Loading...
Manual S Job: The springs & + Manual S Compliance Report oetD: Feb08,2019 ., Entire House B Adirondack P&M PO Box 562,Glens Falls,W 12801 Phone:518-793-3883 Email:irfo@adirondadpm wm ���_._ ..�- -_ •� 11,0 t Project • •' L For. The Springs,Monsour DEC 0 7 2020 Queensbury,W 12804 Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 12882 Btuh Entering coil DB: 75.0°F Outdoor design WB: 70.8*F Latentgain: 6171 Btuh Entering coil WB: 62.5*F Indoor design DB: 75.0°F Total gain: 19053 Btuh Indoor RH: 50% Estimated airflow: 687 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitAC Manufacturer. Amana Model: ASX130241C*+C(R,8)30B24+A*VC960804CNA*+TDR Actual airflow: 687 cfm Sensible capacity. 14420 Btuh 112%of load Latent capacity: 6180 Btuh 100%of load Total capacity: 20600 Btuh 108%of load SHR 70% 'Heating Equipment Design Conditions Outdoor design DB: -3.5°F Heat loss: 35086 Btuh Entering coil DB: 68.0°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: Gasfumace Manufacturer. Amana Model: AMSS960402BN Actual airflow: 687 cfm Output capacity. 38000 Btuh 108%of load Temp.rise: 50 OF 308.14-1-26 RC-0765-2020 Monsour Enterprises LLC 3 Amethyst Dr Meets all requirements ofACCA Manual S. SFD w/gas fp 1703 s.f., Gar. 576 s.f. 'Tr Wrightsoft- 2019-Feb-0812:34:43 Right-SUtegUrvversal201818.0.16 RSU21843 Page 1 a te7151Doamerts\WrighhsoftHVAC1TheSprirUsnp Calc=MJB FrortDoorfaoes:N Job: The Springs ��p%R° °,jr� A Form -Worksheet A Dale: Feb 08,2019 �- ., Entire House Br. Adirondack P&M PO Box 562,Glers Falls,W 12801 Phorx.518-793-3883 Email:irto@adirordadpm com Supporting Detail Project Name: TheSprings Date: Feb 08,2019 Address: Queensbury,NY 12804 Phone: Job ID: The Springs Worksheet A Location and Design Conditions Weather Location: Glens FallsAP,NY,US Elevation= 335 1 Latitude= 43 Indoor Conditions,Heating: DB= 68 OF RH= 50 % Indoor Conditions,Cooling: DB= 75°F RH= 50 % Table 1 Conditions 99%DB= -4 OF 1%DB= 85 OF Grains Difference= 27 gdlb Daily Range= M Design Temperature Differences HTD= 72 OF CTD= 10 OF Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2019-Feb-0812:34.43 _,. M,+.•, �,,,�.,, Rigtt-Sute®Uriversal201818.0.16 RSU21843 Page 1 -.ate715%Doamerts\WrigttsoftHVAC17teSprirgsjW Calc=MJB FrortWorfaces:N i HVAC Design Report ENERGY STAR Certified Homes, Version 3 / 3.1 (Rev. 08) HVAC Designer Responsibilities: •Complete one HVAC Design Report for each system design for a house plan,created for either the specific plan configuration(i.e.,elevation, option,orientation,&county)of the home to be certified or for a plan that is intended to be built with potentially different configurations(i.e., different elevations,options,and/or orientations).Visit uww¢energystargov/newhomeshvacdesign and see Footnote 2 for more information. •Obtain efficiency features(e.g.,window performance,insulation levels,and infiltration rate)from the builder or Home Energy Rater. •Provide the completed HVAC Design Report to the builder or credentialed HVAC contractor and to the Home Energy Rater. 1.Design Overview 1.1 Designer name: Designer company: Adirondack P&M Date: Feb 08,2019 1.2 Select which party you are providing these design services to: M Builder or 0 Credentialed HVAC contractor 1.3 Name of company you are providing these design services to(if different than Item 1.1): Monsour 1.4Area that system serves: M Whole-house 0 Upper-level 0 Lower4evel 0Other 1.5 Is cooling system for a temporary occupant load? 0 Yes N No 1.6 House plan: Check box to indicate whether the system design is site-specific or part of a group: 0 Site-specific design.Options)&elevation(s)modeled: 0 Group design.Group#: 0 out of 0 total groups for this house plan. Configuration modeled: Designer 2.Whole-House Mechanical Ventilation Design Verified Airflow: 2.1 Ventilation airflow design rate&run-time meet the requirements of ASHRAE 62.2 2010 or 2013 1:3 2.2 Ventilation airflow rate required by 62.2 for a continuous system 0 CFM - 2.3 Design for this system:Vent.airflow rate: CFM Run-time per cycle: 0 minutes Cycle time: 0 minutes - System type&Controls: 2.4 Specified system 