Loading...
2004-524 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CE-11.7vLIFICATEOF OCCUPANCY Permit Number: P20040524 Date Issued: Friday; August 12, 2005 This is to certify that work requested to be done as shown by Permit Number P20040524 has been completed. Tax Map,Number: 523400-301-005-0001-035-000-0000 Location: 14 QUEENS Ln Owner: PAUL &HOLLIS SCHULZE Applicant: PAUL & HOLLIS SCHULZE This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with.Site Plan, 4V Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040524 Application Number: A20040524 Tax Map No: 523400-301-005-0001-035-000-0000 Permission is hereby granted to: PAT TT,&T40T,T,TS SC MJT,7,F, For property located at: 14 QUEENS Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. . Type of Construction Value Owner Address: PAUL&HOLLIS SCHULZE Residential Addition $15,000.00 14 QUEENS Ln Total Value $15,000.00 QUEENSBURY, NY 12804 Contractor or Builder's Name /Address Electrical Inspection Agency WILLIAM SCOTT WEST 23 EASY St NY 12804-0000 Plans&Specifications 2004-524 232 SQ FT RESIDENTIAL ADDITION $75.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,August 12, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of QueensDu before the expiration date.) Dated at the To of Q 6e b T r gust 12, 2004 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Building Permit Application Town of Queensbury-Dept of Community Development,742 Bay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No., q-Sa-Y No inspection will be made until applicant has received a Fee Paid valid building permit. All applicants' spaces on this Rea.Fee Paid $ application must be completed and must appear on the Reviewed By: application form. Applicant: lob rl P had r-(3 (,t s( Owner: Pa c C Address: A; c_0 g C, s Address: /�f (�}a pf,n A IlAa4 Y Phone#(, ) 3- Phone#Q-[9 7 u.s"- C ERsV Property Location: Lot dumber: q / House Number N I Subdivision Name- Es-k�e� kr-ka,, Tax Map Number: 3o1. 5-1- 3.5 R' ' n.,i•- to o New Building: residence /commercial 'Estimated Market Value of Construction: $ /40_ Addition: residence/ commercial If an Addition,what will use of new addition be? Alteration: residence/ commercial O No change to exterior size: residence/com'1 m Other work(describe ) Check Occupancylnformation 1 Floor 2° Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet Single family dwelling 2 3 2 . m Two family dwelling m Townhouse o . Multifamily dwelling #of twits o Office o Mercantile 0 Manufacturin 0 1 car detached g=ge 0 2 car detached maga 0 3 car detached garage 0 1 oar attaehod garage 0 2 oar attached garage 0 3 car attached garage v Storage building- OF E commercial SOWN p1NG Alp COD o Storage building- residenthl 0 OtherK'' r What is the proposed height of the structure ,feet inches ,'_.•. Will any second band or ungraded lumber be used? If so,for what? X1 n Type of Heating System: electric/ oil / gas wood / creed hot air baseboard/other: 1" Number of Fireylaces to be installed Number of Woodstova to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name Address- Phone Number rh Buildert^a.9 Lrs1 7�3 4��L3 Plumber ArPir�e Mason Electrician f ' Decl=tio please sign below after you have carethlly read the statement: To the best of my knowledge the statements contained in this application,together with the pleas and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Uwe shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning 4, Administrator or Director of Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual location of all new construction ,�}S Sr.�82ure• f����i�r%i����/-J� orraar orvd�r.'s�aB�vs s�c611�C/CD�b�GtOl P Check Residential Plan Review: One&Two Family Dwellings Y/N/N/A %/ (2)Full sets of plans �" Over 1,500 sq. ft.