Loading...
2004-673 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20040673 Date Issued: Friday,August 19, 2005 This is to certify`that work requested to be..done as shown by Permit Number P20040673 has been completed. Tax Map Number: 523400-266-001-0002-032-000-0000 Location: 52 BOULDERWOOD Dr Owner: RONALD & DORIS BLACHUT Applicant: RONALD &DORIS BLACHUT This structure may be occupied as a: Garage - 3 Cars Attached By Order of Town Board Residential Addition TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan,. Variance, or other issues and conditions as'a result of approvals by the Director of Building&.Code Enfox men Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040673 Application Number: A20040673 Tax Map No: 523400-266-001-0002-032-000-0000 Permission is hereby granted to: RONALD &DORIS BLACHUT For property located at: 52 BOULDERWOOD Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: RONALD &DORIS BLACHUT Garage-3 Cars Attached 52 BOIJLDERWOOD Dr Residential Addition QUEENSBURY, NY 12804-0000 $100, 00 Total Value $100,000. 0 00 Contractor or Builder's Name /Address Electrical Inspection Agency PRECISION CONSTRUCTION 8 CONNER DRIVE SOUTH GLENS FALLS, NY Plans&Specifications 2004-673 1274 SQ FT RESIDENTIAL ADDITION W/817 SQ.FT 3-CAR ATTACHED GARAGE $234.58 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, September 07, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To bf e 4s S ptember 07, 2004 en sb 9 SIGNED BY / 4 r for the Town of Queensbury. Director of Building&Code Enforcement Building Permit A.ppi cation Town of Queensbuty-Dept of Community Development,742 Bay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Perlait File No. 7 No inspection will be made until applicant has received a Fee Paid $ 4.S� valid wilding permit. All applicants' spaces on this Roo.Fee Paid $ application must be completed and must appear on the Reviewed By: applidation form. . l�C/fc Applicant: , �a N� f�. 7- Owner: - i?o.vA Jd Address: S 2, Soul A 0O'b .75 R— Address: 4'Z 8a veers un 0vEEi✓s 8IV2 Phone#(519 -. 52 7 Phone#(mod)2yaT Yam/ Property Location: Lot Number: / House Number So Subdivision Name: Q(ay,t &r es Tax Map Number: _. 2 --32 o New Building: residence /commercial 'Estimated Market Value of Construction. Addition: residence ommereial If an Addition,what will use of new addition be? C Alteration: residence/ commercial t; n r� S!a e e. a'n ct O No ebange to wdedor size: residence/com'1 C1 Other wbrk(deseribe ) Check Occupancylnformation 1' Floor Z° Floor Other floor Total Below sq.it. sq.ft. sq.ft. Square Feet Sin a finii1y dwelling 12 14 m Two family dwelling a Townhouse a Multifamily dwelling #of units m Office m Mercantile m Maaufaatt� . m 1 car detached pmge ' - n 2 cax detached smgo L m 3 car detached garage OQE m 1 oar attached garage c- 2 car attached 9=90 )K 3 car attached garage B t 7 a Storage building- cozmaercial o Storage building- residential o Other What is the proposed height of the structare??-_feet inches Will say second-hand or ungraded lumber be used? If so,for what? Type of Heating System: electric/ oil / gas/wood /forced hot air/ baseboard/.other: Number of 'irenlaces to be installed Number of WoodstUet to be installed -� List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder A4c;5 ron .,i We r-s ISf,,eve-Dart holt- - 7yy= 7fo OT _ - Plumber Mason Electrician Declaration; please sign below after you have cweWy read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that Vwe shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an As Ruut Survev by a licensed surveyor;drawn to scale,showing actual location of all now construction. Signature: G�S t�. -r owner,owner's agent,architect,contractor Check Residential Plan Review: One & Two Family Dwellings YININIA , (2)Full sets of plans , Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: indow Schedule With Glass Size Door Schedule/Main Entrance 36"Door mergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofmg/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6"Drop in 10' Exterior Grade Taming Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where Ll Required If Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls JAIlatforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise A f Winder Run and Rise f, Spiral Not Allowed From 2n Story Smoke Detectors Battery Backup and Proper Location athroom Fixtures Proper Clearance ,Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>.30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped tic Access ` Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access LCarbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: arr_ epart: %r m/pm Date Inspection request received: Inspector's Initials: NAME: c—_&O GAD l PERMIT LOCATION: 5-0 U i� �^ DATE: TYPE OF STRUCTURE: _ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Co m lete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in, or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18" above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Ba " oom/Kitchen watertight fe lzin /Window in stairwells safety glazing nterior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector _ Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stoppillg finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/a hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection Office No.'(518)761-8256 Arrive: art>% Depart: 2 U"airvpm Date Inspection reque received: Inspector's Initials: � NAME: C� �, PERMIT#: LOCATION: Q DATE: TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more ci)stairs,decks,patios Guard at stairwell at 34 in. or morer Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: / Every level: / Every Bedroom: l// Outside every bedroom area: Inter Connected: ! Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency a ress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/1/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl S aces 18"x 24"-acc ss, 1 s . ft.-150 s . ft.vents Building No./Add s vis' .le from r9,4d, Final Electrical Site Plan /Varianc re fired Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Buildinp,&CodesUnspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No........................................Cert. N® 89577 Cut-in Card No.......................... ....ti] Owner.............................. .�...f-%... �...- .................................................................................. Location.s��r.�`�.. ...6r.?�GGA e-D ��' ....... .....:�.... .................................... ... s.. .. .................... ..... ..................... ......... ........ . . Installation Consisting of 7;�..51av� �:. ..... ............ 'W........................................... �2rl d:{ ....... Llt .� I �.....Lic.No................................................... Installed By.... .................... .................................. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of makin pections at any time, and if its rules are violated,the Company shall have the right t reyMe this ertificate. ` ✓Date... ..r &,5........................................... INSPECTOR... .......................................................................................... U-h-NKPA iAFl Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: 5 Queensbury Building&Code Enforcement Arrive: _am/ e am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: LA-;AJC J-1 PERMIT#: �07 LOCATION: INSPECT ON: z Off' TYPE OF STRUCTURE: Framing Y N IN/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches frorn wall Fi separation 1, 2, 3 hour Aire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report �e Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: _am/p epart: m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: (�� PERMIT#: `\J � G 73 LOCATION: Sa (' , INSPECT ON: - TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wal , 3, 4 hour //stoppingP60 6 Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 _%1 V Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/ epart: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT #: LOCATION: ()u ery INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping oper Commercial 0o er, CPVC,Pex One and Two-Family sulation/Residential Check/Commercial Chec Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 6 -- l - U Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: _ Queensbury Building& Code Enforcement Arrive: am/p D art: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: 9 PERMIT #. -3 LOCATION: INSPECT ON: - S TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch nun. Head or Air Supply Test Drain and Vents 5 PSI;or 10 feet;above highest connection for 15 minutes Cleanout every 100 feet/change of direction nn Water pply Piping �S Iti�a oper Commercial ///_ Ca oo er,CPVC,Pex One and Two-Famil l(.