2004-617 *j TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
-. Community Development - Building & Codes (518) 761-8256
- ERTIFICATE OF, -.00CUPANCY
- _ Permit:Number. P20040617 _ _ :DaW ssifi .; :Tuesday, November 15, 2005
_This is ftd_certify that requested:to-berdone as shown by Permit Number P20040617
_ has been completed.
-
__ Tax.Map-Number:;
- - _ 523400-295-014-0002=027-000-0000
Location:- -__ 116 MT. VIEW Ln
Owner:_- _ - :. ; STANLEY &DORIS-KOSINSKI
APplicant:,._ KEITH KOSINSKI. _
This structure may be occupied as a:
_ Garage - 2 Cars Attached __ By Order of Town Board
_._ Residential Addition .:_--:. - TOWN OF QUEENSBURY
Issuance bf this-Certificate of Occupancy DOES NOT relieve the
owner of the-res onsibili for compliance with Site Plan ►
property P tY P
Variance,-or other--issues and conditions as a result-of-approvals-by-the Director of Building&code Enforcement
- Planning Board or Zoning Board of Appeals.
T TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20040617 Application Number: A20040617
Tax Map No: 523400-295-014-0002-027-000-0000
Permission is hereby granted to: STANTYX&DORTS KOSTNSKT
For property located at: 116 MOUNTAIN VIEW Ln
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: STANLEY&DORIS KOSINSKI
150 AVIATION Rd Garage-2 Cars Attached
QUEENSBURY NY 12804 Residential Addition $40,000.00
Total Value $40,000.00
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2004-617
200 SQ FT RESIDENTIAL ADDITION WITH 2-CAR ATTACHED GARAGE
$217.20 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,August 17, 2005
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Ton n:7 Ted ,August 17, 2004
SIGNED BY for the Town of Queensbury.
Director of Building&Gfode En orcement
1
Building Permit AppUcation
k Town of Queensbury-Dept of Community Development,742 Bay Road,Queennsbury,NY
(518)761.8256
A permit must be obtained before beginning construction. Permit Mq No. C2U -6011
No ii-�ssppection will be made until appliomt has re.oeived a Fee Paid S
permit. An applicants spaoes on this
valid building ' Reo.Fee Paid $�
application must be completed and must appear on the Reviewed By:� =_ !
application form. v'Y
' Applicant: P 14k l oS10 5 ti Owner:
- Kslg s�, `
Address: Address• /o^
Phone#(VS:) -• ! Phone# 621 ) `-
Property Location. Lot Number. / House Number,��,,
06M44t�ff)
SubdivisionName: Tax Map 1 u ber and 2-,2 7
residence /commercial 'Estimated Market Value of Construction:
o/New Building- Arjo�.,..
t�f Addition: residence 1 commercial if sh Addition,what will use of new addition o?
Alteration: residence! commercial '
o No change to exterior size: residence/com'1 L S.
o Otherwbrk(describo
Check I Occupsmeywormation i� Ploor 2""
Floor Other floor Total
Below 'Tit. sq.St, sq.ft• amz 01.e.Feat
single
farrlil dwellin tv' il
C Two family dwellin
0 Townhouse
o MUMIamily dwelling
#of units______
o OfSce
0 Memaattlo" -
o Meaufaotu::rlxn
0 1 ccddwhed Otago.
0 2 car detached imge TOWN OF QUEE SBURY
CO L 3 car detached swage
0 I oar attached g=ge
Mr 2 on attachedVast 1 '7 Rq I
0 3 ca:aftebed g=ge
0 Storage building-
comsnercial
o Storage building-
residential
o. O er
What is the proposed height of the structure �� lest -inches
Will any sdeond-hand or ungraded Iumber be used? If so,for what? Ma -• elca ;1OCYL
Type of Heating System: electric/ oil gas)/wood /forced hot air baseboard/other:
Number of 'l�eblac¢s to be it1#11ed Number'of ffggd cvej to be installed
List below the person(s)responsible for supervision of work as regards to building codes:
-de e �
--N'�e -- Address _ _ � , PhotcNumbof �• qq bg
Builder e� • n!5 .� / 7
Plumber
Mason r�, ►� t
Blectr'ician 6r5 z
r �
eo ration: please sign.below after you have carefully read the statement:
To the best of my knowledge the statements contained in this application,together with the plans and specifications
submitted,axe a true and complete statement of all proposed work to be done on the cloacribed premises and that all
provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be oomplied Y, .