—Stamped / Design Loads On Plan '90-Wind- Floor Loads.40 psf 7- C7 ound Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size 4 C` Door Schedule/Main Entrance 36"Door r Emergency Escape Or Bedrooms and Habitable Space ,r Above/Below grade,5.7 sq.ft. \ Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofmg/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6"Drop in 10' Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6 8'All Stairs 36"Width Stair Run and Rise' ` Winder Run and Rise a' Spiral Not Allowed From 2'd Story , Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Y Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results,if required Septic To Well Or Water Line Separation All Paperwork Signed WINDOW SCHEDULE Job Site/Address: /y Date: 7 )2-3 169 Owner: �Ccr�1t� Application No. z o6 Y - ZY Window Window Window Unit or Rough Rough SQ.FT. SQ.FT SQ.FT. Clear Clear Special Hardware Number,or Manufaturor Model/Type Stock Openin Opening Glass/Vis Egress/Cle Opening Opening or Instructions Letter on Name Numbe g Height ible Vent ar Width In Height Plan Call Width Light Opening Inches In Inches Size rw 2vLt& 2- �s I �/ z3 x L3�?� 1 -1/0() %-7/5&Ji' z 3 izs 1 7 -v ciT%fJ CYXY 30(08 S-6 �— (D,(PSSr f �p & ncc�cSe'� s, �Cf cvsc 7 /-7 "z Y•S7sF d l y 9./ysF c � �Z �8L t►�{"z (o(y7012 � a0 pub' L r 133y.Ozs lr H u Z°O I.2, Z Example Entry A Andersen Narroline 3062 3' 2 6'5 % 15.30 8.36 6.01 34 24 15/35" Tempered Double 1/3" 11/16 Glazing Hun CADocuments and Settings\Sue\Local SettingMemp\Window Schedule.doc Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/pm a art: I • I Sm/pm Date Inspection request received: Inspector's Initials: _ t NAME: PERMIT#: LOCATION: ye-4, S DATE: _ TYPE OF STRUCTURE: ; _ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Com lete ---- Guard 30 in. or more @ stairs, decks, atios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more xterior Finish Complete nterior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum '/" Gypsum Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector _ Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss, draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/3/<hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, I s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required ka to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\lnsvection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection J _ Office No.(518)761-8256 / Arrive: am/ m epart: �./dm/pm Date Inspection request received: �3k Inspector's Initials: NAME: C-,y(it.✓� Z-z (4 ('_S PERMIT#: O c t—� LOCATION: V, ,V e ,4- DATE: s (> TYPE OF STRUCTURE: _ _ Comments Y N N/ Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs, decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors VL�D Interior Handrails stairs 2 or more risers 1 I Enclosed Stairs Sheetrock Underside minimum '/" Gypsum v� Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tern 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector _ Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"qccess, I s . ft.-150 s . ft. vents Building No./Address y4sible flom r Final Electrical f Site Plan /Variance r uire Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required )tj Okay to issue C/C or C/U Temporary/Permanent L:\PamW\Building&Codes\Inspection Fornis\Res. Final Insn. form 2.docLast printed 2/12/04 Rough Plumbing / Insulation Inspection Report Office No. (51 8) 761-8256 Date Inspection request received: ��L Queensbury Building& Code Enforcement Arrive: am/pm �epart: e m/p 742 Bay Road, Queensbury,NY 12804 Inspector's Initia NAME: 'GH 11 I Z-c-- . 5 C 0-r 7- 5 PERMIT #: 200 a LOCATION: j t/4 0 VJ .INSPECT ON: 2 Z oc TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2, R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping vV� � Pz—� Cooper Commercial Cooper, CPVC,Pex One :and Two-Family sulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: LASueHemingway\Building.Codes.Inspection.FORM S\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insulation Inspection Deport Office No. (518) 761-8256 Date Inspection request received: /0- Queensbury Building&Code Enforcement Arrive: am/ part: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initial NAME: `-at"e 4_eL PERMIT #: _ LOCATION: au eg - INSPECT ON: a o TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2, R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Coo er, CPVC,Pex One and Two-Family . nsu /_Residential Check/Commercial Check Pro"er-,-fie " Attic Vent uct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace uct work:sealed-properly/No duct tape :J -�%0 COMMENTS: L:\SueHemingway\13uilding.