2004-530 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building &Codes .(518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number. P20040530 Date Issued: Wednesday, June 29, 2005
This is to certify that work requested to be done as shown by Permit Number P20040530
has been completed.
Tax Map Number. 523400-301-01370002-037-000-0000
Location: 43 ALGONQUIN Dr
Owner. JPEK DEVELOPMENT, INC.
Applicant: JPEK DEVELOPMENT, INC.
This structure maybe occupied as a:
Fireplace By Order of Town Board
is
Garage - 2 Cars Attached oWN o QUEENSBjJRX
Single Family Dwelling
Issuance of this Certificate of Occupancy DOES NOT relieve the
• property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
-r TOWN-OF QUEENSBURY
.742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development_Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20040530 Application Number: A20040530
Tax Map No: 523400-301-013-0002-037-000-0000
F
Permission is hereby granted to: TPEK DEV-F,T,OPMF,NT. TNC.
For property located at: 43 ALGONQUIN Dr
in the Town of Queensbury,to,construcfor pl'dc'e
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance.
Type of Construction Value
Owner Address: JPEK DEVELOPMENT, INC.
29 PERSHING Rd Fireplace
Garage-2 Cars Attached
QUEENSBURY,;NY 12804-0000 Single Family Dwelling $250,000.00
Total Value $250,000.00
r ' a
Contractor or Builder's Name /Address ! !, Electrical Inspection Agency
TPEK DEVELOPMENT_ INC.
29 PERSHING Rd
OTTEENSBURY_ NY 1280470000.,
Plans&Specifications
2004-530
2716 SQ FT SINGLE FAMILY DWELLING
$374.32 PERMIT FEE PAID-THIS'PERMIT EXPIRES: Friday, July 22, 2005
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the.Town of Queensbury before the expiration date.)
Dated at the T of Quee bury; ,h rsday, July 22, 2004
SIGNED BY fJ2 for the Town of Queensbury.
F
Director of Buildin &Co Enforcement
f
Building Permit Application
Town of Queensbury-Dept of Community Development,742 Bay Road,Queensbury,NY
(518)761-8256
A permit must be obtained before beginning construction. Permit File No. b L- S 0
No inspection will be made until applicant has received a Fee Paid. $171L. 0a
valid building permit. All applicants' spaces on this ` Rec.Fee Paid, $
application must be.completed and must appear on the Reviewed By:
application form.
' Applicant: -N-310JC-C;_ mr-ti7 Owner:
Address: Address: 9'1 5�
K IF&
Phone# Phone `t 56�
t✓RIC_
Property Location: Lot N ber: 149 / House Number
Subdivision Name:' 4 AESiryOWD Tax Map Number: 'SO I. 1 --DL`S
New Building: residence i commercial "Estimated Market Value of Construction: $9SO O 00
❑ Addition: residence/ commercial if an Addition,what will use of new addition be? "
❑ Alteration: residence/ commercial
❑ No change to exterior size: residence/com'l
o Other work(describe )
Check occupancyInformation 1' Floor 2° Floor other floor _ Total
Below . sq.ft. sq ft. sq.ft. Square Feet
Single fhmily dwelling _TT 1
o Two family dwelling
v Townhouse
❑ Multifamily dwelling
#of units
❑ Office
v Mercantile
o Maaufactutirl. .
0 1 car detached garage
0 2 car detached garage
0 3.car detached garage
a 1 car attached garage J U L 0 92004 '
1 2 oar attached garage
❑ 3 car attached garage
o Storage building- --
commercial
❑ Storage.building-
residential
o Other
what is the proposed height of the structures feet inches
Will any second-hand or ungraded lumber be used? If so,for what? 140
Type of Heating System: electric/ oil / -gas/wood f�hotbaseboard/other:
Number of Fireyiaces to be installed �_ Number of W-goi&eaves to be installed
List below the person(s)responsible for supervision of work as-regards-to-building codes:-
Name . Address Phone Number
Builder 0A _ 9' 7 4�_ IrL i
Plumber AbK " a 6dx S'6)L- - 0 r '1Q S 3 k i�3
Mason 'S 15 ZCAJC -«(?__ 3147 . o "ILL (?(> Q A 5-177
Electrician aO 13EAG-r�C t� c.,�t�c�� 1-741 NPR6L- CZb �0 S'31^10
Declaration please sign below after you have careMly read the statement.,
To the best of my knowledge the statements contained in this application,together with the plans and specifications
submitted,are a true and complete statement of all proposed work to be done on the described premises and that all
provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied
with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Uwe shall
submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning
Administrator or Director of Building and Codes,an As Built Survey by a licensed surveyor,drawn to scale,showing actual
location of all new con U.