with,whether specified or noted,and that such work is authorized by the owner, Further,'it is"understood that Vwe shall/-
submit,prior to a CdrtMoste of Occupancy or Ceraficate:of Compliance being issued,as requestedby the Zoning
Adminiatzator or Director of Building and Codes,as by a licensed surveyor;drawn to scale,-showing actual
location of ew construatto 1
Signature• - — owner,owner's agent,architect,contractor
ENERGY CODE COMPLIANCE APPLICATION
TOWN OF QUEEN'SBURY, WARREN COUNTY
9000 BEATING DEGREE DAYS
Compliance Methods:Part 5 -Acceptable Practice Method—1&2 Family Dwellings(only)
Part 6*-Thermal Rating—Component trade Offs 1&2 Family Dwelling,
Multi-Family Dwellings(3 Stories or less)
Part 4*-Design by Component Performance,Commercial Buildings-FE
Rise Residential
*Requires submission of worksheets
APPLICANT'S NAME: PROPERTY LOCATION:
PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE:
1. Gross Floor Area square feet
2. Type of heat- Electric . Oil Gps Other
3. Is building mechanically cooled? yes No
4. Percentage of area of windows and doors Over 17% Under 171/o
5. R-VALUES FOR MULATION GIVEN BELOW MUST CORRESPOND TO R VALUES AS
SHOWN ON PLANS SUBMITTED:
a: Roof R�
b. Exterior walls R__� _
C. Glazed areas R
d. Exterior doors R
e. Floors over unheated spaces R�
f. Edge of slab on grade(heated building) R RECEIVED
g. Basement/cellar walls(above grade) R
h. Basement/cellar walls(below grade) R AUG 0 9 2004
i. Heatinglwoling-ducts-piping in unheated space R TOWN OF QUEENSBURY
6. Service(domestic)hot water heating device BUILDING AND CODE
Conforms to minimum efficiency per code Yes No
TEMPERATURE CONTROL MAXIMUM SETTING 140—WILL NOT BE EXEEDED
pli is Nig ature Dat Phone Number
INSPECTOR'S REMARKS:
t
617
F Check Residential Plan Review: One&Two Family Dwellings
YIN/N/A
(2)Full sets of plans
Over 1,500 sq. ft.—Stamped
Design Loads On Plans: 90 Wind Floor Loads 40 psf
70 Ground Snow Load Sleeping Areas and Attics 30 psf
Calculations:
Wi dow Schedule With Glass Size ,
Vm
rSchedule/Main Entrance X'Door
ergency Escape Or Bedrooms and Habitable Space
Above/Below grade,5.7 sq.ft.
Grade,5.0 sq. ft.
24"(h)x 20"(w)min.
44"Max.Height above floor
Residential Check Paperwork Compliance and Inspectors Checklist: OK
Dampproofmg/Waterproofing Materials On Plans
Foundation Drainage On Plans,if required
6"Drop in 10' Exterior Grade
naming Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where
e uired
Iee and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls
AA, Platforms At Exterior Doors
Stairway Headroom 6' 8'All Stairs 36"Width
Stair Run and Rise
Winder Run and Rise
Spiral Not Allowed From 2n Story
i moke Detectors Battery Backup and Proper Location
V�gathroom Fixtures Proper Clearance
all Width,36"min.
Handrails More Than One Riser On Open Sides
Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht.
