Loading...
2004-939 TOWN OF QUEENSBURY FILE !" Y 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20040939 Date Issued: Monday, June 13, 2005 This is to certify that work requested to be done as shown by Permit Number P20040939 has been completed. Tax Map Number: 523400-315-010-0001-010-000-0000 Location: 32 QUINCY Ln Owner: MICHAELS GROUP LLC THE Applicant: MICHAELS GROUP LLC THE This structure may be occupied as a: Fireplace By Order of Town Board Garage - 2 Cars Attached TOWN OF QUEENSBURY Single Family Dwelling Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20040939 Application Number. A20040939 Tax Map No: 523400-315-010-000 1-0 10-000-0000 Permission is hereby granted to: MICHAELS GROUP LLC THE For property located at: 32 QUINCY Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: MICHAELS GROUP LLC THE 10 BLACKSMITH Dr Fireplace MALTA,NY 12020-0000 Garage-2 Cars Attached Single Family Dwelling $262,900.00 Total Value $262,900.00 Contractor or Builders Name/Address Electrical Inspection Agency MICHAELS GROUP SUITE 1 10 BLACKSMITH Dr MALTA,NY 12020 Plans &Specifications 2004-939'LOT 10 HSE#32 QUINCY LANE 2003 SQ FT SINGLE FAMILY DWELLING $296.36 PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday,December 10,2005 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T o een�bry;,t i y,December 10,2004 SIGNED BY /t7 for the Town of Queensbury. Director of Building&Code nforcement Building Permit .Application 'Town of Q icensbury—Dept of C ollllllL'inity Development,V42 Bay Road, Queensbury,N�' ���`� (518)761-8256 . 'GS l a A permit must be obtained befoie�bcginning construction. Permit file No.. 0 '�� No inspection will be made until applicant has received a Fce Paid a-°l� br-IVEDia�. valid building permil. All ❑pplicanls' spaces oil this Roc. Fee Paid $ !)C-� application must be completed and must appear on the Reviewed .By: Qv ; Q 2004 application form. C+ TOWN OF QUEENSEURY Applicant;� - �� Owner: �a � 6U11 CLING AND CODE Address: Address: Phone# 051 )Mck -Lail- Phone## Property Location: Lot Number: 10 / House Number 3 Z / c.�i►_-)c-`e LA>v-�E Subdivision Name Tax Mal) NL1111bC1-: XNew Building: residence /conlnlercial Estimated Market Value of Construction: $ Z-eaZ ► cl(DO ❑ Addition: residence/ commercial If an Addition, what will use of new addition be? ❑ Alteration: residence! commercial ❑ No change to exterior size: residence/conl'l C1 Other work(describe ) Check Occul)ancylnrol-111allon 1" Floor 2"' r1oo1- 0(her 11001. Iblal IlefolV sq.ft. sq. ft, sq. ft. Square Feet 3� Single family dwelling _ 1`SZ a 475 ❑ Two family dwelling ❑ I•owl�louse ❑ Multifamily dwelling - #of units ❑ Office ❑ Mercantile ❑ Manufacturing ❑ 1 car detached garage ❑ 2 car detached garage ❑ 3 car detached garage ❑ 1 car attached garage 00 >ED 2 car attached garage 560 ❑ 3 car attached garage _ v d Sloi-agc building- conlillercial ❑ Storage building- residential ❑ Other Will any second-hand or ungraded lumber be used? If so, for what'? Type of heating System: electric/ oil / gas wood / forced hot air/ baseboard/other: Number of Fireplaces to be installed I' Number of Woo(Woves to be installed �. . List below the person(s) responsible for supervision of work as regards to building codes: Name Address Phone Number Mason J D 50uc.-1� $OyC Ztoe 41Zjt" V1%_t_.'. 1032 - 91 se Electrician Al F_',E '� �1-�3-'fRl C 'SOlA 1'2 fr 'T +- %.Nt4_ M Declai'atl(111: please sigil below after you have carefully read the slalcnlenl: To the best of my knowledge the statements conlained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Cole, the ZOIIIIIg OI'(IIIlaI1CC all(] aII QtIICI laws 17eflalt1111g to the propOseCl R'UI'k shall he complied with, whether specified or noted, and Thal such work is authorized by the owner. l,urlher, it is understood that i/Fvc shall subnlil, prior to a Certificate of Occupancy or Certificate of Compliance being issue(], as requested by the Zoning Administralor or Director of Building and codes,an As Built Surrej by a licensed surveyor; drawn to scale,showing actual location of all new collstructi Si Mature: ---- owner,owner's agent, architect,contractor Check Residential Plan Review: One&Two Family Dwellings Y/N/N/A 2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans:90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. 