Signatur 1� owner,owner's agent,architect,contractor
Check Residential Plan Review: One &Two Family Dwellings
Y/N/N/A
Full sets of plans
Over 1,500 sq. ft.—Stamped
Design Loads On Plans: %Wind Floor Loads 40 psf
70 Ground Snow Load Sleeping Areas and Attics 30 psf
Calculations:
indow Schedule With Glass Size
oor Schedule/Main Entrance 36"Door
mergency Escape Or Bedrooms and Habitable Space
Above/Below grade,5.7 sq.ft.
Grade,5.0 sq. ft.
24"(h)x 20"(w)min.
44J Max.Height above floor
sidential Check Paperwork Compliance and Inspectors Checklist: OK
Dampproofing/Waterproofing Materials On Plans
Foundation Drainage On Plans,if required
6"Drop in 10' Exterior Grade
taming Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where
e uired
ce and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls
P &forms At Exterior Doors
Stairway Headroom 6' 8'All Stairs 36"Width
Stair Run and Rise
Winder Run and Rise
Spiral Not Allowed From 2n Story
pllmoke Detectors Battery Backup and Proper Location
Bathroom Fixtures Proper Clearance
Hall Width,36"min.
Handrails More Than One Riser On Open Sides
ailing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht.
S fety Glazing Notes For Required Areas
age Fire Separation
Garage Floor Sloped
41
Attic Access
Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access
Carbon Monoxide Detector Lowest Sleeping Level
Soil Test Results, if required
Septic To Well Or Water Line Separation
All Paperwork Signed
Fire Marshal's Office Town of Queensbusy,742 Bay Road,Queensbury,NY
(518)761-8205
Application for Fuel Burning Appliances & Chimneys
applicable to solid fuel & vented gas .appliances
�
Date "� r `� ,,20 0r N Permit No.
1.
Application is hereby made to the Building& Codes Office for the issuance of a Building and Use
Permit pursuant to'the New York State Fire Prevention and Building Cod(-,. The applicant or owner
agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of
these requirements and also will allow all inspectors to enter premises to per form required inspections.
NOTE to applicant: Rough-in and Final Inspections are required.
Applicant Information Fuel Burning Appliance Information
(circle appropriate words)
Name:s y� , 4��: - _ r' �� Stove: wood coal pellet gas
t Fireplace insert
Address: r= ` _- ` `-( ,, t;yfi;; �"Firep lace;factory-built) wood g .
J? . _ „LN. - ,p i,• Fireplace;rriasonry wood gas
Furnace: wood gas oil
Phone: -
If non-masonary applicance, please provide
Owner: ` _ .t e a , r.�. Manufacturer Frame: � _` v'7'----
Address: �.��� �:.=':_ �_ �-�� ��• C�-- .4.,_
_� Model Number: 1,;V
Chimney Information
Phone: ` ' °� (circle appropriate words)
Masonry block brick stone
Flue tile steel size: inches
Exact Address:
of construction or installation Factory-Built
Manufacturer name:
4•
Model Number: •'C-
Note: Listed By: Number:
Construction/Installation must
conform to NYS Fire Prevention &Building Indicate(circle) chimney material:
Code. Consult available Town of Queensbuiy
Handouts regarding required inspections. Double wall / Triple wall Lrsulated / C15ireci vetl,zti„'g;�,,
Chimney Liner
Cascb�fear-'roc Departmez:t—2'o.r.
�sz of Queen srbury,19Te�X"orA:
-- ; r\
Fire Marshal Corte $Collected x Refunded 1Received from (refumled to)> 1
Caddress:
A 173 3389 (190) Public Safety
A 233 2655 (230)Minor ales
a r
: i DATE 1
White(Applicant) / Green(Fire Marshal) / Yellow(Bldg. Dept.) / Pink R Goldenrod(Cashier's Dept.)
MIDDLE DEPARTMENT INSPECTION AGENCY, INC.
�erlrel that the electrical wiring to the electrical equipment listed below has been examined and is approved as
being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date
noted below and is issued subject to the following conditions.
Owner: Unknown Date: 02/09/2005
Occupant: Same Location: 43 Algonquin
Queensbury, Warren Co. NY
Occupancy:. Single Family Dwg .
Applicant: Don Beagle
1747 Hadley Hill Rd . _.
Hadley, NY 12835
—No. -— — -- 3-1-8,0-1-4-1:3 6,7:9.1 E -
Equipment:
200 Amp. Service Equipment 4/0; 36 - - Switches; ` 50 —`'Receptacles; 32
— GFCI Receptacle; .1 — Air Conditioner; 1 — .,Burner, Wiring &
Controls; :='I - -,Garbage. Disposal; 1 — Dishwa�sheIt- -I — .Dryer; 2 — 20
Amp. Recep,tacles;° 3 , Vent. Fans; 6_ —_ Smoke .Deae.ctors 1 — Carbon
Monoxide Detector
-
This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy and
above and the installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a change in the use,occupancy or ownership
inspection. No warranty is expressed or implied as to the mechanical safety, effi- of the property indicated above,this certificate shall be immediately null and void.
ciency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions,
be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department
system to which this certificate applies be altered in any way,including but not limit- Inspection Agency,Inc. An application for inspection must be submitted to Middle
ed to,the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency, Inc. to initiate the inspection and revalidation
any of the components installed as of the above noted date,this certificate shall be process. A fee will be charged for this service.