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: aIn/p art: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: -,ff, NAME: TnjAP4W-b-'10j PERMIT#: 00 LOCATION: INSPECT ON: 0 U 0:003 I m TYPE OF STRUCTURL Y N N/A COMMENTS V, Framing 'Tack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall ;I F"re separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection reque t received: Queensbury Building&Code Enforcement Arrive: am/p Depart: �am/pm 742 Bay Rd., Queensbury,.NY 12804 Inspector's Initials: NAME: G L%v PERMIT#: Q LOCATION: _ G�r-9S L INSPECT ON: TYPE OF STRUCTURE:; Comments Y N,.-' N/A Footings Piers r' Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placeme t of the concrete. Materials for this pu_pr ose on site. Foundation/Wallpour \ / Reinforcement in Place Foundation Dampproofing \ Foundation/Waterproofing Type of Dampproofing/Waterproof mg Footing Drain Daylight or Sump/ Footing Drain Stone: 12 inch width 6 inches above footing/ 6 mil poly for wet aF• as under slab Backfill Approval umbing Under Slab PVC/Cast/Copper Foundatioia-Tn sulation Interior Exteri _ R- Rough Grade 6 inch drop within t. L:\SucHcmingway\Building.Codcs.Inspection.FOIIMS\1'oundation Inspection Report.doc .January 28,200_ Foundation Inspection Report d ,w0lkv Office No. (518)761-8256 Date Inspection request received: + Queensbury Building&Code Enforcement Arrive: anv in Depart:—,, an-/pm 742 Bay Rd., Queensbttry,NY 12804 Inspector's Initials: NAME: _ _ / PERM, #: LOCATION: � _ INSPEC ON: TYPE OF STRUCTURE: Comments __ _--- Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. / Materials for this purpose on site. Foundation/W allpour Reinforcement in Place / Foundation Dampproofing / Foundation Waterproofing / e of I ;P-p'oofing/Watetprodf-ing Footing Drain Daylight or Sump Footing Drain Stone: j` 12 inch width 6 inches above footing 6 mil poly-for wet ar as under slab Backfilll°Approval .� Plumiiing Under Sla PVC/Cast/Copper Foundation Insufation Interior/Exterior R- Rough Grad� 6 inch drop within 10 ft. L:\SucHemingway\Building.Codcs.Inspection.FORMS\Foundation Inspection Report.doe January 28,2003 Foundation Inspection Report Office No. (518) 761-82.56 Date Inspection requ st received: Queensbury Building&Code Enforcement Arrive: am/p Depart: _' 0 am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials. NAME: GA_ Z—�e � 1'EIZMIT#: / LOCATION: k o INSPECT ON: TYPE. OF STRUCT RE: Comments otin gs _ Y N N/A Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Material_or_this pu�pr ose on site. Fou ion/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Bui Win g.Codes.Inspcction.FORMS\Foundation Inspection Report.doc January 28,2003 ! '77� Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: —f Queensbury Building&Code Enforcement Arrive: am/p Depart:C / �am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:(- � l ' Q � NAME: l5 Z-,— PERMIT — LOCATION: _� INSPECT ON: l 1�.1_=Zq TYPE OF STRUCTURE: S Comments _----- Y N N/A F otings i Piers Monolithic Slab Reinforcement in Place 2/, The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purr ose on site._ Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueBemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doe January 28,2003 Page 1 of 1 Main Identity From: "David Schulze" <david.schulze@dps-labs.com> EC E�VE To: "Paul & Holly Schulze*" <schulze4@adelphia.net> Sent: Tuesday, October 12, 2004 7:57 AM OCT 2 1 2004 Attach: Pauls-Phase1.pdf V � Subject: Revision T OVVN OF QUEENSBURY Hi Paul BUI!-DING FUND CODE -- Attached is the complete set of plans updated per the building inspectors request. Below is a JPG of the section showing the I-Joist in place This should be printable on your computer. Let me know if you need anything else. Corninuous Ridge'vknr 2x 10 Rafters 0 24.,00,. 102 Ridge Beam 1.`Nth Arspace,. 112 "Stieat 12 1F2"Gypsum tl1�v Fete: UUallboard typical walls and ceiling `30 2)W.Collar ties @ 4-0"oc" 1i}"R38 Fiberglass Batt $roil Poly eth lene\.6 or:Barrie - Fa. 1.'