ResCheck Generated by REScheck-,Web Software ::Compliance ie � : . . . . . . . . . . Project Mary and"Mark-:osborne Energy Code: 2018 IECC Location: Glens Falls, New.-York . . 290.13-1-25 RC-0692-2020 Construction Type: . . .Single-family: Project Type:. .: New Construction' - . - Collette, Ken Conditioned Floor"Area: 2,275 ft2 8 Fairway Ct, lot 2 Glazing Area 14% SFD w/gas fp 2275 S.f., Gar. 960 S.f. Climate Zone:. 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: :Designer/Contractor: Fairway Court Daniel W.-Ryan P.E. Lot 2 . : . . . . PO Box 596- . . Queensbury, NY 12804 Glens Falls,NY 12801 : dryan@dwrpe.com Compliance: trade-off Compliance: 0.6°/.Better Than Code Maximum UA:.352. Y.our'UA: 350 The%:Better-or Worse Than Code Index reflects Flow close to compliance the house is based on code trade-off rules. It DOES NOT.provide'an estimate of energy use or cost relatibe to a'minimum-code home. . . . . . . .. . .. .. . . Envelope Assemblies Gross Area Assembly or Cavity Cont. U-Factor UA Perimeter Ceiling 1: Raised or-Energy Truss .2,275 49.0 : 0.0 0.020: 46 Wall l:Wood Frame;:16"o.c. 2,331 21.0 _ .0.0 0.057-. 11.5 . Door'3: Fire Door:solid. . 18" . '0.140:. . . . 3 . . Door 1: Front: Glass 80 0.290 " 23 Door 2:-Back:"Glass 20 0:240: -5 Window 1:Vinyl"Frame:Double Pane with.Low-E 200 0.290. 58 Floor 1:All-Wood joist/Truss:Over Outside Air, 12 30.0" 0.0 0.033 0 Basement Wall 1:Solid Concrete or-Masonry.: 2,020 . 19.0 .. 0.0. 0.046. : 92. . . Wall height:.7:8' Depth below grade:6.8' Insulation depth: 7.8' . . :Window 3:Vinyl/Fiberglass Frame:Double Pane 7 0.400 3 Window 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290. 5 052020 - NO.V Trt Project Title: Mary and Mark-Osborne LUILl7git,(� ,J ;r�, Report date:.- Tl/01/20 - Data filename:" Page 1 of10 Compliance Statement, The proposed building design described here is consistent with the,building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandat irge n listed in the REScheck Inspection Checklist. Daniel W. Ryan_P.E. 11/1/20 Name-Title Signature Date . ENGINEERS STAMP: C, I - I,Cu 10 n SRO ` A/'�IN i' 1 r6p,r. .,�. .i,o .0 07( ROfiES Sl . . . . . ... . . . Project Title: Mary-and Mark Osborne Report date: 11/01/20 .Data filename: Page 2 of10 REScheck. Software Version. : REScheck-Web Inspection Checkiist I Energy.Code: 2018 IECC. Requirements: 0..0% were addressed directly.in the REScheck software Text in the "Comments/Assumptions" column.is provided by the user in the REScheck Requirements screen:.For each. requirement,'the user certifies that a code requirement will be met and how that is documented, or that an exception, is being claimed. Where compliance is itemized in a.separate,table, a:reference to that.table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, ;Construction drawings and #❑Complies 103.2 -;'documentation demonstrate. I❑Does Not ; [PRl]1 ;energy code compliance for the V "building envelope.Thermal ❑Not Observable envelope represented on. ❑Not Applicable I . ;construction documents. 103.1, ;Construction drawings and } ❑Complies ; 103.2, (documentation demonstrate I❑Does Not. 4.03:7 ;energy code compliance for [PR'3]l. ;lighting and mechanical systems. _ ❑Not Observable U. . Systems.serving multiple ❑Not Applicable. ; dwelling units must demonstrate i compliance with the IECC i ;Commercial Provisions. l i 302.1, !,Heating and cooling equipment is; Heating:'_. Heating: . Complies 403.7 :sized per ACCA Manual S_based Btu/hr Btu_/hr - ;❑Does'Not [PR2]2 j on loads calculated per CC Cooling: Cooling: : Not Observable le? I Manual j or other methods ❑ - approved by the code official. Btu/hr - Btu/hr. ❑Not Applicable Additional Comments/Assumptions: 1 jHigh Impact.(Tier.1) 2 Medium Impact(Tier 2)'. 