Loading...
89-830 4 ' CERTIFICATE OF OCCUPANCY TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK Date January 10 1490 This is to certify that work requested to be done as shown by Permit No. 89-830 has been completed. This structure may be occupied as a n addition and two car garage I ncation Seel ye Road Owner Jim & Mary Ellen Merrigan By Order Town Board TOWN OF QUEENSBURY aege://: • Director of Bldg. & Code Enforcement BUILDING PERMIT TOWN OF QUEENSBURY No. 89-830 , -o WARREN COUNTY;NEW YORK q PERMISSION is hereby granted to JIM & MARY ELLEN MERRIGAN OWNER of property located at Seelye Road Street,Road or Ave. w w in the Town of Queensbury,To Construct or place a n addition & a two ra r garage u, at the above location in accordance to application together with plot plans and other information hereto filed and approved and in compliance with the Town of Queensbury Building and Zoning Ordinance. 1. OWNER'S Address is Box 265 Cleverdale, New York 12820 2. CONTRACTOR or BUILDER'S Name 1-4 EXTEND 5/8" TYPE X SHEETROCK Wayne F. Vie1e • ON SIDE WALLS - 2' FROM DO-AWL CONSTRUCTION COMMON WALL - MINIMUM. 3. CONTRACTOR or BUILDER'S Address -< m r r m 4. ARCHITECT'S Name 1-1 . q - A 5. ARCHITECT'S Address • 6. TYPE of Construction—(Please indicate by X) m r XX Wood Frame ( 1 Masonry ( )Steel ( ) m 7. PLANS and Specifications No. 19' x 19' addition to dwelling and a two car garage(attached) as per application, specifications and plot plan. 8. Proposed Use � o Addition & Two car attached garage. $ 67.00 PERMIT FEE PAID —THIS PERMIT EXPIRES May 1, 19 90 (If a longer period is required an application for an extension must be made to the Building and Zoning inspector of the - town of Queensbury before the expiration date.) - h A Dated at the Town of Queensbury this 27th Day of October • 19 X89.. 6-3 t SIGNED BY for the Town of Queensbury - Building and Zoning spector - m TOWN OF QUEENSBURY REVIEWED BY gAil( �/ 1 FEE PAID $_ PERMIT NO. " � � TOWN OF RECEIVED SBURY BUILDING PERMIT APPLICATION OCT 2 31989 BLDG. & CODE DEPT. A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. NO INSPECTIONS WILL BE MADE UNTIL APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. All applicants spaces on this application MUST be completed and the signature of the applicant MUST appear on the a reverse side of this application. • • • • * • • • • • • • • • • • • • • • • • • • * • • • • • • * • • • a • • • • • The owner of this property is:_JTim ,9,vo NIARY-E,ZcN N P.O. Address ,24, Ck.vei2 niL - /)S?20 abLee-igS& A2 Tel. 4;4-4-96'7.2 Property Location £/ID o/' .See/ve Aot, ON A?,QA7L Lie AaaseTax Map No. / /L/ ,37,,3 Has there been any split of this property since October 1, 1988? / ,/ • If yes Planning Board Review is necessary. yes no SUBDIVISION NAME, IF APPLICABLE J)Q , MId /h k LOT NO. 72-)3Y.-)4-/aO THE PERSON RESPONSIBLE FOR SUPERVISION OF WORK AS REGARDS TO BUILDING CODES IS: WAYNE F. VIE/.1- ,l ,CA ,DOAWL C'oNst/egC`7`ioN • NATURE OF PROPOSED WORK: * ESTIMATED MARKET VALUE OF • Construction of a new building „ CONSTRUCTION: $ /53.000, `/ Addition to a building • COMPLETE INFORMATION REQUIRED BELOW: * -"Size of property /0/ ft xa " °ft. Alteration to a building * -"Existing Buildings(3) Size 32/ ft. x 56 ft. (no change to exterior dimensions) • ✓Proposed building - distance from property line: Other work (Describe) " Front yard /.Gd ft. Rear yard ZOO ft. ' Side yards (3o ft. and - 330 i ii( ft. • GROSS AREA OF PROPOSED STRUCTURE If on corner, setback from side street ft. 1st Floor . 