Safety Glazing Notes For Required Areas
arage Fire Separation
Garage Floor Sloped
Attic Access
Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access
Carbon Monoxide Detector Lowest Sleeping Level
Soil Test Results, if required
Septic To Well Or Water Line Separation
All Paperwork Signed
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518)761-8256 Arrive: am/pm Depa am/pm
Date Inspection request received: _ Inspector's Initials:
NAME: PERMIT#: —
LOCATION: DATE: --
TYPE OF STRUCTURE:
Comments �, A
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location 7
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches r
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors: ii 3r F-4
Every level: Every Bedroomtc—(h._G aye
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp, 110
Enclosed Stairs Sheetrock Underside minimum%"Gypsum
asement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/4 hour fire door/door closer i
Duct work Sealed properly
Gas Logs in Sealed or Gl ss Fjiglogire
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/O [Temporary/Permanent]
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc
FILE COPY
Bldg. Permit .File No. C�;O�_W 7
Final
0
Inspection
Approva. 1
I COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 176 Doe Run Road-Manheim,PA 17545
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
�[, 0
Permit No...............::�1/.....Cert. N_ 93333 Cut-in Card No.....................................
Owner................. ........ ..........................................................................................
Location..............1<.LAG.......M..T...... .�I.--i......�.o....................................................................................
Installation Consisting of....... .......1 rY../L. .4�.....:.� wj................
�.�.....�..T..S�.......5..1.. I.........iL.A. .?Q.a. .J1sf............................................................
....................................................................................................................................................................................
Installed ................................................Lic.No...................................................
The conditions following governed the issuance of this certificate,and any certificate previously issued is
L:1 cancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations,application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of making inspections at any time, and if its
rules are violated,the Company shall have the right to revoke this certificate.
Date.......1..1^..1.�.-.Q..,S............... INSPECTOR--£?.�.............. .... . ........ ..........................................
Member N.F.P.A.,I.A.E.I.
Queensbury Building & Code Enforcement - Residential Final Ins ection
f
Office No.(518)761-8256 Arrive: am/pm e art�� pm
Date Inspection request received: _ Z U� Inspector's Initials: _
NAME: os ti (� , PERMIT#: 0 L LP
LOCATION: P IM-k klL(.uj _ DATE: (�
TYPE OF STRUCTURE: _
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6"
Roof Complete/Exterior Finish Complete
Guard 30 in.or more @ stairs,decks,patios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in. or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum
Gypsum
Grade away from foundation 6 in.with 10 ft.
Handrail.Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft.or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Interior privacy/trim/doors/main entrance 36 in. ool
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safetyglazing
Interior Smoke Detectors:
6A fek�&� % ��-�, dUo�" 4A/Z/V„ �j
Interior
Every level: / Every Bedroom:
Outside every bedroom area: ✓
Inter Connected: / Battery backup:
Carbon Monoxide Detector
Bathroom Fans, if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade % t�E-`�Basement stairs closed rise>4 inches H f m
Garage Floor Pitched �iP 6C PIA,_
Garage fireproofing/'/<hour fire door/door closer
Duct work Sealed properly ))
Gas Logs in Sealed or Glass Enclosure C NF��u— y � (f�K • ����' �'�
Attic access 30 in.x 22 in,x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24'-'access, 1 s . ft.-150 s . ft.vents
Building No./Address visible from road
Final Electrical
Site Plan /Variance required N1�'F7 �rnl�L
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Flood Plain Certification, if required
ka to issue C/C or C/0-[Temp orar /Permanent
L:\PamW\Building&CodesUnsvection Forins\Res. Final Insn. form 2.docLast printed 2/12/04
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection r2qe v
Queensbury Building & Code Enforcement Arrive: W-op e rt: A a m742 Bay Road, Queensbury, NY 12804 Inspector's InNAME: W-O6��J��\ PE #: H-b
LOCATION: INSPECT ON: 1:i�- zu-��
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent/ Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet / change of direction
Pressure Test
Drain / Vent
Air/ Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/ Head
