Loading...
2004-718 \ TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20040718 Date Issued: Monday, September 12, 2005 This is to certify that work requested to be done as shown by Permit Number P20040718 has been completed. Tax Map Number. 523400-290-014-0001-007-001-0000 Location: 40 ROCKWELL Rd Owner. T. CRAIG JENKIN Applicant: JENKIN DEVELOPMENT, L.L.C. This structure maybe occupied as a: Garage - 2 Cars Attached By Order of Town Board Residential Addition TOWN OF QUEENSBURY Residential Alteration Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Directot4ANMg& de orc ent Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040718 Application Number: A20040718 Tax Map No: 523400-290-014-0001-007-000-0000 Permission is hereby granted to: TFNKTN DF.VF.T,OPMF,NT. T,.T,.C. For property located at: 40 ROCKWELL Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with die NYS Uniform Building Codes and flee Queensbury Zoning Ordinance. Type of Construction Value Owner Address: T. CRAIG 7ENKIN 269 CHESTNUT RIDGE Rd Garage-2 Cars Attached Residential Addition $200,000.00 QUEENSBURY, NY 12804 Residential Alteration Total Value $200,000.00 Contractor or Builder's Name /Address Electrical Inspection Agency HAYES &HAYES P.O. BOX 109 GLENS FALLS_ NY 12801 Plans&Specifications 2004-718 660 SQ FT RESIDENTIAL ADDITION, 1040 SQ FT ALTERATION AND 624 SQ FT 2-CAR ATT. GARAGE $436.40 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, September 30, 2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration ate.) Dated at the wn o u,�e u rsday, September 30, 2004 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Building Permit Application Town of Queensbuty—Dept of Community Devolopmmt,742 Bay Road,Quoensbury,NY A permit must be obtained before beginning construction, Permit File No, No ispectton will be made until applicant has received a Fee P aid $ � valid building permit. All applicants' spaces on this Reo.Fee Paid application mustbe completed and must appear on the Reviewed ay; _,,; applidazion form. Applicant:- ff +c—!E Cans cj1 &11j Owner' Address: 3 qs O� (5�Y RQ Address: aQo ---------- Phone#C ) �{a Phone Property LoostI=' LBtNumber: ! House Number_1fi-_> SubdivisionNamer Tax Map Number: �—Q O ,J u. 1 —7 New Building'.xOrs /commercial •EstimatedMarket Value ofConstruction; $ Addition: %cornutoreiat If ah Addition;what use of new ad Lion be? Alteration: commercial a hto cbange tozosidenco/com'1 C Other wank(dotcdbe Check OceupancyWormation 1 Floor 2 Floor Other floor Total Below sq.ft sq.ft. sq.ft. Square Feet M� a asp Sin .a*=4 dwellin T9 0 " 1 o Two f=ily dwelliu o Townhouse 0%® a multifl=ily dwelling \'S #of units o Office a M=. e c Msau�otutliz 0 1 oar detached 2LA10 11 2 oat dstached EnLo O 3 ow detached prage, O 1 car Attached&=go 2 cat attstahed gmge 2 a 3 car attached dgmse, o St=p building- oommorcial O Storage building- residentlaY a Other What is the proposed height of the structure _feet inches Will any second-hand or ungraded lumber be used? If so,for what? Type of Heating System electric/ oil / gas wood creed hot a / baseboard/other: ,-_ Number of ZjMqk=to be installed _j2-_ N=ber of .Uffgyf,1 to bo installed List below the person(s)responsible for supervision of work as regards to building codes: - -- Address Phone Number Builder I k4ov,E5 - CG-3 / Plumber Maeoa Eloctriciaa please aiga below after you have carefully road rho statement: To the best of my lmowledga the statements contained It,this application,together with the plans and speoifications submitted;are a trm and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether spooMod or noted,and that such work is authorized by the owner, Further,it is uadorstood that 1/we shall submit,prior to a Certiticato of Occupancy or Cettificato of Compliance being issued,as zequested by the Zoning Admiaiatxatox a B ding_and Codes,an,As Butt&rvev by a licensed surveyor;drawn to sealo,showing actual location of all cc 0 Signmture; Mae actor e Code Required Lighting and Ventilation Project: Craig Jenkins Date: 4 o C]GwL u- Room Designation Room Area Required Light 8% Actual Light Required Ventilation Actual Ventilation - of Room Area(W) Provided (W) 4%of Room Area (ft) Provided (fe) Kitchen/Dining 362.0 29.0 30.7 14:5 17.2 Study 159.0 12.7 28.5 6.4 15.9 Living 450.0 36.0 38.0 18.0 22.2 Front Bedroom 125.0 10.0 10r o 5.0 517 Master 200.0 16.0 34.2 8.0 18.8 Reading 120.0 9.6 14.8 4.8 8.7 Notes: 1.All habitable rooms shall be provided with aggregate glazing area of not less than 8 percent of the floor area of such rooms. Natural ventilation shall be through windows, doors, louvers, or other approved openings to the outside air. Such openings shall be provided with ready access or shall otherwise be readily controllable by the building occupants.The minimum openable area to the outdoors shall be 4 percent of the floor'area being ventilated. 