36/ sq. ft.-36-- -?e6144,94 OCCUPANCY INFORMATION 2nd Floor 36/ sq. ftj_oMZ, • Primary Building - Other Floors 722 sq. .�/ . One Family Dwelling (not cellar or basement) • Two Family Dwelling TOTAL FLOOR AREA sq. ft. • Multiple Dwelling/Number of units Size of new structure /9 ft x /�ft. • Business tslab crawl/ • Industrial Foundation-pier � partial/full (circle one) • /Other F;Rsf F/e0 - G'/0196E • No. of stories (habitable space) n%VL • S-ccowo F/a612 Room Height (grade to ridge) :6 ft. • If addition, what will use be? / F/®oR ( I M&I, If residential, no. of families. C3niE • a"`� FIoaR. fi9m1%0 Room No. of rooms(excluding baths) ON E • Accessory Building No. of bedrooms NONE ' __Detached Garage ONE/TWO Car No. of bathrooms NO.,VF ' . - • Primary heating system F/_/_d • .Attached Garage ONE/'I'WO Cu' Type of fuel V • Private storage building No. of fireplaces to be installed N ' _Other Willa wood stove be installed NO • • Central Air conditioning AI OVER • friy- ii° BUILDING PERMIT APPLICATION CONTINUED - Bt•ILDIAIG'4:4•F5CIFIC ATIONS: Type of construction, wood frame, fire safe. etc. Wool() MI9/27E ,Will•:anyjsecond7h4n0 or upgraded lumber be used? If so, for what? No Foundation wall material IYJ//m/AA 1.3//lC_'/ Thickness " Depth of foundation below grade (to bottom of footing) /eta 3' NocX .�eda e Will there be a cellar? A/G Heated or unheated? Floor sq. footage sq ft. Will there be a basement? NO Will any portion be used as living space? A/n (If so, what portion? sq ft. Type of use? Type of roof -(slopedYflat/shed/other Material of roof Asp,y, /¢ Size, wood studs 2 "x L) "spacing )6 " o.c. length _Q ft: Joists (floor beams) 1st floor "x " spacing "o.c. span ft. Joist (floor beams) 2nd floor ' 2 "x )0 " spacing /2. "o.c. span /Prilt. Overlays (ceiling beams) "x " spacing " o.c. span ft. Roof rafters 2 "x " spacing ,/-1 o.c. span 9 ft. Roof trusses (pre-engineered) spacing " o.c. span ft. Exterior wall finish , RoN&2.C'k cthbys of what material? LUooD t l0�Ne ) Interior wa11 finish 5 ee7'/Rock If a garage is to be attached, describe materials to be used for FIRE SEPARATION: //fiRE /,17e%1 SAefigacA TYPE Is there to be an opening between garage and dwelling? >'c c If so will a Fire-rated door, enclosure, self-closing device be provided? " YES - Will a flue-lined chimney be installed? ND Height above roof ft. Depth of chimney foundation below grade ft. Depth of fireplace hearth ft. in, Water supply - Municipal or private well ' SEPTIC SYSTEM Distance from ANY private well (including adjoining properties ft. (A separate application is necessary for any repair or new installation of septic system) 00-kvvi. comsiLAMC /on NAME OF BUILDER 1n/AyNE VTEL.E ' ADDRESS A0, G3cx 730 Gf/qgTEL. NO.. 79g- 314'O NAME OF PLUMBER ADDRESS Fi". TEL. NO. De-AWL c NsiqUefloN . NAME OF MASON WAYnNE VI EL E ADDRESS po, Ro u 93o G.F. ivy,, TEL. NO. 778-3/L/O. no-A}WI CONS*RU- AI NAME OF ELECTRICIAN WAYAIE V EZE ADDRESS pa 13ou 536 GF, , N,Y, TEL. NO. 79?