Application for Permit-Septic Disposal System
Town of Queensbury 742 Bay Road Queensbury,NY 12804 (51 9)-761-8256
1. OWNER INFORMATION: ...................................................................................................................
- Office Use
Location of installation: 4 3 P�-&0
File Permit No.
Tax Map No. 30 1 / l 3 / I
Owner's Name: P� ���`�-�-"'S� `'��
1..,,Fee Paid ....................................................
Address: a'� E
2, INSTALLER'S NAME : i>~`�,U �0 C-Q-C-I C `)' ' PHONE NO. -7 C1 3 5 70 7
3, RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply#of
bedrooms with applicable gallons per bedroom to equal total daily flow)
Year of House: No of Bedrooms x Computation = Total Daily Flow
1980 or older x 150 gal/bdrm =
1980— 1991 x 130 gal/bdrm =
1991 —present x 110 gal/bdrm =
Garbage Grinder Installed yes_ / no )
Spa or Hot Tub Installed yes_ / no
4. PARCEL INFORMATION: (circle applicable information&indicate measurements)
Tonozraohv Soil Nature Ground Water Bedrock or impervious Material ome r Su 1
lat san at what depth at what depth municipal
Rolling oam ,Feet feet we
Steep slope clay if well;water supply
_%slope other from any septic-system
depth: absorption is ft.
other
Percolation Test: (To be completed by licensed professional engineer or architect)
Rate: minute per inch
5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed
professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size
of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tab.
Septic Tank: Q-5-0 gallon (min. size 1,000 gal)
Tile Field: each trench ft. Total System Length: Q ,fi`.
Seepage Pit(s): number of size of each: ft, by ft.
Size of Stone to be used: # / depth or thickness feet
Bed System Size: x
Alternative System: length and/or size
6. HOLDING TALK S11STEM: (if required)
Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons
Note: Alarm System and associated electrical work must be inspected by a Town approved
electrical inspection agency.
7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON (please read)
For your protection,please note that pursuant to Section 136-29 of the Code of the Town
of Queensbury,any permit or approval granted which is based upon or is granted in
reliance upon any material misrepresentation or failure to make a material fact or
circumstance known by or on behalf of an applicant, shall be void.
I have read the regulations with respect to this application and agree to abide by these and all
requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance.
V "5� -71 q`oq
Signature of responsible person Date
' :►I�q�Vlt t)I� ��lit:('!11�I}tit•y'
St:wtn•:� s»ut 5t:wtt�;c. i)i��)tt�stl t:lts)�}it•:•
AI>>}ondix C,
fiI:I ARA'I'ION Itt,'QUt HEW ION"I`S ,
..�.�..�w�.�.+....�w.�w��.�.....+.�•�� ter. � f
• Y1�t t_ I>J 1/�►T!''i>;• .i �� at m tot .
' M
►Sou SE C'� Q� � � �.�t>•�'" I l r:�ut�>: (-s` & � ..
1. ,�
t 11�1 ty i
1 ....r••N � ` ,�,�'o+• t Ultf tStttS�ttlf�l( ►
7, SIGI�T,P,►"X'U�:E &xt�IFORN'lATIQIri•gQ�Ll�akvr�a�zsL.�� � � ;�:� �� •'':':;'•- � - -
i.
Queensbury Building & Code Enforcement - Vesidialal Inspection
Office No.(518)761-8256 Arrive:Date Inspection request received: C)S Inspector's InitiaNAME: �Y1 L L~,, -3OLOCATION: 3/�lCtc:��t�r- N dl�--e_
TYPE OF STRUCTURE: FZ
L D►-�S� Comments
-- Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6"
Roof Complete/Exterior Finish Complete
Guard 30 in.or more a)stairs, decks,patios r�
Guard at stairwell at 34 in. or more t
Guard at deck,porches 36 in. or morel✓�G�C�
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum %2" /
Gypsum J
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft.or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Dete ors: ) /
Every level: / ery Bedroom: /
Outside every be room ar a: „//
Inter Connected: / Battery backu :
Carbon Monoxide Detector _
Bathroom Fans, if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
Garage Floor Pitched _
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft. vents
Building No./Address visible from road
Final Electrical
Site Plan /Variance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Flood Plain Certification, if required
Okay to issue C/C or C/O Tem orar /Permanent
L:\PamW\Buildiwz&Codes\Inspection Forms\Res. Final Inso. form 2.docLast printed 2/12/04
Final Survey Inspection
Dept. of Community Development
Town of Queensbury
742 Bay Road
Queensbury,NY 12804
Date received:
NAME:
LOCATION: r
PERMIT#: —
Final Survey Plot Plan
ARproved Denied
The attached final
survey has been
received by the
Dept. of
Community
Development.