( t z 1 (isulati6n/Residential Check/Commercial Check, Proper Vent,Attic Vent Duct/Hot Water Piping Insulation (t/eNDS If required unheated spaces Combustion Air Supply for Furnace T- Duct work.sealed; ro erl /No duct toe COMMENTS: P-1.4-T'C- 1.) L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: 3 Queensbury Building& Code Enforcement Arrive: arn/pDepart: 'am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: L���t C�Lc.7L PERMIT#: LOCATION: h b !`r„> INSPECT ON: �,/�. z,,,�� osoos TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour estoppin c�r�� �' lit/ Penetration seal d 16 inch insulation in cavity min. Garage Fire Separation ('j� IAJS()4-House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doe January 28,2003 /0 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/ m Depart: 0 pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:-�� NAME: `I\ a, A-vu PERMIT #: Pq- (D-7 3 LOCATION: aINSPECT ON: TYPE OF STRU T Y N N/A PVC: R-1,R-2, R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. 1P1 in Vent/Vents in Place `R611t'`h,Plumbing/Nail Plates 1 % inch min. Drain Size Washing Machine Drain 2 inch min. Head,or Air Supply Test `''Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: LASueHemingway\Building.Codes.Inspection.FORM S\Rough Plumbing Insulation Report.doc November 17,2003 Framing / Firestopping Inspection ReportWA Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: a-n/ D art: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initial NAME: PERMIT#: 1 L 7 LOCATION: - INSPECT ON: TYPE OF STRUCTURE: Y N YVA F `..ME-,, v COMMENTS Jack Studs/Headers Gi 4,Q/ Bracing/Bridging I'' Joist hangers l�� Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft, floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour y Eiries Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 V Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: lldo Queensbury Building&Code Enforcement Arrive: am/ Depart: a pm 742 Bay Rd., Queensbuiy,NY 12804 Inspector's Initials: NAME: T_ C PERMIT#: 67 0L. LOCATION: (,voab INSPECT ON: IoGF TYPE OF STRUCTURE: Comments Y N N/A tings Piers nolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 1.2 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.Inspection.FORMSToundation Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: f J am/p Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: �CG�1 cJ PERMIT#: )3 LOCATION: Z (.. t r�+� INSPECT ON: Z� TYPE OF STRUCTURE: Y N lvia Framing COMMENTS Jack Studs/Headers Bracing%Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield.24 inches from wall- Fire separation 1, 2, 3 hour . Fire wall 2, 3'5 4 hour Firestopping Penetration sealed -16 inch insulation in cavity min. Garage Fire Separation House side t/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report —z— Office No. (518) 761-8256 Date Inspection req st re el la ' Queensbury Building&Code Enforcement Arrive: a pm D aJ�' ��r a 742 Bay Road, Queensbury, NY 12804 Inspector's Initi s: A �` NAME: , PERMIT#: & 7 LOCATION: INSPECT ON: c TYPE OF STRUCTURE: `S' Y N N/A COMMENTS Framing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center ce an sow shield 24 inches rom Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side t/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemin-,Way\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/p Depart./n-Vpm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: // vv NAME: V-1 Ci k + PERMIT#: __ c LOCATION: e-woo N WSPECT ON: "Z U TYPE OF STRUCTURE: Comments �- N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing mil poly for wet areas under slab _ ackfill Approval bins TSilcier S+Tali -y PV /Cast/Copper G Eoundati� Tnsulatio ., Inter or Exterior Rough Grade 6 inch drop within 10 ft. I.:\SueHemingway\Buil ding.Codes,Inspec tionTORNISTound'ation Inspection Report.doc January 28,2003 Town of Queensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(518) 745-4437 Fire arshal's Inspect! n Report Request SCHEDULE Received: ennit# INSPECTION ON: Name: AM PM ANYTIME Location: APPROVED N/A. YES NO COMMENTS EXIT ACCESS EXIT ENCLOSURE EXIT DISCHARGE MAIN AISLE WIDTH \\ SECONDARY AISLE WIDTH EXIT SIGN-NORMAL EXIT SIGN-BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHER HUNG FIRE EXTINGUISHER INSPECTION FIRE EXTINGUISHER HYDRO FIRE ALARM SYSTEM FIRE ALARM -FAN SHUTDOWN FIRE SPRINKLER SYSTEM FIRE SUPPRESSION-KITCHEN - FIRE SUPPRESSION-GAS ISLAND HOOD INSTALLATION INTERIOR FINISHES STORAGE COMPRESSED GAS L. CLEARANCE TO SPRINKLERS ' CLEARANCE TO ELECTRICAL ELECTRIC WIRING ENCLOSED COMBUSTIBLE WASTE VEHICLE IMPACT PROTECTION FIRE LANE F.D.SIGNAGE-UTILITY ROOMS NO SMOKING SIGNS MAXIMUM OCCUPANCY SIGN EMERGENCY EVAC PLAN t ! 