24"(h)x 20"(w)min. 44"Max.Hei t above floor esidential Check Paperwork Compliance and Inspectors Checklist: OK ampproofing/Waterproofing Materials On Plans oundation Drainage On Plans,if required "Drop in 10'Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where Re uired Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls atforms At Exterior Doors irway Headroom 6' 8'All Stairs 36"Width Stair Run and Rise Winder Run and Rise r' Spiral Not Allowed From 2d Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,36"min. ,Vlandrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. #(A-�Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results,if required Septic To Well Or Water Line Separation All Paperwork Signed Application for Permit=Septic Disposal System Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 1. OWNER INFORMATION: ......................................................................................... Office Use Location of installation: 3 z G\D)►..)cY L-A-Ne I File Permit No. 0Y`�3 Tax Map No. Owner's Name: Tke Nix C..FkI:�,Qs G you f ...... . .........�....................... ............ ...... -�.. Address: VD FnLA-r-V-Sv-AVVA 'Pekes E j MA-k5 A, KW NOV 3 0 2004 TOWN OF QU RY 2. INSTALLER'S NAME : BUILDI E 3. RESIDENCE INFORMATION: (circle year of dwelling,indicate#bedroom(s) and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gal/bdrm = 1980- 1991 x 130 gal/bdrm = 1991 -present Z. x 110 gal/bdrm. = Garbage Grinder Installed yes_ / no. '-je Spa or Hot Tub Installed yes_ / no - - 4: PARCEL INFORMATION: (circle applicable information&indicate measurements) Topogaphy Soil Nature Ground Water Bedrock or Impervious Material . Domestic Water Supply lat 1 load at what depth at wh t depth unici a Rolling m _Jj1/',feet feet well Steep slope clay if well; water supply _%slope other from any septic-system depth: absorption is ft. other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: minute per inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: 100 gallon(min. size 1,000 gal.) Tile Field: each trench 56 f 1. Total System Length: /5 0 ft. Seepage Pit(s): number of size of each: ft. by ft. Size of Stone to be used: *# depth or thickness feet Bed System Size: x Alternative System: < length and/or size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: gallons /TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by_a Town.approved -- —electrical-inspection agency. - _ --- 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensb Sanitary Sewage Disposal Ordinance. Signatu of-responsible person Dat AI)pmulix t: ' SI;I'111t11,'i'1L)1�1 I�I;t,Zt,J.IiLI�h3I�IRt'I';i 1 HlELt. ik t�hr�•�• -. .r►►� u�.vt . .�j 7r I�I nQ. ' r�►�rc 4 . 1�.>t7RPtK1 t f`�0.1•b RUhti ,..................... - 7. Sl(NX&TURE __A Queensbury Building & Code Enforcement - Residential Final Inspection .` Office No.(518)761-8256 Arrive: am/p D part: / `J_am/pm Date Inspection request received: _ _ Inspector's Initials: 31 _- NAME: C CLQ,,Q G_r PERMIT#: r l J9 LOCATION: DATE: TYPE OF STRUCTURE: _ Comments X1,N I N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake _/ / 3 inch Plumb Vent through roof minimum 6" J Roof Co lete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum ''/2" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/<hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in,x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24''access, 1 s . ft.-150 s . ft.vents Building No./Addresi yhbtVfrornro Final Electrical Uil , Site Plan /Variance a uir Final Survey Plot Plan As Built Septic System/Se r e t. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res, Final Insp. form 2.docLast printed 2/12/04 Town of Qucensbury Fire Marshal 742 Day Road Queeusbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace/Stove Inspection Report Notice:New York State requires that all UL Fisted,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's �7 instructions or specifications is allowed. Permit# � " l Schedule Inspection(t —0 c:� Time^ pm anytime Inspector ddress_ l Hough In lnal_ Appliance Manufacturer Model# Direct dent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Firestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth Extension (if any) Mantel Height above f/p opening Witness Operation Tarok Placement(if FP) WMte—BididingDept. J Yeilow Glut er 1 Pink—irfreMarshal I NACE ENGINEERING, P.C. 169 Haviland Road, Queensbury,NY 12804 Phone-518-745-4400 Fax -518-792-8511 G June 6 2005 Job#46176 New York State Dept. of Health 77 Mohican Street Glens Falls,NY 12801 RE: Quincy Lane Subdivision- Queensbury(T) 32 Quincy Lane(Lot# 10) Septic System Dear Sir/Ma'am: This letter is to inform you that we inspected the completed septic-system for the house at 32. Quincy Lane(Lot#10)in the Quincy Lane Subdivision on May 27, 2005. The septic system as installed was for a four bedroom house and consisted of a 1,250 gallon` septic tank_ and 343 lineal feet of absorption trench constructed with stone and perforated pipe. The system conforms to the requirements of the approved subdivision design drawings.. . Please call me if you have any questions or concerns. Sincerely, Thomas R. Center Jr.;PE cc: aye Hahn 3Town ofQueensbuy Eric Wilson,The IVlrchaels'Group MAP REFERENCE: INCY LANE SUBDIVISION THE MICHALES GROUP BY: VAN DUSEN do STEVES DATED: APRIL 15. 