Upon review the
survey has been:
Craig BrowlaoXing Administrator
Notes:
n
L:\SueHemingway\Building.Codes.Inspection.FORMS\Final Survey
Zoning Administrator.doc
1 sr � , ,, ,r et� :t wf'!w f�� q e�y�,6 �!r,• t'1�r-, ,H, s�r.a� r� P s. rv�,
��� .,! �l•qT x� r BYO �.0 v+l �'II tl_.,ttC CC�Il{aS'� �/� i � '�.�;► vR;;'!. ek �� j '{ ti.-..
r-i' ` 1
Lands n/f
Carroll LaPtznn
L. 1232 P. 215
y= t +C t,i t _y �`, ►. , / FaOTTaG_R ` "�u 7 i '` Lands n/J
Joseph A. Ambrns'in{
! ,
lF 15 ...
f "� i , P 1Ga7Lces Ambrosin'i
e i r IRF
'
x. R _ , L. 674 P. 278
`fie ' r
- 4., i P. 3 r. T•Y r
- i.�* r r I , � I .!�� t.� c t&�,,�.�"'>+� tt�s •°,a _ \ \ � i � Lands n/f
Joanne Sheridan
.�
L. 860 P. 199
I1 tl rd:. 5, e141_ Jf° l�A laP' + S ;i ?` �i J' y Y `vtRF /
F! 1 : ti.
� �
r 4 f � '1 ��432�' „
'
,4! s ` 1;ka I J �.:' .••ti ram,,._✓-x`£}'ey1R,lI ( 1 et '`" IRF
O`;44 141 .�1 Yv�' .,, t�{E _�a�r,,. •f.y..�N �.
Get a
_ (ands ri/f
Steven C677mm '^
v t 5 II I �!, i.l,--•t „ *,. �. i� t V'9, ,r: �. •;'ek. , 1 �-`:� _} \
dr: J91 Cer►one
SITE LOCATION MAP L. 1415 P. 133 -
NO SCALE ,W
o . 30.0'
O W
0.7' CLEAR s,UZi
^ ^ A.C.
W
Z//r UNITE)
/,; fF(QU f - / �• � W
► /,,, ft W
_
PORCH f C Lk Ib a
Lands n/,f
3� OASP\HHALT f James ICCaron
& Valerie D. Caron
coN� wa vj L. 1418 P. 054 I a
tK
IRF —
TEL 7f AC I
\ ELEC.
TRANS. p CAN
IRF
i
Q
DEED REFERENCE. 130 00, LAMP
POST Z
1) CHARLES F. MINEO TO JPEK DEVELOPMENT, INC., FILED IN THE OFFICE 104.2, LEGEND
JOF T E WARREN COUNTY CLERK IN BOOK 1392 AT PAGE 233, DATED .32 5r0.,w e
IRF o I.R.F. IRON ROD FOUND
o I.P.F. IRON PIPE FOUND
,Z o I.R.S. IRON ROD SET
raj UTILITY POLE
000o STONE WALL
MAP REFERENCE: �L�I' � x-ac—x- WIRE FENCE
1) "MAP OF SECTION N0. 5 LAND OF PINES" DATED FEBRUARY 23, 1984, Rjv� \ o CHAIN LINK FENCE
PREPARED BY COULTER AND McCORMACK, LICENSED LAND SURVEYORS. �'
o WOOD FENCE
o POINT
F.P. FENCE POST
—onw OVERHEAD WIRES
n/t NOW OR FORMERLY
NOTES:
1) BASE MAP PREPARED FROM A JANUARY 2005 FIELD SURVEY.
2) NORTH ORIENTATION IS BASED ON MAP REFERENCE 1.
3) PREMISES ARE SUBJECT TO CERTAIN COVENANTS AND RESTRICTIONS AS RECORDED
IN BOOK 652 AT PAGE 070, AND BOOK 698 AT PAGE 741IN THE WARREN COUNTY
CLERKS OFFICE.
4) THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT OF TITLE AND
IS THEREFORE SUBJECT TO ANY EASEMENTS, COVENANTS OR RESTRICTIONS OF RECORD
ANY STATEMENT OF FACTS SUCH DOCUMENT WOULD DISCLOSE.
