Loading...
RC-0224-2021 Office Use Only ADDITION/ALTERATION PERMIT Permit#: — 6 -- Z0 APPLICATION Permit Fee: $ l .� Town of.Qe`arisbury 742 Bay Road,Queensbury,NY 12804 Invoice#: 3eQ Za1 P:518-761-8256 www.gueensbury.net Flood Zone? Y I� Reviewed By:' Project Location: 795 Bay Road, Queensbury NY Tax Map ID#: 289.15-1-32 Subdivision Name: n/a 4 + ge.A.L PROJECT INFORMATION: 'A41C*-L S76 ZPv9-7bzZ_' TYPE: X Residential Commercial, Proposed Use: X Single-Family _Two-Family _Multi-Family (#of units ) _Townhouse Business Office _Retail _ Industrial/Warehouse _Garage (#of cars_) Other (describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 668 sq/ft 2nd-floor: n/a 2nd floor: 3rd floor: 3rd floor: Basement (habitable space): Basement (habitable space): Total sq ft: Total.sq ft: 668 sq/ft Scope.of work to be done: Exterior: E E w/ New septic system '� -New siding &trim APR 9 4 2@21 -Remove&replace doors/windows -New asphalt roof shingles TOWN Oki QUEENSPURY -New spray foam insulation at walls&roof/ceiling BUILDING CODES -Remove inadequate ceiling joists&replace with structural collar ties Interior: -New Layout: Bedroom, Bathroom & Kitchen layout and related cabinets/fixtures -New Electric: 150 amp electric panel, all new wiring &devices. -New Plumbing: drains, supplies&fixtures -New heating/cooling: mini split system -Alteration: Existing garage area to be,.converted to a Family Room Addition/Alteration Application Revised January 2021 1 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $50,000 2. Source of Heat (circle one): _Gas _Oil _Propane _Solar X Other Fireplaces/inserts need a separate Fuel Burning Appliances &.Chimney Application 3. Are there any structures not shown on the plot plan? YES X NO Explain: 4. Are there any easements on the property? _YES X NO SITE INFORMATION: • Is this a corner lot? _YES X NO • Will the grade be changed as a result of the construction? YES X NO • What is the water source? X PUBLIC _PRIVATE WELL • What type of wastewater system is on the parcel? _SEWER X PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans, additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. If the work is.not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. 1 also understand that I/we are required to provide an as-built survey by a licensed_land surveyor of all newly 'constructed facilities prior to issuance of certificate of occupancy. I have read and agree to the above: PRINT NAME: Timothy Seelye SIGNATURE: 2 i� 5�� DATE: 4/14/21 Addition/Alteration Application Revised January 2021 i` CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Timothy Seelye Mailing Address, C/S/Z: 3994 Cape Haze Drive, Rotonda FL 33947 Cell Phone: 5( 18 ) 545-0941 Land Line: �) Email: timseeloverizon.net Primary Owner(s): Name(s): Timothy&Deborah Seelye Mailing Address, C/S/Z: 3994 Cape Haze Drive, Rotonda FL 33947 Cell Phone: ( 518 ) 545-0941 Land Line: Email: timseel@verizon.net 0 Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: Land Line: Email: **Workers' Comp documentation must be submitted with this application** • Arch itect(s)/Engi nee r(s): Business Name: Contact Name(s): Benjamin Nassivera Mailing Address, C/S/Z: 302 Washington Ave. Ext,Albany NY Cell Phone: 518 ) 265-7625 Land Line: Email: bnassivera@hcpdesign.com Contact Person for Compliance in regards to this project: Timothy Seelye Cell Phone: 518 ) 545-0941 Land Line: �) Email: timseel@verizon.net Addition/Alteration Application Revised January 2021 SEP-111C DISPOSAL PERMIT Office U!,,,e Only APPLICATION Permit W, Towri ofQ_wvnsbury Permit F-ae:$ Invoice 1": 74.1-Bay Road,Queensbury,NY I2E:04 P:518-761-8256 wvvvv,queensbu!21!-net Septic Variance? y N Flood Zcine? Y N Wklands? Y N Reviewed By;- Project Location: ^7l '137�-7 q I-v_c Tax-Map #: Zff). RESIDENCE INFORMATIONS Year Built Gallons V1 of bedrooms: X gallons pe'r =total daily flolw per day i bedroom Garbage Grinder Yes No 1980 or older 150 Installed? (choose one) _F] 1981-1991 130 Spa or Hot T& Yes No 1 19 91-Presenti iib I Installed? (choose one) E] PARCEL INFORMATIClijN. Topography D/Flat Rolling [] Steep Slope % Slope Soil Nature R/'Sand ❑ Loam 0 Clay ❑ Other, explain: Groundwater I At.what depth? Bedrock/Impervious material At What depth? Domestic Water Supply Municipal R Well OLake (if well or lake, water supply from any septic system,absorption is 'ft.) Percolation Test Rate:. per minute per inch (test to be completed by licensed engineer/architect) PROPOSED SYSTEM INFORMATION: Tank size PO O gall bris,(min. size 1,000 gallons, add 250 gallons for each gar.bagO cylinder Or spa/hot tuEb System Absorption field w/42 stone Total length 1�-6 ft.; •Each'Tronch ft. Seepage Pit w/#3 stone How many: _; 5ize: Alternativ,(;a System Bed or other type,: HQlding,T2'1nk System Total required capacity? tank size # of tanks Septic Application Revised April 2021 CONTACT INFORMATION: PLEASE PRINT LEG|BLYORTYPE, PLEASE INCLUDE AN EMAIL i Applicant: mame\o/' / ` —" ~'^-^~ LlMailing Address, C/S/Z: �-39qel Cell Phone: LandLine: � Mailing Address, C/S/Z: Cell Phone: nd Line: ErnBUL | ) Check if work will be performed by property owner only w ' Contact NaDle(s)� Contractor Trade:. Cell Phone: 1730 Land Lino: "Workers, Com p.documentation mustbe submit"ted with this application** Cell Phone: ^ Contact Person Tor Cmn1p||ance |n regards,to this project: Cell Phone: Land Line: Email: NOTES l Alarm system d associated electrical work mutt bib inspected bv,] TovVn.app[Oved electrical inspection 8g no longer allow systems to be cover(,!duntil such tkne as anas-built plan i's received and qpproved.!The installed system must match the septic layout mMfile—no exceptions. 3. A s- built drawings rhUst be' 'subnitt d prior to the inspection, if them has been o change tUthe subnitted plans. 