Loading...
SOLAR-0768-2021 Office Use Only t Permit#: EOLA e— 01-b 6 a 202� Permit Fee:.$ gr � 742 Bay Road,Queensbury, NY 12804 P:518-761-8256 www.aueensbury.net Invoice#: Flood Zone? Y UN Reviewed By: 'SOLAR PANEL PERMIT APPLICATION SITE INFORMATION: Project Location: 7 Amethyst Dr Tax Map ID#: 308.14-1-28 Subdivision Name: PROJECT INFORMATION: Re ntial:Q Commercial Other: ✓Single Family Multi-Family �x t Are the solar panels? 0 Purchased Leased ` Estimated cost of construction: $26,582.00 Total System Capacity Rating (sum of all panels): >= Solar PV System: 10.85 kw DC � �C Select System Configuration: < X Supply side connection with micro inverters Supply side connection with DC optimizers Supply side connection with string inverter Load side connection with DC optimizers X Load side connection with micro inverters Load side connection with string inverter Solar Panel Application Revised January,2021 DECLARATION: 1. 1 acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the WS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations. 5. A third-party electrical inspection will be completed at which time the Town of Queensbury's Building and Codes Enforcement department will be contacted to complete an inspection of the final installation of the solar panels. Please sign below to affirm that all answers are correct and that you have met all of the conditions and requirements to submit a unified solar permit. I have read and agree to the above: See attached Homeowner's Signature Date 10.12.21 Solar Co. Representative Signature Date Solar Panel Application Revised January 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Property Owner(s): Name(s): Nathan Etu Mailing Address, C/S/Z: 7 Amethyst Dr, Queensbury, New York 12804 Cell Phone: _(214 )632-7952 Land Line: Email: • Solar Contractor: Workers' Comp documentation must be submitted with this application Business Name: Kasselman Solar, LLC. Contact Name: Loreen Harvey Mailing Address, C/S/Z: 279 Broadway bldg 2, Menands, NY 12204 Cell Phone:_(518 )478-3906 Land Line: _( ' ) Email:LHarvey@kasselmansolar.com • Electrical Contractor: Workers' Comp documentation must be submitted with this application Business Name: Kasselman Solar, LLC Contact Name: Ernesto(Gino)Cimmino Mailing Address, C/S/Z: 279 Broadway bldg 2, Menands, NY 12204 Cell Phone: _( 518 )3.68-3196 Land Line: _( ) Email:ginoc@kasselmansolar.com Contact Person for Compliance in regards to this project: Loreen Harvey Cell Phone: ( 518 )478-3906 Land Line: Email:LHarvey@kasselmansolar.com Solar Panel Application Revised January 2021 c PLEASE INCLUDE WITH YOUR SUBMITTAL: 1. Completed Solar Panel Installation permit application THREE (3) COPIES OF.THE FOLLOWING: 2. Signed and stamped architect or engineer solar plans, which include: a. Design/snow load b. Letter indicating rafters can handle additional load of solar panels and snow c. Proper setbacks from ridgeline for Fire Department access d. Rapid Shutdown 3. Plot plan indicating proposed structure to hold solar panels ADDITIONAL IMPORTANT INFORMATION: 1: Any changes to the approved plans prior to or during construction will require the submittal of amended plans, additional reviews and re-approval. 