-3/ WO DECLARATION To the best of my knowledge and belief th0_7' ;tements contained in this application, together with the :tans and specifications submitted, are a true and complete statement of all proposed work to be done on :he described premises and that all provisions of the BUILDING CODE, THE ZONING ORDINANCE, and ill other laws pertaining to the proposed work shall be complied with, whether specified or not, and that uch work is authorized by the owner. , Signature er, owner's agent, are�ect, contractor iPECIAL CONDITIONS OF THE PERMIT: ,- ���� - . -J/4:- -7yr r:c;eke g/ Anti Qi- At/A O't,g 6-1 fl (11/-it'r ,e''..ed"-e1 bit BYs.. e- 1 VMMLV Ur yUL WARREN COUNTY ,, NEW PORK Application -for : BUILDING PERMIT IN COMPLIANCE WITH THE NEW --PORK STATE ENERGY CONSERVATION CODE - - A permit must be obtained before beginning work . ANSWER ALL -of the following: 1 . Gross floor area 26/ 2 : - Type of heat /1:c7K'►C L3ASEUO/'7RD _ . . 3 .. Is the building mechanically cooled? No - - - - 4 . .' Percentage of area of windows and doors 70,g eliCmsh- 41 o ,xND,104/t A. Over 16% Only 1.. Uo value of- gross area of walls , roof/ceiling and floors exposed to ambient conditions . 2 . . Floor - over heat=:• spaces YES CE)- - - a. Are foundat on walls insulated? YES NO - 1. If YES , what is the R value? 3 . Slab on grade YES NO - a.- If YES , wh .t is the Rr value of- insulation around perimeter of floor? - • • 4 . Is basement heated? YES NO -- - a. R value of insulation 5. Type of insulation - - - B. - Under 1-6% Only -- 1. R value of roof and floors exposed to ambient conditions_ f/oon , /d-38 Rao/' 2 . R value of exterior walls iQ- ,S 7 nd .F/oolZ 3 . R value of glazed area �9,0I4-RSo/,/ low 5 - - 4 . R -value of -doors PeAci4'Mee 5. R value of floors over unheated spaces R-25 - - 6. - R value of slab edge insulation = unheated. slab - 7. R value of slab insulation - heated slab - - - 8. R value of heated basement/cellar walls (above grade) 9. R value ofheated basement/cellar .walls (below grade) - 10. Type of insulation ' C. Controls - 1 . Thermostat maximum heat setting - G8 °F D. Duct Systems - - - 1. Is duct system installed in unheated spaces? YES 61-6) a. If YES, R' value of duct installation - - - b. R value of duct in other areas -- E. Piping Insulation 1. Size. of hot water or cooling carrying agent pipe 2 . R value of pipe insulation F. Service Water Heating 1. Performance . efficiency - - 2. Temperature control setting maximum • G. For Swimming Pool. Only 1. Maximum heating • Telephone No. 77 -3/y0 cAR/Aive 79y-ao36 pplicant ' s signature) - -- TOWN OF QUEENSBURY ' BUILDING AND CODES DEPARTMENT BAY & HAVILAND ROADS ,/,��i/J QUEENSBURY, NEW YORK 12804• 7/ ."� TELEPHONE (518) 792-5832 BUILDING INSPECTOR'S , PORT REQUEST FO INSPEC ION RECEIVE, NAME - / � .c G%(r ,,v LOCATION P �( ( ,_ c /,(���7 a DATE _I P IT (# , ,p(j U APPROVED YES NO FOOTING/PIERS MONOLITHIC POUR FORMS FOUNDATION/DAMP-PROOFING BACKFILL APPROVAL ROUGH PLUMBING FRAMING° ELECTRICAL ROUGH-IN INSULATION: FOUNDATION FLOORS WALLS CEILING VFINAL INSPECTION: ' CHIMNEY HEIGHT . • ROOFING ✓. SIDING ✓ EXTERNAL PORCHES/STEPS _ STAIRS-CLEARANCE &RAILS PLUMBING FIXTURES/rELIEF VA VE INTERIOR TRIM/PRI ACY DOORS FINISHED FLOORS GARAGE FIREPROOF G DOOR CLOSER(S) SMOKE DETECTORS FINAL ELECTRICAL I SPECTION y FINAL APPROVAL OF ONSTRUCTION ' A SIGNED CERTIFICATE OF OCCUPANT MUST BE OBTAINED FROM THE BUILDING DEPAR MENT BEFORE THESE PREMISES ARE\OCCUPIED! REMARKS: i IN PECTOR TOWN OF QUEENSBURY BUILDING AND CODES DEPARTMENT BAY & HAVILAND ROADS QUEENSBURY, NEW YORK 12804- TELEPHONE (518) 792-5832 BUILDING INSPECTOR'S REPORT REQUEST FOR INSPECTION RECEIVED NAME A U"e_i 6 A,U. LOCATION I �6 L 6"- 0 DATE /J/3!