Loading...
2004-617 *j TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 -. Community Development - Building & Codes (518) 761-8256 - ERTIFICATE OF, -.00CUPANCY - _ Permit:Number. P20040617 _ _ :DaW ssifi .; :Tuesday, November 15, 2005 _This is ftd_certify that requested:to-berdone as shown by Permit Number P20040617 _ has been completed. - __ Tax.Map-Number:; - - _ 523400-295-014-0002=027-000-0000 Location:- -__ 116 MT. VIEW Ln Owner:_- _ - :. ; STANLEY &DORIS-KOSINSKI APplicant:,._ KEITH KOSINSKI. _ This structure may be occupied as a: _ Garage - 2 Cars Attached __ By Order of Town Board _._ Residential Addition .:_--:. - TOWN OF QUEENSBURY Issuance bf this-Certificate of Occupancy DOES NOT relieve the owner of the-res onsibili for compliance with Site Plan ► property P tY P Variance,-or other--issues and conditions as a result-of-approvals-by-the Director of Building&code Enforcement - Planning Board or Zoning Board of Appeals. T TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040617 Application Number: A20040617 Tax Map No: 523400-295-014-0002-027-000-0000 Permission is hereby granted to: STANTYX&DORTS KOSTNSKT For property located at: 116 MOUNTAIN VIEW Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: STANLEY&DORIS KOSINSKI 150 AVIATION Rd Garage-2 Cars Attached QUEENSBURY NY 12804 Residential Addition $40,000.00 Total Value $40,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2004-617 200 SQ FT RESIDENTIAL ADDITION WITH 2-CAR ATTACHED GARAGE $217.20 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,August 17, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Ton n:7 Ted ,August 17, 2004 SIGNED BY for the Town of Queensbury. Director of Building&Gfode En orcement 1 Building Permit AppUcation k Town of Queensbury-Dept of Community Development,742 Bay Road,Queennsbury,NY (518)761.8256 A permit must be obtained before beginning construction. Permit Mq No. C2U -6011 No ii-�ssppection will be made until appliomt has re.oeived a Fee Paid S permit. An applicants spaoes on this valid building ' Reo.Fee Paid $� application must be completed and must appear on the Reviewed By:� =_ ! application form. v'Y ' Applicant: P 14k l oS10 5 ti Owner: - Kslg s�, ` Address: Address• /o^ Phone#(VS:) -• ! Phone# 621 ) `- Property Location. Lot Number. / House Number,��,, 06M44t�ff) SubdivisionName: Tax Map 1 u ber and 2-,2 7 residence /commercial 'Estimated Market Value of Construction: o/New Building- Arjo�.,.. t�f Addition: residence 1 commercial if sh Addition,what will use of new addition o? Alteration: residence! commercial ' o No change to exterior size: residence/com'1 L S. o Otherwbrk(describo Check I Occupsmeywormation i� Ploor 2"" Floor Other floor Total Below 'Tit. sq.St, sq.ft• amz 01.e.Feat single farrlil dwellin tv' il C Two family dwellin 0 Townhouse o MUMIamily dwelling #of units______ o OfSce 0 Memaattlo" - o Meaufaotu::rlxn 0 1 ccddwhed Otago. 0 2 car detached imge TOWN OF QUEE SBURY CO L 3 car detached swage 0 I oar attached g=ge Mr 2 on attachedVast 1 '7 Rq I 0 3 ca:aftebed g=ge 0 Storage building- comsnercial o Storage building- residential o. O er What is the proposed height of the structure �� lest -inches Will any sdeond-hand or ungraded Iumber be used? If so,for what? Ma -• elca ;1OCYL Type of Heating System: electric/ oil gas)/wood /forced hot air baseboard/other: Number of 'l�eblac¢s to be it1#11ed Number'of ffggd cvej to be installed List below the person(s)responsible for supervision of work as regards to building codes: -de e � --N'�e -- Address _ _ � , PhotcNumbof �• qq bg Builder e� • n!5 .� / 7 Plumber Mason r�, ►� t Blectr'ician 6r5 z r � eo ration: please sign.below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,axe a true and complete statement of all proposed work to be done on the cloacribed premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be oomplied Y, . with,whether specified or noted,and that such work is authorized by the owner, Further,'it is"understood that Vwe shall/- submit,prior to a CdrtMoste of Occupancy or Ceraficate:of Compliance being issued,as requestedby the Zoning Adminiatzator or Director of Building and Codes,as by a licensed surveyor;drawn to scale,-showing actual location of ew construatto 1 Signature• - — owner,owner's agent,architect,contractor ENERGY CODE COMPLIANCE APPLICATION TOWN OF QUEEN'SBURY, WARREN COUNTY 9000 BEATING DEGREE DAYS Compliance Methods:Part 5 -Acceptable Practice Method—1&2 Family Dwellings(only) Part 6*-Thermal Rating—Component trade Offs 1&2 Family Dwelling, Multi-Family Dwellings(3 Stories or less) Part 4*-Design by Component Performance,Commercial Buildings-FE Rise Residential *Requires