2003 LAST REVISED: JUNE 10. 003 ti yo LOT 9 4 Af I250. �I 3R'TIC TAiiC LOT 11 °qLI:` + O oe AfflownON TIMM + N �$ n eaoc LOT 10 2.74 acres 119,462 sq.ft. \ J " J SEPTIC SYSTEM AS BUILT ,���,��i�SYSTEM a ei MAY 4, an u S e A� AY "�""=LAND N OR A0Y41pN 1O A SURVEY Map of a Survey made for Scale 1'=40' YAP BEHIND "" 7lRMEa1S ZEAL ISA A YaN81� 7I08,SINHdM90N$.CF THE �1 NEW Y=STATE E%rAYIOt LAW.' S t e v e S aBrms Eoo moavrm OUKMVS sNaer tAllA®WIIIIAY g1BOBYLaPnetAlfD BUIBRYONB ��� ,��Y�, Timothy S. & osaria Smith S- 1 .a I„DNB�YED IDIEDY�Y THAT na DOSING C w PRWRCD N AODOID1WCf MYN 71! Land Surveyors BY �DE M STATE A SON LAM BI PMESMIAMS ADDP,E° BY THE NEW YDSK STATE AS90gATNN OF PROFE9510NAL LAND StR1-f=SAD CWTIRGAYNNS SNAIL"OB.Y TO THE ARSDN Fat*M THE"W-f tS PREPARED,AND W WS BMW TO THE TIRE cMMr .000EANMITAL SHWT 1 OF 169 Haviland Road Queensbury, New York 12804 M,,LEaOI L: W AW Town of Queensbury, Warren County, New York 0 616105 SEPTIC SYSTEM AS—BUILT MICHAELS GROUP 518 792-8474 New York Lic. No. 50135 NO. DA 7E DESCRIPTION DWG. No. 02333-10 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: NAME: LOCATION: c PERMIT#: 4- Final Survey Plot Plan Approved Denied The attached final survey has been received by the / Dept. of Community Development. Upon review t e survey has be n: )CraigYZoning Administrator Notes: L:\.SueHemingway\Building.Codes.lnspection.FORMS\Final Survey Zoning Administrator.doc MAP REFERENCE: --QUINCY LANE SUBDIVISION THE MICHALES GROUP BY: VAN DUSEN & STEVES DATED: APRIL 15, 2003 LAST REVISED: JUNE 10, 2003 �I NC z 410 LOT 9 o F n 1 LOT 11 ss D°O z D (P W � LOT 10 2.74 acres 119,462 sq.ft. \ ca( 510, 14, \� M N�3`�3 Nw h�� W C. c �ooi ► I.A t Date, MAY 4, 2005 a� D u ,S' 'UN4U7N BEARING A L&MATION aR ADOITIR S A SURVEY Map of a Survey made for Scale 1'=40' NAP TIONOF ACTION 7D LAND SURVEYORS SEAL IS A &�w VIOLATION OF SECTION 720Y.SUB—gN90N 2 OF THE NEW Yqo(STATE EDUCATION LAB.' S ONLY COPIES OPJ THE ORIGHE L N TN15 SURVEY MARKED WITN AN OR)GINAL of THE LAND SURVEYORS � � ��VALA» TNTHECOPIM Timothy S . & oksana Smith cmT1�ICATIONS INDICATED HEREON SIGWY 1HAr THIS E)GSTINQ O v OF PREPARED w ACCORDANCE wR AD Land Survey ors LAND S DDDE OF SAIPRAD FOR LA� ADOPTED SHM 10F 1 OY THE I"YORN STATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS.SND CERTIFICATIONS SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED.AND ON HIS BEHALF TO THE TITLE COMPANY.GOVERNMENTAL 169 Haviland Road Queensbury, New York 12804 "�" LEN DING fN511T77ON IMM HEREON,AND Town of Queensbury, warren County, New York iON'TO 111E A551GHEE5 Of THE LENDING M5TITUT MICHAELS GROUP (518) 792-8474 New York Lie. No. 50135 NO. DATE DESCRIPTION DWG. NO. 02333-10 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/ epart: /pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT �#: LOCATION: t INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates PluMbing Vent/ Vents in Place 1 ­l 2 inch minimum Drain Size Washing Machine Drain 2 inch minimum C anout every.100 feet/ change of direction Aessure Test Drain / YRfK, � La—UC—Z Ai; .I '10 ead 5 _ft. above highest connection for 15 minutes Presso Test er Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\lnspection Forms\Rougb Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,200 Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: �S Queensbury Building&Code Enforcement Arrive: am/ m ,,P e/part: pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: I3� C NAME: (-r)►CA n e j 6-0(> PERMIT NO.: LOCATION: y; rwQ INSPECT ON: 0, RECHECK: )f Comments and/or diagram Soil Type: a lay Type of Wat r unicip /Well Water Waterline separ istance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution BZw w Distribution Box to i /Pit �l �� �� �15Y—'0 Opening Sealed. / Partial / End Caps Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits Conforms as per Plot Plan Y N Engineer Report and As-Built Y N Location of Syste on Property: Front Rea Left Side Right Side Middle Front Middle Rear System Use Status: pproved artial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved Last revised 1/6/05 R r s� e,. 