2. Glazed areas need not be openable where the opening is not required by Section R310 and an approved mechanical ventilation system is provided capable of producing 0.35 air changes per hour in the room. 3. For the purpose of determining light and ventilation requirements,any room shall be considered as a portion of an adjoining room when at least one-half of the area of the common wall os open and unobstructed and provides an opening of not less than one-tenth of the floor area of the interior room but not less than 25 square feet. 4. Bathrooms,water closet compartments, and other similar rooms shall be provided with aggregate glazing area in windows of not less than 3 square feet, one half of which must be openable. 5. The glazed areas of bathrooms,water closet compartments, or similar rooms shall not be required where artificial light, and a mechanical ventilation system are provided. The minimum ventilation rates shall be 50 cfm for intermittent ventilation or 20 cfm for continuous ventilation, Ventilation air from the space shall be exhausted directly to the outside. Check Residential Plan Review: One&Two Family Dwellings Y/N/N/A T)O Fi ts of plans ,500 sq. ft.—Stamped Design Loads On Plans:90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size �� �� e� �;d� s✓�,�,,� .c Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofing/Waterproofing Materials On Plans Foundation Drainage On Plans,if required 6"Drop in 10'Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise Winder Run and Rise ; r Spiral Not Allowed From 2 Story ' Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped Attic Access 2c- �w— Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level ,� c� Soil Test Results,if requiredrevlO v1 Cr ._— Septic To Well Or Water Line Separation Al]Paperwork Signed Via;>:.C'• _ Project Name: U..e, k'ns BP# Address: 410 4C,LIe U 9J Building Pernut Submission SFD (Checklist 2-Family All items below must be checked either yes,no or not applicable prior to submission of any boding pemmit to the Town of QueensbwyBuWing Department If any of the below items we}asking,the permit. will not be accepted until such time as the application is deemed complete for submission. 1. Buil&g Pemmit Application Completed ..................................... ❑yes ❑no D n/a 2. EnaUFonn or CheckNLte EnaUCbde Compliance Fours Complete.. D yes Ono ❑n/a (2 copies) 3. Energy Code Inspector's Report from GheckMate Program............ ... .. ❑yes ❑no ❑n/a (2 copies) 4. Septic application completelyfilled out(if applicable)........................ ❑yes ❑no ❑n/a 5. Solid Fuel Bunting or Comas Appliance Form... ........................... ... ....Dyes Ono On/a b. Electrical Inspection Form......... Dyes Ono ❑ 7. Two(2)complete sets of sttvctwal drawings................................ ....-Dyes Ono ❑a/a a)floor plan;b)foundation plan;c)cross sections:d)elevations; e)window and door schedule S. Two(2)site plans showing location of'the structme to be bush....... ...... Dyes []no 'On%a location of well or water lines,location of septic system or sewer line. 9. Setbacks from property lines to new structure.............................. .. Dyes Ono ❑n/a 10. Setbacks to neighboring wells and septic systems,including onsite well.... Dyes Ono On/a and septic systems(d applicable) 11, DrivewayPermit.................. ... ....................................... ...... Dyes Ono On/a Date: Staff Initial: *Y--:�^..... R••:�a:.�n��,���f�RMS\Generic C7iecklist.doc January28,2003 Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY (518)761-8205 Application for Fuel Burning Appliances & Chimneys applicable to solid fuel & vented gas appliances Date ;l , 20�' Permit No. (� ��. F ( Application is hereby made to the Building& Codes Office for the issuance of a Building and Use Permit pursuant to the New York State Fite Prevention and Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. NOTE to applicant: Rough-in and Final Inspections are-required. Applicant Information Fuel Burning Appliance Information (circle appropriate words) Name: r,5- ,­tj5-7' Q C-7 7 6IJ Stove: �ocl coal pellet gas Fireplace insert Address: '�� f � 6 9 Fireplace, factory-built: wood gas AJY'* /Mt) Fireplace, masonry: wood gas Furnace: wood gas oil Phone: -7 1 If non-masonary applicance, please provide Owner: C 1Z--A,-i C } (A .