Loading...
2004-514 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20040514 Date Issued: Tuesday, July 26, 2005 This is to certify that work requested to be done as shown by Permit Number P20040514 has been completed. Tax Map Number: 523400-308-009-0001-001-000-0000 Location: 301 WEST MT. Rd Owner: FRED &ARTHUR HULL Applicant: FRED &ARTHUR HULL This structure may be occupied as a: Deck By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. T TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040514 Application Number: A20040514 Tax Map No: 523400-308-009-0001-001-000-0000 Permission is hereby granted to: FRF,D & ARTHT TR HT TT J, For property located at: 301 WEST MT. Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: FRED & ARTHUR HULL 301 WEST MT. Rd Deck $2,500.00 Total Value $2,500.00 QUEENSBURY, NY 12804 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2004-514 510 SQ FT DECK $51.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday, July 09, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tor ueens r d , July 09, 2004 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Porch, Deck, Dock, or Boathouse Permit Application Town of Queensbury—Dept of Community Development, 742 Bay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. No Permit File No. -CS/ inspection will be made until applicant has received a valid Fee Paid $ d building permit. All applicants'spaces on this application must be Reviewed By: completed and must appear on the application form Applicant: l Owner: /T7par A/0 Address: , Address: Phone# Phone#O - !a Email Address: halloo2d COyu Email Address: u//6-o ircy, Person Responsible for Supervision of Work as Regards to Building Codes: Name Address: /"iy,/Ili Phone Property Location: Lot Number: -- / House NumberanL_/���� 9�& Ad t Subdivision Name: Tax Map Number: 3a R,. 4 —! Estimated Market Value of Construction: $ ❑ Porch Deck ❑ Dock RECEIVE® ❑ Boathouse ❑ Other work(describe Size of structure to be built 6—/n square feet J U L O'2 2004 TOWN OF QUEENSBURY BUILDING AND CODE Submit along with this application: 1. Two plot plans drawn to scale,preferably using a survey map,, Indicate proposed structure showing setback dimensions from all property lines. Show location of water supply and location and configuration of septic disposal area. 2. Two sets of structural drawings. Indicate size of posts or studs, floor joists, decking or flooring material to be used. Show how the porch or deck will be fastened to the building. If a roof will be constructed,indicate the size of posts or studs,roof rafter spacing and span. Indicate type of roof: sloped, flat, shed, or other. Indicate the type of material being used for the roof. Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all visions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed w1pr s�all be complied with,whether specified or noted;and that such work is authorized by the owner. 2�� Applicant's signature: _ Date: r /d L:\SueHemingway\Building.Permit.FORMS\Porch.Poreh.Permitdoe 8/13/02 revised per DH Queensbury Building & Code Enforcement - Residential Final Inspection Office No. 518 a 5 V /qq ( )761-8256 Arrive: am/pm Depart: 6V _ppm Date Inspection request received: Inspector's Initials: _A�kr) _ NAME: PERMIT#: LOCATION: 3(21 We4f/z, DATE: z/3 D TYPE OF STRUCTURE: ;DSO rGI _ �k _ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Co lete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more _ Guard at deck,porches 36 in, or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" Gypsum Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas.Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ 1 Garage fire roofing/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(he.