Drawings R GRAPHIC SCALE THE FOLLOWING TEST PITS WERE OBSERVED BY ENVIRONMENTAL _ cw y DESIGN PARTNERSHIP, LLP ON APRIL 13, 2021. 2- WEATHER: 507, SUNNY 80 160 320 ;:�i�, �0 60 40 20 A (IN FEET) TP�1 x 1 INCH = 80 FT. 0" - 12" TOPSOIL, ORGANIC MATERIAL SOME ROOTS €�a1�_r,:k��ar�� 12" - 24" BROWN MEDIUM SAND Z 24" - 66" LIGHT BROWN/GRAY MEDIUM SAND WITH SOME ROCKS MAP REFERENCES: 1) Map Entitled: 'MAP OF A SURVEY MADE FOR JOAN MCGRATH" NO SEASONAL HIGH GROUNDWATER OBSERVED i Z vN SITE LOCATION Map Date: November 8, 2006 TP2 d ° Prepared By. VAN DUSEN & STEVES LAND SURVEYORS _ 0" - 18" TOPSOIL, ORGANIC MATERIAL :3 18" - 24" BROWN MEDIUM SAND 24" - 72" LIGHT BROWN/GRAY MEDIUM SAND N/f O OF m LANDS t�r 67EVEN5 HARD PAN/POSSIBLE MOTTLING AT 60" N o f, + O PT#,~1 O N cU STABILIZED RATE AT 5 MINUTES 15 SECONDS o N N N J C3 CORNER STTE L*�CATION MAP PT2 FOR STABILIZED RATE AT 9 MINUTES 24 SECONDS I�1 o o d a LE SCALE: 1" = 2000` S07°44'34"W Z Q 1031.48' GIPS N o N w Q m 3 NOTE: cC LU U) _ NO NEIGHBORING WELLS c { WITHIN 100' OF PROPOSED t9 LL_ z f- WASTEWATER ABSORPTION FIELD CIR Q UJ Z Cw G z z 0 Lu z Am m W — X ^77 —� v J� �'^7 W W ALO EXISTING FIELDS o SEPTIC TANK, LEACH A l o N FIELD TO BE REPLACED /�1�0^\ s t � "a`���~�°° i tw� 2 3 03 es JE��a Z I-- 07 ? kn o �M U) LL .. 00 C,Q in tst.zs• \ � � � M F-� � / °wo L ® SIRS REVISION DATE BY d � L 0 ALO EXISTING WELL �72 p Re By. SB 2 00 1.001 — o M 1 v = i IRf sa.13' IP z IP 241.81' IP IPP SCALE: _ 1"=80' N08°37'48"E IP N08'01'30°E N07®59'00" 2 .1 \ 2 SHEET TITLE: � m ��! EXISTING z W PP 290.10-1-7 SEP-0579-2021 CONDITIONS D McGrath, Joan Li z 38 Hiland Dr SHEET NO. S_1 Residential Septic Alterations 3 C3 WASTEWATER SYSTEM — BASIS OF DESIGN GRAPHIC SCALE REGULATORY AUTHORITY. TOWN OF QUEENSBURY g--- DESIGN STANDARDS: NEW YORK STATE DEPARTMENT OF HEALTH (10NYCRR APPENDIX 75—A), WASTEWATER TREATMENT STANDARDS — INDIVIDUAL HOUSEHOLD SYSTEM. TOWN OF 6?W ,. t QUEENSBURY WASTEWATER ORDINANCE 1979. 1 _ " PROJECT DESCRIPTION: THE EXISPMG WASTEWATER SYSTEM CONSISTS OF A 1,000 GAL. CONCRETE SEPTIC TANK DISCHARGING TO AN APPARENT LEACH FIELD. GIVEN ITS � 40 30 20 10 0 40 80 160 PROBABLE AGE (40+ YEARS) AND CURRENT OPERAT70NSAL ISSUE' IT IS PROPSED TO INSTALL A REPLACEMENT SYSTEM. IT IS PROPOSED TO HAVE THE BUILDING SEWER FLOW TO (IN FEET) THE SEPTIC TANK BY GRAVITY, ONCE ALL SOLIDS ARE SETTLED, THE EFFLUENT TO FLOW BY GRAVITY TO A DISTRIBUTION BOX, THEN DISTRIBUTE AMONGST THE LATERALS IN THE J s ti PROPOSED SHALLOW ABSORPTION TRENCHES. ANY REMNANTS OF THE EXISTING SYSTEM WILL BE REMOVED AND REPLACED WITH SUITABLE SAND BASED SO/L(PERC RATE 6-7 1 INCH = 40 FT. MINUTES/INCH). WATER SUPPLY., WELL LOCATED GREATER THAN 10OFT OF PROPOSED FIELD. PROJECTED FLOWRATE.