Loading...
ApplicationArea Variance Pre-Submission Conference Form / Section 179-9-040 1. Applicant Name: __________________________________________________ 2. Tax Map ID ________________Location:_______________________ 3. Zoning Classification __________ 4. Reason for Review: __________________________________________________________ 5. Zoning Section #: ________________________ 6. Pre-Submission Meeting Notes: Provided Outstanding; Please provide by Deed ____ _____________ General Information complete ____ _____________ Site Development Data Complete ____ _____________ Setback Requirements Complete ____ _____________ Additional Project Information Complete ____ _____________ FAR addressed ____ _____________ Compliance with Zoning Ordinance ____ _____________ Checklist items addressed ____ _____________ Environmental Form completed ____ _____________ Signature Page completed ____ _____________ Staff Representative: ________________________________ Applicant / Agent: ________________________________ Date: ___________ Page 6 Justin Mootz 290.-1-69 15 Brookfield Run MDR & Subdivision second garage 1,296 sq ft 179-3-040 district, 179-5-020 garage X X X NA NA X X correct height and setbacks SUB11-1987 Brookfield Estates Phase II X section 179-3-040 and 179-5-020 X - septic and well? on plan or indicate on site/municipal Laura Moore via email 10/13/2021 Applicant proposes to construct a two bay 1,296 sq ft detached garage. The project includes removal of 160 sq ft shed and removal of 313 sq ft hard -surfacing. The new garage is to be 15 ft from the side property line where a 10 ft minimum is require per the subdivision. A detached garage is limited to 1,100 sq ft on lots less than 5 acres. The new garage is also proposed as the second garage where only one garage is allowed per parcel. The garage is to be 22 ft 9 inches and appear to have a half story. Project requires a variance for second garage and size of garage. Items reviewed - area variance application, elevations, survey, deed Items to be updated 1) page 2 Setbacks - correct height - plans show 22 ft 9 inches, setbacks -project is in a subdivision where side setbacks are 10 ft minimum 30 ft sum - side setback relief is not required. 2)page 3 - previous approvals -Subdivision 11-1987 Brookfield Estates Phase II SR20 3) page 4 update section with 179-3-040 - district and 179-5-020 garages. Also, far information not applicable as mdr/sr20 require far details. 4) page 5 - missing floor plans for main garage floor and half story -what is size of half story, what is it used for, how is it accessed; will need information on septic location; confirm no bathroom in 2nd garage. 9'-0"Undistrubed SoilFront ElevationA-21Scale: Right ElevationA-23Scale: PlansGarage Project A-1 Address:Date:Drawn by:Mar 17, 2021Approved by:New 2"x6" Nominal Wall Construction(TYP)First Floor Plan A-11Upper Storage Floor PlanA-12BA-1UPDownOpen Garage DoorArea Above1'-0"SLB:15 Brookfield RunQueensbury, NY 128041024 Sq Ft grossFoundation PlanA-31Finish Grade to SlopeAway From SlabTypical SectionA-1B8"W x 48"Deep PouredCement Frost Wall /Knee WallWood FramedWalls. 9' Precutupright Studs. 