5) SUBJECT TO APPLICABLE LAWS AND APPROVALS OF THE TOWN, COUNTY, AND STATE
REGARDING THE SUBDIVISION OF LAND. MAP OF A SURVEY MADE FOR
6) UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY MAP BEARING A LICENSED LAND P��OAME
SURVEYORS SEAL IS A VIOLATION OF SECTION 7209, SUBDIVISION 2, OF THE �' 9 JPEK DEVEL OPMENT INC.
NEW YORK STATE EDUCATION LAW. GRAPHIC SCALE y`��' °p
7) ONLY COPIES FROM THE ORIGINAL OF 30 15 30 60 720 R THIS SURVEY MARKED WITH AN ORIGINAL OF THE
0
LAND SURVEYORS SEAL SHALL BE CONSIDERED TO BE VALID TRUE COPIES.
Town of Queensb ury County of Warren State of New York
8) UNDERGROUND UTILITIES, STRUCTURES AND FACILITIES HAVE BEEN SHOWN FROM � 05b0
SURFACE LOCATIONS AND MEASUREMENTS OBTAINED FROM A FIELD SURVEY. ( nJ FEET (gyp S BOLSTER AND ASSOCIATES
THERTYPEE MAY BE AND LOCATIONS OF ALL(ES WHICH THE UTILITIES AND STRUCENCE OF ARE TURES MUST BET KNOWN.VERIFIED BYZE, 1 inch = 30 ft. PROFESSIONAL LAND SURVEYORS
PROPER AUTHORITIES PRIOR TO ANY AND ALL CONSTRUCTION. CALL DIG SAFE PRIOR 342 Main Street, Hudson Falls, New York 12839
TO ANY EXCAVATION.
Russell E. Howard, PLS N.Y.S Lic. No. 50540 Date: 03108105 TM#: 301.13-2-37
Date Sealed: Scale: 1 inch = 30 feet Revised: Drawing #: 05038C
Town of Queensbury Fire Marshal
742 Bay Road
Queensbury,NY 12804 1
761-8205/761-8206
fax 745-4437
Factorry Built Gas Firelalace!Stove kspection Report
Notice:New York State requires that all UL.Listed,factory built appliances be installed according to the instructions anA
specifications contained in the Installation manual accompanying the appliance.No deviation from time manufactu is
instructions or specifications is allowed.
Permit# 0 0 L! 5 �, Schedule Inspection 1�TimeJ : a pm anytime Inspector l�
Name 3 P�\ Address l Rough In_4 nal
Appliance Man ac urer Model#
Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated
Yes No N/A comments
Floor Protection
Clearances to Combustibles (all sides)
Firestop(s) Vertical Chase _
Wall Penetration
Vent Clearances to Combustibles
Vent/Chimney Teratination
Chimney height must be 3 feet above roof
penetration;2 feet above any combustible
construction within 10 feet
Gas Shut-Oil'Valve
Combustion Air
Hearth Extension (if any)
Mantel
Height above f/p opening
Witness Operation
Tank Placement(if LP)
White—BuiidingDept, �" Yellow Coat. er Pink—Fire Manhal
Queensbury Building & Code Enforcement - Residentia al Inspection
"Office No.(518)761-8256 Arrive: a pm art: F a
Date Inspection request received: Inspector's Initial
NAME: '—i IT#:
LOCATION: \ � ATE:
TYPE OF STRUCTURE:
_ Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6"
Roof Complete/Exterior Finish Complete
Guard 30 in. or more @ stairs,decks, atios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in. or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors 67-1EV6 �)EEv-,
,kiftiaor Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum '/" Z-l
Gypsum
Grade away from foundation 6 in. with 10 ft.
Handrail Termination at Newell Post or Wall -- ����` / Cblzs\1t'�Jc
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 fit.or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Tem.p 110
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing/Windo in stairwells safety lzin
Interior Smoke Dete ors:
Every level: / E cry Be/room:
Outside every bedroom ea:
Inter Connected: / Battery backup:
Carbon Monoxide Detector
Bathroom Fans, if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches _
Garage Floor Pitched _
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, 1 sq. ft.-150 s . ft.vents
Building No./Address visible from road
Final Electrical
Site Plan /Variance required \\
Final Survey Plot Plane v�
As Built Septic System/Sewer Dept. Inspection Sticker
Flood Plain Certification, if required
Okay to issue C/C or C/O Temporary/Permanent
L:\PamW\Building&Codes\lnsi)ection Forms\Res. Final Inst). form 2.docLast printed 2/12/04
Town of Queensbury Fire Marshal j
742 Bay Road ;s
Queensbury,NY 12804
761-8205/761-8206
fax 745-4437
Factory Built Gas Fir__glace/Stove Msvection Report
Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and
specifications contained in the:Installation Manual accompanying the appliance.No deviation from the manufacturer's
instructions or specifications is allowed.