$_ Manufacturer Name: Address: .Model Number: B� ' Chimney Information Phone: (circle appropriate words) Masonry block brick stone Flue the stee size.' inches Exact Address: o (ey kt,.e It of construction or installation Factory-Built Manufacturer name; Y�7 Model Number: 0 Note: Listed By: —Number: -_ Construction/Installation must conform to NYS Fire Prevention &Building Indicate (circle) chimney material: Code. Consult available Town of Queensbury Handouts regarding required inspections. `Dou� r1 / TJ'iple wall / Insulated / Direct venting Chimney Liner ICa.s�iieac-'ier��,� ®��--T®�� 0�1�7►ax��ai,c�X'u�-y, �T��7[�or..�: Fire Marshal Code# S Collected 8 Refunded Received front (refunded ro). A 173 3389 (190) Public Safety A 233 2655 (230)Minor Sales DATE: Q — I- _(_; - f 7. 044k.i D-P--7 \ White(Applicant) / Green(Fire Marshal) / Yellow(Bldg.Dept.) / Pink&Goldenrod(Cashier's Dept.) 1 Application for Permit---Septic Disposal System Town of Queensbury 742 Bay Road Queensbury,MY 12804 (518) 761-8256 1. OWNER INFORMATION: ............................................ Office Use Location of installation: 4 File Permit No. Tax Map No. Fee Paid Owner's Name: Address- 0 2. INSTALLER'S NAME (&XT72W& j< 0' PHONE NO. 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply #of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x- Computation = Total Daily Flow 1980 or older x 150 gal/bdrm = 1980- 1991 x 130 gal/bdrm = 1991 —present x 110 gal/bdrm = Garbage Grinder Installed yes no' Spa or Hot Tub Installed yes no 4.' PARCEL INFORMATION: (circle applicable information&indicate measurements) Topography Soil Nature Ground Water Bedrock or Impervious Material Domestic Water Supply Ciz> I at what depth at what depth municipal Rolling feet feet ar Steep slope clay if well; water supply %slope other from-any septic-system depth: absorption is ]n ft- other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: �- _minute per inch 5;eU HArZ C-),hf, ch-rj 4 /06:5/di jevpb 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: 12S-D gallon (min. size 1,000 gal.) Tile Field: each trench ft. Total System Length: 0 ft. (6-X11577,-16) Seepage Pit(s): number of size of each: _ft, by_ft. Size�f Stone to be used: # depth or thickness feet Bed.System Size: x Alternative System:- length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: 1 Size of each:_gallons TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. SignaturWof responsible person Date . �•l'<rtvre•uf tZutrc�ri�lnii•,y Sc;tivcrs :�r�tl 4cw;lj,,c Disimsal Chapter AIrpmulix C. r • /l'1�,�()ILI'''1'ItI�I II'l i;�I�I.> . 9 'PA1t11,'I ION ItY,'QUI ItI+N111INTS r ' 1 pgwp �"' Y'��LL. tN ll�t1''sL• '` � �+�t t<',4•i o. rr _rrw�+�r' • t G ell, • •b ' ' t'PdY I�. L ..._._:.» � \ ���,.-..•- .ram � il�attttt:ilttr�tt � • AxJJtTRI'iK1 r • 7, SlaNATURE &WORNIA71ONFOIL USFUNSWLZ Residential Final Inspection Office No. (518)761-8256 Date Inspection re lest r c iv Queensbury Building&Code Enforcement Arrive: am/p epart: a a� 742 Bay Rd., Queensbury,NY 12804 Inspector's Initi ls: NAME: �r�}�1 � P IT#: LOCATION: �fl t\� ` t R. - TE: TYPE OF STRUCTURE: Comments �f Y N N/A r Chi ey Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 in. or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs.' or more risers Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off ex osed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area VL Furnace/Hot Water Heater operating Low water shut=off boiler Relief Valves installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing Interior Smoke Dete,Etors: / Every level: ,/ / Every Bedroom: Outside every bedroom ea: I / Inter Connected: V / Battery backup: �! Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency a ess below grade Basement stairs closed rise>4 inches 3/4 hour fire door/door closer Garage fireproofing Duct work Sealed properly Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical . Site Plan [Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker 6j-y-JTj j—� Flood Plain Certification,if required Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C/0(Cert. Of Occupancy) Okay to issue Permanent C/0(Cert. Of Occupancy) L:\SueHemingway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doe edited January 28,2003 Queensbury Building & Code Enforcement - R 1a inal Inspectio t7N Office No.(518)761-8256 � Arrive: am/p �,epaT. —1 a��My Date Inspection request received: I /41 �> Inspector's Initi ls: NAME: - A- e Sf'� e S � �i h �Q'Y IT#: G e — / � LOCATION: 'G v(: w2 ( � - TE: Z TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs, decks,_patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %2" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: - / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches ff Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker , Flood Plain Certification, if required Mkay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res, Final Insp. form 2.docLast printed 2/12/04 Queensbury Building & Code Enforcement - Re ' ti nal Inspection . Office No.