3 Low Impact(Tier 3) Project Title: Mary'and Mark•Osborne Report date:- 11/01/20 Data filename: Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 ;Conditioned basement.wall R- R- ;❑Complies ;See the.Envelope Assemblies [F0411insulation-R-value:Where interior R I R_ ;table for values. . ❑Does.Not insulation is used,verification lA) - ❑Not Observable ; may need to occur during Insulation Inspection. Not ;❑Not Applicable required-in warm-humid locations; in Climate Zone 3. 303.2 ;Conditioned basement wall 3 '❑Complies [F05]1 :insulation-installed per ! '❑Does Not manufacturer's instructions. 1❑Not Observable ❑N6t Applicable ;. 402.2.9 IConditionedbasement.wall ft ft ;❑Complies ;See the Envelope Assemblies _ 1 . ; :table for values. [F06] insulation depth of burial or - ;❑Does Not. , J ;distance_from:top of wall. j ;❑Not Observable ' ❑Not Applicable 303.2.1 ;"A protective covering is installed Complies [FO11]2 'to protect expdsed exterior ! ❑D.oe,s Not insulation and extends a U (minimum of 6 in. below grade. ; ❑Not Observable i ,❑Not Applicable 403.9 Snow-and ice-melting system i❑Complies.. [F012]2 i controls installed. (❑Does Not J❑Not Observable ; j ;❑Not Applicable Additional Comments/Assumptions: 1 High Impact.(Tier.1) 2 Medium Impact(Tier 2) . 3 Low Impact.(Tier 3) Project Title: Mary and Mark Osborne Report date: 11/01/20 Data filename: Page 4 of10 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, ;Door U-factor: U- U- ;❑Complies ;See the Envelope Assemblies . 402.3.4 ❑Does,Not table for values. [FRl]1 . . J ,❑Not Observable ; ❑Not Applicable ; 402.1.1, ;Glazing 0-factor(area-weighted U- U= ;❑Complies ;See the Envelope assemblies 402.3.1, - average). ;❑Does Not table foe values. . 402.3.3, 402.5 ;❑Not Observable [FR2]1 ;❑Not Applicable 303.1.3 ;U-factors of fenestration products; II❑Complies" [FR4]1 lare-determined in accordance f HDoes Not J with the NFRC test procedure or { f ;taken from the default table. ❑Not Observable , I❑Not Applicable ;. 402.4.1.1" ;Air barrier and thermal barrier ODoes Complies.[FR23]1 :.installed.per manufacturer's I Not J ;instructions. I❑Not Observable JONot Applicable 402.4.3 ;Fenestration that is not site built ! ;❑Complies [FR20]1 :is listed and labeled as meeting '❑Does Not J ;AAMA./WDMA/CSA 101/I.S.2/A440 S❑Not Observable ,or has infiltration rates per NFRC ; , 400 that do not exceed code !❑Not Applicable limits. ; I 402.4.5 !IC-rated recessed lighting fixtures.; (❑Complies . [FR16]2 rsealed at housing/interior finish ;❑Does Not and labeled to indicate 25_2.0 cfm leakage at 75 Pa. bNot observable 1 S❑Not Applicable 403.3.1 ;Supply and return ducts in attics ; ElComplies [FR12]1. .;insulated >= R-8 where duct is ( J❑Does Not J. >= 3 inches in diameter and >= R-6 where < 3 inches.Supply and j ❑Not.Observable I return ducts in-other portions of i f❑Not Applicable ;the building insulated >= R-6 for s I diameter>= 3 inches and R-4.2 :for<3 inches in.diameter. I 403.3.2 ;Ducts, air'handlers and filter ; ❑Complies [FR13]1 ;boxes are sealed with ❑Does Not, J ;joints/seams compliant with - International Mechanical Code or ; ❑Not Observable International Residential Code, as; ❑Not Applicable- - j applicable. 403.3.5 (Building cavities are not used as (❑Complies [FR15]3 ducts or plenums. ,❑Does Not . I❑Not Observable I❑Not Applicable 1 High Impact(Tier 1) 12 1 Medium Impact(Tier 2) . 3 1 Low Impact.(Tier3) Project Title: Mary and Mark Osborne Report date'- 11/01/2.0 Data filename: Page 5 of10 Section Plans Verified Field Verified # Framing/Rough-in Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.3.7 ,.Ducts declared to be within the . } ❑Complies [FR28]3 'conditioned space are either 1) i ❑Does.Not completely within the continuous 1 e p y ❑Not Observable ; air barrier and within the building , thermal envelope,2) buried. I i❑Not Applicable j.within ceiling insulation-in !accordance with Section f.R403.3.6 and the:airhandler is, located completely within the continuous air barrier and within i the building thermal envelope and the duct leakage is <= 1.5 .f cfm/100 square feet of conditioned floor area served by ithe duct system,or 3)the ceiling insulation R-value installed ; l against and above the insulated f duct>=to the proposed ceiling. i.insulation.R-value, less the R-. value of the-insulation,on the I 403.4 ;HVAC piping conveying fluids R- . R- ;❑Complies [FR17]2 !above 105°F or chilled fluids ;❑Does Not below 55°F are insulated to >_R-- 9) 13 ;❑Not Observable ❑Not Applicable. 