50 P.S.I for 15 minutes
Insulation / Residential Check/ Commercial Check
Proper Vent Attic Vent
Duct/ Hot.Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/ No duct tape
COMMENTS:
LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003,doc Revised February 15,2005
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: 3 rcJ am/pm Depart: am- m
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
�f
NAME: PERMIT #:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
10
�rn
Y N N/A
Rough Plumbing / Nail Plates
Plumbing Vent/ Vdnts in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/ change of direction
Pressure Test
Drain / Vent
Air/ Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
W er Supply Piping
/ Head
0 P.S.I for 15 minutes
09
nsulation / Residential Check/ Commercial Chec
Proper Vent Attic Vent
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
COMMENTS:
LAPam Whiting\Building&CodesUnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005
Framing/ Firestapping Irispection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/ in Depart P
742 Bay Road, Queensbury,NY 12804 :Inspector's Initials: '�
NAME: d S �. S PERMIT#:
LOCATION: Alf y2tT INSPECT ON: 3 5
TYPE OF STRUCTURE: _ A1LnrPz
Y N N/A Framing COMMENTS
Attic Access 22"x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/z "w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Tres op ip i l
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side ''/z inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Queensbury Building & Code Enforcement - Residential Final Inspection -P'f-dc'
Office No.(518)761-8256 Arrive: c2 W am/pm Depart: am/pm
Date Inspection request received: Inspector's Initials:
NAME: (G PERMIT#:
LOCATION: _ 1G-Cj �_N , _ DATE: Z _
TYPE OF STRUCTURE:
Comments
Y N N/A 9 _ G
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6" C
Roof Complete/Exterior Finish Complete /
Guard 30 in.or more @ stairs,decks,patios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in. or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum %"
Gypsum
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft.or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Interior.privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
i
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: / Battery backup:
Carbon Monoxide Detector
Bathroom Fans, if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
B ement stairs closed rise>4 inches
rage Floor Pitched
Gara a fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area �( �
Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft. vents �- dec _�
BuildingNo./Address visible from road e Gll�C�1 J��
Final Electrical
Site Plan /Variance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept. Inspection Sticker
Flood Plain Certification, if required
Okay to issue C/C or C/O Temporary/Permanent
L:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No.(518)761-8256 Arrive: am/1 D part: bam/pm
Date Inspection request received: _ Inspector's Initials: �1
NAME: �'C(9S l/J �,�L-1 PERMIT#:
LOCATION: (�l J DATE: 2 0_5
TYPE OF STRUCTURE:
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6"
Roof Complete/Exterior Finish Co m lete
Guard 30 in.or more a)stairs,decks patios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in. or more j 7
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors its`��i
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum
Gypsum
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade ®
Gas Furnace shut-off within 30 ft. or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Tern 110
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen waterti ht
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors: roe
Every level: / Every Bedroom: I c��l, `Outside every bedroom area: r
Inter Connected: / Battery backup:
Carbon Monoxide Detector -
Bathroom Fans, if no window auc—
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below rade
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, 1 s . ft,150 s . ft.vents
Building No./Address visible from road
Final Electrical
Site Plan /Variance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Flood Plain Certification, if required
Okay to issue C/C or C/O Temporary/Permanent
L:\PamWlBuilding&CodeslInspection FortnslRes. Final Insp. form 2.docLast printed 2/12/04
Framing / Firestopping Inspection Report
/�A
Office No. (518) 761-8256 Date Inspection request received: 17 � A
Queensbury Building& Code Enforcement Arrive: _am/p ' epart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: l ,A)s C PERMIT#: ✓���
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A COMMENTS
Framing - 2 pp
Tack Studs/Headers 101,--�LLT� Uc7�� CP`p)�
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly fc-
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %z (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
ire wall 2, 3, 4 hour
Firestopping
" Penetration sealed � � l
16 inch insulation in cavity min.