(518)761-8256 Arrive: am/pm art: a Date Inspection request received: _ Inspector's I itia _ NAME: ,�, O ~ LOCATION: 1 v E: — TYPE OF STRUCTURE: �;�,_ _ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete '(1 Guard 30 in.or more a)stairs, decks,_patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more , Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors � 12-►�-��� ���� T© �,��i� Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %Z" Gypsum Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall �bt-LE9 6 inch clearance to sill plate ���;1� < t t Gas Valve shut-off exposed/regulator 18"above grade Gas'Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating -Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tem 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures NwFoundation insulation Floor truss,draft stopping finished basement 1,000 sf � Emergency egress below grade Basement stairs closed rise>4 inches, e!/' Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer L Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure v Attic access 30 in.x 22 in.x 30 in.(ht:)In accessible area Crawl.Spaces 18"x 24" access, 1 s . ft.-150 s .ft. vents Building No./Address visible from road Final Electrical Site Plan /Variance ce uired ------- Final Survey Plot Plan , As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Tem ora ermanent L:\PamW\Building&Codes\Inspection Forrns\Res. Final Insp. form 2.docLast printed 2/12/04 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspectio?T #: Queensbury Building & Code Enforcement Arrive: art: `,- 742 Bay Road, Queensbury, NY 12804 Inspector'sNAME: �7 n LOCATION. INSPECT ON: TYPE OF STRUCTURE: , l � Rough Plumbing / Nail Plates Y N loi/A .V Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test VAa Water Supply Piping ��� `3 Air Head P.S.I for 15 minutes nsulation / Residential Check/ Commercial Check Proper Vent Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&CodesUnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection reque rec v d: Queensbury Building& Code Enforcement Arrive: pm, epart: ��arQpm 742 Bay Road, Queensbury,NY 12804 Inspector's Initi 1 NAME: ��E���� 1 ���i PERMIT #: -ObO =7 LOCATION: R L�C- s(-L�L� R UP�n INSPECT ON: 4 TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/ Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min. Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper, CPVC,Pex One and Two-Family �k Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed ro erl /No duct tape COMMENTS: 0UT-F-Q -TU L:\SueHemingway\Building.Codes.[nspeetion.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection reqram s� recb'fed: Queensbury Building & Code Enforcement Arrive: /pry part: ' D am� 742 Bay Road, Queensbury, NY 12804 Inspector's Initialls:-- NAME: PER . #: �� _7 ^ -1/p LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates 4 Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / ead 5 S.I for 15 minutes nsulation / Residential Check / Commercial Check Proper Vent Attic Vent �\ Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection FormslRough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection requ e iv U� Queensbury Building& Code Enforcement Arrive:VAV a D art:, a p 742 Bay Road, Queensbury, NY 12804 Inspector's Initial NAME: ;� — � '7 ( � PERMIT#: G 7 LOCATION: W INSPECT ON: p TYPE OF STRUCTURE: ,n-_ Y /a COMMENTS Framing \ Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or moreQ Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center / Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour D �� I—re stopping / ene ation sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade 1-ASueHemingway\I3uilding.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Rough Plumbing I Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request/re pived; Queensbury Building & Code Enforcement Arrive: am,/pm!' Depart: am 742 Bay Road, Queensbury, NY 12804 Inspector's Initia'Is:_�-/ `r ` F NAME: �� r' PENT #: LOCATION:_ L c! INSPECT ON: TYPE OF STRUCTURE: Y N N/A h Plumbing / Nail Plates -77 Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping �'' � "`' Air / Head 50 P.S.I for 15 minutes Insulation / Residential Check / Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation �.��v If required unheated spaces Combustion Air Supply for Furnace _ �-� Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005 Rough Plumbing Insulation Yns ec' Wn e p rt Office No. (518) 761-8256 Date Inspection request re�e . Queensbury Building & Code Enforcement Arrive: a __art: Z as gym 742 Bay Road, Queensbury, NY 12804 Inspector's Initial NAME: FERMI #: I c LOCATION: CSC" INSPEC ON: TYPE OF STRUCTURE: Y N / N/A khPlumbin / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction —� Pressure Test �� Drain / Vent l� � Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes '\7 Pressure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check / Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape �2 i� 'nC)-V\Or'_\ LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Rough Plumbing Insulation Inspect on Report Office No. (518) 761-8256 Date Inspection requestINQueensbury Building & Code Enforcement Arrive: a , ppart: C! -L-b m 742 Bay Road, Queensbury, NY 12804 Inspector's Initials NAME: PERMIv t. LOCATION: 7c_ INSPECT ON: 0-6 TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanoutt-eve 100 feet / change of direction Pressure Test Drain / Vent Air / Head- 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure`Test ^, Water Supply Piping Air/ Head / 0 S. ,, I for 15 minutes elation /.,Residential Check / Commercial Check Proper Vent Attic Vent _ Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: ov tie;>�� ► 1� Cat L1 '��,V-3&� LAPamm Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report J � / Office No. (518) 761-8256 Date Inspection request received: / Queensbury Building& Code Enforcement Arrive: am/ m Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center nd snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side '/2 inch or 5/8 inch Type X Garage side. 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHeminmvay\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection reques cei 1/ US Queensbury Building&Code Enforcement Arrive: am/ m art: m 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: s ` � PERMIT#: LOCATION: INSPECT ON: 5 TYPE OF STRUCTURE: Y N N/A Frami COMMENTS Jack Studs/Headersp Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %s (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Iee and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemin,-Way\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Re .art Office No. 518 761-8256 ( ) Date Inspection eq - �rece ed: Queensbury Building&Code Enforcement Arrive: I. �a epart: 3=00 arr4m 742 Bay Road, Queensbury, NY 12804 Inspector's Initia\ NAME: PERMIT#: 7 f U LOCATION: INSPECT ON: _ U� TYPE OF STRUCTURE: Y, N N/A COMMENTS raming 1 Jack Studs/Headers / `� i .M G �'� , Bracing/Bridging Joist hangers Jack Posts/Main Beams t,� k�Li✓ A�������t�-►L �� � Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. 3 Stairwells 36 in. or more Headroom 6 ft. 8 in. � 13- Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 /2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center ��� P�� • Ice and snow shield 24 inches from wall 12pE� Fire separation 1, 2, 3 hour 6p Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Mtn �pL� Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) N�t1L� 1t 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: S Queensbury Building &Code Enforcement Arrive: QjJ am/pm Depart: am,pm 742 Bay Rd., Queensbury, NY 12804 Inspector"s_Htials: I),L NAME: y�� _ PERMIT#: 69LI 7l d LOCATION: E:00 INSPECT O—: o `— TYPE OF STRUCTURE:— —�'— Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: r 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval , Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. LASueHemingway\Boilding.Codes,InspectionTORNIS\roundation Inspection Report.doc January 28,2003 0 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: �Lj am/pm ,� Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: �� n PERMIT#: _ -�_ O LOCATION: INSPECT ON: TYPE OF STRLJCTURE: Comm6�s ents Y N N/A Footings Piers Monolithic Slab Reinforcement in-Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Found ' n Dampproofing undation/Waterproofing Type of Dampproofing/Waterproofing j'�/V/�� tbvA &1✓ 4,'���— Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. I;\SueHemingway\Bui]ding.Codes.InspectionTORMSToundation Inspection Report.doc Januaiy 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: :20 am/pm Depart: am/p 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: 4 L/ PERMIT#: LOCATION: INSPECT ON: L TYPE OF STRUCTURE: Commen Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing c� Z11-62cex Type of Dampproofnig/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 roil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\.SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection equest ecei e i-- ueensb Building &Code Enforcement Arrive: am/ m Depart. a m Q �'Y b p p �� p 742 Bay Rd., Queensbury,NY 12804 