4. If, for any [e hebuild(ng pprnnit application iswithdrawxn, 3O96ofth`e-fee isretained by the Town of[}ueensbury. After I year from the initia|Gpp|icatioDclat ', l00%ofthefeeisretained- | ` Any'permi't or approval granted-which is based upon orjsgranted in reliance upon�any-material rapresentationo | arnatoha|factorcirounnstenceknovvnbvuronbeha|fofanapp|icant, shaUbe void. Ihaveread the regujations and agree to abide by these and allrequirements of the Town of.Q.ueerisbury Sanitary Sewage Disposal!!Ordinance. PR|NTNAK8E' Benjamin �|GN/Tl]RE: '»"Vm/~r DATE: 5/3/2021 Septic Application . nevue.d Avmmz ' / 2,24-2_,lzPj� Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (1 of 2) Two ) full sets of plans Over 1,500 sq. ft. requires engineering stamp Design loads on plans: 115 Wind Floor Loads 40 psf (North of Rte. 149 60) 50 Ground Snow Load Sleeping Areas &Attics 30 psf Calculations Decks 40 psf Wind design for lake front properties Light and vent room schedule Window schedule with glass size & main doors/Air leakage < .5 cfm for doors, < .3 cfm for --- windows/Tempered glass in bathrooms Door schedule/Main entrance 36" door Emergency Escape or Bedrooms & Habitable Space Above-grade: 5.7 sq. ft. Grade: 5.0 sq. ft. 24" (h) x 20" (w) minimum 44" maximum height above door � r4 Window control devices 24" or less 2nd story or 72" above grade / Egress window from basement 5.0 sq. ft. Floor system sizing per table 502.3.1 - Residential check ERI or Prescriptive method jbt All foam plastic on foundation & crawl space covered by 15 minute thermal barrier (� Driveway length: 300' or more-12' width required/500' or more, turnaround required Foundation drainage on plans, if required 6" drop in 10' exterior grade F_ K S�:A—sue Framing cross section for each roof line, vertical fire stopping every 10' where Gl� required/joist spans pg. 127 Ice & snow shield—24"from exterior wall Platforms at exterior doors Stairway headroom 6'8"; all stairs 36" width Stair run and rise p� Winder run and rise Spiral stairs meet requirements Smoke detectors—battery backup & proper location, interconnected Heat detectors in attached garages—as of 4/1/2021 Bathroom fixtures—proper clearance Hall width-36" width Handrails more than four risers on open sides jj A_ Railing &guards > 30"/basement stairs included/closed risers more than 4" in height Safety glazing notes for required areas 1 Garage fire separation: %" gable end/5/8" under living space &%" on walls/20 min. door l and closer Residential Plan Review Revised March 2021 Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (2 of 2) ],� Garage floor sloped Attic access: gasket seal & R-value equal to roof insulation Roof over 30" —22" x 30"/Crawl spaces 18" x 24" access qA Carbon Monoxide detector outside lowest sleeping area, on every level & interconnected within 15' of sleeping area Soil test results, if required Septic to well or water line separation All paperwork signed Note on plans energy saving light bulb &9/ Blower door test agency paperwork ,Floodplain Permit required —check map: 2 feet above flood elevation Hurricane clips required Floors less than 2 x 10 covered by%" gypsum or 5/8" wood panel Manuals S &J required for heating system. Cold air return hard piped Separate room for draft HVAC or hot water heater with fresh air HRV shown and calculations Baffles at eaves for insulations and knee walls Makeup air for range hood >400 cfm yj fa - Continuous header for garage doors to end wall/3" nailing pattern/strapping All A Chimney rain cap shown for fireplaces NJ i� Deck hold down shown not less than 4 lags and bolts per table 507.2 Residential Plan Review Revised March 2021 TOWN OF OUEENSBURY 742 Bay Road, Queensbury, NY. 12804-5902 Septic System Checklist Plan to scale Received Deep hole perc test results from engineer/Architect if applicable(Town Approved Engineers and Architects;June 30 to April 15 Town Engineer for unapproved Engineers and Architects) �i All wells on property and adjacent properties shown C,.7,L %Water line shown Municipal or well 10'separation to any part of system *Setback to property lines show 10' or more for any part of system Septic tank and pump stations 10'from foundation 50'from any well/lake/wetland 10'from any waterline *Septic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank for 0',Separation required (field verification required) Septic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each Leech Field 20'from foundation 100'from any well 10'from water line Seepage pit 150'from well 50'from septic tank Seepage Pits 3-times diameter apart 19 Septic tank and pump stations over 30 gallons 50'from watercourse or wetland &distance from bottom of trench or system 24"to bedrock or mottling 36"within 1000' of Lake George %Leech field 100'from watercourse or wetland Toe of mound or bottom of retaining wall 10'from property line 100'from well 20'from Foundation Provide Engineer/Architect stamp for bed or design systems Department of Health Approval for all mobile home park new systems Flood Plain requirements Iw 2' above established flood elevation to bottom of system All tanks anchored or 2' above flood elevation ® ARDERSEN` WINDOWS & DOORS SOLD BY: SOLD TO: QUOTE DATE A r Nikki Howe 3/29/2021 I ' 460 Big Bay Road Queensbury NY, 12804 :JI�Jl VUti] 518-792-8601 Performance Report QUOTE NAME QUOTE NUMBER CUSTOMER PO# TRADE ID. . Seelye,Tim 549027 2104-Q84644 ORDER NOTES: - DELIVERY NOTES: Weighted Unit Unit Unit Total Contribution Qt Line Pos Unit Type/Dimensions Width Height Sgft Sgft U-Value SHGC VLT ER to Entire Job CPD Number 2 100 Al 100SHS 2' 11 1/4"X3' 11 35 1/4" 47 1/4" 11.57 23.14 0.3 0.28 6.94 AND-N-80-02064-00001 114" 2 100 131 100SHS 2' 11 1/4"X3' 11 35 1/4" 47 1/4" 11.57 23.14 0.3 0.28 6.94 AND-N-80-02064-00001 1/4" 1 200 Al 100SHS3040 351/2" 471/2" 11.71 11.71 0.3 0.28 3.51 AND-N-80-02064-00001 1 300 Al 100CS3026 351/2" 291/2" 7.27 7.27 0.28 0.25 2.04 AND-N-84-02444-00001 1 400 Al 100SHS2026 231/2" 291/2" 4.81 4.81 0.3 0.31 1.44 AND-N-80-02056-00001 Quote#: 549027 Print Date: 4/22/2021 3:04:40 PM UTC Page 1 of 2 All Images Viewed from Exterior Performance Report O0OTE..NAME. QUOTE NUMBER :`•:'i. :: CUSTOMER.BO#'- Seelye,Tim 549027 2104-Q84644 - " DELIVERY NOT Weighted Unit Unit Unit Total Contribution QtL Line Pos Unit Type/Dimensions Width Height Sgft Sgft U-Value SHGC VLT ER to Entire Job CPD Number Total Weighted Total Weighted Percentage of Total'Job Summary Total Sqft Contribution to Entire Average -Total Job Job Rated Units: 70.07 20.88 0.3 100% Non-Rated Units: 0 0% Quote#: 549027 Print Date: 4/22/2021 3:04:40 PM UTC Page 2 of 2 All Images Viewed from Exterior 2020 Energy'Star. Qualification Chart ® U` Steel Opaque &Lip-Cite Doors DOORS Glass Designs _.