Garage Fire Separation
House side %inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No.(518)761-8256 Arrive: am/ Depart; - "�am/pm
Date Inspection request received: Inspector's Initials:
NAME: D i PERMIT#: 7
LOCATION: itJ•- DATE: 5
TYPE OF STRUCTURE: _
_ Comments
Y 1 ,N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6"
Roof Complete/Exterior Finish Complete
Guard 30 in.or more @ stairs,decks,patios i�i� f'i�— ��1 y 5U�►2��
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in. or more >4 S tSL U SSA C7
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers '
Enclosed Stairs Sheetrock Underside minimum %2"
Gypsum
Grade away from foundation 6 in, with 10 ft.
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft. or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom: '
Outside every bedroom area:
Inter Connected: ! Battery backup:
Carbon Monoxide Detector
Bathroom Fans, if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
Garage Floor Pitched �btl LPe—
Garage fireproofing/'/<hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents
Building No./Address visible from road
Final Electrical �'�� �(�✓A c- GGG� .
Site Plan /Variance required
Final Survey Plot Plan ,
As Built Septic System/Sewer Dept. Inspection Sticker
Flood Plain Certification, if required
[Ok—ay to issue C/C or C/O Temporary/Permanent
L:\PamW\Building&Codes\Inspection Forms\Res, Final Insm form 2.docLast printed 2/12/04
Rough Plumbing / Insulation InspectionReportl �
Office'No. (518)761-8256 Date Inspection request received:.
Queensbury Building&Code Enforcement Arrive: am/p�a am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT #: 0 (j-1eL7
.
LOCATION: M' INSPECT ON: --
TYPE OF STR CTURE. `
Y N N/A
PVC: R-1,R-2,R-3,R4 Drain/Vents
Cast Ir n, Copper Drain/Vent/Comm.
PIHWlhg Vent/Vents in Place
ou Plumbin /Nail Plates
1 % inch min. Drain Size
Washing Machine Drain 2 inch min.
ead or Air Supply Test
Drain and Vents
-5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water,Supply Piping
Cooper Commercial
Cooper,CPVC,Pex One and Two-Family
Insulation/Residential Check/Commercial Check
Proper er Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed.jRroperly/No duct tape
COM NTS:
L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003
Rough Plumbing / Insulation Inspection Report
� p �c
Office No. (518) 761-8256 Date Inspection request received: '
Queensbury Building& Code Enforcement Arrive: am/p e a ' am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials: \ �� _ f
NAME: PERMIT #:
LOCATION: IN PEC ON. --
TYPE OF STR CTURE: `
Y N N/A
PVC: R-1,R-2,R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
P inew Vent/Vents in Place
_e iu -Plumbin -/Nail Plates
1%z inch min. Drain Size
Washing Machine Drain 2 inch min.-
ead or Air Supply'Pest
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
'Wiier.,Supply Piping
Cooper Comiriercial
Cooper, CPVC,Pex One and Two-Famil
Insulation/Residential Check/ Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air S!!pply for Furnace
Duct work sealed properly/No duct tape
COM NTS:
G. '2) U )p �A
L:\SueFlemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003
Rough Plumbing / Insulation Inspection Report
Office No. (51 8) 761-8256 Date Inspection request received: ,
Queensbury Building& Code Enforcement Arrive: am/wn De - am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: fi c (pS PERMIT #:
LOCATION: L INSPECT ON:
TYPE OF STRUCTURE:
Y let N/A
PVC: R-1,R-2,R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/ Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 % inch min.Drain Size
W shin Machine Drain 2 inch min.
ead or Air Supply Test
v Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
Cooper,CPVC,Pex One and Two-Tamil
Insulation/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
LASueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: j am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: +`(T.S/ i/ PERMIT#:
LOCATION: /YJ� U INSPECT ON:
TYPE OF STRUCTURE:
Y N` N/A Framing COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %z (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping'
Penetration sealed
ti
16 inch insulation in cavity min.