0 Supply 0 Exhaust 0 Balanced - 2.5 Speed control location: (e.g.,Master bath,utility room) - 2.6 Specified controls allow the system to operate automatically,without occupant intervention O 2.7 Specified controls include a readily-accessible ventilation override and a label has also been specified if its function is not 0 obvious(e.g.,a label is required for a standalone wall switch,but not for a switch that's on the ventilation equipment) 2.8 No outdoor air intakes designed to connect to the return side of the HVAC system,unless specified controls operate 0 intermittently and automatically based on a timer and restrict intake when not in use(e.g.,motorized damper) Sound: 12.9 The fan of the specified system is rated s 3 sones if intermittent ands 1 sone if continuous,or exempted 1-3 Efficiency. 2.10 If system utilizes the HVAC fan,then the specified fan type in Item 4.7 is ECM/ICM,or the specified controls WO reduce 0 the standalone ventilation run-time by accounting for hours when the HVAC system is heating or cooling 2.11 If bathroom fans are specified as part of the system,then they are ENERGY STAR certified 0 Air Inlet Location: (Complete this section if system has a specified air inlet location;otherwise check"N/AJ 0 N/A 2.12 Inlet pulls ventilation air directly from outdoors and not from attic,crawlspace,garage,or adjacent dwelling unit 0 2.13 Inlet is Z 2 ft.above grade or roof deck;a 10 ft.of stretched-string distance from known contamination sources(e.g., 0 stack,vent,exhaust,vehicles)not exiting the roof,and z 3 ft.from known sources exiting the roof 3.Room-by-Room Heating&Cooling Loads 3.1 Room-b -room loads calculated usin : N Unabridged ACCA Manual J v8 0 2013 ASHRAE Fundamentals Cl Other perAHIJ - 3.2 Indoor design temperatures used in loads are 70"17 for heating and 75°F for cooling0 3.3 Outdoorciesign temperatures used in loads:(See Footnote 12 and energystargov/hvacdesigntemps) - County&State selected: Washington,NY Cooling season: 85°F Heating season: -4°F 3.4 Number of occupants used in loads: 28 - 3.5 Conditioned floor area used in loads: 2780 Sq.R. - 3.6 Window area used in loads: 108 Sq.R. - 3.7 Predominant window SHGC used in loads: 0.56 - 3.8 Infiltration rate used in loads: Summer. 0.21 Winter. 0.41 - 3.9 Mechanical ventilation rate used in loads. 0 CFM - Loads At Design Conditions(kBtuh) N NE E SE S SW W NW - 3.10 Sensible heat gain(By orientation) 11.6 13.9 14.7 13.1 11.3 13.4 14.4 13.2 - Cooling 3.11 Latent heat gain(Not by orientation) 6.2 - 3.12 Total heat gain(By orientation) 17.8 20.0 20.8 19.2 17.5 19.5 20.5 19.4 - 3.13 Maximum-minimum total heat gain(Item 3.12)across orientations= 3.3 kBtuh Variation is s 6 kBtuh Heating 3.14 Total heat loss(Not by orientation) 35.1 wrigFr,tsoft 2019-Ferr0812:34A3 ^• Riga-Sate®Urdversal201818.0.10 RSU21843 Page 1 ate7151Doarnerts\WrigttsoftWAC\TheSprirgs.rup Calc=MJB FrortDoorfams:N HVAC Design Report ENERGY STAR Certified Homes, Version 3 / 3.1 (Rev. 08) Designer 4.Heating&Cooling Equipment Selection Verified 4.1 Equipment selected perACCA Manual S(see Footnote 19&20) 0 Air Conditioner!Heat Pump (Complete if air conditioner or heat pump will be installed;otherwise check"WA" 0 N/A 4.2 Equipment type: M Cooling-only air conditioner or 0 Cooling&heating heat pump - 4.3 Condenser manufacturer&model: Amana ASX130241 C* - 4.4 Evaporator/fan coil manufacturer&model: Amana C(R,S)3CB24+A*VC960804CNA'+TDR - 4.5AHRI reference#: 7458837 - 4.6AHRI listed efficiency: 10 /13.5 EER/SEER Air-source heat pump: HSPF Ground-source heat pump: COP - 4.7 Evaporator fan type: 0 PSC 0 ECM/ICM M Other. - 4.8Compressortype: 0Singlespeed OTwo-speed 1--3 Variable-speed - 4.9 Latent capacity at design conditions,from OEM expanded performance data: 0 kBtuh - 4.10 Sensible capacity at design conditions,from OEM expanded performance data: 0 kBtuh - 4.11 Total capacity at design conditions,from OEM expanded performance data: 0 kBtuh - 4.12 Air-source heat pump capacity: At 17"F: 0 kBtuh At 47"F: 0 kBtuh N N/A - 4.13 Cooling sung%=Total capacity(Item 4.11)divided by maximum total heat gain(Item 3.12): 