- _. -••'- •'',,^nGlass$Ize'(InC lies) 22i84' `20x64 =16x6A.- - 1axG4`..22x47_', '22x36'"., 2Dic36 22x27-� .Bx3G'" -.16,iAo "sxA2R 22ztoit-:22x10e, '27 i15'� "22icG;:a 7x18 '8z6 - -7x6•L: Decorative Glass .,tti'.OJ.' •.l'!,69' :i8;A5:• :.IL".r16 �.i4'.OJs,..•.t7LUa,` •.w.ft Decorative Glass—Wroughtlron 1 . . ' -,;;v.?E. ,at!,2r Frosted Glass aA?,ao st?ao. "81.23` Xv.I; Privacy&Textured Glass sr:z'" i3,r o; .zu.5. :ii.is :d[;is_: a't8t. Grilles Between Glass r::k'1c2G'= ':2s+.zo', •':251.15 ;,l i•':Is" 01.'Jo-''.2PLn6 .z.20?.Uo -'E06ti"s"" :ziTi.ua ...:- r23�r c' :::I:!1t., .e•.r _ .1 G•'.IJdJ -. ,-. Low-E Grilles Between Glass Miniblinds a:.:2s: 'aocis:` sii;ti- .ziJ.1d" 27;.1a• ":zi!.oi='`:i;:oz': :::2itni- Low-E Miniblinds 31:21 sli,;l; .zii.is', ,;a7i,in'`.:za,.iz .zAr;i2 zir.ue ::z6(.ou" '.2ur•n6 Clear Glass :tar.aa'; ;:Sa..:}ts" :>3L7 ' Y '-,25LI? 6' ^ o "n alr.ttp— y20;.GA:-•,:2f1t,Ofl; :20i.G_9,sn�2:+': :.��.Ir• +;a: �..lie:. 'tn,.69.� -zcv.tre".- -:zgi.ti,�_::zG:�:oG�`S:zu.G..: °..a: - - - - ,^( , is n ,r r o.. a or - +' - L6W-E Glass -'..29i>10:,,:.,;2ni.18' '"-.2:iLt 2-' '.2.J.0.. " ,;23i:Li' ;.23`69: .17s.+.G9:� :'.23'.Ue`" ".•._9..00``' P21..0! -:15:'.05.' ':f3i.05-"a 4,;,05:C •d3.r.0:i .t..il ::;".f:�„Uo. �'':191.05; '�i.v,US: `�d,,.d-, dot."a5t "d as `.Ut,05' Opaque a Loi =111111 ii =111 am :."'•,'`.:..•_- Glass Size.(Inehes) '22x80. .•20zR0'•,._:'':7 ?,; �22x64:, 22%47_ 1•„}' _ [2zx7nM ..,••, ':z2xG'. ;.,r _ -- 8z6I?x00', — _ . Decorative Glass .. ; ',:PS:'.17,•; ^.ri,',„. .. Li4i'.:'.- ':23/.2C' ..t:+'.'i?a ,'..i3?.L3"• .21;J5:, Decorative Glass—WroughtIror ?y"L'G j,'.i5i.2s• :j5i.2^o _.S io., Frosted Glass a3d'" ir:ao. :ay.lo' <81,23; Privacy&Textured Glass 2Gt.li''„2or:2" 2ar•27 22r.2G'' iSP.un'- zu.ie;. Grilles Between Glass .34 F. a ir:ir,, U.!,)C, 2sr.2ri` 26,ti?.'. Low-E Grilles Between Glass 21.1•r .29AW ;2ur,fa, Miniblinds Low-E Miniblinds C+v,27:. :?t:.at ir27 2,r.i5.: .2ar,ie• Clear Glass sAa6 :sAr:;;n"" 84::u ':2P,L'L3'' 0,.ris" 2iV.i,l C. (%,(sa 2Sr,tT- Low-EGlass aer.te;-:=.z ra6 Opaque liftlirates Freduui'is Erteigy Star Oisalrfied in eIISO States W IndlwtesPraduuiIsEnergyStir0ualifledi In Numberr.Mactor/SotarHeatGainCoefficient m x:Indicates Product Availability •Also Includes arch and round top lite. Indicates Product is NOT Ener6y Star Oualllied � k 020 Energy Star® Qualification Chart THERMAITRUO Steel Impact Rated Doors. °a°° DOORS Glass Designs w '-.',.GI8S5SIZ0'(InCheS) 22x64',,,, 20xG4 "'1Oxfi4'`.:.' '14x64,_ '22x47�' ,.22x36 20r36 'r �;21k15; ;'ax3G _ , ,,7x64,,; tx47.- 8x�6_—` Decorative Glass ,.2yf:26 28Z?G: 2G/.19: 21J.1y4°,--:221,1,d- tuhtl7s'`r-,1";?.07.:" .tE?:Ui<_ 1w.0, •�:18i.07 Decorative Glass—Wroughtlron14:; "-.'1�J,;U7 ;,.191.oi.:. ;,:r91:07<: ,';l9f.07.' :'i9/.07:. Frosted Glass .301,23 :'.30t..8 , 26l.21 23L1f .: 19r.gs, 19�013; aJl:US" Privacy&Textured Glass :23L2fi ,15ii19'. .;.2L/.14 J'1107, -:15/.07, :,:18I,07. ;:.12i.07`;. Grilles Between Glass ;•31f'25.\ J'I/2 Low-E Grilles Between Glass ;25/;13,' �51F13::: _':23hI0 °"r?21l:U>3: tal.t14'- :.fS Miniblinds ;33i:29' 3fsf.2S:: ''.3�la7;. 3t1i:17, ' G!.t.i 2E�.13'. =2i:'a15 zr./.U6" L11:11s Low-E Miniblinds -.30l.23t ,-,3GL23', ",-:2iil,LT': 26/:17,', \;23/.l'3; 23l.(3 Clear Glass :30F,2S ,36428, ,231.15 `:.2G/'.21 231.16 ';.2366` 791,68 _:1�!:013`: .'.:..1 'A6:;" 1J/,.OfS Low-E Glass201:09 _17f05" Glass•S-Z (Inches) ^,22x80_: 20z80;,_ 14x80'- 22x47.% 7x8o' Decorative Glass 3fl!:2ti :W2135-\ 25L1 J zz1,14.'- Decorative Glass—Wrought Iron ',3401,25 :.4sl:In Frosted Glass Privacy&Textured Glass 2Si.?6' 25/:i9. :22/J4- Grilles Between Glass ;3'll,.z5 :511.23 ,.27Lt6: :.241.'14'. Low-E Grilles Between Glass 25/.13.`, .25/.13', L3/.1\0, 21/1)8 Miniblinds 35J-23 ,:..351:23,, m/;i7;- Low-E Miniblinds 3(1(.23 30/:23 ;.26/.L7:- 231.t3 Clear Glass Low-E Glass .Indicates Product,is Energy,Star 0ualified iri ail 50"States" �. Numbers:U-Factor/Solar Heat Gain Coefficient � , Indicates Product is Energy Star:Oualified in Narfhern,Zdne-,', x:Indicates Product Availability Note:Impact-Rated products on this page utilize impact rated glass. ;Indicates Product is NOT Energy Star,Oualifled".,, Manual S Compliance Report Job: 795 bay rd Date: May 05,2021 Entire House By: Pian: 795 bay rd proje ct Information- For: cerrbne • • • gquipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 18780 Btuh Entering coil DB: 75.3°F Outdoor design WB: 71.0°F Latent gain: 1542 Btuh . Entering coil WB: 62.6°F Indoor design DB: 75.0°F Total gain: 20322 Btuh Indoor RH: 5.0% Estimated airflow: 1.004 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: YCJD24S4181+CH366C9+TM9E080C16MP11 Actual airflow: 807 cfm Sensible capacity: 0 Btuh 0% of load. Latent capacity: 0 Btuh. 06/o of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design D,B: -4.0°F Heat loss: 68358 Btuh, Entering coil DB: 65.5°F' Indoor design DB: 68.0°F Manufacturer's Performance. Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: York Model: TMPX08OB12MP11 Actual airflow: 807 cfm Output capacity: 16000 Btuh 111% of load Temp:,rise: 50 `F Meets.are all requirements.of ACCA Manual S. 2021-May-05 09:16:57 „= ' WCtghtsoft' R1ght-Sulte®Unlversa12017 17.0.16 RSU25116 page 1 ...scott.