submission of worksheets APPLICANT'S NAME: PROPERTY LOCATION: PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE: 1. Gross Floor Area square feet 2. Type of heat- Electric . Oil Gps Other 3. Is building mechanically cooled? yes No 4. Percentage of area of windows and doors Over 17% Under 171/o 5. R-VALUES FOR MULATION GIVEN BELOW MUST CORRESPOND TO R VALUES AS SHOWN ON PLANS SUBMITTED: a: Roof R� b. Exterior walls R__� _ C. Glazed areas R d. Exterior doors R e. Floors over unheated spaces R� f. Edge of slab on grade(heated building) R RECEIVED g. Basement/cellar walls(above grade) R h. Basement/cellar walls(below grade) R AUG 0 9 2004 i. Heatinglwoling-ducts-piping in unheated space R TOWN OF QUEENSBURY 6. Service(domestic)hot water heating device BUILDING AND CODE Conforms to minimum efficiency per code Yes No TEMPERATURE CONTROL MAXIMUM SETTING 140—WILL NOT BE EXEEDED pli is Nig ature Dat Phone Number INSPECTOR'S REMARKS: t 617 F Check Residential Plan Review: One&Two Family Dwellings YIN/N/A (2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Wi dow Schedule With Glass Size , Vm rSchedule/Main Entrance X'Door ergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq. ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofmg/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6"Drop in 10' Exterior Grade naming Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where e uired Iee and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls AA, Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise Winder Run and Rise Spiral Not Allowed From 2n Story i moke Detectors Battery Backup and Proper Location V�gathroom Fixtures Proper Clearance all Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas arage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm Depa am/pm Date Inspection request received: _ Inspector's Initials: NAME: PERMIT#: — LOCATION: DATE: -- TYPE OF STRUCTURE: Comments �, A Yes No N/A Building Number/Address visible from road Chimney Height/"B"Vent/Direct Vent Location 7 Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches r Roof Complete/Exterior Finish Complete Platform at all exterior doors Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Interior Handrails @ stairs 2 or more risers Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: ii 3r F-4 Every level: Every Bedroomtc—(h._G aye Outside every bedroom area: Inter Connected: Battery backup: Carbon Monoxide Detector Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp, 110 Enclosed Stairs Sheetrock Underside minimum%"Gypsum asement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer i Duct work Sealed properly Gas Logs in Sealed or Gl ss Fjiglogire Final Electrical Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C/O [Temporary/Permanent] L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc FILE COPY Bldg. Permit .File No. C�;O�_W 7 Final 0 Inspection Approva. 1 I COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL �[, 0 Permit No...............::�1/.....Cert. N_ 93333 Cut-in Card No..................................... Owner................. ........ .......................................................................................... Location..............1<.LAG.......M..T...... .�I.--i......�.o.................................................................................... Installation Consisting of....... .......1 rY../L. .4�.....:.� wj................ �.�.....�..T..S�.......5..1.. I.........iL.A. .?Q.a. .J1sf............................................................ .................................................................................................................................................................................... Installed ................................................Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is L:1 cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making inspections at any time, and if its rules are violated,the Company shall have the right to revoke this certificate. Date.......1..1^..1.�.-.Q..,S............... INSPECTOR--£?.�.............. .... . ........ .......................................... Member N.F.P.A.,I.A.E.I. Queensbury Building & Code Enforcement - Residential Final Ins ection f Office No.(518)761-8256 Arrive: am/pm e art�� pm Date Inspection request received: _ Z U� Inspector's Initials: _ NAME: os ti (� , PERMIT#: 0 L LP LOCATION: P IM-k klL(.uj _ DATE: (� TYPE OF STRUCTURE: _ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum Gypsum Grade away from foundation 6 in.with 10 ft. Handrail.Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. ool Bathroom/Kitchen watertight Safety glazing/Window in stairwells safetyglazing Interior Smoke Detectors: 6A fek�&� % ��-�, dUo�" 4A/Z/V„ �j Interior Every level: / Every Bedroom: Outside every bedroom area: ✓ Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade % t�E-`�Basement stairs closed rise>4 inches H f m Garage Floor Pitched �iP 6C PIA,_ Garage fireproofing/'/<hour fire door/door closer Duct work Sealed properly )) Gas Logs in Sealed or Glass Enclosure C NF��u— y � (f�K • ����' �'� Attic access 30 in.x 22 in,x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24'-'access, 1 s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required N1�'F7 �rnl�L Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required ka to issue C/C or C/0-[Temp orar /Permanent L:\PamW\Building&CodesUnsvection Forins\Res. Final Insn. form 2.docLast printed 2/12/04 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection r2qe v Queensbury Building & Code Enforcement Arrive: W-op e rt: A a m742 Bay Road, Queensbury, NY 12804 Inspector's InNAME: W-O6��J��\ PE #: H-b LOCATION: INSPECT ON: 1:i�- zu-�� TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check Proper Vent Attic Vent Duct/ Hot.Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003,doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: 3 rcJ am/pm Depart: am- m 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: �f NAME: PERMIT #: LOCATION: INSPECT ON: TYPE OF STRUCTURE: 10 �rn Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vdnts in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test W er Supply Piping / Head 0 P.S.I for 15 minutes 09 nsulation / Residential Check/ Commercial Chec Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&CodesUnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing/ Firestapping Irispection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ in Depart P 742 Bay Road, Queensbury,NY 12804 :Inspector's Initials: '� NAME: d S �. S PERMIT#: LOCATION: Alf y2tT INSPECT ON: 3 5 TYPE OF STRUCTURE: _ A1LnrPz Y N N/A Framing COMMENTS Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z "w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Tres op ip i l Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side ''/z inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Queensbury Building & Code Enforcement - Residential Final Inspection -P'f-dc' Office No.(518)761-8256 Arrive: c2 W am/pm Depart: am/pm Date Inspection request received: Inspector's Initials: NAME: (G PERMIT#: LOCATION: _ 1G-Cj �_N , _ DATE: Z _ TYPE OF STRUCTURE: Comments Y N N/A 9 _ G Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" C Roof Complete/Exterior Finish Complete / Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior.privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing i Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade B ement stairs closed rise>4 inches rage Floor Pitched Gara a fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area �( � Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft. vents �- dec _� BuildingNo./Address visible from road e Gll�C�1 J�� Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/1 D part: bam/pm Date Inspection request received: _ Inspector's Initials: �1 NAME: �'C(9S l/J �,�L-1 PERMIT#: LOCATION: (�l J DATE: 2 0_5 TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Co m lete Guard 30 in.or more a)stairs,decks patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more j 7 Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors its`��i Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade ® Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tern 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen waterti ht Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: roe Every level: / Every Bedroom: I c��l, `Outside every bedroom area: r Inter Connected: / Battery backup: Carbon Monoxide Detector - Bathroom Fans, if no window auc— Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below rade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft,150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamWlBuilding&CodeslInspection FortnslRes. Final Insp. form 2.docLast printed 2/12/04 Framing / Firestopping Inspection Report /�A Office No. (518) 761-8256 Date Inspection request received: 17 � A Queensbury Building& Code Enforcement Arrive: _am/p ' epart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: l ,A)s C PERMIT#: ✓��� LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS Framing - 2 pp Tack Studs/Headers 101,--�LLT� Uc7�� CP`p)� Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly fc- 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour ire wall 2, 3, 4 hour Firestopping " Penetration sealed � � l 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/ Depart; - "�am/pm Date Inspection request received: Inspector's Initials: NAME: D i PERMIT#: 7 LOCATION: itJ•- DATE: 5 TYPE OF STRUCTURE: _ _ Comments Y 1 ,N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks,patios i�i� f'i�— ��1 y 5U�►2�� Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more >4 S tSL U SSA C7 Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers ' Enclosed Stairs Sheetrock Underside minimum %2" Gypsum Grade away from foundation 6 in, with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: ' Outside every bedroom area: Inter Connected: ! Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched �btl LPe— Garage fireproofing/'/<hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical �'�� �(�✓A c- GGG� . Site Plan /Variance required Final Survey Plot Plan , As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required [Ok—ay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res, Final Insm form 2.docLast printed 2/12/04 Rough Plumbing / Insulation InspectionReportl � Office'No. (518)761-8256 Date Inspection request received:. Queensbury Building&Code Enforcement Arrive: am/p�a am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT #: 0 (j-1eL7 . LOCATION: M' INSPECT ON: -- TYPE OF STR CTURE. ` Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Ir n, Copper Drain/Vent/Comm. PIHWlhg Vent/Vents in Place ou Plumbin /Nail Plates 1 % inch min. Drain Size Washing Machine Drain 2 inch min. ead or Air Supply Test Drain and Vents -5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water,Supply Piping Cooper Commercial Cooper,CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper er Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed.jRroperly/No duct tape COM NTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insulation Inspection Report � p �c Office No. (518) 761-8256 Date Inspection request received: ' Queensbury Building& Code Enforcement Arrive: am/p e a ' am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: \ �� _ f NAME: PERMIT #: LOCATION: IN PEC ON. -- TYPE OF STR CTURE: ` Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. P inew Vent/Vents in Place _e iu -Plumbin -/Nail Plates 1%z inch min. Drain Size Washing Machine Drain 2 inch min.- ead or Air Supply'Pest Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction 'Wiier.,Supply Piping Cooper Comiriercial Cooper, CPVC,Pex One and Two-Famil Insulation/Residential Check/ Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air S!!pply for Furnace Duct work sealed properly/No duct tape COM NTS: G. '2) U )p �A L:\SueFlemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insulation Inspection Report Office No. (51 8) 761-8256 Date Inspection request received: , Queensbury Building& Code Enforcement Arrive: am/wn De - am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: fi c (pS PERMIT #: LOCATION: L INSPECT ON: TYPE OF STRUCTURE: Y let N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size W shin Machine Drain 2 inch min. ead or Air Supply Test v Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper,CPVC,Pex One and Two-Tamil Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: LASueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: j am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: +`(T.S/ i/ PERMIT#: LOCATION: /YJ� U INSPECT ON: TYPE OF STRUCTURE: Y N` N/A Framing COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping' Penetration sealed ti 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8,inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 i Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: Vw am/pm Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: /Z NAME: PERMIT #: t� LOCATION: ) INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2, R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanont every 100 feet/change of direction' Water Supply Piping Cooper Commercial o er, CPVC,Pex One and Two-Family ,� sulation/Residential Check/ Commercial Check CC Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Fuirnace Duct work sealed properly/,No duct tape COMMENTS: LASueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing insulation Report.doc November 17,2003 Framing / Firestoppirig Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: arn/p D part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: 4 NAME: PERMIT#: O I LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS Framing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping,for Notches Top Plate 1 2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Le\SueHemingway\Building.Codes.In spec tion.