� V? PERMIT #f 9'f'90 ADOtTCdo 4- Z CIN-a__6N-PA-G APPROVED YES NO 'lOOTING/PIERS MONOLITHIC POUR FORMS / FOUNDATION/DAMP—PROOFING BACKFILL APPROVAL ROUGH PLUMBINQ / FRAMING ( ELECTRICAL ROUGH—IN 7 INSULATION: FOUNDATION 1 FLOORS 'e^ ' WALLS jL—/CI -1—`/�/ I-I I,.'''(c c/ CEILING 12-—"3 r FINAL INSPECTION: ‘ r' CHIMNEY HEIGHT " _ ROOFING 4, -• _ _ _ SIDING ,/ EXTERNAL PORCHES/STEPS i STAIRS—CLEARANCE & RAILS PLUMBING FIXTURES/RELIEF VALVE INTERIOR TRIM/PRIVACY\DOORS FINISHED FLOORS _ GARAGE FIREPROOFING \ DOOR CLOSERS) t - SMOKE DETECTORS t, FINAL ELECTRICAL INSPECTION'., ' FINAL APPROVAL OF CONSTRUCTION l A SIGNED CERTIFICATE OF OCCUPANCY MUST BE OBTAINED FROM THE BUILDING DEPARTMENT BEFORE THESE PRIEMISES ARE OCCUPIED!' { x REMARKS: NSPECTOR ' ) TOWN OF QUEENSBURY BUILDING AND CODES DEPARTMENT BAY & HAVILAND ROADS QUEENSBURY, NEW YORK 12801— TELEPHONE (518) 792-5832 BUILDING INSPECTOR'S REPORT REQUEST FO INSPECTION RECEIVED NAME (/'77 7ii LOCATION 'L &2', l/ DATE 7/— V PERMIT # ce?'9.—fI 4?(J APPROVED YES NO MONOLITHIC POUR FORMS FOUNDATION/DAMP—PROOFING BACKFILL APPROVAL c/pIGH PLUMBING MING ' I Co/ ELECTRICAL ROUGH—IN INSULATION: `' FOUNDATION\ FLOORS I' WALLS CEILING :, FINAL INSPECTION: ' CHIMNEY HEIGHT ROOFING \ / SIDING '\ ,--- EXTERNAL PORCHES/STEPS STAIRS—CLEARANCE &�; RAILS PLUMBING FIXTURES/RELIEF VALVE INTERIOR TRIM/PRIVACY DOORS FINISHED FLOORS_ GARAGE FIREPROO ING DOOR CLOSER(S) SMOKE DETECTOR'S 1 FINAL ELECTRICAL INSPECTION FINAL APPROVAL 10F CONSTRUCTION\; A SIGNED CERTIFICATE OF OCCUPANCY MUST BE OBTAINED FROM THE BUILDING DEPARTMENT BEFORE THESE PREMISES ARE OCCUPIED! REMARKS: I /I _ _ Jf INSPE TOR TOWN OF QUEENSBURY BUILDING AND CODES DEPARTMENT 711 BAY & HAVILAND ROADS QUEENSBURY, NEW YORK 12804- TELEPHONE (518) 792-5832 BUILDING INSPECTOR'S REPORT REQUEST FOR INSPECTION RECEIVED NAME LOCATION ./f7W DATE /fl 430 cc?-7 PERMIT # �� U APPROVED YES NO 6ROOTING/PIERS (� MONOLITHIC POUR FORMS FOUNDATION/DAMP—PROOFING BACKFILL APPROVAL ROUGH PLUMBING FRAMING ..' ELECTRICAL ROUGH—IN INSULATION: FOUNDATION 1'U FLOORS WALLS r , CEILING /` ' FINAL INSPECTION: CHIMNEY HEIGHT ROOFING SIDING EXTERNAL PORCHES/STEPS'„ STAIRS—CLEARANCE & RAILS, PLUMBING FIXTURES/RELIEFVALVE INTERIOR TRIM/PRIVACY DOORS,, FINISHED FLOORS GARAGE FIREPROOFING DOOR CLOSER(S) s SMOKE DETECTORS z " FINAL ELECTRICAL INSPECTION \L FINAL APPROVAL OFjCONSTRUCTION A SIGNED CERTIFICATE OF OCCUPANCY MUST BE OBTAINED FROM THE BUILDING DEPARTMENT BEFORE THESE PREMISES ARE OCCUPIED! REMARKS: bObf:q•r; 1 9 A ft y, y /6, 31- . 0:66 ' INSPECTOR )01' Jill i, 4 1 I 1 � I i e 3 i T , � 1 t20G i >aEURY 4�E{Mt � ----�' � VE'R1�3Ul�1 T�3U1�1C U,L1R DT t M 30 0 � 4 VR P05ED EX15TIMU h N AbINTI N UbUSE i 1 I , 0 LL i I o 1 � _ TOWN OF QUEENSBURY Zoning Administrate -44 > SEE L`I E KC)M DD AWL ("DUST SCALE{w' 20' � REVISIONS By DATE L&M,5 OF' DE_SOMCo LEE DATE 74!!^CT 8'i S/ �. 0*y CKD. AIViD... TIn'PE Z �f V N L)E �Ia M S No.4 Q F 4 Z