}angew qr y%Docurrierds%York1795 bay td.rup Caic=.M.17 Front Doortzces: 14 1 Form Residential Plans - ' - - • R_ _ RIPER 1 ACC . (Loads, Equipment, 15 Mar 09 Ad 07*XWOC.rPactrS0IM&M queensbury Header Information Contractor: REQ UIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes ❑ No E] Mechanical license: or MJ1AE Form'(and supporting worksheets): Yes E] No OEM performance data(heating,cooling,blower): Yes E] No Building plan#: 795"bay rd Manual D Friction Rate Worksheet: Yes. E No ❑ Home address(Street or Lot#,Block,Subdivision): , Entire House Duct distribution sketch: Yes No HVAC . ` . CALCULATION ` • 4 1 Design Conditions Buildinq Construction Information Winter Design Conditions Building Outdoor temperature: _4 •F Orientation: Front Door faces North Indoor temperature: 68 'F North,East,West,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 68358 Btuh Number of bedrooms: 1 Conditioned floor area: 1260 ft2 Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 °F Indoor temperature: 75 °F Windows Roof- G"rains difference: 27 gr/lb @50% RH Eave overhang depth: 0 ft Sensible heat gain: 20867 Btuh Internal shade: none Eve Latent heat gain: 171.3 Btuh eunds,drapes,ate. Depth Window Total heat gain: 22580 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC 14 Heating Equipment Data Cooling Equipment Data Blower Data Equipment type: Gas furnace Eckui2ment type: SplitAC Heating cfm: 807 .mace,Hea pump,Boller,etc. Ir ondltloner,Heat pump,etc. Cooling cfm: 807 Model: York Model: York Static pressure: 0 in H2O TM9X080B12MP11 YCJD24S41 S1 Fan's rated external static pressure for design airflow Heating output capacity: 7600 Btuh Total cooling capacity: 0 Btuh Heat pumps-capacttyatwlnterdesignou doorconditions Sensible cooling capacity: 0 Btuh Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh HVAC DUCT DISTRIBUTION 1 •1 Design airflow: 807 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL):_ 0 ft Available static pressure(ASP): 0 in H2O Friction rate: 9(� in/100ft Branch duct: Sheet metal Friction Rate-ASP+(TELx 10 ) I declare the load calculaton,equipmenL equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verificabon. Contractor's printed name: Contractor's signature: Date: Reserved for County,Town Municipality orAuthority having jurisdiction use. 'Home qualifies for MJ1AE Form based on Abridged Edition Checklist �"� wrlQOttSOft' Right-Suttee Universal 2017 17.0.16 RSU25116 Job: 795 bay.�d Proleet Summary Date: May 05,2021 Entire House By: Plan: 795 bay rd Froiept Information For: cerrone Notes: D- • n Information Weather: Glens Falls AP, NY,.U.S Winter Design Conditions Summer Design Conditions Outside db -4. OF Outside db 85 OF Inside db 68 OF Inside db 75 OF Design TD 72 OF Design TD 10 OF Daily range M Relative humidity 50 % Moisture difference 27 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 64488 Btuh Structure 17886 Btuh Ducts _ 3869 Btuh Ducts 894 Btuh Central vent (0 cfm) 0 Btuh Central.vent (0 cfm)' 0 Btuh Humnone idification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 68358 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 16902 Btuh Method Simplified Latent Cooling Equipment Load Sizing 'Construction quality Average Fireplaces -0 Structure 1542 Btuh Ducts 0 Btuh Central vent (0 cfm) 0- .Btuh 'Heating Coolingg (none)' Area ftz 1260 1260 Equipment latent load 1542 Btuh Volume_(ft3) 10080 10080 Air chan�gges/.hour 1.00 0.50 Equipment total load 18444 Btuh Equiv. (cfm) 168 84 Req. total capacity at 0.70 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make York. Make York Trade YORK Trade ADP Model TM9X080B12MP11 Cond YCJD24S41S1. AHRI ref �200869.1 Coil CH366C9_+TM9.E080C16MP11 AHRI ref 7185467 Efficiency 95.5AFUE Efficiency 12.2 EER, 14 SEER, Heating Input 80000 Btuh Sensible:cooling 16940 Btuh Heating output. 76000 Btuh Latent cooling 7260 Btuh Temperature,rise 86 OF Total cooling 24200, Btuh Actual air flow 807 cfm- Actual airflow 807 cfm Air flow factor 0.012 cfm/Bfuh Air flow factor 0.043� cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space.thermostat Load sensible heat ratio 0192 Calculations approved by ACCA to meet all requirements,of Manual J 7th Ed. - _ 2021-May-OS 09:18i57 -F - wrightsoft' RlgWSuite®universal 2017 17.0.16 RSuniir3 Page ...scott:langeworthy\oocumenis\Yoik\795 bay rd.rUp' Calc=MJ7 Front Door faces: N Right-M Workshe6t Job: b: T"bay rd- Endre-House Date: May'05,2021 Plan: 7.95 bay rd -- MANUAL 17th Ed. 4, Na-me of room EhUrie-House Roomi ROOM2 Room3 2 Length of%�ion s wall 238.0-ft� 138.0 ft 0 ft ft 33.0 3 • Room cam f0 k 772.0 ft. 120 x 8:0 ft 12.0 x 16.0. ft 41 Ceilings Condit.-Option 8.6 ft d 8.04t'j heat/bool 8.0 ft heat/cool '8.0 ft heatIdbiol TYPE OF CST HTM Area Load,(Btuh) Area 'Load'(Btuh) Area Load(Otuh) Area Load:(Btuh) ,Htg dlg EXPOSURE NO; Htq I(jig J#t�, Clg �M :Htg (M Htg Clg (M Hig , NH Nt. 5 Gross a 1211 4:0 0.7 1904 .... 1088 .... 224 264 Exposed b 0 P 111111 walls and .0 6 0 .111111 11101 mill partitions d 0 0 111111 111111 111111 e 0 0 Mill 111111 1111.11 f 0 0 111111, Mill .... .... 1111111 11111! 6 Windows and a 3D0 26.0 :* ­,i 95 2469 15 3 1 90 0 0 45 1170 ... glass doors b 0 0 0 0 0 0 0 0 0 Heating b 0 0 6 0 6 0 10 6• 0 e 0 0 0 0 0 0 0 . f 01 0 PI 0 0 0 0 0RH 7 Windows and North 17.0 25 425 is 255 '0 0 0 .glass doors NE/NW 1 0 0 00 0 0 .... .0 0 0 Cooling EIAIV, 62.0 15 .... 930 0 0 0 0 is 930 SEISW 0 0 0 o 0 0 0 0 0 South 30.0 56 1650 0 .... 0 0 0 30 900 H04 0 6 0 0 - 0 0 0 0 0 8 Other doors a 10D0 33.1 6.3 561 1855 350 1 38 11591 219 21 696 131 0 0 0 1 b 0 0 0 0 6 0 0 0 0 01 b 0 0 c 0. 0 0 -0 0 0 0 0 0. 0. 0 0 0 -0 9 Net, a 1211 4.0 0.7 1763 6942 1311 1038 4110 776 203 804 152 52 219 867 164 exposed b 0 0 Illill 0 0 111111 0 0 111111 6 0 111111 0 0 WallSrand C 6 0 till!!, 0 0 111111 6 0 Ifill-I 'd 6 imll 0 0 partitions d 0 0 111111 0 0 !!lilt 0 0 Mill 0 0 Mill .0 0 6 0 d mil! 6 0 111111 0 0 111111 0 0 111111 .0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 _0 0 10 Ceilings` a 16K0 20.7 9.8 1260 26037 12295 M It-95-3 7533 96 1984 937 216 4463 2108 b 0 0 111111 0 0 111111 Mill 0 0 c 0 0 Milt 0 0 1111110 0 0 0 111111 0 0 0 0 !lull 0 0 d 0 0 111111 0 0 111111 0 0 111111 0 0 .111111 0 0 e 0 0 111111 0 0 111111 0 0 mill 0 0 01111 �0 �0 f 0 0 111111 0 .0 Mill 0 6. 111111 0 6 Ililli. 0 0 -3 - "03 33 1925 II Floors a 22A6 .58. 