2X6Top and BottomPlatesEngineeredTrusses by Others23/ 32 4x8Sturdifoor T&G FIRPlywood9'-0"9'-0"5'-6"5'-6"3'-0"32'-0" 1'-0"3'-0"3'-0"9'-0"1'-0"14 "=1'-0"Scale: 14 "=1'-0"Scale: 14 "=1'-0"Scale: 14 " = 1'-0"Scale: 14 "=1'-0"1 4 " = 1'-0"4 Foot Deep Frost wall N.T.S.Typical Section For WallsA-1Detail 1GradeDetail 1A-13'-0"3'-0"Update:Nov. 2, 20213'-0" 6'-8" Job B211248 Truss 32ATST Truss Type ATTIC Qty 1 Ply 1 32' RIA Job Reference (optional) Run: 8.430 s Feb 3 2021 Print: 8.430 s Feb 3 2021 MiTek Industries, Inc. Tue Nov 2 09:04:34 2021 Page 1 Harvest Homes Inc., Delanson, New York 12053 ID:jboGCMYa6VBOM8EMB4rhDzzpqOx-zFht3ADjbVBr?Xy1rqs?VDc_v?rLPofGLwqM6pyNIKR Scale = 1:67.0 B1 T2 T3 W2 W5 W1 W6 W4 B3 T1 T4 W3 B212 3 4 5 6 7 8 9 10 11 12 13 15 14 16 4x8 4x8 5x5 4x8 8x16 MT18HS 2x4 8x16 MT18HS 2x4 2x3 2x3 2x4 4x8 3x5 3x5 20-5-3 11-6-011-10-107-0-125-3-11 5-3-11 10-1-4 4-9-9 21-10-12 11-9-8 26-8-5 4-9-9 32-0-0 5-3-11 -1-0-0 1-0-0 5-3-11 5-3-11 10-1-4 4-9-9 10-10-2 0-8-14 16-0-0 5-1-14 21-1-14 5-1-14 21-10-12 0-8-14 26-8-5 4-9-9 32-0-0 5-3-11 33-0-0 1-0-0 0-6-1411-2-140-6-148.00 12 Designed for residential storage area Uninhabitable application utilized - 30 lbs. / sq. ft Plate Offsets (X,Y)-- [2:0-8-0,0-1-2], [12:0-8-0,0-1-2], [14:0-4-8,Edge], [15:0-4-8,Edge] LOADING (psf) TCLL (Ground Snow=60.0) TCDL BCLL BCDL 46.2 10.0 0.0 10.0 SPACING- Plate Grip DOL Lumber DOL Rep Stress Incr Code 2-0-0 1.15 1.15 YES IRC2018/TPI2014 CSI. TC BC WB Matrix-MS 0.70 0.66 0.56 DEFL. Vert(LL) Vert(CT) Horz(CT) Attic in -0.42 -0.65 0.06 -0.36 (loc) 14-15 14-15 12 14-15 l/defl >905 >590 n/a 409 L/d 360 240 n/a 360 PLATES MT20 MT18HS Weight: 209 lb FT = 20% GRIP 169/123 169/123 LUMBER- TOP CHORD 2x6 SP No.2 BOT CHORD 2x6 SP DSS WEBS 2x4 SPF-S Stud *Except* W3: 2x4 SPF 1650F 1.5E BRACING- TOP CHORD Structural wood sheathing directly applied or 3-1-1 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 16 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS.(lb/size) 2=2304/0-5-8 (min. 0-3-10), 12=2304/0-5-8 (min. 0-3-10) Max Horz2=-296(LC 6) Max Uplift2=-212(LC 8), 12=-212(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3453/262, 3-4=-3074/240, 4-5=-2888/247, 5-6=-2280/297, 6-7=-532/140, 7-8=-532/141, 8-9=-2280/297, 9-10=-2887/246, 10-11=-3073/240, 11-12=-3454/263 BOT CHORD 2-15=-329/3003, 14-15=-87/2441, 12-14=-130/2782 WEBS 5-15=0/958, 9-14=0/958, 3-15=-655/301, 11-14=-656/302, 6-16=-2188/222, 8-16=-2188/222 NOTES- 1) Wind: ASCE 7-16; Vult=115mph (3-second gust) Vasd=91mph; TCDL=5.0psf; BCDL=5.0psf; h=25ft; Cat. II; Exp C; Enclosed; MWFRS (envelope) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33 2) TCLL: ASCE 7-16; Pg= 60.0 psf; Pf=46.2 psf (Lum DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat C; Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10 3) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 46.2 psf on overhangs non-concurrent with other live loads. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) Bottom chord live load (30.0 psf) and additional bottom chord dead load (6.0 psf) applied only to room. 14-15 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 212 lb uplift at joint 2 and 212 lb uplift at joint 12. 8) This truss is designed in accordance with the 2018 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 9) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE. LOAD CASE(S) Standard