403.4.1 ;Protection of insulation on HVAC ; (❑Complies [FR2411 :piping. 1❑Does Not �j ❑Not Observable i ❑Not Applicable 403.5.3 ,Hot water pipes are insulated to R- ; R- . ;❑Complies [FR18]2 1>_R-3. ❑Does Not U i ;E]N6t Observable ; ONot Applicable 403.6 ;Automatic or gravity dampers are; ❑Complies [FR19)2 I installed on all outdoor air ! ❑Does Not intakes and exhausts. . . . ❑Not Observable 1 I (❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier.1) 1 2 IMedium Impact(Tier 2) . 3 Low Impact(Tier 3) . Project Title: Mary-and Mark Osborne Report date: 11/01/20-- Data filename: Page 6 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 z iAll.installed insulation is labeled . ❑Complies ; [IN13] or the installed R-values ❑Does.Not. {provided. . AJ { i ❑Not Observable I ❑NotApplicable 402:1.1, ;Floor insulation R-value: R- ;:R= ;❑Complies ;See the Envelope Assemblies 402'.2.6 ;table foe values. ❑ .Wood ❑ Wood ;❑Does Not . [IN111 St eel. . Steel . . V ;0 ,El ',❑Not Observable ; ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a: R- R- ;❑Complies ;See the Envelope Assemblies 402.2.5, :mass wall with at least 1/2 of the I 1Nood,_ ;table for values. . 402.2.E ;well insulation on the wall : ❑ Wood Oboes Not i . . [IN311 exterior;.the exterior insulation Mass ❑ Mass ❑Not Observable , V :requirement applies(FR10). ❑ Steel' i❑ Steel ❑Not Applicable 303.2 ;Wall insulation is installed per {❑Complies - [IN4]1 manufacturer's instructions. ❑Does Not j ! ❑Not Observable ; {❑Not Applicable Additional Comments/Assumptions: T High Impact.(Tier.1) 2 Medium Impact(Tier 2) . 3 Low Impact(Tier.3) Project Title- Mary and Mark-Osborne Report date: 11/01/20 Data-filename; Page 7 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- .I R- ;❑Complies ;See the Envelope Assemblies 402.2.1, . ;0 Wood ;❑ Wood ;❑Does Not table for values. - 402:2.2, . �. , 402.2.E ;❑ Steel ElSteel ❑Not Observable [Fill' ;❑Not Applicable M3.1.1.1,-;Ceiling insulation installed per, Complies 303.2 manufacturer's instructions. i ❑Does Not [FI2]1 ,Blown Zinsulation marked every ;❑Not Observable ' 300 ft , iONot Applicable. 402.2.3 ;Vented attics with air permeable j ;❑Complies [F122]2 1 insulation include-baffle adjacent" J❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable i❑Not Applicable 402.2.4 ;Attic access hatch and door ;.R- R- ;❑Complies [F1311 :insulation ?R=value.of the. ;❑Does Not ;adjacent assembly. ; ❑Not Observable , ;❑Not Applicable 402.4.1.2. ;Blower door test @ 50 Pa. <=5 AC,H 50 = ACH 50 = ;❑Complies [FI17]1 ach in Climate Zones 1-2,and ElDoes Not <=3 ach in Climate Zones 3-8. ❑Not Observable ; ❑Not Applicable 403.3.3 ;Ducts are pressure tested to cfm/100 ; cfm/100 ;❑Complies" [F127]1. ;determine air leakage with ft2 ftz El Does Not ;either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ;❑Not Applicable w.g. across the system including. ;the manufacturer's air handler, 1 " ;enclosure if installed at time of I test. Postconstruction test:Total leakage measured.with a pressure differential of 0.1 inch j w.g across the entire system including the manufacturer's air ; handler:enclosure. 403.3.4 . ;Duct tightness test result of<=4 cfm/100 cfm/100 ;❑Complies [F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3-cfm/100 ft2 without air handler @ 25 Pa. For rough-in- ❑Not Observable tests,verification may need to ;❑Not Applicable ; occur during Framing Inspection. 403.3.2.1 ;Air handler leakage designated ;❑Complies [F12411 :by manufacturer at<=2%of !. 