Garage Fire Separation
House side %inch or 5/8,inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LASueHemingway\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003
i
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building& Code Enforcement Arrive: Vw am/pm Depart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials: /Z
NAME: PERMIT #: t�
LOCATION: ) INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2, R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 % inch min.Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanont every 100 feet/change of direction'
Water Supply Piping
Cooper Commercial
o er, CPVC,Pex One and Two-Family
,� sulation/Residential Check/ Commercial Check CC
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Fuirnace
Duct work sealed properly/,No duct tape
COMMENTS:
LASueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing insulation Report.doc November 17,2003
Framing / Firestoppirig Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: arn/p D part: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: 4
NAME: PERMIT#: O I
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A COMMENTS
Framing
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping,for Notches Top Plate
1 2 (w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Le\SueHemingway\Building.Codes.In spec tion.FORM S\Framing Firestopping Inspection Report.doc January 28,2003
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received: n
Queensbury Building& Code Enforcement Arrive: _arn/ De am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initial
NAME: PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A COMMENTS
� �)-tea
Jack Studs/Headers
Bracing/Bridging i✓�j r,Q�LC, iCJ/Z� �O�
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire si eparation 1, 2, 3 hour
F re wall 2, 3, 4 hour
a irtVstopping DW�
Penetration sealed f
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LASueHemingw•ay\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: _ _
Queensbury Building&Code Enforcement Arrive: an-/pm Depart: -am/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:
NAME: _ �ce,1 to PERMIT#:
LOCATION: _ , , I `L _ INSPECT ON: I o .
TYPE OF STRUCTURE:
Comments
N NIA
Piers
Monolithic Slab
Reinforcement in Place
The contractor is respon-ble �r
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfrll Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\SueHemingway\Building.Codcs.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: a m
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: CI
NAME: kle, �� s �' PERMIT#:
LOCATION: / INSPECT ON: 0
TYPE OF STRUCTURE: r
Comments
Y N /A
ootl /�
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/ Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
LASueHemingway\nuii ding.Codes.InspectionTORMSToundation Inspection Report.doc Januaiy 28,2003
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection request received.
Queensbury Building& Code Enforcement Arrive: am/p epart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
f_
NAME: S PERMIT#: (� .. (�
LOCATION: M T , / ; Lt.,] �+.}-r`r� INSPECT ON:
TYPE OF STRUCTURE:
Y Framing N N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 (w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 .
Rough Plumbing / Insulation Inspection Report
Office No. (518)761-8256 Date Inspection request received: ,
Queensbury Building& Code Enforcement Arrive: am/p epart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: f/oli PERMIT #: (P
LOCATION: IAA r. L--,I, INSPECT ON: II !� a,
TYPE OF STRUCTURE:
Y N N/A ke_G 6 GIC.
PVC: R-1,R-2,R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 % inch min. Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/chan a of direction
Water Supply Piping
Cooper Commercial
Cooper, CPVC,Pex One and Two-Family
Insulation/Residential Check/Commercial Check
Proper Vent, Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doe November 17,2003
L(
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building& Code Enforcement Arrive: am/pin ppe�part: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials. `�
NAME: PERMIT #:
LOCATION: �� d'1\ � � ;,,�,�' ���� INSPECT ON: -�
TYPE OF STRUCTURE:
Y N NIA
PVC: R-1,R-2,R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 % inch min. Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest , l
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping I L �
Cooper Commercial g
o er, CPVC, Pex One and Two-Family
sulation/Residential Check/ Commercial Check
-Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS: �-
�U rF �'V(.vcEloc�S
LASueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: i
Queensbury Building& Code Enforcement Arrive: am/pr>I Depart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials: 3
NAME: klo-.5 1A)- /--/l PERMIT #: ® �7
LOCATION: )/6 mr, ICE✓ •U . INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1, R-2, R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/ Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
1 % inch min. Drain Size
Washing Machine Drain 2 inch min.