0 jp CEI NOV e1 0 2004 IOWBU LDING AND CODE Y Septic Inspection Report Office No. (518) 761-8256 Date Inspection request received: f, Queensbury Building&Code Enforcement Arrive: a De art am: ' /pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials NAME: PERMIT NO.: I V LOCATION: INSPECT ON: 7 RECHECK: Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank To to Distribution Box istribution Box to Field/Pit Opening Sealed: Y/N/Partial Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan Y N Location of System on Property: Front Rear Left Side Right Side Middle/FronMiddle Rear S stem Use Sta Approved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved L:\SueHemingway\Building.Codes.Inspection.FORMS\Septic Inspection Report.doc January 28,2003 Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p epart: m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: Vk�C KA-6 'f-2 PERMIT NO.: © �� LOCATION: L)tAtC' L INSPECT ON: 05, RECHECK: Comments and/or diagram Soil Type: Sand/Loam/Clay Type of Water: Municipal/Well Water Waterline separation distance ft. Well separation distance ft. Other wells: Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Buil ' g to tank T to Distribution Bo istribution Box to F' /Pit Opening Sealed: Y N/Partial End Cap3 U d Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan _Y N Engineer Report and As-Built Y N Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status: A roved artial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved Last revised 1/6/05 Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: ' Queensbury Building& Code Enforcement Arrive: am/ ep am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: Mpc—a: PERMIT #: 4 " LOCATION: v toG� INSPECT ON: 06— it - 11 TYPE OF STRUCTURE: Y . N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rou Plumbin /Nail Plates 1 % inch min.Drain Size Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents 5 PSI or. 10 feet above highest connection for 15 minutes Cleanout every 100 feet-/chan a of direction Water Supply Piping ooper Commercial Cooper,CPVC,Pex One and Two-Family kK. Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/p : Depart: am%pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: . lG�(�✓�i15 PERMIT #: d �9 LOCATION: INSPECT ON: TYPE OF STRUCTURE: i .� Rough Plumbing / Nail Plates Plumbing Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ Head _ ��,` for 15 minutes Insulation / sidential Check / Commercial Check ro er ent Attic Vent �r'5C'(J 5s�� Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape LAPam Whiting\Building&Codes\lnspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing Firestopping/ Firest in i �Inspection Report Office No. (518) 761-8256 Date Inspection req est received Queensbury Building& Code Enforcement Arrive: arr am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:W7 NAME: N ( PERMIT#: (0 L LOCATION: AAA INSPECT ON: _ / TYPE OF STRUCTURE: Y N/A rig COMMENT' Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. otches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade � P _ r� 3 s c,11J,tJ . L:\SucHemin-way\Building.Codes.lnspection ORMS\Framing Firestopping Inspection RepLrt.doc January 28,2003 -T:>ti�C�c VC�/� L % ��4 L /Of . C>� "( Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pru ,, Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials r�t � NAME: iC---'71rcLu� PERMIT #: LOCATION: INSPECT ON: a TYPE OF STRUCTURE: Y N N/A j Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet / change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/ blead 1 5 .S.I for 15 minutes 1 sulation / Residential Check/ Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape 112 L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 2 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: f Queensbury Building &Code Enforcement Arrive: am/ Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUC E: Comments Y N N/A j Footings )I Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/ Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval umbing Under Slab PV Cast/Copper G v Y4zAdation Insulation Interior/txteiior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.Inspee tion.FORIVI S\ro Uspection Repot t.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/p : am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: LOCATION: 31 ( �, Z_r INSPECT ON: — TYPE OF STRUCTURE: 4' N/A Plumbin / Nail Plates `—Pkjmb!