2. If, for any reason, the building permit application is withdrawn, 30% of the fee is retained by the Town of Queensbury. After 1 year from the initial application date, 100% of the fee is retained. Solar Panel Application Revised January 2021 - . DocuSign Envelope ID:6768FOEF-099C-4194-A1CC-45A7AD4C94C7 279 Broadway - Building#2 ` K.: .k:a's:5ehrxtan : L Menands,NY 12204 (518)-478-8365 (518)'-953-1095 Fax Nathan Etu ' I (Customer) hereby authorizeKasselmari Solar LLC,to act as customer,agent&contractor,and to submit all necessary permit applications and supporting documents to the,Town.Building Department on my behalf. Nathan Etu Customer Name(Print) DOCUSIgned by: C U S FI J gTIOJf ,e 7 Amethyst Dr Queensbury New York 12804 Customer Address Queensbury Municipality that issues your Building Permit DocuSigned by: t -�h wah Kas 4q�10?4�nployee Signature yoRlt workers' CERTIFICATE OF INSURANCE COVERAGE t—, STA7E Compensation under the NYS DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW Board PART 1. To be completed by Disability Benefits Carrier or Licensed Insurance Agent of that Carrier I a. Legal Name and Address of Insured(Use street address only) lb.Business Telephone Number of Insured 518 478-8365 Kasselman Solar LLC lc.NYS Unemployment Insurance Employer Registration 20 Walker Way Number of Insured Albany,NY 12205 1d.Federal Employer Identification Number of Insured or Social Security Number 464740969 2. Name and Address of the Entity Requesting Proof of 3a. Name of Insurance Carrier Coverage(Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Queensbury 3b.Policy Number of entity listed in box"la": 742 Bay Road DBL441239 Queensbury,NY 12804 3c. Policy effective period: 03/24/2021 to 03/24/2022 4.Policy provides the following benefits: a. ® Both disability&paid family Ieave benefits b. ❑ Disability benefits only. c.❑.Paid family leave benefits only 5.Policy Covers:: a. ® All of the employer's employees eligible under the New York Disability&Paid Family Leave Benefit Law b.❑ Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability Benefits insurance coverage as described above. Date Signed March 5,2021 By 2- (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carver) Telephone Number (800)233-0115 Title Authorized Representative IMPORTANT: If box"4a"is checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If box"4b,4c or 5b"is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board,DB Plans Acceptance Unit,20 Park Street,Albany,New York 12207. PART 2. To be completed by NYS Workers' Compensation Board (Only if box"4b" of Part 1 has been checked State Of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability Benefits Law with respect to all of his/her employees. Date Signed By (Signature of NYS Workers'Compensation Board Employee) Telephone Number Title Please Note.Only insurance carriers licensed to write NYS disability benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized•to issue Form DB-120.1. Insurance brokers are NOT authorized to issue this form. DB-120.1 (9-17) =IL fi � - WESTSH ® RE DESIGN ENGINEERS, P.C. F. COPY 1 100 GREAT OAKS BLVD. I SUITE 117A ALBANY I NEW YORK 12203 To: Kasselman Solar TOWN OF QUEENSBURY 20 Walker Way BUILDING DEPARTMENT Albany,NY 12205 Bayed on our limited examination,compliance M41 our comments shall not he construed as Date: September 22, 2021, indicating the plans and sppecifications are in full,compliance with the BUilding Codes of Ref.: 21090354 New York State. Subject: Etu Residence CEOWE 7 Amethyst Dr. OCT 1 8 2�2a Queensbury,NY P TOWN OF QUEENSBURY ! BUILDING& CODES To Whom It May Concern, — --...