Inspector's itials: " NAME: ye �L << ,1 IT#: (�� LOCATION: ✓/() c c.l e-i vQ_� SPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in-Place The contractor is responsible for C� b-A�: providing protection from freezing p,r for 48 hours following the placement `► of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place J�s�;: , �w Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. L:\.SueHemingway\Building.Codes.Inspection.FORMS\foundation Inspection Report.doc 7anuaiy 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection r uest e ei d: Queensbury Building &Code Enforcement Arrive: m/p Depart: anv` 742 Bay Rd., Queensbury, NY 12804 Inspector's Initia NAME: ���'�'� � � P IT#: LOCATION: c� �� � c INSPECT ON: �= TYPE OF STRUCTURE: Comments Y N N/A ootings 1r Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/ Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Duil ding.Codes,InspectionTORNISWoundation Inspection Report.doc January 28,2003 . a Foundation Inspection Report Office No. (518)761-8256 Date Inspection re st re Queensbury Building &Code Enforcement Arrive: a pm epart: an gW? 742 Bay Rd., Queensbury,NY 12804 Inspector's Initia s: / ��/ NAME; _ 1 ,(�S IT#: _v T LOCATION: INSPECT ON:` TYPE OF STRUCTURE: Comments Y N NT/A Footings Piers r �c� Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wall.pour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab _ Bacicfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.InspectionTORMSToundation Inspection Repoa.doc January 28,2003 F \ � o't> /0-/ Rough Plumbing /- Insulation Inspection Report Office No. (518) 761-8256 Date Inspeje Queensbury Building& Code Enforcement Arrive. part: a pm 742 Bay Road, Queensbury,NY 12804 InspectNAME: ���m T #:LOCATION: T ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Copper Commercial 0o er, CPVC,Pex One and Two-Family nsulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: LASueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 r.. C�) Foundation Inspection Report Office No. (518) 761-8256 Date Inspection r est r c ve Queensbury Building &Code Enforcement Arrive: am/p Depart: . (!!v`pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initi , l NAME: _ 1 PERMIT#: v LOCATION: INSPECT ON: TYPE OF STRUCTU E: — cc Comments Y N N/A l ootings Piers Monolithic Slab Reinforcement in Place / The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/ Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspectio requesgecjf-.id: Queensbiu-y Building &Code Enforcement Arrive: am/pDepart: an ' in 742 Bay Rd., Queensbury,NY 12804 Inspector's IIlI NAME: �� 'P� \ ERMIT#: ( LOCATION: p<� ) INSPECT ON: TYPE OF STRUCT E: Comments Y N N/A ootings Piers Monolithic Slab Reinforcement in Place �—�� l��7 �Fl The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Btd1ding.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: _11—k am/pm Depart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: �' PERMIT#: LOCATION: INSPECT ON: ° (a TYPE OF STRUCTUR Comments Y N N/A Footings Piers Monolithic Slab // //" Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Bui1d InspectionTORMS\l:oundation Inspection Report.doc January 28,2003 Foundation Inspection Report p P Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Depart 1 am/pm A 4v 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: ��`� \�1 PERMIT#: ��— LOCATION: INSPECT ON: TYPE OF STRUCfURE. Comments Z. Y N N/A ootings Piers Monolithic Slab Q Reinforcement in Place 'U The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofmg/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 1.2 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.Inspection.FORMSToundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm part: 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: - ` PERMIT#: _7 j LOCATIO UG INSPECT ON: D TYPE OF Conunents Y N N/A C�l " iefs � Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation,Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Bui]ding.Codes.Inspection.FORMS\Foundation Inspection Reportdoc January 28,2003 64 --- 71Y Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lc Data filename: C:\Program Files\Check\REScheck\jenkins.rck COUNTY:Warren STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE:09/13/04 DATE OF PLANS: 8/18/04 PROJECT INFORMATION: Jenkins 40 Rockwell COMPANY INFORMATION: Hayes Construction NOTES: Entire house included in analysis COMPLIANCE:Passes Maximum UA=713 Your Home UA=539 24.4%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 1580 38.0 0.0 47 Ceiling 2: Cathedral Ceiling(no attic) 660 30.0 0.0 22 Wall 1:Wood Frame, 16"o.c. 1710 19.0 0.0 87 Window 1:Wood Frame:Double Pane with Low-E 134 0.360 48 Door l: Glass 112 0.320 36 Door 2: Solid 20 0.140 3 Wall 2:Wood Frame, 16"o.c. 1420 19.0 0.0 75 Window 2:Wood Frame:Double Pane with Low-E 168 0.360 60 Basement Wall 1: Solid Concrete or Masonry 1290 11.0 0.0 85 Wall height:7.8' Depth below grade:6.5' Insulation depth:7.8' Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 390 30.0 0.0 13 Floor 2: Slab-On-Grade:Unheated 82 10.0 56 Insulation depth:4.0' Crawl 1: Solid Concrete or Masonry 80 11.0 0.0 7 Wall height:4.2' Depth below grade:3.0' f Insulation depth:4.0' Furnace 1:Forced Hot Air,92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compl' ce wi s Code. Builder/Designer Date / I �OF NEwy L W. R yq 0 n � t '0.0 y0. 