0 238 1W80 0 136 7932 0 28 1 0 0 (Note:room b 0 0 111111 0 0 11111 0 0 111IR 0 0 111111 0 0 Perimeter .0 0 0 lillif 0 0 111111 0 0 111111 0 0 1111h '0 0 is.displ. A 0 0 111111 0 0 111111 0 0 Mill 0 0 '111111 '0 for slab e 0 b lilill 0 0 Illin 0 0 111111- 0 6 fillit floor,.) f d 0 111111 0 0 Illill 0, '0 111111 0 0 111111 0 0 12 Infiltration ;a 88:1 61.1 151 13366 92,4 50 4406 305 21- 1850 129 45 3965 275 Ventilation 0 0 0 0 0 0 0 13 Subtotal loss:i6+8_4-11+12 64488 33950. 6967 -090 ...... Less,extenial heating '0 .... 0 0 b __ Less.transfer 0 6 0 0 Heating0 0 .... redistribution 14 Duct loss 60/a 3%9 W/o 2037 6% 418 6% 743 15 'Total =13+14- W358 ... . .... 35986 7385 13134. 10 !M,gains: People @ 0 0 0 .... 0 0 0 r @ 1200 0 0 0 0 0 ... 0 0 0 17 Subtot RSH gairv--7+8.._4-12+16 ... 178W .... 9090 .... 1348 4�77 Lest external cooling' 0 0 ;o 6 Less trareef 0 0 6 Coolirig-redidtfibUtloh - 0 0 .N. .0 0 18 Duct gain - 5% 1994 501e 454 86A 67 5% 219 19 Total RSH gal0(17+18)-PLF 1.00 187801 1.00 95441 1.00 1416 1.00 4696 20 Air reqUired,winj 8071 807 425, 41.0 61, 155 197 Calculations approved byACCA:to meet all requirements of.Manual J 7th Ed:- +P- wrightsoft" 2021-May-05 09:16:57 RlgWSufteD Universal 2017 11.6.16 RSU25116 Page 1 ...scott.16nge'worthylDocumentsNYotkl7.95'biy rd.rup"'Cite-_-i MJ7:-Front D6or faces: N RiOW.@ W®.rksheet Job: 796 bay rd Entire House Date: May 05,2021 sy: Pfan: 795 bay rd MANUAL J:7th Ed. 1 Name of room Rooti4 Rooms 2 Length of exposed wall 26.0 ft 15.0 ft 3 Room dimensions 10.0 x 12.0 ft 8.0 x 7.0 ft 4 Ceilings Condit.Option 8.0, ft heat/coot 8.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Area EXPOSURE NO, Htg I Clg (ft� Htg Clg (M Htg I Cig Htg Clg Htg Clg 5 Gross a 1211 4.0 0.7 208 * 120 ""' "*` **" '~• '~' Exposed b 0 0 will walls and c 0 0 111111 •", ",. !!l111 *"" *'"" '••' •,,, „•* partitions d 0 0 HIM ,,,_ "•• 1!!!!! „'• •* •"` •": `"*'. 6 Windows and a 3D0 26.0 '• 25 650 """" 10 260 '*" ••*` '•" glass doors b 0 0 0 "`" 0 0 "" Heating c 0 ~ 0 0 ~" 0 0 e 0 ... 0 0 .,. 0 0 *.*. •.,. 7 .Windows and North 17.0 0 10 "" 170 '~* "'• glass doors NE/NW 0 0 "" 0 0 '*~ 0 **** '•'* Cooling E/W 62.0 0 ,"' 0 0 ,", 0 ,**• •••• SE/SW 0 0 "•* 0 0 "*` 0 "'* "'• South 30.0 25 ~" 750 0 "'" 0 •"' "" Harz 0 0 ••" 0 0 ...• 0 •••• •••• 8 Other doors a 10DO 33.1 6.3 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 C 0 0 0 0 0 0 0 0 9 Net a 1211 4.0 0.7 183 725 137 110 436 62 exposed b 0 0 111111 0 0 HIIII 0 0 walls and c 0 0 IllM 0 0 111111 0 0 partitions d '0 0 111111 0 0 .111lII 6 0 e 0 0 Mill 0 0 111111 0 0 f 0 0 !!11!! 0 0 Bllll 0 0 10 Ceilings a 16KO 20.7 9.8 120 2480 1171 56 1157 546 b 0 0 111111 0 0 111111 0 0 C' 0 0 111111 6 0 111111 0 0 d 0 0 !I!!1! 0 0 p!!11 0 0 e. 0 0 HIIII 0 0 11111! 0 0 f 0 0 HIIII 0 0 111111. Q 0. 11 Floors. a 22AO 58.3 0 26 1516 0 15 875 0 (Note:room b 0 0 111111 0 0 1 !!111 0 0 perimeter c 0 D IIllll 0 0 111111 0 0 is displ. d 0 0 111111 0 0 111111 0 0 for slab e 0 0 111111 0 0 Ilmi 0 0 flows) f 0 0 InIll 0 0 111111 0 0 '12 Infiltration a 88.1 6.1 25 2203 153 10 881 61 Ventilation 0 0 0 0 13 Subtotal loss=6+8..+11+12 ~~ 75-n *"~ 3609 Less external heating •'"• 0 •,,' ••,• 0 •"` -*'• ,• "'• ~~ Less transfer *,•' 0 ••,• ••_« 0 •:•• ,••* •,•• •••• Heating redistribution •*~ 0 '~' **~ 0 14 Duct loss 6% 454 '~` 6% 217 "" "'• "*' 15 Total loss=13+14 8028 *"' 3825 ""' "'• "'• •"' *'*" 16 int.gains: Pewple Q. 300 0 '"* 0 0 ""' 0 Apfx' �. 1200 0 .,,, 0 0 .:.. 0 ..._ ,..: 17 Subtot RSH gain=7+8..+12+16 "" "•' 2211 ' 860 "._ '"'* ."' "'• Less external cooling •„• "" 0 ' '*~ 0 ••~ '*•• •"' *'•' Less-transfer :.,, .... 0 ..,: +:. 0 .... ,.,, ..:.. .... Cooling redistribution "" ••" 0 0 "" *'•` "•" „" 18 Duct gain 50% *"* 111 «50/0 43 19 Total,RSH gain=(17+18)"PLF 1.00 2321 1.00 *"` 903 20 Air required(cfm) 95 100 45 39 Calculations approved by ACCA to meet all.requirements of Manual J`7th Ed. wciglt>ttsoft' 2021-May-05 09:16:57 Right-SuiteO'Universal 2617 17.0.16 RSU25116 Page P+ ...scott.langeworthytDocuments\York1795 bay rd.rup C61c,=MJ7 Front Door faces: N 9S MAXis HEA! RECOVERY VENTILATO R ENGINEERING DATA THERMALLY CONDUCTIVE, PATENTED DEFROST ALUMINUM CORE Recirculating damper defrost system. The Gross-How heat recovery care transfers heat between the two airstreams.It is easily: removed for Gleaning or service. CASE Twenty gauge prepainted galvanized steel for superior corrosion resistance.Insulated to MOTORS AND BLOWERS prevent exterior condensation.Drain connections 2-1/2 in,(12 rum)OD.Balancing parts Each airstream has one centrifugal blower driven by a common PSC motor with multiple are located on door. fan Speed Operations. ELECTRONICS FILTERS The DXPL02 control included with the unit can be wall mounted in a central location of Washable air filters in exhaust and supply air streams. the home.3 wire 20 gauge(min.)100 ft length(max.). MOUNTING Four threaded inserts at corners of the cabinet designed to accept the"s"hooks and WAMANW hanging straps supplied with the unit. year units ta"0 wohme WWM01y(M Ithe HRV core Md a 5 teptatemell'tt pads wkrranty. ............ .................... .............. ............. ............ .......................... .... aua(Haod Weather Hood TechGrille Terminator A^ 99190 99-EAG4 Fitting 99-194 99-186 99-ERGS 99-TM4 iS 99-187 99-EAG6 99-TN 99-EAGS 99-TM6 ...................... ..................... ....... ...... .................... LIFEBREATH CONTROL OPTIONS TIMER OPTIONS 99-DET0I-Lifebreath 20/40/60 Minute Timer 4:iAtIll'L:L� initiates high sneeLi ventilation for 20,40 or 60 minutes.3 wire connection. 5 speed fan operation on each mode 99-BET02 2 speed fan operation(Low/High) Wireless Lifebreath 20/40/60 Minute Timer I Initiates high speed Ventilation for 20,40 or 60 Continuous low speed fan operation i minutes.Wirelessly connects to main control for Humidity control through adjustable Deliumidistat ease of installation.40'approximate range. EXCuSive to Lifebreath. Large digital LCO screen 99-RX(32-Wireless Lifebreath Repeater V Extends range of 99-DET02 Wireless Timers.Plugs LED status indicator lights into 120V power outlet.Wirelessly connects to Continuous Ventilation V/ main control and 99-DET02.install at halfway point between timer and main wall control if timer Continuous Recirculation is out of range. 