Loading...
2004-689 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building& Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20040689 Date Issued: Friday, November 19, 2004 This is to certify-that work requested to be done as shown by Permit Number P20040689 has been-completed. - Tax Map Number: 523400-295-020-0001-004-013-0000 Location: 207 'FARR Ln Owner: RICHARD & SUSAN COUGHLAN Applicant: RICHARD & SUSAN COUGHLAN This structure maybe occupied as a: By Order of Town Board Deck TOWN OF QUEENSBURY Director of Building&Code Enforcement -1r TOWN OF QUEENSBURY LJ ,a 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040689 Application Number: A20040689 Tax Map No: 523400-295-020-0001-004-013-0000 Permission is hereby granted to: RICHARD & SI TS AN CO CTULAN For property located at: 207 FARR Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: RICHARD & SUSAN COUGHLAN . 207 FARR Ln Deck $2,000.00 Total Value $2,000.00 QUEENSBURY, NY 12804-0000 Contractor or Builder's Name /Address Electrical Inspection Agency Plans&Specifications 2004-689 224 SQ FT DECK $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday, September 20, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tewn aQueegts u September 20, 2004 SIGNED BY Ilk for the Town of Queensbury. Director of Building&Code Enforcement Porch, Deck, Dock, or Boathouse Permit Application Town of Queensbury—Dept of Community Development, 742 Bay Road, Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. No permit File No. C5q- inspection will be made until applicant has received a valid Fee Paid $ building permit. All applicants' spaces on this application must be Reviewed By: completed and must appear on the application form. Applicant: V t t�Ar4 60'j!)k Owner: �j4'(�1/► Address: 2-0-7 Address: Phone#(S 3) 7 3'� -!Y& yA Phone Email Address: ski ra- (_i) 4 .ote_'f Email Address: Person Responsible for Supervision of Work as Regards to Building Codes: Name R�c kA--cf Address: ]4��644,&7� Phone 2�.3 " GK'V Property Location: Lot Number: / House Number 20-7 (AA-"�' Subdivision Name: hu-A i Aeu. P_i a g;,�- Tax Map Number: car Estimated Market Value of Construction: $ Q� ❑ Porch at"Deck ❑ Dock ❑ Boathouse ❑ Other.work(describe Size of structure to be built 224 square feet RECEVVELD Submit along with this application: r SEP 0 3 2004 1. Two plot plans drawn to scale,preferably using a survJ221129—IM—_ sed structure showing setback dimensions from all property- I of water supply and location and configuration of septic disposal area. 2. Two sets of structural drawings. Indicate size of posts or studs, floor joists, decking or flooring material to be used. Show how the porch or deck will be fastened to the building. If a roof will be constructed, indicate the size of posts or studs,roof rafter spacing and span. Indicate type of roof: sloped, flat, shed, or other. Indicate the type of material being used-for the roof. Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and all prove ons of the Building Code,the Zoning Ordinance and all other laws pertaining to the pro sed work sha a co m 'e w ,whether specified or noted,and that such work is authorized by the caner. Applicant's si ature: Date: L:\SueHemingway\Building.Permit.PORMS\Porch.Porch.Permit.doc 8/13/02 revised per DH Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/ epart: rpm Date Inspection request received: Inspector's Initials: NAME: _ �.:� PERMIT#: J LOCATION: DATE: TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs, decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %2" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup; Carbon Monoxide Detector Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24" access, 1 s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Per nent L:\PamW\Buildiniz&Codes\Inspection Forms\Res.Final Insp. form 2,docLast printed 2/12/04 R-esidentialj Final Inspection Office No. (518) 761-8256 Date InspectionPreqeceved �O a Queensbury Building&Code Enforcement Arrive: °� a p 742 Bay Rd., Queensbuuy, NY 12804 Inspector's InitiNAME:LOCATION: ry)� TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 in. or more @ stairs,decks,patios Guard at stairwell at 34 in.or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut'-off boiler Relief Valve(s)installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every-Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches 3/4 hour fire door/door closer Garage fireproofing Duct work Sealed properly �r Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area ��� Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents G Building No./Address visible from road / Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required . Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C/0(Cert. Of Occupancy) Okay to issue Permanent C/0 (Cert. Of Occupancy) L:\SueHemingway\Building.Codes.Inspectiorr.FORMS\Res.Final Insp.form 2.do ited January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256_ Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/pm epart• am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: ` - r(NAME: \; '� C ? �, „n PERMIT#: LOCATION: QCD ��, .