Permit#4•U5'k c 0 _ Schedule Inspection ` I�`� Time —'"-Tim tll anytime inspector
Address_ C (,C;ct�Ga-�i Rough In Final
Appliance Manufacturer_ Mom"35 L U Model )V
Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated
^ Yes No N/A Comments
Floor Protection
Clearances to Combustibles (all sides)
Flrestop(s) Vertical Chase �, {
Wall Penetrati"`
/40
Vent Clearances to Combustibles � JJ
Vent/Chimney 'Termination
Chimney height must be 3 feet above roof �'
penetration;2 feet above any combustible
construction within 10 feet
Gas Shut Off Valve � '� / A
Combustion Air 0 v e- I
Hearth Extension (ifany)
ff�
Mantel
Height above f/p opening
Witness Operation
Tank.Placement(if LP)
White—Building Dept. yellow Cast lee I Pink—Fire Manhal
Town of Queensbury Fire Marshal
742 Bay Road
Queensbury,NY 12504
761-8205/761-8206
fax 745-4437
Facto i°y Built Gas Fireplace/Stove T&Dection Report
Notice:New York State requires that all UL Listed,factory built.appliances be installed according to the instructions and
specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's
instructions or specifications is allowed.
Permit# `'L, 7 Schedule Inspection � �� � Time_ � aaaa pm anytime Inspector
Name J'S C - � Q`i l 0Oi'n S nN-ddress - Rough Yn Final_
Appliance Man facturer _\� C` 1 Model# •� 9 V���_
Direct' Factory Built Chimney Flue Size Double Wall Triple Wall Insulated
— --- _ Yes No N/A Comments
Floor Protection' 1) 4 9 G �1;3 6Lb �` �`z /L
Clearances to Combustibles (all sides) vW 7 V
Firestop(s) Vertical Chase
Wall Penetration L,,S.5
Vent Clearances to Combustibles \'�1.
Vent/Chimney Termination
Chimney height must be 3 feet above roof
penetration;2 feet above any combustible
construction within 10 feet
Gas Shut-Off Valve '
� 1-
Combustion Air
Hearth Extension (if any)
Mantel
Height above f/p opening /\
Witness Operation -- h ` "i\\j
Tank Placement of LP) g(
White—Building Dept. ���-�^ Yellow Cast er Pink—Fare ManhM
Dough Plumbing / Insulation Inspection Deport
Office No. (518) 761-8256 Date Inspection request received: Q d
Queensbury Building&Code Enforcement Arrive: am/pm e a am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT #: goo -no
LOCATION: y INSPECT ON: /D I d 6-1X(70
TYPE OF STRU TURF: 5 F -D
Y N N/A
PVC: R-1, R-2,R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/ Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
I % inch min. Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
Cooper, CPVC,Pex One and Two-Family
nsulation/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
LASueHemingway\Building.Codes.Inspection.FORMS1Rough Plumbing Insulation Report.doc November 17,2003
Dough Plumbing / Insulation Inspection Deport
Office No. (518) 761-8256 Date Inspection requ rec ived-
Queensbury Building&Code Enforcement Arrive: p e
742 Bay Road, Queensbury,NY 12804 Inspector's Init ✓
NAME: PERMIT #: 0
LOCATION: ' INSPECT ON:
TYPE OF STRUCTURE: U
Y N N/A
PVC: R-1,R-2,R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
PlumbingVent/Vents in Place
Rough Plumbing/Nail Plates
1 % inch min. Drain Size
Washing Machine Drain 2 inch nun.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction 5-
Water Supply Piping, ���� -13�
Cooper Commercial J`:�� \\P
C er, CPVC,Pex One and Two-Fanul
nsulation/Residential Check/Commercial Check
Proper Vent, Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces r�
Combustion Air Supply for Furnace
Duct work sealed properly/No duct toed
COMMENTS:
vl
LASueHemingway\Building.Codes.Inspection.FORM S\Rough Plumbing Insulation Report.doc November 17,2003
Framing / Firestopping InspectionPort
Office No. (518) 761-8256 Date Inspection r es rec .ve.�
Queensbury Building& Code Enforcement Arrive: ai� rt: e a pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initi
NAME: PERMIT#: �,L -
LOCATION: L INSPECT ON:
TYPE OF STRUCTURE: s-6 F V
Framing _ Y N /A COMMENTS
Jack Studs/Header
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly ! Z i� C) C) U `�
12"O.C. y
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center u
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hours
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W) ��
5.7 sf above/below grade
5.0 sf grade
LASueHemin-way\Bui1din-.Codes.inspection.FORMS\Framing Fir std r0ln/ginspection Report.doc January 28,2003
Framing / Firestopping Inspection Report
-
Office No. (518) 761-8256 Date Inspection req ceiv
Queensbury Building& Code Enforcement Arrive: 2;)-10 m ep a�
742 Bay Road, Queensbury, NY 12804 Inspector's Init' Is:
NAME: �G PERMIT#: �SJ�
LOCATION: INSPECT ON: —C
TYPE OF STRUCTURE:
raming Y N /A► C®1d MENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 (w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire 1 2, 3, 4 hour
F estopping
Penetration sealed -71
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemiii-way\Building.Codes.Inspection.FORMS\l�raming Firestopping Inspection Report.doc January 28,2003
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: a1 ep pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: ��, PERMIT#: nVF-S3 O
LOCATION: _ �' INSPECT ON:
TYPE OF STRUCTURE:
Framing Y N N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 1/2 (w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
e and sn sh'eld inches from wall
Fire separation 1, 2, hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LASueHemin-way\BuiIding.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