-- The following references the structural roof analysis of the Etu residence located in Queensbury, NY. Westshore Design Engineers has been retained in order to analyze the existing roof structure for adequacy in supporting the proposed additional loading due to rooftop solar panels. The site-specific loadings are as follows: Seismic Design Category C; basic Wind Speed of 115mph; and Ground Snow Load of 50psf, per ASCE 7-16. The Applicable codes also include the 2020 Residential Code of NYS. The existing roofs consist of pre-fabricated/engineered wood trusses at 24"o.c. Based on structural analysis the RI and R2 roofs are adequate to support rooftop solar panels with a maximum loading of 3psf. "Unirac" L-foot anchors or equal with 5/16" diameter lags required at 48" on center maximum, staggered,with 2.5"minimum embed or S-5! Clamps or equal for metal roofs. RoofTech"RT Mini" or equal attachments for deck attachments. Please don't hesitate to contact us with additional requests. Thank you. Westshore Design Engineers P`o�N S A./V A ti * 2 � TOWN OF QUEENSBURY 0724 af BUILDING & CODES DEPT. Reviewed B Date: FO 091373 pR�FES S10Np� 9/22/2021 John Eibert Nicolas Nitti,PE Director of Solar Operations President WestShore Design Engineers 1 100 Great Oaks Blvd.I Suite 117A I Albany,NY 12203 1518.313.7153 Customer: 1017/2021 Nathan Etu Address: 7 Amethyst Dr Queensbury,New York 12804 _ Phone: 12 Longi 350 W Modules (214)632-7952 12 Enphase IQ7+ Microinverters 31 Longi 350 W Modules 99 1WROMEX 31. Enphase IQ7+ Microinverters-ARCOMBINER System Size: 10.85 50A Main MSP 10 Longi 350 W Modules 125A Bus,. 200 A Main COMBINER 200 A Bus 10 Enphase IQ7+ Microinverters n6 ROMEX 20 A - 4I0 SEU 12l2 ROMEX A 99- AR - Utility: National Grid 9 Longl 350 t W Modules:-, Enphase Envoy Acctx 64076-20120 Monitoring System Meter# 27019104 9 Enphase IQ7+ Microinverters 12r2 ROMEX �jt ., Kassehnan Solar ` 279 Broadway Bldg.2 * ...kas,s,elm,anspaL-- Menands,NY 12204 518-320-7669 GRavND AccEss p ND ACCESS ;? a} a GR U ROUND ACGi^SS G ='. ;r a a'- S - - S .a• E C C C D N - C O - R - :!"r C E =} T R v - n - R / Y C - /M E E -" R ,r 4{ N ; ? ,d d rd' t�- ne Af - S P r A D �• f / S Q r. .P� N T' N E N - R O C - T R r'' W - A r" C �. R2 AV Y. kassel ; . . 'mans®cq� . . �'•� - R, , Natna rO ect and t QUe ns t�YSt pr Ysterp Si lion sbUrY,NY'2804 1 L017 la 0 4(k�HPo,B$alls;. e Ener 8 35OA4 UNIRgC Sp gy lnc,lQ T+ R CAR oof p October ft,' MOUNT MATERescri tiop 2p27 fA SNI tiMt,Ty pV design adheres IL:RAFTER@ Ri R2J�s1g arphOtOyoltai ��30 tD SOl RUSS: cre%vast REE fCT sections of the 2020 2zq•,2q"O.c. REES(81 Residential Codepho}o�Oltaic lR324J ofNy :Satb MDdula with asks in a and 2020 sections fiord Fire Code t2 p4 once ofNySl72041 ddge�ot e(lRC 2p20�ion 020� Design p Pareq b: not less than 36 ass n fig„pathway t re y Cody p er. eectrical tab ort Pe nt Placed 'Jar gn a label, Site 0 ui to Desi $Fn9lneerin9 Co°rdlnator attaCheasPe�fcN ab s�g56 abe s guide - y ~�, ice,+.�• sp - �� x r_ � l ' .. ,. 1 rr��� ���Y3J'. * .��"�..� �� 'tee � �i,tl�)h -• .er+Ef�'Xt��„�. •'R ti � �4�a,�,._�'zs'„� _ .tia. '"k'•.:.''L�- �..��_.:ti ;' v _,44G�, } JA �{ ■ "'S i 1 � I I e e I 308.14-1-28 SOLAR-0768-2021 Etu, Nathan 7 Amethyst Dr Solar Panel Install -- roof mount .. . . -0.5�®e® 25-year Power illillillillilllllmll Addition % Warranty Annual J xl 111111111 Illat Value from LO Power Attenuation 91.2% - NGi Solar's Li near ` St Wa 0 rranty .55/ 87.7% ` _ a andard Mor/ule lin >zr- 84.5% T ear powef�arrantx. 