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft. vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamWlBuilding&CodeslInspection FormslRes. Final Insp. form 2,docLast printed 2/12/04 Queensbury Building& Code Enforcement - Residential Finial Inspection Office No.(518)761-8256 Arrive: am/pm Depart:(D—Y—O—Qm Date Inspection request received: -7 5 O 5 Inspector's Initials: 4 l�// Ll NAME: (� PERMIT#: Q T S�l LOCATION: t DATE: TYPE OF STRUCTURE: Comments Y N . N/A Chimney Ht./"B"Vent/Direct Vent Location ,t Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks patios Guard at stairwell at 34 in. or more Guard at deck,porche2 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum ''/z" Gypsum Grade away from foundation 6 in.with 10 ft. r,.'. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: ! Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector _ Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grRde Basement stairs closed rise>4 inches Garage Floor Pitched Garage fire roofing/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in,x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24" access, 1 s . ft,-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent -7 L:\PamW\Building&Codes\lnspection Forrns\Res. Final Inso. form 2.docLast printed 2/12/04 West 340' RECEIVE . JUL 0 2 2004 TOWN QF QUEENSBURY BUILDING AND CODE 7OMtN �1 �` UILDINGDEPARTMENT. sln ©Ut limited.examination, fib �igRed►�ilit t1F comments shall � t 'e 'chi§It dedicating the - F ';s. 11� t are in full 111'. �''3titrYrr ` �ei►iii Codes ai co r o South " 28'7' North 02 , -oa a•� N ` �rz• - Arthur and Christine Hull's, Arthur and Christine Hull's. Property Property - 335UEL- BUI .DRNI EPA".. REVIEWED n� East '1" . 77 309' Scale 1 inch=75 feet es ou ntai n Ro Arthur and.Christine.Hull 301 Mest. Mountain Road '` South 16 96' 16. 39' O - 334'- . . N � East:. N West CD CL 16' 1 ...... 0..... . ...... ...... KeY Scale 12"Sono-Tube 1/4"= 1 foot ■ 4"x 4"post sunk 4.5'into ground 1/2"x 8"Lag Bolt 2"x 10".Joist ❑ 6"x 6"Post 1/2 " x 8".lag bolts — — - ------ - — = - i.. I. I UII I t 11' 2" , I ----� 6 inch decking . 3.25" cap rail 4 x 4" posts 211'x 1.51' x 36" spindles 4' 4" spacing — 6" x 6" post 0'�joists.2"'x 1 is r" 3/8" x 10".car i rage.bolts ,W1 k . 5211 ,; Cement Pylons 52° 52 l 4 1211 il fi Scale:'1/4'inch = 1 foot: View From East Side Scale 1/4 inch = 1 foot, sti Str tur xi nQ on i 39° 6..inch decking 4".rail cap i LL [1- L I 1..� _iLL 29':3" 2"x 10"joists, 2„x 1.5"'x 36" spindles 4 spacing 41 .x 4".posts 611 X.6" posts 52" cement pylons View From;South.Side' �' . .611 X '6" post Nails -77 Anchor f,+,+�T� LT SX f.,. YON 8 inch bolt � /�11 V 1 O11 joist' . ' r :.r.-x<.rrr:.r.;?.%.Y:.:.Y.-:?.:.r.;?.;r.;p.;z;,.�3',zr:.r.•:;. . . . . '�F.C^ Y?.;.Y:,.;Y,.:.Y-':�:.Yd?'xY:p:.Y:�;Y:.: , I ?;Y:�::Y�<.Y?,,Y?.:.Yt+,:� . . . . R'P . T_j.yT:"s.•..T_¢.yT::i...T:=i`,Y_¢.yT:•?�'•.Y:>:<.X';Y;:,,.;X�?- 52" L { f f ji`T YT.ET t X T T. XT X7 YTTT Concrete pylon - . . i?:;Y?:.c;?.;.Y;;:Y;3-.z:,.;x:?.:.Y..: '211 x.1.0. zinc coated T!�Y-^�Y EY.E. .FYYef`Y metal joist hanger: . . . . . . . ' f_°,:;:,.:.T.'%Tr'.:X:s..;T?'aT?':.Y:s.;Y?".T?`+X:'•Yi+.. :�:;.Y.e.;.T:.�o.T.a:.T..:.T:;T.r_?. f f f f t E ->rr fr,fT•,{ C:j'%.Y,;,..�?.%X..y?o.T::j';?;_s%T.�,:>T..•:�'r.7:.?.;T..,.-.T'i?e.1:,.' __ lSl: Y•„:.Y='-Y:.-.Y=>.%„.Y„`.Y�.%Y=•y<.:Y'. Y F'rf's:�'s? ' r T T T?Y:�;Yii:tir%T.-:i :.i4Y-(p'T4 T sit ix Y—Y' T.:<Y:?' f z!T�. T:. Y".-.Y. Y 7.2l ihL.G=.tt:F.IC'4ii.16%^:�r`'.�ii�...F::..-':iiri� ..:'i TySC:: i�C..•�R:w>Lr:,.��.:ni.�'=:i ' _: T' T:?T.?kS T::Y•'?T�.,+,.':X1?T-%T .T-Y _ . ':rSu'=::ii�'tL""i'c:-^..F:riti'^f C•^.:a(".7`t£i'^.C:: 12". Scaler 1 1/2 inches = 1 foot Stair Construction For Both 48" and 39 " Width Stairs 21' x 10 Joist '3 2".x 12"stringers ol 1" depth joist hangers .rise 2 2" x 51/2",boards