N�1E _i
Rough Plumbing / Insulation ln� tion Re ort
Office No. (518) 761-8256 Date Inspection request re ed
Queensbury Building& Code Enforcement Arrive: m e rt: j an m
742 Bay Road, Queensbury,NY 12804 Inspector's Initia .
NAME: PERMIT #:
LOCATION: �� "� cc �t INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1, R-2,R-3,R4 Drain/Vents DI
Cast Iyon, Copper Drain/Vent/ Comm.
P14 bin Vent/Vents in Place
N,,-Ifough Plumbing/Nail Plates
1 % inch min.Drain Size OFF
Washing Machine Drain 2 inch min.
Head or Air Supply'Pest i
Drain and Vents c4lt ,��
5 PSI or 10 feet above highest - 4vl'
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial /
Co er CPVC,Pex One and Two-Family
Insulation/Residential Check/Commercial Check .
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
_ I
U\SueHemingway\Building. on.FORMS1Rough Plumbing Insulation Report. oc November 17,2003
Framing /Firestopping Inspection Report ✓/
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: any/ Depart: m/pm
742 Bay.Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT#: r 153 0
LOCATION: _ INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A Framing COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams .
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in. !.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate.
1 %2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor olts 6 ft. or less on center
Ic nd snow shield 24 inches from wall / OWC
Fire separation 1, 2, 3 hour v/
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H) i
20 in. (W) ,
5.7 sf above/below grade
5.0 sf grade `
L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doe January 28,2003
e�
Septic Inspection Re e "��Z(. "ter j
Se Report p p p
Office No. (518)761-8256 Date In ection4le es
Queensbury Building&Code Enforcement Arrive: a i art: �1 am/�.
742 Bay Rd., Queensbury NY 12804 Inspector's In' al
NAME: NO.:
LOCATION: , A SPECT ON:
RECHECK:
Comments and/or diagram
Soil Tyq6Z<a oamja
Type W Muni ' 'Well Water
Water i e separation distance ��" ft.
Well separation distance ft.
Other,wells: ft. /
Absorption Field: Total length ft• �,
Length of each trench 3 h
Depth of trenches ft• PJ
Size of Stone ' \���t i
Seepage Pits: Number a�
Size: x
Stone Size:
Piping Size Type
Building to tank
Tank to Distribution ox
Distribution Box to Field/Pit
O ening Sealed: Y/N/Partial
Location/Separations
Foundation to tank ft•
Foundation to absorption ft.
Separation of Pits
Conforms as per Plot Plan YK
Location of System on Pro t
Fro Left Side ight Side
Middle Front iddle Rear
Svstem se tatus•
Approved
Partial Approved and needs to be re-inspected,please call the Building&Codes Office
Disapproved
L:\.SueHemingway\BAding.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No. (518) 761-82.56 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: anvp Depart: am/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: _ 1U
NAME: _ — ���? PERMIT#: ( l
LOCATION: (_� -�� ,, _ INSPECT ON:
TYPE OF STRUCTURE: Qy )
Comments
----- __ X N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete,
Materials for this purpose on site.
Foundation/Wallpour
ennforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing i Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 i' ekes above footing
�Inil poly for wet areas under slab
Backfill Approval IJ
Plumbing Under SIab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R- _
Rough Grade 6 inch drop within 10 ft.
L\Sucl3cmingway\BuiIding.Codes.Inspection.TURMS\Foundation Inspection Report.doc January 28,2003
V
Foundation Inspection Report
Office No. (518) 761-82.56 Date Inspection request received: �
Queensbury Building&Code Enforcement Arrive: aril m / Depa am/pm
742 Bay Rd., Queensbury,.NY 12804 Inspector's Initials.
NAME: _ 1 _ PERMIT#: � �
LOCATION: _ U _ INSPECT ON: R
TYPE. OF STRUCTURE:
Comments
Footings ,�
Piers
Monolithic Slab
Reinforcement in
The contractor is responsible for
providing protection from freezing
for 48 hours following'the placement
of the concrete.