80.7% r s t z 1 5 10 15 20 25 Complete System and Product Certifications Positive power tolerance(0 +SW)guaranteed IEC 61215,IEC 61730,UL 61730 ISO 9001:2008:ISO Quality Management System High module conversion efficiency(up to 20.3%) ISO 14001:2004:ISO Environment Management system- _ Slower power degradation enabled by Low LID Mono PERC technology:first year<2%, T562941:Guideline for module design qualification and type approval 0.55%year 2-25 OHSA518001:2007 Occupational Health and Safety Solid PID resistance ensured by solar cell process optimization and careful module BOM Joeselection , , I s�• C El us Reduced resistive loss with lower operating current k specifications subject to technical changes and tests. Higher energy yield with lower operating temperature LONGi Solar reserves the right of interpretation. Reduced hot spot risk with optimized electrical design and lower operating current ■ C71 Room 801,Tower 3,Lujiazui Financial Plaza,No.826 Century Avenue,Pudong Shanghai,200120,China Tel:+86-21-80162606 E-mail:module@longi-silicon.com Facebook:wvnvfacebook.com/LONGi Solar Note:Due to continuous technical innovation,R&D and improvement,technical data above mentioned may be of modification accordingly.LONGi have the sole right to make such modification at anytime without further notice;Demanding party shall request for the latest datasheet for such as contract need,and make it a consisting and binding part of lawful documentation duly signed by both parties. `These Modules ate not offered,distributed or supplied to Germany by the LONGi Group. LONGi Solar Technclogle GmbH does not offer,distribute or supply those Modules in Germany or any other country. 20200401V11 LR4-6.0HPB 345' 370M Operating 1038 Cell Orientation:120(6x20) Operational Temperature:-40C^+85C Junction Box;IP68,three diodes Power OutputTolerance:0`+SW 1 �� 9 Output Cable:4mm2,300mm in length, Voc and IscTolerance:13% (� I� 9�>�J '^ length can be customized Maximum System Voltage:DC1000V(IEC/UL) ON 111 Glass:Singleglass Maximum Series Fuse Rating:20A t2 3.2mm coated tempered glass Nominal Operating Cell Temperature:45±2C n� Frame:Anodimdalurnhumalloyframe Safety Class:Class11 umtrmmMdd Weight19-S Fire Rating:UL type I or 2 Tole an e. Dimattsime 175S,d038x35mm Lmglh+firm' - " 997 Vdd0.±2mm Pader4;3' parpzt niknr.±7rt 1W sp&20GP AMl;tm aJr4D1iC Electrical Characteristics Test uncertaInty for Pmax, x• � v-:..�_,,..: ..� ,�.._,.r.�._ac.«5.,.., _..,.. r.,.�.,_.:+iNp..�. ... ;,.r. y,,,,. .*.S�y - _ - i'•>(Vlodet Number:;`; s ? �_ ' LR46DHF$345M -LR4¢0}1PE�3SON1 iR4-¢OMPB=�'s5M- LR4=60HPB-36pM ,LR4-60HP6-365[y!: LR4 60�3_P8 370M : t--= Testing Condition NOCf j SfC NOCT _ STC NOCT STC NOCT ' SfC NOCf=� STC NOCT j `Maw u Po er P � '`'� .o �„ 7_ _ �a; ; ,} • m to w (,It1aX/W},-� 345,,r 2576 }350r 2614 - 355 2fiS1 -' 360 268,& 365°_ 2Z2c6 370 -_� 27¢3, c Open Circuit Voltage(Voc/V) 40.2 4 377` l •40.4 37.9 -r=,^406 381. . 40.8 ' 38.2 410 384 41.2 t 38.6 Short-Ircurt Lurreht(ISc/A}- , �2 06= 8 95 1116 9 02 a 1125 �,9 O9 1133 9,16 1t 41; 9 28 11 SO__ 9 3D- Voltage at Maximum Power(Vmp/V) 34 2 318 j 34.4 32.0 34 6 332 `a 34.8 32.4 35 D _; 35.2 32.8E Current atMaximtinPower(lmp/A)r 1D09 809' 101& All 1027r+ 83 1035 =- &c3a 1043 836, 1052 843_j Module Efficiency(%) 18 9 19.2 19 5 19.8 :20 0 "d 20.3 STC(ftandard Testing Cortdltiops)irl ad66 SU00W/m' Ce117emperdture,25 C,Spectra 2t AM15 _ j NOCT(Nominal Operating Cejl Temperature):Irradiance 80OW/m2,Ambient Temperature 20 C,Spectra at AM1.5,Wind at 1m/S o Temperature Coefficient of Isc +0.0489/./C Front Side Maximum Static Loading 540OPa Temperature Coefficient of Voc -0.2709/o`/C Rear Side Maximum Static Loading 240OPa Temperature Coefficient of Pmax -0.350V./C Hailstone Test 25mm Hailstone at the speed of 23m/s IN Curve