO 2x12 NAILER 0 12'-1 " � z NEW o c d \ co BSMT 1 „ Q 00 - 1" RIGID INSUL. 10 -54 0 N d ° a 10" CMU WALL W/#3 REBAR, VERT. 0 � z d WATERPROOFING ON EXT. OF WALL ' 8" J ° 19" X 8" CONT. CONC. FTG. W/2 #4 REBAR CONT. H ROOF DECKING PLAN \C�6 • (OFF-CTR PLACEMENT IS AS-BUILT COND.) c SCALE: 1/4" = 1'- 0" X N V! �, 4" SLAB W/ WWM W 0 C� A 2 6 mil. POLY VAPOR BARRIER 1 7'_g" r r.SECTION .. : : A 4"-6" min. GRAVEL BED - z 2 � SCALE: 1/2" = 1'- 0" UNDISTURBED EARTH OR COMPACT TO 95 PROCTOR 4'-0" EXISTING GARAGE WALL cn >; o FTG IS AS—BUILT SITUATIO U EXISTING FDN WALL HOLD FDN DOWN TO ALLOW 'MU WALL ADJUSTED TO FOR 4" CONC. SLAB TO BE 90' ANGLE TO EXISTING WALL POURED OVER I 0 1'-7" FTG 12,_1 „ 12'—8 WIDTH FTG DIM. 2i� 11 " 1" NOSING OVERLAPPED i BLOCK OUT FOR ! — SIDES OF STEPS CONTAINED WINDOW (24" DOWN m >, WITH LANDSCAPING BLOCK WALLS FROM T.O. WALL) m -� c- d ° 12" 3 —4 _i U L RUN o +J CD ---- ---- -----J �3 10'—51 E�'; 3�, 14" X4' X2" SLATE PAVER ° —�16 8" RISE - ---------------- - ------ -------------------- - 4, 1 1 „ 2, 8" 5' 03" 4 4 d 4 11 -10" COMPACTED ROCK BASE ' -12'-313" FTG DIM. LANDSCAPING BLOCK 18 X12 X6 z - 16 _. . 18'-6" OVERALL WIDT B LANDSCAPING STAIR SECTION FOUNDATION PLAN W 3 SCALE: 1/2" = 1'— 0" SCALE: 1/4" = 1'— 0" = O Cf) N