• BASED ON A FIVE (5) BEDROOM COUNT AND NYS DOH STANDARDS FOR POST 1991 WATER SAVING FIXTURES ® 110 GALLONS PER DAY PER BEDROOM, THE AVERAGE DAILY FLOW (ADF) IS 550 GALLONS. SHOULD HOUSEHOLD FIXTURES NOT BE OF THE 'LOW FLOW' TYPE MANUFACTURED SINCE 1991 THEN THE FIXTURES SHALL BE d w REPLACED AS NEEDED. THIS FLOWRATE DOES NOT INCLUDE THE USE OF A GARBAGE GRINDER (NOR IS ONE RECOMMENDED) OR A HOT TUB/SPA. ADDIT70NAL FLOWRATE MUST BE INCLUDED IN THE DESIGN SHOULD EITHER OF THESE COMPONENTS BE PART OF THE HOUSE DESIGN. _ SEPTIC TANK: DESIGN CAPACITY— 1,500 GALLON (MINIMUM). A 1,500 GALLON SEPTIC TANK IS PROPOSED FOR THE EXISTING RESIDENCES. f ABSORPTION FIELD SYSTEM: THE ABSORPTION SYSTEM IS DESIGNED AS A DISPERSAL SYSTEM WITH SIX (6) LATERALS AT 55 LF, TOTAL ABSORPTION AREA EQUAL TO 640 SF rr ' N cU J J N NOTE -11 o 1� N `� EMBANKMENT TO BE PER Z`,- o PRECAST CONCRETE OWNER; STABILIZED SLOPE ¢ N — - DIS RIBUTION BOX, TO EXISTING GRADE, ORLL REFER TO DETAIL RETAINING WALL JJ . �y r — < s 4" PVC SD —35 EFFLUENT a F PIPE AT J" FT MIN SLOPE SILT FENCE, TYP '�-- .� � Lu rn J Aoft 3 Li Lu j '��'� ►� SHALLOW ABSORPTION FIELD, I` 1 6 LATERALS AT 55' EACH z 1,500 GALLON �{ \ \Cj\\\\ °� C H CONCRETE SEPTIC O} v TANK \\\\\\ \ Ln \\\\�\\\\\\\\`\ N 4" PVC SDR-35 PIPE AT J"/FT MIN SLOPE J \ \\�\\ ^ f I \ f \\\JJJ t �� \ Q a co z U) } ° IlIZ �- a U) ♦♦ Q Ill l7 } Q � OQ a REVISION DATE BY a 1 0,0 ` 1 GARAGE t o � 00 SCALE: JJ68. 13' ' 1F fi r' 241 81 WASTEWATER ABSORPTION TRENCH DESIGN CAL CUL AL TIONS: 1 ��=40' 1 THE PROPOSED ABSORPTION FIELD WAS DESIGNED IN ACCORDANCE WITH } N08°37'48"E I ! ° NYSDOH APPENDIX 75A AS FOLLOWS SHEET TITLE: i ��"�---- N08 01 30 E WASTEWATER C�/�/ C p DESIGN PERCOLATION RATE = 8-10 MIN/IN v y ASTE V V ATE R Z { 4 z TOTAL BEDROOM COUNT= 5 W O DESIGN FLOW = 110/GAL/DAY/BR PLAN =110 X 5 = 550 GAL/DAY c�3 APPLICATION RATE = 0.90 GAL/DAY/SF Z j y REQUIRED ABSORPTION AREA = 55010.90 = 611 SF W REQUIRED FIELD LENGTH= 511/2= 305.5 FT SHEET NO. \\ O O USE 6 LATERALS AT 55' EACH c PROPOSED FIELD LENGTH 6X55 = 330 FT V—2 3 m C3 j E GENERAL SANITARY NOTES: PLASTIC FRAME AND BY 1. MINIMUM SEPARATION BETWEEN SEPTIC TANK AND BUILDINGS SHALL BE 10 FEET. Flxlsxm GRADE coVm - OR EQUAL za'-}t _ Y a 25'_#2 II r ACCESS EXTENSION(MH 0 V 2. MINIMUM SEPARATION BETWEEN EDGE OF TRENCHES AND TOE OF FILL (RAISED SYSTEMS) 4•OUTLETS 1 FINISHED GRADE SEAL - GRADE RINGS)z'I.D. '-,Z, }y r 3 IN. BY POLttDX OR EQUAL �` 1 1 AND