Current-Voltage Curve(LR4-60HPB-360M) Power-Voltage Curve(LR4-60HPB-360M) Current-Voltage Curve(LR4-60HPB-360M) 12 400 Cell temp-25C 12 Cell Temp•25C 10 350 —1o00w/m' 10 l000w/m mudent brad=t000w/m' 300 —fiwwim 80ow/m' g —Cell Temp=25 C 3 250 —4eew/m' g —Cell Temp'35C �. —200w/m' a 600w/m' 6 —Cell Temp=45C 3 200 6 —Cell Temp-55C u 4 —CeIITemP=65C a 150 U q 4oaw/m' —Cell Temp=75C 100 2 so 2 20ow/m' 0 0 0 0 30 20 30 40 s0 0 10 20 30 40 50 0 10 20 30 40 50 Voltage(v) Voltage Iv) Voltage(v) GI Room 801,Tower 3,Lujiazui Financial Plaza,No.826 Century Avenue,Pudong Shanghai,200120,China Tel:+86-21-80162606 E-mail:module@longi-silicon.com Facebook:wwwfacebook:com/LONGi Solar Note:Due to continuous technical innovation,R&D and improvement,technical data above mentioned may be of modification accordingly.LONGi have the sole right to make such modification at anytime without further notice;Demanding party shall request for the latest datasheet for such as contract need,and make It a consisting and binding part of lawful documentation duly signed by both parties. These Modules are not offered,dsftibuted or supplied to Germany by the LONGI.Group. 20200401V11 LONG!SolarTechnologie GmbH does not offer,distribute or supply those Modules In Germany or any other country. Data Sheet Enphase Microinverters Region:AMERICAS- Enphase The high-powered smart grid-ready Enphase IQ 7A Micro' dramatically simplifies the a Q:7A M Icrolnverter installation'process while achieving the highest system efficiency for'systems with 60-cell and 72-cell modules. Part of the Enphase IQ System,the IQ 7A Micro integrates with the Enphase IQ Envoy"; Enphase IQ Battery",and the Enphase Enlighten" monitoring and analysis software. The IQ Series Microinverters extend the,reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. High Power • Peak output power 366 VA @ 240 VAC and 295 VA @ 208 VAC Easy to Install • Lightweight and simple • Faster installation-with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) Efficient and Reliable ir • Optimized for high powered 60-cell and 72-cell modules • Highest CEC efficiency of 97% • More than a million hours of testing m Class If double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride- through requirements • Envoy and Internet connection required • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) To learn more about Enphase offerings,visit enphase.com `�j EN PH AS E• Enphase IQ 7A Microinverter INPUT(DC) IQ7A-72-2-US z Module compatibility 60-cell,66-cell,and 72-cell PV modules Power point tracking voltage range 2 18 V-58 V Max DC short circuit current(module ISC)3 15A OvervoltagecfassDCpo_rt DC port backfeed current 0 A didi Nb`;additi6halDC;si b--pr6tdctidnr Pv`-' ungrounded-enaTTY; -q -pi e,ACI ction-'require,s 7 b- -p dric ircu r rq e r' OUTPUT-(AC)--- @ 240-VAC @ 208 VAC k'outputfiowdr Maximum continuous output power 349 VA 290 VA Maximum continuous output current 1.45 A(240 VAC) 1.39 A(208 VAC) Extended frequency range 47-68 Hz WOO -iN Maximum units per 20 A(L-L)branch circuit' 11 (240 VAC) 11 (208 VAC) SLaoz-"7�"" AC port backfeed current 18 rnk Power factor(adjustable) 0.85 leading... 0.85 lagging EFFICIENCY @240 VAC @208VAC ZMIN 61��ji-f I fi c I p n c MECHANICAL -5- Relative humidity range 4%to 100%(condensing) Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) :Weight M& Cooling Natural convection-No fans 1-141-1pr"" W or-WeVlobdtldns-,-�'- Pollution degree PD3 Environmental category UV exposure rating NEMA Type 6 outdoor FEATURES Monitoring p Compatible with Enphase IQ Envoy ' LIL 62109-1,UL1741/IEEE1547,FCC Part 15 Class,'B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut'Dowin Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV.Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2.CEC peak powertracking voltage range is 38 V to 43 V. 3.Maximum continuous input DC current is 10.2A. 4.Voltage range can be extended beyond nominal if required by the utility. 5.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com @ 2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7A,Enphase IQ Battery Enphase Enlighten,Enphase IQ ENPHASE. Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change. 2020-06-16 SOLARMOUNT U N I RAC SOLARMOUNT.is the professionals' choice for residential PV mounting applications. Every aspect of'the system is--designed-for an easier, faster installation experience. SOLARMOUNTis.a complete solution with revolutionary universal clamps;FLASHKIT PRO,full system UL 2703 certification and 25-year warranty. Not only is SOLARMOUNT easy to install-,.but best-in-class aesthetics make it the most attractive on any block! 1 t' v 3: _ I 1 " Neuu' Im ro.ve` - - THE::PR•OFESSI.ONALS7'.0,H'OICE - ri - .f:::.a. •With:Su e or�Aest et csi- - 5 p. r ' _ :.;fin "":• ,NOW FEATURING FLASHKIT,PRO NOW WITH UNIVERSA'L�MIDCLAMPS REVOLUTIONARY NEWz MOCLAIVI • The Complete Roof Attach mentSolution Acdommodates 30mm--51mm module frames Concealed design and included End Caps FEATURING®SHED&SEAL TEcyeoiocv One tool,one-persontinstalls are here! THE PROFESSIONALS' CHOICE FOR RESIDENTIAL RACKING BEST INSTALLATION N ' EXPERIENCE ■ ■ 1 APPEAL COMPLETE SOLUTION 7 1 1 ' ■ ■ QUESTIONS ■ ' ■ SERVICE ■ 1 ■ N 13. ' kO$ t:'PO TE W S-r A ER StlPPL'Y`.° VfJ TAIC°SY.HC174_ L PANEL I�' SOt1t�CES'°i1TIliTY GRID ANtJ ,i 'p s COMBINER x -s.. — n PV'S4LAFt'ELECTRIC SYSTEM i DO NOT"ADD LOADS `y' J" LA rv�rto nat'�cur�tEsvTaPs rh THt3 SERVtC'E JE'TEF3 PY HUNG.GUI®E �2Ai EID�APF VOLTAGE vo�zs a 1$ALSO SERVEDY A " "�'""`°�"'°"` a> n� `°', t ,PHO'iOVCiLTAIC SYSTEM ,t' .7,a.g612L',•:P1/DC•DISCtaNINE&bRERATiNG.SPEC,PI:ACE i,l?ER, neollC5YS1FMVQITAGE WC 1 w IN?JERTER., w W 2: iNARNING,LA6 CE 1 PEItiNVERiER,AND .DC; ., } ~ 3.:WArRN9NG`IABEL;DG;'.PCACE1 EVERY"Ibl'OF CQ[�6DUIT, LECTRIC SHOCK HAZARQ n-' REFLEGTIV E. . BEL,iND[CATING PV HAS,RAPID SFiUTDOWN,PLACE 1"OfV DC3t10iTQUCHTFfiMtNALS 8 / �l _ _..,... .-., ... SERMINAlS Otd BOSH SHE L1NE'AND` -- -- METER;,REFLECTIVE. '",LOAD81f1ESMAYB;EENI:RGIZED� ,,•---;. .,., :." .� ti_:.. :. "'`f iNttieoPENFos�sioiv4 ; S.; AS" INDICATINia.AAIN,BREAKER HAS— EEN;D01A4PNSIZED,, P,LiACE 1.NEAR MAIN. b :NtARNtNG L11BEl;iND►G�'tlt�lG-YNETER;IS:BACK.F,ED BY'PV, y r ■ j ry Gu _ s I°L'ed►CE!:'V Oft METER; ,., 7i4BfL:fND{C/'bTING WQiERE;P1la�iSCO1NECi`IS'..:. ® i _ .. .. .... .. _ _,... _a ATED,PLACE i ON MEiER',VERAGE V ARIE,S. .P.ER;SITE. PROMVOLT . ;' g:L 'SEL`I'NpICAtINC'PV 1�1SCONNECT •PLI CE 1 ANY1fVHERE PV. 7 URN Oar`PHK37L}V6L,it It; ; . .- 1 f tAG DIS+COPINECT PRIOR 70 = " CAN'BI:IDISCPMNECTED :REFEEeilVE., - .-:.,.. "EQUIPPED y � µ 9:-1ABEL JIND G ICATINPV Or/ER'CURENT DEVICE:P!'�4CE.1 I!lEAEs,ALt':PVI BREKiiS_EXCEPT'MAI[V. iG:WARNING tAf3EL" AC,PLACE l PER;AC:!UNCTION,BOX, 'COMBINER'"EL.VSCONN91 T%AkL ELECTRICAt:LOAD R GEI!lTERS ' LABEL,"P1f AC DISCONI`fEGi OPERAikNG SPEC,Pd.ACE!:,AT W I NOlyil1VE11 OPERATINGACYOLiAGE t E ` �i4 L'LOGATIC}NS PV,AC C NNECTED: I!,wARNING k"Si d'..Pf;f, E4-_'0�@.t6MBINER PANEL,, � DiSCbNNECTi•OR TAP..LOCAiION. i3 :WJ4RNlIVG;f ABEI,. IACE.1,�Pl j COMBINER Pi4NEL. . i6ELS.ARE-SIiE`SPECIFIC.