Mead or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
Cooper, CPVC,Pex One and Two-Family
Insulation/Residential Check/ Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air S!ipply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
LASueHemingwa}\Building.Codes.Inspection.FORM STough Plumbing Insulation Report.doc November l7,2003
14
31
Framing / Firestopping Inspec n Report ��
Office No. (518) 761-8256 Date Inspection request received: 11 et
Queensbury Building&Code Enforcement Arrive: _a pm' fDepart:: m/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials<:N . E
t . _
NAME: ;S 1 LS PERMIT#: 17
LOCATION: INSPECT ON: 1/
TYPE OF STRUCTURE: 6 -_
� Framing
/ COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall/
Fire separation 1, 2, 3 hour /
i wall 2, 3, 4 hour /
�
".Firestopping,.-.- .-.. _ .
netrati n led
inch insulation in caXtymin.
Garage Fire Separation
House side %inch o 5/8 inch Type X
Garage side 5/8 i jc`h Type X
Ceiling/wail1
Windows Habitable Space/Bedrooms
24 in. (H).%
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemin-,way\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: t),v /,2ev f
Queensbury Building&Code Enforcement Arrive: am/lq?7�
am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:
NAME: �51�s�\ PERMIT #: 7
LOCATION: �1 ' INSPECT ON: NOV.
TYPE OF STRUCTURE:
Y N Nhir
PVC: R-1,R-2,R-3,R4 Drain/Vents
Cast Iron, Copper Drain/Vent/Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates 411/0 �c� b
1 % inch min. Drain Size
Washin 2 inch min. G (.5
G—
He or Air Supply Test
Drain and Vents ��
5 PSI or 10 feet ove highest UlJ
on for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
Cooper, CPVC,Pex One and Two-Fanul
Insulation/Residential Check/ Commercial C eck
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation Z
If re uired unheated s aces
Combustion Air Supply for Furnace
Duct work sealed properl /No ductlea e
i
COMMENTS:
f
�l
LASueHemingway\Building.Codes.Inspection.FORM S\Rough Plumbing Insulation Report.doc November 17,2003
Rough Plumbing / Insulation Inspection Report
Office No. (51 8) 761-8256 Date Inspection request received:
Queensbury Building& Code Enforcement Arrive: m Pepart: am/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials
NAME: PERMIT #: C_�L- 6/)
LOCATION: � ` ` I L—QmINSPECT ON: /
TYPE OF STRUCTURE:
Y N N/A
PVC: -1,R-2,R-3,R4 Drain/Vents
Ca Iron, Copper Drain/Vent/Comm.
Ambing Vent/Vents in Place
ou h Plumbing/Nail Plates
1 1/z inch min..Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
Cooper,CPVC,Pex One and Two-Family
Insulation/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
LASueHemingway\Building.Codes.Inspection.FORM S\Rough Plumbing Insulation Report.doc November 17,2003
Framing / FirestoPP g in Inspection Report
P P
Office No. (518) 761-8256 Date Inspection request received: ,A a _,.
Queensbury Building& Code Enforcement Arrive: _ai e art: am/p
,-
742 Bay Road, Queensbury, NY 12804 Inspector's Initials
NAME: C I PERMIT#:
LOCATION: 'I n Mo '\'a PA ) INSPECT ON: -U!J
TYPE OF STRUCTURE: 1
Y N ' N/A COMMENTS
TS
�r�a�rn�ing:- I
Jack Studs/Headers
C_
Bracing/Bridging 1—
Z�
Joist hangers LA, `
Jack Posts/Main Beams rU Le-t1
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in. ����`�/ �` � ,Q_•CCC�
Stairwells 36 in. or more 1
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/2 (w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
>Fi--resto in j
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
/ A,
Framing / Firestopping nspectio Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building& Code Enforcement Arrive: _ arri/pm Depart:
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: Cl ;L� I XJsi�S k� PERMIT#:
LOCATION: INSPECT ON: O a
TYPE OF STRUCTURE: i
Y N N/A COMMENTS
(f Framin
Jack Studs/Headers
Bracing/Bridging s�J
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C. _
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %z (w) 16 gauge (8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Z�_q
Ice and snow shield 24 inches from wall2 5b
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side % inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