0% - 4.14 Complete this Item if Condition B Climate will be used to select sizing limit in Item 4.15.Otherwise,check"N/A": M N/A - 4.14.1 Load sensible heat ratio=Max sensible heat gain(Item 3.10)/Max.total heat gain(Item 3.12) = 70% - 4.14.2 HDD/CDD ratio(Visit energystargov/hvacdesigntemps to determine this value for the design location) = 3.3 - 4.15 Check box of applicable cooling siting limit from chart below - Equipment Type(Per Item 4.2)& Compressor Type(Per Item 4.8) Climate Condition(Per Item 4.14) Single-Speed Two-Speed Variable-Speed For Cooling-Only Equipment or Recommended:90-115% Recommended:90-120% Recommended:90-130% For Cooling Mode of Heat Pump in O Allowed:90-130% 0 Allowed:90-140% 0 Allowed:90-160% Condition A Climate For Cooling Mode of Heat Pump in 0 90%-100%,plus 15 kBtuh 0 90%-100%,plus 15 kBtuh 0 90%-100%,plus 15 kBtuh Condition B Climate 4.16 Cooling sizing%(4.13)is within cooling sizing limit(4.15) 0 Furnace (Complete K furnace will be installed;otherwise check"WA" O N/A 4.17 Furnace manufacturer&model: AmanaAMSS9604026N - 4.18 Listed efficiency: 96.1 AFUE - 4.19 Total capacity: 38 kBtuh - 4.20 Heating siting%=Total capacity(Item 4.19)divided by total heat loss(Item 3.14): 108% - 4.21 Check box of applicable heating stung limit from chart below. When Used for Heating Only When Paired With Cooling O 100-140% M Recommended:100-140%Allowed:100-200% 4.22 Heating sizing%(4.20)is within heating sizing limit(4.21) 6.Duct Desi n (Complete if heating or cooling equipment will be installed with ducts;otherwise check"WA" 0 N/A 5.1 Duct system designed for the equipment selected in Section 4,perACCA Manual D 5.2 Design HVAC fan airflow. Cooling mode 687 CFM Heating mode 687 CFM - 5.3 Design HVAC fan speed setting(e.g.,low,medium,high): Cooling mode Medium Heating mode Medium 5.4 Design total external static pressure(corresponding to the mode with the higher airflow,in Item 5.2): 0 IWC - 5.5 Room-by-room design airflows documented below which must sum to the mode with the higher airflow in Item 5.2) - Room Name Design Airflow(CFM) Room Name Design AN=(CFM) 1 Room10 49 13 Rooms 28 2 Roomll 25 14 Room6 47 3 Room12 40 15 Room? 100 4 Room13 38 16 Room9 48 5 Room14 38 17 6 Room15 0 18 7 Room16 53 19 8 Room17 24 20 9 Room18 80 21 10 Room2 40 22 11 Room3 50 23 12 Room4 27 Total for all rooms 687 wrightsoft- 2019-Feb-0812:34:43 ^^.11.1-1.••••• � Rigft-SLte®Uriverml201818.0.16RSU21843 Page 2 ...ate7151Doarnerts\Wrigrtm#WAC\TteSpririgs.nip Calc=MJB FrontDoorfams:N Specification " X 1 OH -�� _-__ R. _ , ,FLE0 o. . ll DEC 0 7 2020 y Heat Recover Ventilator L( � _ Product#: 44001 - Two-0 factory-balanced fans with backward curved blades.Motors come with permanently lubricated,sealed ball-bearings to guarantee long life . a � an maintenance-free oper ation. cc:,.. r N Beat Recovery Core y ;�:=��.�--�'�•w Aluminum heat recovery core covered by a limited lifetime warranty.Core dimensions are 8.5"x 8.5"1216 x 216 mm)with a 12"(305 mm)depth. Our heat exchangers are designed and manufactured to withstand yes r, extreme temperature variations. ' yymtinuardTm Belrost The FLEX 100H incorporates a unique and quiet internal recirculation defrost that does not depressurize the home during the defrost cycle.A preset defrost sequence is activated when the outdoor temperature falls below 23°F t-5°C)and automatically adjusts itself based on operating As Fantech's masterpiece of versatility,features and efficiency,the Flex conditions.The fan speed is also adjusted automatically to provide a 100H is ideal for high-rise apartment applications, condominiums,single smooth and quiet transition between Ventilation&Defrost mode. and multi family homes.With its compact top port design featuring 5 Serviceability inch oval collars and the included EZ-MountTm wall bracket,the Flex Core,filters,fans and electronic panel can be accesses easily from the 100H can be installed in spaces as small as 24 inches,such as a closet access panel. Core conveniently slides out with only 14'1356 mm) or maintenance room. clearance. Unlike traditional HRVs that require excessive power to meet Burt connections supplemental ventilation needs,the compact,yet powerful Flex 1 OOH 5"1125mm)Oval plastic duct connections with integrated balancing allows for sizing based entirely on principal ventilation requirements, damper and airflow measurement ports. With its exclusive TurboTcuchTm feature,the Flex 100H can deliver up to 50%more exhaust capacity to easily meet supplemental ventilation Case needs whenever additional airflow is required. 