07906Q� ROFFssioNPy' REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lc DATE:09/13/04 Bldg. I Dept. 1 Use 1 I Ceilings: [ ] 1 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: [ ] I 2. Ceiling 2: Cathedral Ceiling(no attic),R-30.0 cavity insulation Comments: I Above-Grade Walls: [ ] I 1. Wall 1: Wood Frame, 16"o.c.,R 19.0 cavity insulation Comments: [ ] 1 2. Wall 2:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: I Basement Walls: [ ] 1 1. Basement Wall 1: Solid Concrete or Masonry,7.8'ht/6.5'bg/7.8'insul, R-11.0 cavity insulation Comments: I I Windows: [ ] 1 1. Window L Wood Frame:Double Pane with Low-E,U-factor:0.360 For windows without labeled U-factors,describe features: I #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 1 2. Window 2:Wood Frame:Double Pane with Low-E,U-factor:0.360 For windows without labeled U-factors,describe features: I #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: I Doors: [ l I 1. Door 1: Glass,U-factor: 0.320 Comments: [ ] 1 2. Door 2: Solid,U-factor: 0.140 Comments: i Floors: [ ] I 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation Comments: [ ] 1 2. Floor 2: Slab-On-Grade:Unheated,4.0'insulation depth,R-10.0 continuous insulation 1 Comments: Slab insulation to extend down from the top of the slab to at least 4.0 ft.OR down to at 1 least the bottom of the slab then horizontally for a total distance of 4.0 ft. Exterior insulation must have a rigid,opaque,weather-resistant protective covering that I covers the exposed(above-grade)insulation and extends at least 6 in.below grade. I Crawl Space Walls: [ ] I 1. Crawl 1: Solid Concrete or Masonry,4.2'ht/3.0'bg/4.0'insul, 1 R-11.0 cavity insulation Comments: 1 Applies to walls of unventilated crawl spaces. I ' Heating and Cooling Equipment: [ ] I 1. Furnace 1:Forced Hot Air,92 AFUE or higher Make and Model Number I Air Leakage: [ ] I Joints,penetrations,and all other such openings in the building envelope that are sources of air I leakage must be sealed. [ ] I Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly I with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a I 3"clearance from insulation. I Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. I Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] I Materials and equipment must be identified so that compliance can be determined. [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] I Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. I Duct Insulation: [ ] I Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] I Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] I Supply ducts in unconditioned spaces must be insulated to R-11. Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. I Duct Construction: [ ] I All joints;seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts I operating at less than 2 in.w.g. (500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] I The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. I Electric Systems: [ ] I Separate electric meters are required for each dwelling unit. I Fireplaces: [ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] I Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction I provisions of the Building Code of New York State,the Residential Code of New York State or I the New York City Building Code,as applicable. I Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the I water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Circulating Hot Water Systems: f 1 I Tnc.�loto rirr»lotinrt hnt motor pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non=Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low-Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.'5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) !: CV f, �o 3 it co LA- >7 s)PEsN�L� c00n �z Z in 6Ar2e4C z m � AIR ,. \ S�P-nc Fi E LD ti � LL o ,4 D(Ji T1011 ` tL- z \ V) D \\ o 00 So�Doa 3a5 Z LO W \ r" lam-• P���I o�S ( D�c,ucw�Y ILSL,6,p,U,D ,; T co �I �� Tr-, Pia,," y Q in LL- O X V) O m J J d- LL cD O pc � to 3M0£'�80460N O u