1 OK THIS DATE ,� J; OK FOR CO NOT OK ,1 INSPECTED BY COM DEV/CHRIS JIWORD/LETTERS2001/FIRE MARSHALI NS PECTIONRE PORT11022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY NV� Septic Inspection Report Office No. (518)761-8256 Date Inspection reque t received: Queensbury Building&Code Enforcement Arrive: am/ Depart: CJ �Lim/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT NO.: LOCATION: ;3 a•t,, s n,�p INSPECT ON: U RECHECK: Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: i in S', T e Buildingto tank L Y�/1��� �I� �j� �� Tank to Distribution Box I Distribution Box to Field/Pit Opening Sealed: Y/N/Partial Location/Separations - CA) LY Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use It- pproved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved L:\SueHemingway\Building.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 Septic Inspection Report Office No. (518)761-8256 Date Inspection request received. l } Queensbury Building&Code Enforcement Arrive: am/ m Depart : �a pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: 01r1c�-� 2.i.� PERMIT NO.: &73 LOCATION: INSPECT ON: RECHECK Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping SizPj( Type ) , Building to tank Tank to Distribution Box Distribution.Box to Field/Pit Opening Sealed: Y/N/Partial Location/Separations Foundation to tank ft. Foundation to absorption ft. Z6 e-)r Separation of Pits ft. ` Conforms as per Plot Plan Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: roved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved r Foundation Inspection Report Office No. (51 8) 761-8256 Date Inspection request received: u Queensbury Building &Code Enforcement Arrive: am/p art: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: .1 _ �� PERMIT#: _ �' 7-3 LOCATION: �c //�SPECT ON: 7 TYPE OF STRUCTURE: / 64< A V Comments I -- Y IN N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wall.pour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab _ Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation.Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Buil ding.Codes.InspectionTORNISWoundation Inspection Report.doe January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request recei ed: 1►I a(o b 4 Queensbury Building&Code Enforcement Arrive: am/p Depart:4 am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: 04 - (o—[3 LOCATION: 5a 'Bo u-- cter•uo o©d INSPECT ON: i l)a0 1 Q;q TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour enforcement in Place ouriddtion.-Dampproofing Foundation/Waterproofing Type of Dampproofmg/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 1.2 inch width 6 inches above footing 6 mil poly for wet areas under slab i -Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.Inspection.FORMSToundation Inspection Report.doc January 28,2003 Framing / Firestopping.Ins ection Report Al 4�7�Office No. (518) 761-8256 Date Inspection jaipre ceiv Queensbury Building&Code Enforcement Arrive: De a 1 h�a742 Bay Road, Queensbury, NY 12804 Inspector's Initia � ' NAME: lr PERMIT#: �ld 73 LOCATION: INSPECT ON: TYPE OF STRUCTURE: raming Y N N/A COMMENTS � Jack Studs/Headers Vj Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation i House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHernin-,way\13uilding.Codes.Inspection.FORMS\Frarning Firestopping Inspection Report.doc January 28,2003 Vn- Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ Depart: � am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: , _ y PERMIT#: / LOCATION: V , - INSPECT ON: � C3 TYPE OF STRUCTURE: Comme Is t Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing I 4 ours following the placement o e concrete. aterials for this puMose on site. oundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\.SueHeming,�vay\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pr��j Depart: pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: ao. . } PERMIT#: LOCATION: T " P INSPECT ON: TYPE OF STRUCTURE: C - Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the5oncrete. dials for this purpose on site. undation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Ajo Queensbury Building&Code Enforcement Arrive: anv Depa : a pm 742 Bay Rd., Queensbury,NY 12804 hispector's Initials: NAME: l�� / L'r PERMIT#: �e3 LOCATION: _ -�.17?a _ INSPECT ON: d TYPF.OF STRUCTURE: J ✓_�'�� '� � Comments __ ---R--- __ Y N N/A ootin Piers Monolithic Slab Reinforcement in Place The contractor is responsible fot` providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site._ Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofng/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12inch width 6 inches above footing 6 milpoly for wet areas under slab Backfill Approval Plumbing Under SIab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SucHcmingway\Building.Codes.Inspection.PORMSToundation Inspection Report.doe January 28,2003 Foundation Inspection Report Office No. (518) 761-82.56 Date Inspection request received: Nl�` Queensbury Building&Code Enforcement Arrive: an-/p part: c am/ in 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: _/Gt c-� PERMIT LOCATION: _ _ S J- INSPE . 