building specficiations \\ UIGOFt 2020 Residential Code of New York ��� COUf` State man First version:Nov 2019 SECTION R507 EXTERIOR DECKS TABLE R507.9.1.3(1) DECK LEDGER CONNECTION TO BAND JOISTa•6(Deck live load = 40 psf, deck dead load = 10 psf, snow load S 40 psf) GIST SPAN CONNECTION DETAILS 6' and 6'1"to 8'1"to 101"to 12'1"to 14'1-to 16'1-to less is 10' 12' 14' 16' 18' On-center spacing of fasteners ma inch diameter lag screw with llz-inch 30 23 18 15 13 11 10 maximum sheathing•d 1/2-inch diameter bolt with 1/2-inch maximum 36 36 34 29 24 21 19 sheathingd 1/2-inch diameter bolt with 1-inch maximum 36 36 29 24 21 18 16 sheathings CONNECTION DETAILSJOIST SPAN6'and less6'1"to B'8'l-to 10'10'1-to 12'12'1-to 14'14'1-to 16'16'1"to 18'On-center spacing of fasteners 1/2-inch diameter lag screw withl/2-inch maximum sheathing,d 302318151311101/2-inch diameter bolt with 1/2-inch maximum sheathings 363634292421191/2-inch diameter bolt with 1-inch maximum sheathinge 36362924211816 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa. a. Ledgers shall be flashed in accordance with Section R703.4 to prevent water from contacting the house band joist. b. Snow load shall not be assumed to act concurrently with live load. c. The tip of the lag screw shall fully extend beyond the inside face of the band joist. d. Sheathing shall be wood structural panel or solid sawn lumber. e. Sheathing shall be permitted to be wood structural panel, gypsum board, fiberboard, lumber or foam sheathing. Up to 1/2-inch thickness of stacked washers shall be permitted to substitute for up to 1/2 inch of allowable sheathing thickness where combined with wood structural panel or lumber sheathing. Copyright ® ICCAII Rights Reserved. Accessed by David Hatin on 06/14/2021 pursuant to License Agreement with ICC.No further reproduction or distribution authorized.Any Unauthorized reproduction or distribution is a violation of the federal copyright,and subject to civil and criminal penalties thereunder. �i DIGITAL 2020 Residential Code of New York ■ CODES State First Version:Nov 2019 SECTION R507 EXTERIOR DECKS i STAGGER FASTENERS N3 IN2ROW5 C C ® 53'MIN.FOR 2 X B' 'DISTANCE SNALL BE PERMITTED TO g BS MIN.FOR 1 X 10 BE REDUCED T04 S IF LAG SCREWS 0 0 T.Y MIN.FOR 2 X 12 ARE USED OR BOLT SPACING IS REDUCED TO TNAT OF LAG SCREWS TOATTACN 2 X II LEDGERS TD 2 X B i MIN BAND JOISTS. LEDGER LAG SCREW OR BOLT YY Mw, For 51:1 inch =25.4 Trim. FIGURE R507.9.1.3(1) PLACEMENT OF LAG SCREWS AND BOLTS IN LEDGERS Copyright ® ICC All Rights Reserved. Accessed by David Hatin on 06/14/2021 pursuant to License Agreement with ICC.No further reproduction or distribution authorized.Any Unauthorized reproduction or distribution is a violation of the federal copyright and subject to civil and criminal penalties thereunder. \\ 1::L 2020 Residential Code of New York AIRW J'f State low First Version:Nov 2019 SECTION R507 EXTERIOR DECKS R507.2.4 Flashing. Flashing shall be corrosion-resistant metal of nominal thickness not less than 0.019 inch (0.48 mm) oapproved nonmetallic material that is compatible with the substrate of the structure and the decking materials. Copyright ® ICC All Rights Reserved. Accessed by David Hatin on 06/752021 pursuant to License Agreement with ICC.No further reproduction or distribution authorized.Any Unauthorized reproduction or distribution is a violation of the federal copyright and subject to civil and criminal penalties thereunder. Paul Ritz 10209 Brooks Rd r West=ville,NY 13496 315-369-9701 FIELD REPORT CUSTOMER- JOB STIE: S eve W;nne>' 23 Kimbdrky lane PROJECT: QuE [1� hufV N.Y, Dec K 5 Hur a. a. 3. m Sump for iechna Metal port r.tW veatiral comprenlon bed anry.Not fespoatlhk for the con,t c of the iechno Metal pasts to the sttmmm Head Used 160 LOAD CAPACMES p POST DEPTH SINK PSI CAPACTY 1 t 1000 21160 2 0 00o1 2760 3 PZ 5 O SO 22 �0 4 P2 51 O 1050 3290 5 s O 1000 2760 6 7 8 9 10 11 12 13 14 15 lnsw;m Sigrmwm:_ lJ. i O