ResCheck C" Compliance Certificate e jl G DEC 0 7 2020 Project ranch Energy Code: 2018 IIECC Location: West Glens Falls, New York Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 1#703 ft2 308.14-1-26 RC-0765-2020 Glazing Area 26% Climate Zone: 6 (7377 HDD) Monsour Enterprises LLC Permit Date: 3 Amethyst Dr Permit Number: SFD w/gas f p 1703 SJ., Gar. 576 s.f. Construction Site: Owner/Agent: Designer/contractor: Compliance: 0.7%Better Than Code Maximum UA: 289 Your UA: 287 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy Use or cost relative to a minimum-code home. A s Ceiling: Flat Ceiling or Scissor Truss 1,703 49.0 0.0 0.026 44 Wall:Wood Frame, 16"o.c. 1,731 21.0 0.0 0.057 80 Door: Solid Door(under 50%glazing) 20 0.190 4 Door 1:Solid Door(under 50%glazing) 20 0.150 3 Door 3:Glass Door(over 50%glazing) 23 0.300 7 Door 3: Glass Door(over 50%glazing) 23 0.300 7 Window:Vinyl Frame 238 0.270 64 Basement:Solid Concrete or Masonry 1,703 0.0 15.0 0.046 78 Wall height:8.0' Depth below grade:7.3' Insulation depth: 7.7' Compliance Statement. The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory req . nts listed in the REScheck Inspection Checklist. No 0 AIAACAU a Z-6 I.),\ Name-Title Signature Date Project Title: ranch Report date: 12/03/20 Data filename: Pagel of 9 17E 5 c, e c a ii: b,C. D G,C at ki. U a 1, a ie S a E. Inspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions Req.113 103.1, Construction drawings and ElComplies 103.2 documentation demonstrate 0Does Not [PR1]1 energy code compliance for the E]Not Observable building envelope.Thermal envelope represented on ONot Applicable construction documents. 103.1, Construction drawings and OComplies 103.2, documentation demonstrate ElDoes Not 403.7 energy code compliance for E]Not Observable [PR3]1 lighting and mechanical systems. ElNot Applicable Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1' Heating and cooling equipment is Heating: Heating: OComplies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr []Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ONot Observable Manual J or other methods Btu/hr Btu/hr approved by the code official. ONot Applicable Additional Comments/Assumptions: I I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: ranch Report date: 12/03/20 Data filename: Page 2 of 9 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [FO4]1 insulation R-value.Where interior R- R- ❑Does Not table for values. insulation is used,verification []Not Observable may need to occur during Insulation Inspection. Not []Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [FO5]1 insulation installed per ❑Does Not manufacturer's instructions. []Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [FO6]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [F011]z to protect exposed exterior []Does Not insulation and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not []Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: ranch Report date: 12/03/20 Data filename: Page 3 of 9 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR111 []Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies see the Envelope Assemblies 402.3.1, average). []Does Not table for values. 402.3.3, []Not Observable 402.5 ❑Not Applicable [FR2]1 pp 303.1.3 U-factors of fenestration products [ Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR2311 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 []Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish []Does Not and labeled to indicate s2.0 cfm [_-]Not Observable leakage at 75 Pa. ❑Not Applicable 403.3.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >_ R-6 where< 3 inches. Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>=3 inches and R-4.2 for<3 inches in diameter. 403.3.2 Ducts, air handlers and filter ❑Complies [FR13]1 boxes are sealed with ❑Does Not joints/seams compliant with International Mechanical Code or []Not Observable International Residential Code,as ❑Not Applicable applicable. 403.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: ranch Report date: 12/03/20 Data filename: Page 4 of 9 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req. ID 403.3.7 Ducts declared to be within the ❑Complies [FR28]3 conditioned space are either 1) ❑Does Not completely within the continuous air barrier and within the building []Not Observable thermal envelope, 2)buried ❑Not Applicable within ceiling insulation in accordance with Section R403.3.6 and the air handler is located completely within the continuous air barrier and within the building thermal envelope and the duct leakage is<= 1.5 cfm/100 square feet of conditioned floor area served by the duct system, or 3)the ceiling insulation R-value installed against and above the insulated duct>=to the proposed ceiling insulation R-value, less the R- value of the insulation on the 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 OF or chilled fluids ❑Does Not below 55 OF are insulated to >_R- ❑ 3 Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not []Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not []Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air []Does Not intakes and exhausts. ❑Not Observable []Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: ranch Report date: 12/03/20 Data filename: Page 5 of 9 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least Yz of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: ranch Report date: 12/03/20 Data filename: Page 6 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2. ❑ Steel ❑ Steel ❑Not Observable 402.2.E ❑ [FI1]1 Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not (F12]1 Blown insulation marked every ❑ 300 ft2.. Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [FI3]1 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable El Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50= ❑Complies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [FI4]1 cfm/100 f:2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in []Not Observable tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2.1 Air handler leakage designated ❑Complies [FI24]1 by manufacturer at<=2%of ❑Does Not design air flow. []Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [FI9]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [F110]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: ranch Report date: 12/03/20 Data filename: Page 7 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system ❑Complies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits per Table ❑Not Observable R403.6.1. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI26]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply []Not Observable pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [FI29]2 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the []Not Applicable desired water temperature in the piping. 403.5.2 Demand recirculation water ❑Complies [F130]2 systems have controls that ❑Does Not manage operation of the pump and limit the temperature of the ❑Not Observable water entering the cold water ❑Not Applicable piping to <= 1042F. 403.5.4 Drain water heat recovery units ❑Complies [FI31]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat []Not Observable recovery units <3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 90%or more of permanent ❑Complies [F16]1 fixtures have high efficacy lamps. ❑Does Not ❑Not Observable ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [FI23]3 no continuous pilot light. ❑Does Not ❑Not Observable []Not Applicable 401.3 Compliance certificate posted. ❑Complies [F[7]2 ❑Does Not ❑Not Observable []Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: ranch Report date: 12/03/20 Data filename: Page 8 of 9 Section Plans Verified Field Verified • # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: ranch Report date: 12/03/20 Data filename: Page 9 of 9 Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 0.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Window 0.27 Door } �� r0.30 Heating System• Cooling System• Water Heater• Name• Date: Comments