'ON: U 0100 TYPE. OF STRUCTURE: OA-4j�, dl-' —In co Z2 Comments Footing ^� n Piers ----- 40-r- Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete, Materials for this purpose on site.-- Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproo ng Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab/ PVC/Cast/Coppei f Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHcmingway\BuiI ding.Codes.Inspection.FURMS\Foundation Inspection Report.doe January 28,2003 O � Q 6 Yl LA �v K� `y n 5 RECEIVEDb OD J A N 2 4 2005 Permit Number PC-u TOWN OF QUEENSBURY BUILDING AND CODE REScheck Compliance Certificate Checked By/Date New York State.Energy Conservation Construction Code REScheckSoftware Version 3.5 Release 1 Data filename: C:\Program Files\Check\REScheck\012304A BLACHUT-52 BOULDERWOOD,QUEENSBURY.rck TITLE:PLAN NO.012304 COUNTY:Warren STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE:01/04/05 DATE OF PLANS:JANUARY 4,2005 PROJECT INFORMATION: RON&DORIS BLAC1 UT 52 BOULDERWOOD QUEENSBURY,NEW YORK COMPANY INFORMATION: WILLIAMS&WILLIAMS DESIGNERS 509 GLEN STREET GLENS FALLS,NEW YORK 12801 COMPLIANCE:Passes Maximum UA=477 Your Home UA=387 18.9%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 1716 38.0 0.0 51 Skylight 1:Wood Frame:Double Pane with Low-E 27 0.410 11 Wall 1:Wood Frame, 16"o.c. 1024 19.0 0.0 61 Window 1:Wood Frame:Double Pane with Low-E 175 0.280 49 Door 1:Solid 21 0.130 3 Wall 2:Wood Frame, 16"o.c. 480 19.0 0.0 29 Window 2:Wood Frame:Double Pane with Low-E 30 0.280 8 Door 3:Solid 128 0.130 17 Door 4:Solid 72 0.130 9 Door 5:Solid 21 0.130 3 Wall 3:Wood Frame, 16"o.c. 344 13.0 0.0 28 Window 4:Wood Frame:Double Pane with Low-E 180 0.280 50 Basement Wall 1: Solid Concrete or Masonry 975 11.0 0.0 60 Wall height: 10.0' Depth below grade: 8.0' Insulation depth: 10.0' Window 3:Wood Frame:Double Pane with Low-E 30 0.280 8 Furnace 1:Forced Hot Air,92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Co ervation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,t area ting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are mpli a wi i C de,.-- e )fie esigner Date REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release 1 DATE:01/04/05 TITLE:PLAN NO.012304 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 2. Wall 2:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 3. Wall 3:Wood Frame, 16"o.c.,R-13.0 cavity insulation Comments: Basement Walls: 1. Basement Wall 1:Solid Concrete or Masonry, 10.0'ht/8.0'bg/10.0'insul, R-11.0 cavity insulation Comments: Windows: [ ] 1. Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.280 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 2. Window 2:Wood Frame:Double Pane with Low-E,U-factor: 0.280 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 3. Window 4:Wood Frame:Double Pane with Low-E,U-factor:0.280 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 4. Window 3:Wood Frame:Double Pane with Low-E,U-factor:0.280 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: Skylights: [ ] 1. , Skylight 1:Wood Frame:Double Pane with Low-E,U-factor:0.410 For skylights without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ )No Comments: Doors: [ ] 1. Door 1: Solid,U-factor:0.130 Comments: L ] 1 2. Door 3:Solid,U-factor: 0.130 Comments: L I 3. Door 4: Solid,U-factor:0.130 Comments: [ ] 4. Door 5: Solid,U-factor:0.130 Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,92 AFUE or higher Make and Model Number Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: L I I All joints,seams,and connections must be securely fastened with welds, gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] I Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State ,the Residential Code of New York State or s the New York City Building Code,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table I: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVACPipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)