1❑Does Not design air flow. 1 ❑Not Observable ; l❑Not Applicable 403.1.1 Programmable'thermostats ; f❑Complies ' [FI9]2 I installed for control of primary I ❑Does Not heating and cooling systems and ; i initially set by manufacturer to 1 ❑Not Observable , I code specifications. j❑Not Applicable 403.1.2 'Heat pump thermostat installed ; ❑Complies [FI10]z on heat pumps. ODoes Not . ; ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water I i❑Complies ; [FI11]2 I systems have automatic or ; 1❑Does Not accessible manual controls. 1 I 1❑Not Observable 1❑Not Applicable 1 High Impact.(Tier 1) 2 Medium Impact(Tier 2) . 3 Low Impact(Tier 3) Project Title: Mary and Mark Osborne Report date: 11/01/20 Data filename: Page 8 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 ;AII mechanical ventilation system; ❑Complies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits per Table I❑Not Observable (R403.6 j. . i PNot Applicable 403.2 Hot water boilers supplying heat ;❑Complies [FI26]2 ithrough.one-or two-pipe heating 1 J❑Does Not systems have outdoor setback control to lower boiler water, ; ❑Not Observable ;temperature based on outdoor f ❑Not Applicable temperature. { 403.5.1.1 I Heated water circulation systems ; ❑Complies. [F128]2 1.have a circulation pump.The ❑Does Not {system return pipe is a dedicated ; 'return pipe or a cold water supply; ❑Not Observable ; {pipe. Gravity and thermos- J❑Not Applicable 4 syphon circulation systems are not present. Controls for i circulating hot water system ! pumps start the pump with signal+ # - for hot water demand within the l ! occupancy. Controls I ;automaticallyturnoffthepump - ,when water is in circulation loop ; I is at set-point temperature and . I no demand for hot water exists. E 403.5.1.2 i Electric heat trace systems j 111Complies, [F129]2 i comply with IEEE 515.1 or UL `❑Does Not 515.Controls automatically , ; ; {adjust the energy input to the ;❑Not Observable , {heat tracing to maintain the i {❑Not Applicable i desired water temperature in the j l piping. . 403.5.2 ;Demand recirculation water. 10complies [F130]2 {systems have controls that 1 j❑Does Not imanage operation of the pump E❑Not Observable ' and limit the temperature of the , !water entering the cold water ! }❑Not Applicable i piping to <= 1049F.- I 403.5.4 Drain water heat recovery units r }❑Complies [FI31]2 nested in accordance with CSA ElDoes Not . B55.1. Potable water-side ; pressure loss of drain water heat ! ❑Not_Observable ; recovery Units < 3 psi for f J❑Not Applicable individual.units connected to one or two showers. Potable water- !side pressure loss of drain water 1 j heat recovery units< 2 psi for E individual units connected to three-or more showers. ! 404.1 ;90%or more of permanent' j (❑Complies [FI6]1 :fixtures have high efficacy lamps.: ❑Does Not ❑Not Observable ❑Not Applicable, 404.1.1 (Fuel gas lighting systems have ; ❑Complies [FI23]3 1�no continuous pilot light.- E]Does Not ) 1 ; ❑Not Observable ❑Not Applicable 401.3 ;Compliance certificate posted. ; !OComplies, [FI7]2 ! I ❑Does Not I❑Not Observable I❑Not Applicable 1 High Impact.(Tier 1) 2 Medium Impact(Tier 2) 13 ILow Impact.(Tier3) Project Title: Mary and Mark Osborne Report date:. 11/01/20 .Data filename Page 9 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 303.3 :Manufacturer manuals for , (❑Complies [1`I18]3 mechanical and water heating r ❑Does Not i systems have been provided: i - E❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact.(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Mary and Mark-Osborne Report date:. 11/01/20 Data filename: Page 10 of10 2018 IECC -Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 30.00 Ceiling / Roof 49.00 Ductwork(unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.29 Door 0.29. . CoolingHeating& Heating System: Cooling System: Water Heater: Name: Date:. Comments.