Maials forthis p_ oensite._
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for-wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation*Interior/Exterior
R- _
Rough Grade 6 inch drop within 10 ft.
L:\SucHcmingway\BuiWing.Codes.Inspection.TORMS\Foundation Inspection Report.doe January 28,2003
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&.Code Enforcement Arrive: am/l Depart: am/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: —
NAME: _ � / PERMIT#:
LOCATION: _ C 6 fNSPECT ON: _
TYPE OF STRUCTURE:
Comments
Y N N/A
F otings
Piers
Monolithic Slab
Reinforcement in Place 1'
The contractor is responsible for
V
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this pu_pr ose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under SIab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R- _
Rough Grade 6 inch drop within 10 ft.
LASucHcmingway\Bui Win g.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003
4
Permit Number RECEIVED
MECcheck Compliance Report CheckedBy/Date JUL 0 9 2004
Proposed New York State Energy Conservation Construction Code TOWN OF QUEENSBURY
MECcheck Software Version 3.3 Release lb BUILDING AND CODE
Data filename:Untitled
TITLE:J PEK DEVELOPMENT
COUNTY:Warren
STATE:New York
HDD: 7635
CONSTRUCTION TYPE:Detached 1 or 2 Family
HEATING TYPE:Non-Electric
DATE: 07/09/04
DATE OF PLANS: 06/27/03
PROJECT INFORMATION:
062703
COMPLIANCE:Passes
Maximum UA=630
Your Home=501
20.5%Better Than Code
Gross Glazing
Area or Cavity. Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1:Flat Ceiling or Scissor Truss 1416 30.0 0.0 50
Wall 1:Wood Frame, 16"o.c. 3434 19.0 0.0 174
Window 1:Vinyl Frame,Double Pane with Low-E 404 0.370 149
Door 1: Glass 49 0.370 18
Door 2: Solid 84 0.100 8
Basement Wall 1:
Solid Concrete or Masonry,7.6'ht/6.6'bg/7.6'insul 1342 11.0 0.0 87
Floor 1:All-Wood Joist/Truss,Over Unconditioned Space 314 19.0 0.0 15
Furnace 1:Forced Hot Air,90 AFUE
Air Conditioner 1:Electric Central Air, 10 SEER
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building
plans,specifications,and other calculations submitted with this permit application. The proposed systems have been
designed to meet the Proposed New York State Energy Conservation Construction Code requirements.
-43-t Designer. a/ Date l"'d
4
MECcheck Inspection Checklist
Proposed New York State Energy Conservation Construction Code
MECcheck Software Version 3.3 Release lb
DATE:07/09/04
TITLE:J PEK DEVELOPMENT
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation
Comments:
Above-Grade Walls:
[ ] 1. Wall 1:Wood Frame, 16" o.c.,R-19.0 cavity insulation
Comments:
Basement Walls:
[ ] 1. Basement Wall 1: Solid Concrete or Masonry,7.6'ht/6.6'bg/7.6'insul,
R-11.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1:Vinyl Frame,Double Pane with Low-E,U-factor:0.370
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? [ ]Yes [ ]No
Comments:
Doors:
[ ] 1. Door 1:Glass,U-factor: 0.370
#Panes Frame Type Thermal Break? [ ]Yes [ ]No
Comments:
[ ] 2. Door 2: Solid,U-factor: 0.100
Comments:
Floors:
[ ] 1. Floor 1:All-Wood Joist/Truss,Over Unconditioned Space,R-19.0 cavity insulation
Comments:
Heating and Cooling Equipment:
[ ] 1. Furnace 1:Forced Hot Air,90 AFUE or higher
Make and Model Number
[ ] 2. Air Conditioner 1:Electric Central Air, 10 SEER or higher
Make and Model Number
Air Leakage:
[ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be Type IC rated and installed with no penetrations,or Type IC or non-IC
rated installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible
materials and 3"clearance from insulation.
Vapor Retarder:
[ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
[ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11.
[ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6.
[ ] Supply ducts in unconditioned spaces must be insulated to R-11.
[ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2.
Insulation is not required on return ducts in basements.
Duct Construction:
[ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
(adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in.w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
Electric Systems:
[ ] Separate electric meters are required for each dwelling unit.
Fireplaces:
[ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
provisions of the Building Code of New York State,the Residential Code offew York State or
the New York City Building Code,as applicable.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105°F or chilled fluids below 55°F must be insulated to the
levels in Table 2.
Q
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulatine Runouts Circulating Mains and Runouts.
Temperature(F) U_p to V Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
"Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD(Building Department Use Only)
.............
S f
' M
Rr, SP cr
o i2
to
+1
CA
LLJ
LD
cn � v _ �u► t�\
L cU
1`
- F
or, 41,
C
r105o
o Z
�m
r