BUILDINGS SHALL BE 20 FEET. — I I�A• T ` N REMOVABLE COVER 4•BIDG.SEWEt— m I I —� _ 3. MINIMUM SEPARATION BETWEEN PROPERTY LINE AND EDGE OF TRENCHES OR TOE OF FILL - (RAISED SYSTEMS) SHALL BE 10 FEET. �— iFE ojl _ W w "ODE OUT 1 INLET as INLET BAFFLE I 4.OUTIEf j 1 sA18TARY TEE W/ MIN. _ FULL BIN4 1 1 4'MIN. EFFLUENT FTLTFR 4. MINIMUM SEPARATION BETWEEN WELL AND SEPTIC TANK TO BE 50 FEET. ' g"MIN. COT �� BAFFLE WITH j I fop �� '`� KOP 300M OR ?1 1 8'X18'ItlN. "' Ow Nor s 5. ALL CONSTRUCTION TO BE IN COMPLIANCE WITH THE NEW YORK STATE SANITARY CODE. z lm ALL a0N BELOW MID 6•TO 12'LAYER PEA Z TO BE WATiRTKitf GRAVEL OR CRUSHED .. AND LEAKAGE TESTED PRIOR SECTION VIEW STONE BEDDING LAYER ,�N TO BACIo-Nl.INc 6. REQUIRED INSPECTIONS (TO BE PERFORMED BY PROFESSIONAL .gt"PFA aNVE.Ll ti. `� NOTE: ENGINEER): ... HOPE PIPE SEAlB 1TTP) INLET INVERT IS Y ABOVE(2-MIN) �r 3, 4.OUTLETS HOPE PIPE SEALS(TYP ASPHALTIC SEAL A) PRIOR TO PLACEMENT OF SEPTIC TANK OR COMMENCEMENT OF NEW PLAN VFW THE TILE FIELD CONSTRUCTION. 1. Dwx TO BE/a DIslRIeunq+Box BY FiMf MILLER OR EQLW "LET i QUy 2. INVERT ELEVATIONS OF ALL OUTLET PIPES MUST BE EZAL- USE OF SPEED �v, LEVELING DEVICES IS REQUIRED. T B) DURING THE INSTALLATION OF ANY REQUIRED FILL MATERIAL. a THE SLOPE of OUTLET PIPES BLIWEIIH THE oRTRO TION Box AM ~ t115fR03lffOR LITERALS SHOULD AT LEISf 1/32'PER FOOT. THE SLOPE OF iF@ INLET PIPE I BAFFLE A= NOT REQUIRED FOR TANKS r 0 4. DISTRIBUTOR 45 REQUIRED. BETWEEN 111E�EHTIAL UNIT LESS THAN 10 FT.LENGTH AND THE SEPTIC TANK TO BE}' D Q CV < C) PRIOR TO BACKFILLING TRENCHES. 5, D-BOX TO BE SET ON 12•MIN.COMPACTED CRUSHER RUN(REM 04)OR PER FOOT ¢ ' pry PEA GRAVEL PLAN VIEW O N N D) FINAL INSPECTION UPON COMPLETION OF THE SYSTEM. ®I TRIBV 1 ON BOX TANK SIg 41N LIQUID DEPTH'A•TANK gMEH510NS•B XC 0 9' aT O v F t N J M 1500 GAL 4'-1• 8'-0'X 11'-0• 4'-1 5'-1• 5'-3' N O 7. CRUSHED STONE SHALL BE CLEAN, DURABLE AND NO SMALLER THAN OR LARGER THAN 1-1/2" DIAMETER. VEITTO SCALE LL 8. WHEN THE TRENCHES HAVE BEEN EXCAVATED, THE SIDES AND BOTTOM SHALL BE RAKED TO SCARIFY 1 500 GALLON SEPTIC TANK O Z a N NY SMEARED SOIL SURFACES. 8•MIN tU NOT TO SCALE TOPSOIL ki Q O 9. CONSTRUCTION EQUIPMENT NOT NEEDED TO CONSTRUCT THE SYSTEM SHOULD BE KEPT OFF E AREA TO BE UTILIZED FOR THE 4'D.C. 12'MN 13ACKFlL � Z � ABSORPTION TRENCH SYSTEM TO PREVENT UNDESIRABLE126.70 COMPACTION OF THE SOILS. a•PERFORATED - FABRIC Ewsnxc GRADE — WOVEN PROPOSED 10. EACH DISTRIBUTION LINE SHALL CONNECT INDIVIDUALLY TO THE DISTRIBUTION BOX AND EXIT T THE SAME SLOPE FOR THE FIRST &I SUSUOM GRAM ^ ^ `"'' " ~ To EXI80NG GRADE 