��. INSPECT ON: `. TYPE OF STRUCTURE: Y N N/A COMMENTS F ing � f• Jack Studs/Headers Bracing/Bridging fir` Joist hangers j Jack Posts/Main Beams Exterior sheeting nailed prop rly 12"O.C. Headroom 6 ft. 8 in. lj Stairwells 36 in. or more J Headroom 6 ft. 8 in. i Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side j Draft stopping 1,000 sq. ft. floor trusses ` \ Anchor Bolts 6 ft. or less on center 1 lee and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour 1. Firestopping i Penetration sealed 16 inch insulation in cavity min./ Garage Fire Separation r` House side %2 inch or 5/8 incfy'l ype X Garage side 5/8 inch Type X/ Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) f 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: anvp Depart. am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: � NAME: _ r c C 1.J1 PERMIT#: a0 0 lJ�� LOCATION: c� _ INSPECT ON: TYPE, OF STRUCTURE: Comments ------ __ Y N/A otings Piers X/r onolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Danipproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SucHcmingway\Building.C:odes.Inspection.PORMS\Foundation Inspection Report.doe January 28,2003 Richard Coughlan Queensbury, NY 12804 Wed Sep 01 21:16:49 2004 Construction Specifications deck 1: Construction Method = Beam to Side of Post Footing Type= Pier In-Ground Footing Depth =48" Live Load = 80 Dead Load = 10 Decking Spacing = 0" Joist Spacing = 16" Beam Spacing = 120" Post Spacing = 56" Decking = 5/4X6 .40 Treated Southern Pine No. 2 Beams =2X8 .40 Treated Spruce-Pine-Fir No. 2 Joists=2X'9 .40 Treated Spruce-Pine-Fir No. 2 Posts=4X4 .40 Treated Spruce-Pine-Fir(South) No. 2 Deck Height= 36" Diagonal Bracing = No Deck Skirt= No Joist Overhang =24" Beam Overhang = 12" Decking Deflection Factor=360 Joist Deflection Factor=360 Beam Deflection Factor= 360 Stair 1: Step Width =60" Step Height= 36" Step Rise= 5 3/4" Step Run = 11" Stringers=2X12 .40 Treated Spruce-Pine-Fir No. 2 Risers= 5/4X6 .40 Treated Southern Pine No. 2 Treads= 5/4X6 .40 Treated Southern Pine No. 2 Railing 8: Railing Height=40" Baluster Spacing =3 3/4" Toe Space= 3 3/4" Railing 9: Railing Height=40" Baluster Spacing =3 3/4" Toe Space= 3 3/4" wvt =40"rsaiing =3 3/4" Toe Space= 3 3/4" Railing 1: Railing Height=40" Baluster Spacing = 3 3/4" Toe Space= 3 3/4" Rpiling 6: Railing Height=40" Baluster Spacing = 3 3/4" Toe Space= 3 3/4" Railing 3: Railing Height=40" Baluster Spacing = 3 3/4" Toe Space= 3 3/4" Railing 5: Railing Height=40" Baluster Spacing = 3 3/4" Toe Space= 3 3/4" Railing 7: Railing Height=40" Baluster Spacing = 3 3/4" Toe Space= 3 3/4" Big Hammer DeckBot, Version 5.4, Copyright©2003 Big Hammer, LLC. Portions Copyright© 1989-2003 Cad Quest, Inc. LANE A R R S7202 '4 57'E -46.9 4' 68.35' =625.00 may. CL a 34.67' gy 0 pF avEE�ss��Y TpW11 U p�0 pppE � v 4, �OJ 36.46' ULU 3l� co to, w' :✓1 �, IN `_ 4 3 N g BUILDING, & COD a N REVIEWED BY / z DATE °n — ;,.. OPYla ry�o O. TOWN OF ly i IU limited examination, 0 0= om�ilip+++c•i--witri our comments shall not be oon-cvued as indicating the.- `46� plans a io spp:xw.cations are in full -j 31 • compliar+;e wit'n the Building Codes 148,019 gt019 5 6•w of New Yunc State, FXlL'1 icil u %�uuyi uca i ` d 2,)Z lr2fLc�N� Queensbury, NY 12804 Wed Sep 01 21:17:26 2004 3D View 'AO �s�s ZK .II P�� s 'i y- r � Jill I� M �x s 4«"S er kill, This view is a three dimensional view of the deck. Consult your local building department for your correct building code and fastener requirements. Portions Copyright © 1989-2003 Cad Quest, Inc. Big Hammer DeckBot, Version 5.4.4, Copyright © 2003 Big Hammer, LLC. Kicnara cougnian Queensbury, NY 12804 Wed Sep 01 20:22:55 2004 Deck Layout `1 x Lf 2-y $ - S�S�Iv� This view is a general outline of the dimensions and/or substructure layout of your design. If a deck is to be attached to your house, make sure a solid connection can be made. Your design should be checked by a qualified professional or inspector. Consult your local building department for your correct building code and fastener requirements. Some local building codes require different beam to post connections than what is shown. Portions Copyright © 1989-2003 Cad Quest, Inc. Big Hammer DeckBot, Version 5.4.4, Copyright © 2003 Big Hammer, LLC. rucnara uougnian d 0-0-? Queensbury, NY 12804 Wed Sep 01 21:13:29 2004 Deck Dimensions for Deck 1 I I I I 16, N N N I I N N I N I _ - I Deck 1 ------- 2' 12' 2' 2' 12' 2' 16' Joist Spacing; = 16 in. o.c. Baluster Spacing = 3 3/4" Toe Spacing =; 3 3/4" Railing Height, = 40" This view is a general outline of the dimensions and/or substructure layout of your design. If a deck is to be attached to your house, make sure a solid connection can be made. Your design should be checked by a qualified professional or inspector. Consult your local building department for your correct building code and fastener requirements. Some local building codes require different beam to post connections than what is shown. Portions Copyright © 1989-2003 Cad Quest, Inc. Big Hammer DeckBot, Version 5.4.4, Copyright © 2003 Big Hammer, LLC. Kicnara c;ougnian 1 ?�-7 Queensbury, NY 12804 Wed Sep 01 20:12:05 2004 &Post Layout View for Deck 1 N F' I H Cn O 11, 9��— �: ■�1 i 9 . l l 1 l I I I I BasePoint - - — - — - — N Cn N N o c> -- O This view is a general outline of the dimensions and/or substructure layout of your design. If a deck is to be attached to your house, make sure a solid connection can be made. Your design should be checked by a qualified professional or inspector. Consult your local building department for your correct building code and fastener requirements. Some local building codes require different beam to post connections than what is shown. Portions Copyright © 1989-2003 Cad Quest, Inc. Big Hammer DeckBot, Version 5.4.4, Copyright © 2003 Big Hammer, LLC.