20 ON140 OFF 10 ON/50 OFF 20 ON/40 Recirculation V, 20140160 min.High speed override button 99-DXPLO-2' 99-DET02 Compatible with 99-DET02 Wireless Timer 3 wire connection L IFEBRER TILY 1 91 Indow Ail SyStCMS 69-95MAX(O1-01-18) www.tifetjreath.com 9,5 MAX HEAT ■ PERFORMANCE (HVI CERTIFIED) ° r % .r . i . i VAC @ 6011z 120 Net Supply Airflow 68'(32) 66(31J 64(30) 59(28) 55(26)_ Watts t tow Speed 59 �lFm'j�°�� � Gross Supply Airflow 76(36) 72(34j 70(33) 66(31) ' 61(29) Watts/High Speed 89 Gross Exhaust Airflow 87(41) 85(40J 83(39) 78(37) 76(36) Amp Rating .9 B0 ......................................................................... WEIGHT: Sensible Effeotivenoss(ASEj 32°F(0°C} 88°l0 52 LBS(23.2's KG) @60CFM(28Us) 70 ......��" �............................. .. Sensible Efficiency(SRO 92°F(0°C} 75°-0 60 SHIPPING WEIGHT: @ so MA 128 Us) E S5 LBS(25.4 KG) Sensible Efficiency(SRO 3 ......................................... 32'F(0°C) 7No 0 40 ........ . . ................................ Sons161e Etiic(oncy(SRO a 30 ................................. ....... ........... t�OM Se 61 CPA(29 Us) -Irf F25%) 68°k Front clearance of 25 in.(635 mm)is 20 ............. ............`.,....... .......... recommended for servicing unit Round duct Ia ...,....................................... ............................ connections are 5 in.(127 rum)and oval collars use 6 in.(152 mm)connections. 0A 0.2 0.3 0.4 0.s 0.6 Static Pressure(ih w.9.) ARUS M II 90®[so °may.._. CERTIFIED unsm o FRONT VIEW TORVIEW 5 in.(127 mm) Round Collars State air to outside Blower— Fresh air from outside � cz!) Stale air from inside Removable Heat to 'Fresh air to inside • Recovery Core .- 6 In.(152 rural Round Collars Condensate Drain I, 19112 In:(469,mm) _I ......................................................................................................................... ... WARRANTY Date: tinift rama Ifftrim_ warranty Contractor: Tag: a r e p. Project• Oty: - Supplier: Quote#: Alt units conform to csA and ULstandards Engineer ail . Control: Su LIFEBRER I r7 iF Indoor Air Systems Timer: Timer Qty: 69-95MAX(01-01-18) Wway.tife6reath.cgm REScheck Software Version 4.7.1 Compliance Certificate ...r - Project Seelye Residence D E C E 0 V FE Energy Code: 2009 IECC APR 14 2021 Location: Lake George, New York Construction Type: Single-family TOWN OF QUEENSBURY Project Type: Alteration BUILDING&CODES Climate Zone: 6 (7377 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 795 Bay Road Timothy Seelye Benjamin Nassivera Queensbury, NY 12804 Compliance: Compliance: 1.0%Better Than Code Maximum UA: 100 Your UA: 99 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Perimeter Wall 1: Wood Frame, 16"D.C. 900 21.0 0.0 0.057 46 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 60 0.270 16 Door 1: Glass 20 0.300 6 Door 2: Solid 20 0.220 4 Ceiling 1: Cathedral Ceiling 725 28.0 0.0 0.037 27 Compliance Statement. The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted-with the permit application.The proposed bulldlqgoas been ed to meet the 2009 IECC requirements in REESSccheck Version 4.7.1 and to comply with the mandatory requirem isted ' t desi check Inspection Checklist. 'h'rwliA.o►ia� �k�•SSIV@V� u Name-TitI4 ignature Da 289.15-1-32 RC-0224-2021 Seelye, Timothy & Deborah 795 Bay Rd Residential & Septic Alt 668 sJ Project Title: Seelye Residence Report date: 03/24/21 Data filename: C:\Users\bnassivera\Documents\795 Bay Road\795 Rescheck.rck Pagel of 7 f . REScheck Software Version 4.7.1 Inspection Checklist Energy Code: 2009 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.2 ;Construction drawings and OlDoes Complies [PRl]1 documentation demonstrate Not j energy code compliance for the s building envelope. #❑Not Observable l❑Not Applicable ; 103.2, ;Construction drawings and ;[:]Complies 403.7 documentation demonstrate tlDoes Not [PR3]1 ;energy code compliance for ij lighting and mechanical systems. ❑Not Observable ;Systems serving multiple ❑Not Applicable ;dwelling units must demonstrate ;compliance with the commercial code. 403.6 s Heating and cooling equipment is; Heating: Heating: ;❑Complies [PR2]2 sized per ACCA Manual S based Btu/hr Btu/hr ElDoes Not on loads per ACCA Manual J or j Cooling: Cooling: ;❑Not Observable other approved methods. Btu/hr Btu/hr I❑Not Applicable 1 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Seelye Residence Report date: 03/24/21 Data filename: C:\Users\bnassivera\Documents\795 Bay Road\795 Rescheck.rck Page 2 of 7 Section # Foundation Inspection Complies? Comments/Assumptions &Req.ID 303.2.1 A protective covering is installed to ;❑Complies [F011]2 protect exposed exterior insulation :❑Does Not and extends a minimum of 6 in. below grade. :❑Not Observable', 1❑Not Applicable 403.8 Snow-and ice-melting system controls;❑Complies [FO12]2 installed. ;❑Does Not ❑Not Observable j ;❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Seelye Residence .- Report date: 03/24/21 Data filename: C:\Users\bnassivera\Documents\795 Bay Road\795 Rescheck.rck Page 3 of 7 Section Plans Verified' Field Verified # Framing/Rough-in Inspection Value Value . Complies? Comments/Assumptions & Req:ID 402.1.1, ;Door U-factor. ; U- ; U- ;❑Complies ;see the Envelope Assemblies 402.3.4 ; ❑Does Not ;table for values. [FRI] 1 ,❑Not Observable ❑Not Applicable 402.1.1, ;Glazing U-factor(area-weighted ; U- U- ;❑Complies ;See the Envelope Assemblies 402.3.1, i average). UDoes Not I table for values. 