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: n Queensbury Building& Code Enforcement Arrive: _arn/ De am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initial NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS � �)-tea Jack Studs/Headers Bracing/Bridging i✓�j r,Q�LC, iCJ/Z� �O� Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire si eparation 1, 2, 3 hour F re wall 2, 3, 4 hour a irtVstopping DW� Penetration sealed f 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingw•ay\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: _ _ Queensbury Building&Code Enforcement Arrive: an-/pm Depart: -am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: _ �ce,1 to PERMIT#: LOCATION: _ , , I `L _ INSPECT ON: I o . TYPE OF STRUCTURE: Comments N NIA Piers Monolithic Slab Reinforcement in Place The contractor is respon-ble �r providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfrll Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codcs.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: a m 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: CI NAME: kle, �� s �' PERMIT#: LOCATION: / INSPECT ON: 0 TYPE OF STRUCTURE: r Comments Y N /A ootl /� Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/ Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\nuii ding.Codes.InspectionTORMSToundation Inspection Report.doc Januaiy 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received. Queensbury Building& Code Enforcement Arrive: am/p epart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: f_ NAME: S PERMIT#: (� .. (� LOCATION: M T , / ; Lt.,] �+.}-r`r� INSPECT ON: TYPE OF STRUCTURE: Y Framing N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 . Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: , Queensbury Building& Code Enforcement Arrive: am/p epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: f/oli PERMIT #: (P LOCATION: IAA r. L--,I, INSPECT ON: II !� a, TYPE OF STRUCTURE: Y N N/A ke_G 6 GIC. PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/chan a of direction Water Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doe November 17,2003 L( Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/pin ppe�part: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials. `� NAME: PERMIT #: LOCATION: �� d'1\ � � ;,,�,�' ���� INSPECT ON: -� TYPE OF STRUCTURE: Y N NIA PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest , l connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping I L � Cooper Commercial g o er, CPVC, Pex One and Two-Family sulation/Residential Check/ Commercial Check -Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: �- �U rF �'V(.vcEloc�S LASueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: i Queensbury Building& Code Enforcement Arrive: am/pr>I Depart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: 3 NAME: klo-.5 1A)- /--/l PERMIT #: ® �7 LOCATION: )/6 mr, ICE✓ •U . INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1, R-2, R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min. Drain Size Washing Machine Drain 2 inch min. Mead or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Family Insulation/Residential Check/ Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air S!ipply for Furnace Duct work sealed properly/No duct tape COMMENTS: LASueHemingwa}\Building.Codes.Inspection.FORM STough Plumbing Insulation Report.doc November l7,2003 14 31 Framing / Firestopping Inspec n Report �� Office No. (518) 761-8256 Date Inspection request received: 11 et Queensbury Building&Code Enforcement Arrive: _a pm' fDepart:: m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials<:N . E t . _ NAME: ;S 1 LS PERMIT#: 17 LOCATION: INSPECT ON: 1/ TYPE OF STRUCTURE: 6 -_ � Framing / COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall/ Fire separation 1, 2, 3 hour / i wall 2, 3, 4 hour / � ".Firestopping,.-.- .-.. _ . netrati n led inch insulation in caXtymin. Garage Fire Separation House side %inch o 5/8 inch Type X Garage side 5/8 i jc`h Type X Ceiling/wail1 Windows Habitable Space/Bedrooms 24 in. (H).% 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemin-,way\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: t),v /,2ev f Queensbury Building&Code Enforcement Arrive: am/lq?7� am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: �51�s�\ PERMIT #: 7 LOCATION: �1 ' INSPECT ON: NOV. TYPE OF STRUCTURE: Y N Nhir PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 411/0 �c� b 1 % inch min. Drain Size Washin 2 inch min. G (.5 G— He or Air Supply Test Drain and Vents �� 5 PSI or 10 feet ove highest UlJ on for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Fanul Insulation/Residential Check/ Commercial C eck Proper Vent,Attic Vent Duct/Hot Water Piping Insulation Z If re uired unheated s aces Combustion Air Supply for Furnace Duct work sealed properl /No ductlea e i COMMENTS: f �l LASueHemingway\Building.Codes.Inspection.FORM S\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insulation Inspection Report Office No. (51 8) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: m Pepart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials NAME: PERMIT #: C_�L- 6/) LOCATION: � ` ` I L—QmINSPECT ON: / TYPE OF STRUCTURE: Y N N/A PVC: -1,R-2,R-3,R4 Drain/Vents Ca Iron, Copper Drain/Vent/Comm. Ambing Vent/Vents in Place ou h Plumbing/Nail Plates 1 1/z inch min..Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper,CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: LASueHemingway\Building.Codes.Inspection.FORM S\Rough Plumbing Insulation Report.doc November 17,2003 Framing / FirestoPP g in Inspection Report P P Office No. (518) 761-8256 Date Inspection request received: ,A a _,. Queensbury Building& Code Enforcement Arrive: _ai e art: am/p ,- 742 Bay Road, Queensbury, NY 12804 Inspector's Initials NAME: C I PERMIT#: LOCATION: 'I n Mo '\'a PA ) INSPECT ON: -U!J TYPE OF STRUCTURE: 1 Y N ' N/A COMMENTS TS �r�a�rn�ing:- I Jack Studs/Headers C_ Bracing/Bridging 1— Z� Joist hangers LA, ` Jack Posts/Main Beams rU Le-t1 Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. ����`�/ �` � ,Q_•CCC� Stairwells 36 in. or more 1 Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour >Fi--resto in j Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 / A, Framing / Firestopping nspectio Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: _ arri/pm Depart: 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: Cl ;L� I XJsi�S k� PERMIT#: LOCATION: INSPECT ON: O a TYPE OF STRUCTURE: i Y N N/A COMMENTS (f Framin Jack Studs/Headers Bracing/Bridging s�J Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. _ Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Z�_q Ice and snow shield 24 inches from wall2 5b Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 I r vv -A CWO _ f S' 5"1 fib 21 I / I a X/�� 76p N - -2 7 q0o � �� JJ is � f Permit Number REScheck Compliance Certificate . Checked By/Date New York State Energy Conservation Construction Code- REScheckSoftware Version 3.5 Release la Data filename: C:\Program Files\Check\REScheck\07604 KOSINSKI-MOUNTAIN VIEW,QUEENSBURY.rck TITLE:PLAN NO.07604 COUNTY:Warren STATE:New York HDD: 7635 RECEIVED CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE:08/11/04 AUG 1 20�� DATE OF PLANS:JULY 30,2004 TOWN OF: QUEENSBURY BUILDING AND CODE PROJECT INFORMATION: KEITH&SHIRLEY KOSINSKI MOUNTAIN VIEW LANE QUEENSBURY,NEW YORK 12804 COMPANY INFORMATION: WILLIAMS&WILLIAMS DESIGNERS 509 GLEN STREET GLENS FALLS,NEW YORK 12801 COMPLIANCE:Passes Maximum UA=251 Your Home UA=222 11.6%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter 'R-Value R-Value U-Factor UA Ceiling 1:Cathedral Ceiling(no attic) 945 38.0 0.0 26 Ceiling 2:Cathedral Ceiling(no attic) 637 38.0 0.0 17 Wall 1:Wood Frame, 16"o.c. 1111 19.0 0.0 59 Window 1:Wood Frame:Double Pane with Low-E 70 0.320 22 Door 1: Solid 60 0.130 8 Wall 1 Wood Frame, 16"o.c. 565 19.0 0.0 21 Window 2:Wood Frame:Double Pane with Low-E 174 0.320 56 Door 2:Glass 40 0.330 13 Furnace:I:Forced Hot Air,85 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When;a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. Build Designe Date s i REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release la DATE: 08/11/04 TITLE:PLAN NO.07604 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Cathedral Ceiling(no attic),R-38.0 cavity insulation Comments: [ ] 2. Ceiling 2:Cathedral Ceiling(no attic),R-38.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 2. Wall 2:Wood Frame, 16" o.c.,R-19.0 cavity insulation Comments: Windows: [ ] 1. Window 1:Wood Frame:Double Pane with Low-E,U-factor: 0.320 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 2. Window 2:Wood Frame:Double Pane with Low-E,U-factor: 0.320 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: Doors: [ ] 1. Door 1: Solid,U-factor: 0.130 Comments: [ ] 2. Door 2:Glass,U-factor:0.330 Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,85 AFUE or higher Make and Model Number Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials. If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior.insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State ,the Residential Code of New York State or the New York City Building Code ,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 J 40-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVACPipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)