24 gauge galvanized steel.Baked power-coated paint for a superior adhesion and resistance. Features • TurboTouch function boosts exhaust capacity by up to 50% Insulation • 5"(125mm)oval duct connections with integrated airflow Cabinet is fully insulated with 1"(25 mm)high density expanded measurement polystyrene. • Removable screw terminal for easy connection Filters • Lightweight:only 39 lbs 117.7 kg)including core Two(2)washable electrostatic panel type air filters 8.5"1216mml x • Super compact size 12.5"1318 mm)x 0.125'(3mml. • Top port design fits in tight spaces • Includes EZ-Mount wall bracket Drain • Aluminum heat recovery core 1/2'[13mm)OD[outside diameter)drain spout provided,entire bottom • Multiple speed operation of unit covered by drain pan. • Internal recirculation defrost optional Controls: warranty • ECO TOUCH®rs44szsr — Programmable Touch Screen Wall Control Limited lifetime on aluminum core,7 year on motors,and 5 year on parts. • EOF7 im4rm — Electronic multi-function dehumidistat • RTS2 (naoism — 20 minute timer over-ride • RTS5 (444794) — 20/40/60 minute timer • MDEH1 w4wo — Dehumidistat 308.14-126 RC-0765-2020 Specifications Monsour Enterprises LLC • Duct size — 5(125mrW oval • Voltage/Phase — 12011 3 Amethyst Dr • Power rated — 168 W SFp W�gas fp 1703 s.f., Gar. 576 s.f. • Amp — 1.4 A • Average airflow — 105 cfm(50 Us) 0 0.4-P.(100Pa1 • ' fantech� a systemair company "Dimension 6 Willow E I F� fresh ale to inside D fresh air from outside stale air from inside —P stale air to outside Flex 1 DOH 21 1/2 546 141/2 36B 15 5/8 397 17 7/8 454 221/2 572 15 381 Dimensional information is in inches.Clearance of 14't356nmml in front of the unit is recommended for removal of core.All units feature three foot plug-in power cord with 3-prong plug. Ventilation Perfomrance Airflow UJs) ®®®®®®®® 0 12 24 35 47 59 71 82 9400 3 Net supply airflow 146169) 129(611 116155) 105149) 95(451 88(411 80(381 73(34) CluX _=_ wl 0.8:-,; hr. r}'.'-r -ys ,..T. q:. `s,rr;: 200 Gross exhaust airflow 148(70) 133[631 120[571 107(511 95(45) 85(401 73(35) 63003 � >~• '}����••. �--y,�;F:- � °Turtm Mods is an intermittent mode only.It can be activated with the RTS2.RTS5 and the EL'0 Touch for up W 60 minutes. a u s 'Fuvi; Only the data of the normal speed are HVI certified. 0.2 rAi x 50 0 25 50 75 100 125 150 175 200 Airflow(efnd Energy performance efficiency effectiveness transfer 32 0 52 24 46 70 80 -0.OB 32 D 99 py4�t7yyy 102 54 l 73 -0.04 ''' V .I a � I'n I pl➢Y �1' Pw I ..I I' Require®enb and standards • Complies with the UL 1812 requirements regulating the construction and installation of Heat Recovery Ventilators • Complies with the CSA C22.2 no. 113 Standard applicable to ventilators • Complies with the CSA F326 requirements regulating the installation of Heat Recovery Ventilators • Technical data was obtained from published results of test relating to CSA C439 Standards • HVI certified and ENERGY STAR@ qualified* This product earned the ENERGY STARK by meeting strict efficiency guidelames set by Natural Resources Canada and the LIS EPA.It meets ENERGY SfAR0 requirements only when used in Canada. contaed Distributed by: Submitted by Date: Quantity' Model: Project#: Comments: Location: Architect' Fnoineer• Contractor' United States 10048 Industrial Blvd.•Lenexa,KS 66215*1.800.747.1762•www.fantmiI.net Canada 50 Kanalflaf¢Way•Bouctouche,NB E45 3M5.1.B00.565.3548•www.fantech.nettee Systemair reserves the right tomodify,at any time and vrithout notice,any or all of its products'features,designs.compo- • fantech new and specifications to maintain their technological leadership position. •��; a systemair company