124.00 I — uj FEET TO 10 FEET FROM THE BOX (1/8 PER FOOT). " O7 W 3 11. THE DISTRIBUTION BOX SHALL BE SET LEVEL AND ARRANGED SO THAT EFFLUENT IS EVENLY DISTRIBUTED TO EACH DISTRIBUTION LINE. EXISTM GRADE III— I I a 2 ADEQUATE PROVISIONS SHALL BE TAKEN TO ASSURE STABILITY AND PROVIDE ACCESS FOR INSPECTION OF THE DISTRIBUTION BOX. 12. THE PIPES CONNECTING THE DISTRIBUTION BOX TO THE DISTRIBUTION LINES SHALL BE TIGHT JOINT CONSTRUCTION LAID ON I-III—III—I —I j-I V UNDISTURBED EARTH OR PROPERLY BEDDED THROUGHOUT ITS LENGTH. —III—III—III III-I INATIVE I—III I I—_III—I _I ¢I III _ _ z 13. THE SYSTEM DESIGN DOES NOT INCLUDE PROVISIONS FOR GARBAGE GRINDERS. IN THE EVENT THAT GARBAGE GRINDERS ARE TO BE I I III_ I —III I "' 1z'THICK WASHED I I I J INSTALLED, THE CONTRACTOR SHALL NOTIFY ENGINEER PRIOR TO SEPTIC INSTALLATION FOR N CESSARY MODIFICATIONS. —I —I ( TO S.� z'MIN vER.sEPORAROCK GROUNDWATER O- W 14. FOOTING DRAINS, SUMP PUMPS OR WATER SOFTENER DISCHARGES SHALL NOT BE CONNECTS LI INTO THE SEPTIC SYSTEM. I I F'm'POLYPRLL IS L.1.xER WHEN WALL 6 C � PT�.SENr G Y j In 15. CONTRACTOR TO COMPLY WITH ALL O.S.H.A. AND OTHER STATE AND LOCAL SAFETY REQUIREMENTS DURING CONSTRUCTION. n/ O N 16. AS PER NEW YORK STATE INDUSTRIAL CODE 53: CALL 1-800-962-7962 TO LOCATE BURIED CABLES, OR OTHER UNDERGROUND �J•, UTILITIES, NO LESS THAN TWO, OR MORE THAN TEN WORKING DAYS, PRIOR TO DIGGING, DRILLING EXCAVATING, DRIVING POSTS, ETC. WASTEWATER SECTION w s NI]T T❑ SCALE S„ m Z Ln WZI_ °- CONSTRUCTION NOTES: W Lij Z 1) CONSTRUCTION OF ABSORPTION FACILITIES SHALL NOT OCCUR WHEN THE GROUND IS FRO EN OR THE SOIL MOISTURE CONTENT IS HIGH. IF A FRAGMENT OF SOIL FROM TiRRATE(No.2 NONWOVEN I— 0 O N APPROXIMATELY NINE INCHES BELOW THE SURFACE CAN EASILY BE ROLLED INTO A RIBBON INSTEAD OF CRUMBLING, THE MOISTURE CONTENT IS TOO HIGH FOR CONSTRUCTION CREATED rwn PAS f PURPOSES. OBVIOUSLY, SOME SILT OR CLAY MUST BE PRESENT FOR A RIBBON TO BE FORMED. uNREA1m BUODBHG PAPER Z O 0 LL Z / 0R smAw !\ W/ IMPORTED SAND Mk Flu.EQUAL TO MAX SEE SORE v J Z Ll Q 2) TRENCH LOCATIONS AND DEPTHS SHOULD BE MARKED BY STAKES BEFORE TRENCHES ARE EXCAVATED. THE NATURAL SURFACE SHALL NOT BE SIGNIFICANTLY DISTURBED. IF THE OR LESS THAN PER0gAn0N RAZE of 24' AT s:1 NATIVE MATERIAL PLACE IN 0'MAIL 6'MIN. SITE IS REGRADED OR SIMILARLY DISTURBED, THE SOIL SHALL BE ALLOWED TO STABILIZE (I.E., SETTLE NATURALLY FOR A PERIOD OF AT LEAST SIX MONTHS, INCLUDING AT LEAST ONE LFTS WITH MECHANICAL COMPACTION 12'MAXLh FREEZE-THAW CYCLE) AND NEW PERCOLATION AND DEEP HOLE TESTS CONDUCTED. HEAVYEQUIPMENT USE IN THE DESIGNATED