`66 Vent / Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum leanout every 100 feet/ change of direction f„Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes �,r s"ure Test Water Supply Piping Air/ Head 50 P.S.I for 15 minutes Insulation / Residential Check/ Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Report L�fw ,-V,� Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: ai e art: am/pm �✓ 742 Bay Road, Queensbury, NY 12804 Inspector's Initials _ O - � NAME: i PERMIT#: LOCATION: INSPECT ON: TYPE OF STRU Y N /A C®MMEl®1'I' __ �aming S �r Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate / i,,./e 1 % (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor'trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour P/�a��%� A-rr Fire wall 2, 3, 4 hour -F' stopping - _ Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASueHemingway\Building.Codes.Inspection.FORM S\Framing Firestopping Inspection Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/ � art: i • am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: ��1� G-� PERMIT#: 4, 3 LOCATION: u l Kkg L INSPECT ON: O TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses ,Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation j, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 518 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: _a pm Depart:' L am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials. NAME: PERMIT#: 0 LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMIETS Framing Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge (8) 16D nails each side n �" Draft stopping 1,000 sq. ft. floor trusses Anc r Bolts 6 ft. or less on center ����® e and snow shield 24 inches from wall Fire separation 1, 2, 3 hour ()0 F 1 Ip Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. AJ Y_ Garage Fire Separation House side % inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection re est e eiv d: _ Queensbury Building&Code Enforcement Arrive: a Depart: a pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initia : _ NAME: _FA l --HP1E U PERMIT#: Z-,`)Oy 9 LOCATION: __ �� _ �U\ ►JCJ— INSPECT ON:TYPE OF OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this pu.T se on site._ Foundation/Wallpour Reinforcement in Place Foundation Dampproofing oundation/Waterproofing Type of Dampproofing Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing /L 6 mil poly for wet areas under slab ackfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASucAcmingway\Building.Codes.InspectionTORMS\I'oundation Inspection Report.doe January 28,2003 Foundation Inspection Report Office No. (51 8) 761-8256 Date Inspection request rece'ved: 2 �c S Queensbury Building &Code Enforcement Arrive: am/p Depart. m/pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT#: L ICI _ LOCATION: INSPECT ON: S TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foun"*'Fciat"�i0 L7arn roofin Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil pqly for wet areas under slab Backfi l A�pro al Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. l.:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 1 Foundation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/p epart: pm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initials. NAME: PERMIT PERMIT#: LOCATION: 16 INSPECT ON: TYPE OF STRUCTURE: Comments ^� Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. erials for this purpose on site. oundae6i n/Wall.pour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- _ Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc Januajy 28,2003 Foundation Inspection Report LL i Office No. (518) 761-8256 Date Inspection requ st received: CI T v Queensbury Building&Code Enforcement Arrive: am/ De rt: anvpm 742 Bay Rd., Queensbury, NY 12804 Inspector's Initial _ NAME: , l GI e� PERMIT#: �( `� �> LOCATION: �� l I 'A INSPECT ON: / DJ TYPE OF STRUCTURE: �� Comm nts _-=- Y N N/A Footings ' Piers Monolithic Slab Reinforcement in Place L� The contractor is responsible lore / providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.InspectionTORMSToundation Inspection Report.doc January 28,2003 F a 0Lf _ 3 Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code RES checkSoftware Version 3.5 Release lc Data filename:F:\SHARE\Design\Energy Calc\Quincy Lane\32 Quincy.rck TIME:Spruce U eo0 2004 TOWN OF QUEENSEURY COUNTY:Warren EUILDING AND CODE STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE: 11/16/04 DATE OF PLANS:November 15,2004 PROJECT INFORMATION: 32 Quincy Lane Queensbury,NY _., COMPANY INFORMATION: The Michaels Group ' 10 Blacksmith