I
r
vv
-A CWO
_ f
S' 5"1 fib 21
I
/ I
a
X/��
76p
N - -2 7
q0o
� �� JJ is �
f
Permit Number
REScheck Compliance Certificate . Checked By/Date
New York State Energy Conservation Construction Code-
REScheckSoftware Version 3.5 Release la
Data filename: C:\Program Files\Check\REScheck\07604 KOSINSKI-MOUNTAIN VIEW,QUEENSBURY.rck
TITLE:PLAN NO.07604
COUNTY:Warren
STATE:New York
HDD: 7635 RECEIVED
CONSTRUCTION TYPE:Detached 1 or 2 Family
HEATING TYPE:Non-Electric
DATE:08/11/04 AUG 1 20��
DATE OF PLANS:JULY 30,2004 TOWN OF: QUEENSBURY
BUILDING AND CODE
PROJECT INFORMATION:
KEITH&SHIRLEY KOSINSKI
MOUNTAIN VIEW LANE
QUEENSBURY,NEW YORK 12804
COMPANY INFORMATION:
WILLIAMS&WILLIAMS DESIGNERS
509 GLEN STREET
GLENS FALLS,NEW YORK 12801
COMPLIANCE:Passes
Maximum UA=251
Your Home UA=222
11.6%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont. or Door
Perimeter 'R-Value R-Value U-Factor UA
Ceiling 1:Cathedral Ceiling(no attic) 945 38.0 0.0 26
Ceiling 2:Cathedral Ceiling(no attic) 637 38.0 0.0 17
Wall 1:Wood Frame, 16"o.c. 1111 19.0 0.0 59
Window 1:Wood Frame:Double Pane with Low-E 70 0.320 22
Door 1: Solid 60 0.130 8
Wall 1 Wood Frame, 16"o.c. 565 19.0 0.0 21
Window 2:Wood Frame:Double Pane with Low-E 174 0.320 56
Door 2:Glass 40 0.330 13
Furnace:I:Forced Hot Air,85 AFUE
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,
specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the
New York State Energy Conservation Construction Code requirements. When;a Registered Design Professional has stamped and
signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or
specifications are in compliance with this Code.
Build Designe Date
s i
REScheck Inspection Checklist
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release la
DATE: 08/11/04
TITLE:PLAN NO.07604
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Cathedral Ceiling(no attic),R-38.0 cavity insulation
Comments:
[ ] 2. Ceiling 2:Cathedral Ceiling(no attic),R-38.0 cavity insulation
Comments:
Above-Grade Walls:
[ ] 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
[ ] 2. Wall 2:Wood Frame, 16" o.c.,R-19.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1:Wood Frame:Double Pane with Low-E,U-factor: 0.320
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? [ ]Yes [ ]No
Comments:
[ ] 2. Window 2:Wood Frame:Double Pane with Low-E,U-factor: 0.320
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? [ ]Yes[ ]No
Comments:
Doors:
[ ] 1. Door 1: Solid,U-factor: 0.130
Comments:
[ ] 2. Door 2:Glass,U-factor:0.330
Comments:
Heating and Cooling Equipment:
[ ] 1. Furnace 1:Forced Hot Air,85 AFUE or higher
Make and Model Number
Air Leakage:
[ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] I Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly
with a 0.5"clearance from combustible materials. If non-IC rated,the fixture must be installed with a
3"clearance from insulation.
Vapor Retarder:
[ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
[ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11.
[ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6.
[ ] Supply ducts in unconditioned spaces must be insulated to R-11.
[ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2.
Insulation is not required on return ducts in basements.
Duct Construction:
[ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
(adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
operating at less than 2 in.w.g.(500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior.insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
temperature set point of the largest zone.
Electric Systems:
[ ] Separate electric meters are required for each dwelling unit.
Fireplaces:
[ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
provisions of the Building Code of New York State ,the Residential Code of New York State or
the New York City Building Code ,as applicable.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
J 40-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVACPipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD (Building Department Use Only)