-0" f Y p - mat. -314 x 7-114 I ;M ro.lam Heade_f 1 , 1 Pine window seat � � a i r-_ DINING-ROOM: 3 R19 Fibergals Batt _ 8"R30 Fiberglass,Batt' i f Carpet 4,�:: ( 314"TS:G Subtloor glued and-screwed 514x6 PT Docking '2x6 Joist 0 16"oc- ` 2x6'Pressure Traated sill; 9.25"I•Joist 16' oc i6" Overheng PJascor'NJ925 oceggiv , ^?x2 L�dgetstnps 113'Anchor Bofts E'oc typ. 1 l - HATCHWAY WORKSHOP ° k3D00 Concrete Walls I and Footings tyP 3"tt3500 Concrete;Floor I '19s and piers to by 4R" v S tvil.Polyethylene l ade . . .. l,bpor .Bartier ." min and rest on .., _ .; fed or coriipac2ed,OaiG; r •r:c'[r:.ny-P"ti"� '�'Y .�:rP.;F;pr��;i;•�'�;,,•xylcp,�r...,.a5 L�_,u.:.,�'rr.,�'.:�.,a,�d'y-•nrc7: w :y.'l.%mar i:...y.:.t 5ryy;�. 61-'Compacted:Bank:Run Giauel' ' SC 6 l WPL 793 '�6 10/13/2004 �^^. - 1, J01s ( C VWVS� - �OS lbrr-11 I-n SprCTI :A. k ' 1 Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.6 Release 1 Data filename:Untitled.rck PROJECT TITLE: Schultz CITY:Glens Falls STATE:New York HDD:7635 CONSTRUCTION TYPE: Single Family WINDOW/WALL RATIO:0.19 DATE:08/12/04 DATE OF PLANS:August 12,2004 DESIGNER/CONTRACTOR: Scott West COMPLIANCE:Passes Maximum UA=61 Your Home UA=58 4.9%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U Factor UA Ceiling 1: Cathedral Ceiling(no attic) 233 38.0 0.0 6 Wall 1:Wood Frame, 16"o.c. 392 21.0 0.0 18 Window 1:Wood Frame:Double Pane with Low E 65 0.350 23 Door 1: Glass 9 0.340 3 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 233 30.0 0.0 8 Furnace 1:Forced Hot Air,78 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.6 Release 1(formerly 1VIECchecl and to comply with the mandatory requirements listed in the REScheckInspe'c/tiion Checklist. Builder/Designer a JLZAez,, �(.��� Date — Z 0 REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.6 Release 1 DATE:08/12/04 PROJECT TITLE: Schultz Bldg. Dept. Use I Ceilings: [ ] I 1. Ceiling 1:Cathedral Ceiling(no attic),R 38.0 cavity insulation Comments: I Above-Grade Walls: [ ] I 1. Wall 1:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: i Windows: [ ] 1. Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: I Doors: [ ] I 1. Door 1: Glass,U-factor:0.340 Comments: Floors: [ ] I 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation Comments: I Heating and Cooling Equipment: [ ] I 1. Furnace 1:Forced Hot Air,78 AFUE or higher Make and Model Number I Air Leakage: [ ] I Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. I Vapor Retarder: [ ] I Required on the warm-in-winter side of all non vented framed ceilings,walls,and floors. I Materials Identification: [ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] I Materials and equipment must be identified so that compliance can be determined. [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating I equipment must be provided. [ ] I Insulation R values and glazing U-factors must be clearly marked on the building plans or specifications. I Duct Insulation: [ ] I Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. I Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives), I mastic-plus-embedded-fabric,or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts I operating at less than 2 in.w.g.(500 Pa). [ ] I The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to I partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. I Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the I water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% I of the heating energy is from non-depletable sources. Pool pumps require a time clock. I Heating and Cooling Piping Insulation: [ l I HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the I levels in Table 2. ti Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pine Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temnerature LF) Up to 1" Un to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipe Fluid Temp. Insulation Thickness in Inches h P-ipe Sizes Piping S sY tem bus Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressurefremperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)