ABSORPTION SYSTEM AREA SHOULD BE MINIMIZED TO vA TRACK TYPE MACHINES coQ PREVENT SOIL PERMEABILITY REDUCTION DUE TO COMPACTION PLUS POSSIBLE TRENCH C VE-IN AND DISTRIBUTION PIPE MISALIGNMENT/BREAKAGE. - DOS NG GRADE ~ S 3) AFTER A FINAL GRADE CHECK, TRENCH EXCAVATION MAY BEGIN. TRENCH DEPTH SHALL BE AS SHALLOW AS POSSIBLE, BUT NOT LESS THAN 18 INCHES. TRENCHES SHALL BE / REVISION DATE BY C5 EXCAVATED TO DESIGN DEPTH WITH BOTTOMS PRACTICALLY LEVEL. l7 U 4) FOLLOWING EXCAVATION, THE TRENCH BOTTOMS SHOULD BE GRADED BY HAND. THE BOTTOMS OF THE TRENCHES SHOULD BE CHECKED BY A TRANSIT, ENGINEERS LEVEL, OR r� I TTTfF CARPENTERS LEVEL TO ASSURE THAT EACH IS PRACTICALLY LEVEL. TRENCH BOTTOMS kND SIDEWALLS SHOULD BE IMMEDIATELY RAKED AFTER FINAL GRADING AND AT LEAST SIX I INCHES OF AGGREGATE PLACED IN THE TRENCHES. C1EAN WASHED 6'-12'INTO EXISTING SOIL00 GRAVEL ll•-11' dsntouTnN PIPE SLOPED 5) AFTER THE UPPER AGGREGATE IS PLACED IN THE TRENCHES, THE GEOTEXTILE, UNTREATED BUILDING PAPER, HAY OR STRAW IS TO BE IMMEDIATELY INSTALLED ON THE AGGREGATE AT III TO INCH F131 F00T LL AND THE TRENCH BACKFILLED WITH EXCAVATED SOIL. IF THE TRENCHES CANNOT BE IMMEDIATELY BACKFILLED, THE TRENCHES SHOULD BE TEMPORARILY COVERED WITH AN / IMPERVIOUSuYFn�RO"Dal��• I� IMPERVIOUS MATERIAL, SUCH AS TREATED BUILDING PAPER TO PREVENT SIDEWALL COLLAPSE AND SILTATION INTO THE AGGREGATE. SCALE: 6) THE EARTH BACKFILL IS TO BE MOUNDED SLIGHTLY ABOVE THE ORIGINAL GROUND LEVEL(I.E.. NOT COMPACTED) TO ALLOW FOR SETTLING. FOLLOWING SETTLEMENT, THE ENTIRE AREA SHOULD BE GRADED WITHOUT THE USE OF �EAVY EQUIPMENT AND SEEDED WITH GRASS. HEAVY EQUIPMENT SHALL NOT ENTER THE ABSORPTION FACILITY AREA OR THE PROPOSED AS S H®W N EXPANSION AREA AFTER THE SUBSURFACE SEWAGE TREATMENT SYSTEM HAS BEEN CONSTRUCTED. AM��SHALL E THE SATE 1 FOR �HHo+aHES EXCEPT CONSTRUCTION THE SUON SHALL BE THEY 0 E 12 OR CO DEEP N ORMULABSORPTION TIONUTRE } 7) A MINIMUM HORIZONTAL SEPARATION OF 10 FEET SHOULD EXIST BETWEEN THE HOUSE SEWER AND ANY WATERLINE. WHERE LINES MUST CROSS, THE WATER SERVICE LINE SHALL BE SHEET TITLE: AT LEAST 12 INCHES ABOVE THE HOUSE SEWER. IF A WATER LINE MUST PASS BELOW E HOUSE SEWER, THE VERTICAL SEPARATION MUST BE AT LEAST 18 INCHES. 8) ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED OM THE SYSTEM. WATER SOFTENER, WATER RECHARGE AND BACKWASH WASTES NORMALLY SHALL OW ABSORPTION TRENCH SECTION WASEWATER Ld z ARE NOT TO BE DISCHARGED TO THE SYSTEM UNLESS A SEPARATE SUBSURFACE DISCHARGE TO AN AREA 250 FEET FROM WELLS OR WATER COURSES IS UNAVAILABLE. NOT T❑ SCALE DETAILS Ld Z SHEET NO. S-3 3