402.3.3, ; ;❑Not Observable 402.5 ! ; ; :❑Not Applicable [FR2] � � � , 4) 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not twith the NFRC test procedure or I ;taken from the default table. ❑Not Observable ❑Not Applicable 402.4.4 ;.Fenestration that is not site built ❑Complies [FR20]1 Iis listed and labeled as meeting ❑Does Not j AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC. ❑Not Observable l400 that do not exceed code ❑Not Applicable ; limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not io and labeled to indicate s2.0 cfm iii ❑Not Observable leakage at 75 Pa. 1EINot Applicable 403.2.1 ;Supply ducts in attics are R- ; R- ;❑Complies [FR12f1 !insulated to ?]1-8.All other ducts : R_ R- in Not in unconditioned spaces or ; ;❑Nat Observable !outside the building envelope are ❑NotA licable ;insulated to zR-6. Pp 403.2.2 ;All joints and seams of air ducts, ❑Complies [FR13]1 Lair handlers,filter boxes, and ❑Does Not building cavities used as return ;ducts are sealed. ❑Not Observable ; �. ❑Not Applicable 403.2.3 {Building cavities are not used for ❑Complies [FR15]3• }supply ducts. ❑Does Not ❑Not Observable 1EINot Applicable 403.3 HVAC piping conveying fluids R- R- ❑Complies [FR!7]2 above 105°F or chilled fluids El Does Not below 55 °F are insulated to ?R- ;❑Not Observable3. ' ❑Not Applicable 403.4 Circulating service hot water R- ; R- ;❑Complies [FR18]2' pipes are insulated to R-2. ❑Does Not GJ ;❑Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air i❑Does Not intakes and exhausts. IE]Not Observable . ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2, Medium Impact(Tier 2) 3 1 Low Impact(Tier 3). Project Title: Seelye Residence Report date: 03/24/21 Data filename: C:\Users\bnassivera\Documents\795 Bay Road\795 Rescheck.rck Page 4 of 7 r Section Plans Verified Field Verified # Insulation'lnspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable IE]Not Applicable 402.1.1, ;Wall insulation R-value. If this is a: R- R- ;❑Complies ;See the Envelope Assemblies 402.2.4, !mass wail with at least 1/z of the ❑ Wood ;❑ Wood ;❑Does Not table for values. 402.2.5 ;wall insulation on the wall ❑ Mass ❑ Mass :❑Not Observable (IN3]1 ;exterior,the exterior insulation q� I requirement applies. ;❑ Steel i❑ Steel tlNot Applicable 303.2 ;Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. FDoes Not 4 ; 3❑Not Observable �❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Seelye Residence Report date: 03/24/21 Data filename: C:\Users\bnassivera\Documents\795 Bay Road\795 Rescheck.rck Page 5 of 7 r ' Section Plans Verified Field Verified # Final Inspection Provisions Complies? Comments/Assumptions & Req.ID Value Value 402.1.1, ;Ceiling insulation R-value.Where ; R- R- ;❑Complies ;See the Envelope Assemblies 402.2.1, :> R-30 is required, R-30 can be ❑ Wood ❑ Wood ;❑Does Not Itable for values. 402.2.2 ;used if insulation is not ❑ Steel ❑ Steel [FI1]1 ;compressed at eaves. R-30 may ; ❑Not Observable be used for 500 ftz or 20% I ; ;❑Not Applicable ; ;(whichever is less)where ;sufficient space is not available. 303.1.1.1, ;Ceiling insulation installed per ❑Complies ; 303.2 manufacturer's instructions. ❑Does Not [FI2]1 ;Blown insulation marked every j ;300 ftz. El Not Observable ; I❑Not Applicable 402.2.3 ;Attic access hatch and door R= R- ;❑Complies [FI3]1 :insulation zR-value of the ;❑Does Not adjacent assembly. J ;❑Not Observable ; ❑Not Applicable 402.4,2, i Building envelope tightness ACH 50 = ACH 50 = QComplies ; 402.4.2.1 :verified by blower door test result; UDoes Not [FI17]1 :of<7 ACH at 50 Pa.This j j !requirement may instead be met ; I❑Not Observable Ma visual inspection, in which ;❑Not Applicable case verification may need to occur during Insulation I Inspection. ; 403.2.2 ;Post construction duct tightness cfm cfm ;❑Complies [FI4]1 test result of s8 cfm to outdoors, ❑Does Not or:512 cfm across systems:Or, ❑Not Observable rough-in test result of 56 cfm ; across systems or:54 cfm ;❑Not Applicable ; without air handler. Rough-in test ;verification may need to occur ; ;during Framing Inspection. I I 403.1,1 Programmable thermostats ;❑Complies [FI9]z installed on forced air furnaces. �❑Does Not ❑Not Observable �❑Not Applicable ; 403.1.2 Heat pump thermostat installed ;❑Complies [FI10]2 on heat pumps. ❑Does Not 4 ;❑Not Observable HNot Applicable 403.4 . Circulating service hot water k'❑Complies [FI11]z systems have automatic or i❑Does Not a accessible manual controls. 3 ❑Not Observable ; i❑Not Applicable 404.1 ;50%of lamps in permanent #❑Complies ; [FI6]1 !fixtures are high efficacy lamps. ❑Does Not IE]Not Observable ❑Not Applicable 401,3 Compliance certificate posted. ; ❑Complies [FI7]2 ❑Does Not J IE]Not Observable #❑Not Applicable 303.3 !Manufacturer manuals for i❑Complies [F118]3 mechanical and water heating ❑Does Not sequipment have been provided. ❑Not Observable 1ElNot Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2). 3 1 Low impact(Tier 3) Project Title: Seelye Residence Report date: 03/24/21 Data filename: C:\Users\bnassivera\Documents\795 Bay Road\795 Rescheck.rck Page 6 of 7 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Seelye Residence Report date: 03/24/21 Data filename: C:\Users\bnassivera\Documents\795 Bay Road\795 Rescheck.rck Page 7 of 7 Page No. of Pages Air-Tite Insulation Systems, Inc. Spray Foam Insulation Contractor 19 Tanglewood Drive South Glens Falls, N.Y. 12803 518-361-3678 PROPOSAL SUBMITTED TO PHONE DAT �6 d P STREET JOB NAME 5 � CITY,STATE and ZIP CODE JOB LOCATION ARCHITECT DATE OF PLANS JOB PHONE We hereby submit specifications and estimates for: .................................�..............................................._........................_.................................................................. .................................................................................................................................... ........................... .�GS .I %. N........................ .1�w ......................................................................_.........................................................................................................................................-.............................................._.. ......................_.................................................................................................... .................... .................................................................. ..... ............. _........................ .................................................................... ............. ............................ _..............._ ..._5... /�.....e.�✓..................�l2............... tn...._Psi.`........P................�f ............/_dD................._oPrt ............�1i..f�� .........................................................._.. ....................................... ,.........5........... ��..:_,3,5 .......o _..........Cse..o ..............c-p1 ....._ ....._..._ /�s�r./ a ............................._...................................... .......................................................................................................................................-..............................................................._............................................................................................................................................................... ................ .... 11.......c� Q ............4/ A .................all...........I e......:.........5.. ....1�..��..........�����....._`3...�/�-v?/...._.............. ................... ...........C'4fe.�.............G Q �............. lJ. '1............%I1S..... /(/................................................................................................................................................................. ..... l......... ............................._.................................................................................................................................. _...... P�IJ../?..................................��- .................................../ ...............-..................................................................._..................................... .............. ........................................... ......................................... ................................ ............................................................................................................... ............................................ _............................................................. ................................... ........ ............. ....... ........ Me VrapgSP hereby to furnish material and labor — complete.in accordance with above specifications, for the sum of: ). Payment to be made as follows: dollars($ All material is guaranteed to be as specified. All work to be completed in a workmanlike manner according to standard practices.Any alteration or deviation from above specifications Authorized involving extra costs will be executed only upon written orders, and will become an extra Signature charge over and above the estimate.All agreements contingent upon strikes,accidents or delays beyond our control.Owner to carry fire,tornado and other necessary insurance.Our Note:This proposal may be workers are fully covered by Workman's Compensation Insurance. withdrawn by us if not accepted within days. Eateof aurr of propoSttl—The above prices,specifications ns are satisfactory and are hereby accepted.You are authorized Signature rk as specified.Payment will be made as outlined above. tance: Signature 2ZA ���Z\ Envelope Leakage Test Testing Company: Technician: Name: LoCascio.Energy Solutions Name: Anthony LoCascio Address: 20 Ogden Rd. Credentials: HERS Rater#4242961 Queensbury,, NEW YORK 12804 Phone: 5188573144 Email: tony@locascioenergysolutions.com Building Information: Customer Information: Project ID: 795 Bay Name: Tim Sealy Address: 795 Bay Rd Address: Queensbury , NY 12804. Geo-Tag Data: Latitude:43.362071 Longitude: 73.657358. Timestamp: 2021-10-12 12:20:43 Measured Leakage: 0.24 CFM50/ft',(Env. Area) Leakage Target: 0.30 CFM50/ft2 (Env. Area) Compliance With Leakage Target: Pass Test ID: 795 bay Purpose of Test: NY IECC 15 Env. Leakage Measured CFM50: 615.4 (+/-0.6%) Effective Leakage Area: 33.9 in' `Building Volume: 6,543.0 ft3 Enclosure Surface Area: 2,600.0 ftZ Coefficient(C): 48.6 (+/-4.8%) Exponent(n): 0.649 (+/-0.013) Correlation Coefficient: 0.99980 - Test Standard: ASTM E779 (single mode) Test Mode: Depressurize Test Characteristics: Pre Indoor Temp: 65.OF Post Indoor Temp: 65 OF Pre Outdoor Temp: 65 OF Post Outdoor Temp: 65 OF Altitude: 388.0 ft Time Average Period: 10 seconds .Test Date and.Time: 2021-10-12 12:25:47 800 600­ • Depressurize — 500— m 400- Ca 300 — ;---;-- -- ------- — ---- (---- E-- J - � f 100-- ,- 4 5 6 7 8 910 20 30 40 50 6070 Building Pressure(Pa) ;s CCE0 E OCT 2 2021 I TOWN OF QUEENSBURY COMMUNITY DEVELOPMENT Envelope Leakage Test Test Readings: Target(Pa) Bldg (Pa) Adj Bldg (Pa) Fan (Pa) Flow(cfm) Confia Baseline -0.4 -60.0 -59.4 -59.1 -134.5 688.2 Ring B -54.0 -54.7 -54.4 -118.7 646.8 Ring B -48.0 -48.5 -48.1 -103.3 603.7 Ring B -42.0 -42.9 -42.5 -87.5 556.0 Ring B -36.0 -37.1 -36.8 -70.4 499.4 Ring B -30.0 -30.6 -30.3 -55.7 444.5 Ring B -24.0 -24.9 -24.6 -42.8 390.0 Ring B -18.0 -19.3 -19.0 -30.2 328.4 Ring B Baseline -0.3 Test Equipment: Flow Device: . Model 3 110V Fan Serial#: 3173 Custom Calibration Date:2021-02-10 Pressure Gauge: DG1000 Serial#: 3173 Calibration Date: 2019-02-18 Deviations from Standard: • None Comments: None Report by TEC Auto Test 1.8.0 (210),©2021 The Energy Conservatory, Inc. Page 2 of 2 RUCINSKI HALL ARCHITECTURE ��`' Ronald Richard:Rucinski Ethan Peter.Hall 1.34 Dix Avenue Glens Falls NY 12801 Voice 518 741 0268 Fax 518 74.1 0274 Email . ephall@nycap.rrcom 795 Bay.Road Seeley Residence 19 July 2021 Town of Queensbury Building Department 742 Bay Road Queensbury. NY. 12804 Re: Installation,of Replacement Sewage Disposal System At the above referenced project location this office observed the installation of the new septic tank, distribution box and gravity laterals prior-to backfill: .This installation is acceptable to this office. If there are any questions glees contact our.office to discuss. 4. �'^' Six)A�� ; Regards, 'r` Ethan eter.Hall ,a .,3 2-24 Architect1`:� = ' � � �.._ JUL TOWN� OF OUE=1 8BURY BUILDING 8,COD;"S AS gUIL�" 1