Dr. Malta,NY 12020 NOTES: Pella Proline Windows ';:F`�''"t' High Efficiency Gas Furnace(92%) w . N. COMPLIANCE:Passes Maximum UA=520 Your Home UA=420 19.2%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Raised or Energy Truss 1422 30.0 0.0 46 1st fl walls:Wood Frame, 16"o.c. `1534 19.0 0.0 75 lx Mbr(BC):Wood Frame:Double Pane with Low-E 31 0.340 11 lx Bed#2(AD):Wood Frame:Double Pane with Low-E 28 0.340 10 Living#17: Glass 54 0.350 19 lx Living(D):Wood Frame:Double Pane with Low-E 14 0.340 5 lx Dining(BC):Wood Frame:Double Pane with Low-E 31 0.340 11 2x Dining(AR):Wood Frame:Double Pane with Low-E .21 0.340 7 lx Brkfst(AD):Wood Frame:Double Pane with Low-E 28 0.340 10 2x Brkfst(AR):Wood Frame:Double Pane with Low-E 21 .0.340 7 Ix Master Bath(DL):Wood Frame:Double Pane with Low-E._ 10 0.340 3 Foyer#1A:Solid 29 0.350 10 Laundry#20:Solid 19 0.240 5 v 2nd floor walls:Wood Frame, 16"o.c. 1064 19.0 0.0 59 1x Foyer 3553 Arch:Wood Frame:Double Pane with Low-E 8 0.340 3 1x opt Bed#3(AZ):Wood Frame:Double Pane with Low-E 18 0.340 6 2x Loft(AR):Wood Frame:Double Pane with Low-E 21 0.340 7 lx Loft(BC):Wood Frame:Double Pane with Low-E 31 0.340 11 Basement Wall 1:Solid Concrete or Masonry 789 0.0 11.0 46 Wall height:7.6' Depth below grade: 6.6' Insulation depth: 6.0' Ix Std Bsmt Win:Wood Frame,Double Pane with Low-E 2 0.520 1 23359 Windows @ Walkout: Wood Frame:Double Pane with Low-E 27 0.340 9 6068 Slider @ Walkout: Glass 40 0.350 14 2868 @ Bsmt Stair to Garage:Solid 19 0.240' S Basement Wall @ Walkout:Solid Concrete or Masonry 506 0.0 11.0 40 Wall height:7.6' Depth below grade:0.0' Insulation depth:7.6' Furnace 1:Forced Hot Air,92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they ar ttesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in co lianc this Code. Date Builder/Designer �� �✓� DP' ,i REScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release Ic DATE: 11/16/04 TITLE:Spruce Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. Above-Grade Walls: [ ] 1. 1st fl walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 2. 2nd floor walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 1: Solid Concrete or Masonry,7.6' ht/6.6' bg/6.0' insul, R-11.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. [ ] 2. Basement Wall @ Walkout:Solid Concrete or Masonry,7.6' ht/0.0'bg/7.6' insul, R-11.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6-in.below grade. Windows: [ ] 1. Ix Mbr(BC):Wood Frame:Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 2. lx Bed#2(AD):Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 3. Ix Living(D):Wood Frame:Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 4. lx Dining(BC):Wood Frame:Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 5. 2x Dining(AR):Wood Frame:Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 6. Ix Brkfst(AD):Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 7. 2x Brkfst(AR):Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes . Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 8. lx Master Bath(DL):Wood Frame:Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 9. lx Foyer 3553 Arch:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 10. lx opt Bed#3(AZ):Wood Frame:Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 11. 2x Loft(AR):Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 12. lx Loft(BC):Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 13. lx Std Bsmt Win:Wood Frame,Double Pane with Low-E,U-factor:0.520 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 14. 23359 Windows @ Walkout:Wood Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: Doors: [ ] 1. Living#17: Glass,U-factor:0.350 Comments: [ ] 2. Foyer#lA:Solid,U-factor:0.350 Comments: [ ] 3. Laundry#20:Solid,U-factor:0.240 Comments: [ ] 4. 6068 Slider @ Walkout: Glass,U-factor:0.350 Comments: [ ] 5. 2868 @ Bsmt Stair to Garage:Solid,U-factor:0.240 Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air,92 AFUE or higher Make and Model Number Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. . [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [ ] All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: -[ ] -Fireplaces must be installed with tight-fitting non-combustible fireplace doors. -- [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State ,the Residential Code of New York State or the New York City Building Code ,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ J HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) 2"Runouts l"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)