Loading...
CC-0034-2021 Office Use Only ADDITION/ALTERATION PERMIT Permit#:_CC-0034-2021 Town of Quccnsbury APPLICATION Permit Fee:$N/A 742 Bay Road,Queensbury,NY 12804 Invoice#: P:518-761-8256 -www.gueensbury.net Flood Zone? Y N Reviewed By: Project Location: 170 Carey Rd Tax Map ID#: 309.13-2-31.113 .Subdivision Name: PROJECT INFORMATION: TYPE: ❑ Residential N Commercial, Proposed Use.Adirondack.Radiology ❑ Single-Family ❑ Two-Family ❑ Mu,lti-Family (#of units ) El Townhouse ❑ Business Office ❑ Retail ❑ Industrial/Warehouse ❑ Garage (#of cars ) N Other (describe Medical Office) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 2nd floor: 2nd floor: 3rd floor: 3rd floor: Basement (habitable space): Basement (habitable space): Total square feet: Total square feet: to 2-06 Scope of work to be done:Tenant fit-up for Adirondack Radiology C E VIE FEB 10 .2021 TOWN OF QUEENSBURY BUILDING&CODES Addition/Alteration Application Revised January 2021 9 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 1,400,000.00 2. Source of Heat (circle one): 0 Gas ❑ Oil ❑ Propane ❑ Solar ❑ Other Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? ❑ YES 0 NO Explain: 4. Are there any easements on the property? ❑ YES 0 NO SITE INFORMATION: • Is this a corner lot? 0 YES ❑ NO • Will the grade be changed as a result of the construction? ❑ YES ❑ NO • What is the water source? 0 PUBLIC ❑ PRIVATE WELL • What type of wastewater system is on the parcel? 0 SEWER ❑ PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans, additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Kevin Knobloch SIGNATURE: Kevin J Knobloch DATE: 2-8-21 Addition/Alteration Application Revised January 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Bonacio Construction, Inc. Mailing.Address, C/S/Z: 19 Division St, Saratoga Springs,NY 12866 Cell Phone: Land Line: Email: • Primary Owner(s): Name(s): Mailing Address, C/S/Z: Cell Phone: Land Line: Email: ❑ Check if all work will be performed by property owner only • "Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): Bonacio Construction, Inc. Contractor Trade: 19 Division Si, Saratoga Springs_,NY 12866 Mailing Address, C/S/Z: Cell Phone: Land Line: Email: kevink@bonacio.com "Workers' Comp documentation must be submitted with this application" • Arch itect(WEngineer(s): Business Name: Hyman Hayes Associates Contact Name(s): Rabia Shinaishin Mailing Address, C/S/Z: 6 Wembley Ct 4:,. Cell Phone: Land Line: Email: rshinaishin@hymanhayes:com Contact Person for Compliance in regards to this project:Kevin Knobloch Cell Phone: Land Line: Email: kevink@bonacio.com Addition/Alteration Application Revised January 2021 COMcheck Software Version 4.1.5.1 Envelope Compliance Certificate pECEUVE Project Information Energy Code: 2018 IECC JAN 2 2021 Project Title: Carey Road Medical Office Building ']'O OF Location: Glens Falls,New York QUEENSBURY Climate Zone: 6a BUILDING&CODES Project Type: New Construction Vertical Glazing/Wall Area: 11% Construction Site: Owner/Agent: Designer/Contractor: 142 Carey Road Larry Novik Myles Hyman Queensbury, NY 12804 Bonacio Construction, Inc Hyman Hayes Associates 18 Division Street,Suite 401 6 Wembley Court Saratoga Springs, NY 12866 Albany, NY 12205 (518)584-9007 518-452-3470 larry@bonacio.com MHyman@hymanhayes.com Additional Efficiency Package(s) . Enhanced Interior Lighting Controls REVIEWED FOR Building Area FlocEMBRGY CODE COMPLIANCE 1-Slab(Office):Nonresidential 15002 Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U- _ or R-Value R-Value U-Factor Factorp) Perimeter Floor 1:Slab-On-Grade:Unheated,Vertical 4 ft.,[Bldg.Use 1-Slab](c) 526 — 10.0 0.480 0.540 Roof 1:Insulation Entirely Above Deck,[Bldg.Use 1-Slab] 15002 — - 30.0 0.032 0.032 NORTH Exterior Wall-North 2"Cl(EIFS):Wood-Framed,16"o.c.,[Bldg.Use 1 1318 14.0 8.0 0.049 0.051 -Slab] Windows Aluminum Frame North:Metal Frame with Thermal 72 — — 0.368 0.360 Break:Fixed,Perf.Specs.:NFRC CPD-ID P-KAW-5641,SHGC 0.34, VT 0.62,[Bldg.Use 1 -Slab] Exterior Wall-North 1"Cl:Wood-Framed,16"o.c.,[Bldg.Use-1-Slab] 1323 14.0 5.0 0.058 0.051 { Alumnium Storefront North:Metal Frame with Thermal Break:Fixed, 418 — — 0.368 0.360 Pert.Specs.:NFRC CPD-ID P-KAW-5641,SHGC 0.34,VT 0.62,[Bldg. Use 1 -Slab] Entry Door:Glass(>50%glazing):Metal Frame,Entrance Door,Perf. 42 — -- 0.380 0.770 Specs.:Product ID 8,SHGC 0.40,VT 0.62,[Bldg.Use 1-Slab](b) EAST Exterior Wall-East 2"Cl(EIFS):Wood-Framed,16"o.c.,'[Bldg.Use 1- 1693 14.0 8.0 0.049 0.051 Slab] Windows Aluminum Frame East:Metal Frame with Thermal 94 -- -- 0.368 0.360 Break:Fixed,Perf.Specs.:NFRC CPD-ID P-KAW-5641,SHGC 0.34, VT 0.62,[Bldg.Use 1-.Slab] Exterior Wall East 1"Cl:Wood-Framed,16"o.c.,[Bldg.Use 1 -Slab] 484 14.0 5.0 0.058 0.051 SOUTH Project Title: Carey Road Medical Office Building Report date: 01/25/21 Data filename: ZAActive Projects\Adirondack Radiology Associates\18060-Adirondack Imaging Glens Falls\Prc Page 1 of 10 Info\10-Code Review\Carey Road MOB with MEP ComCheck 2020-11-2.cck Assembly Gross Area Cavity Cont. Proposed Budget U- or R Value R-Value U-Factor Factor(.) Perimeter Exterior Wall—South 2"Cl(EIFS):Wood-Framed,16"o.c.,[Bldg.Use 1 1875 14.0 8.0 0.049 0.051 -Slab] Windows Aluminum Frame.South:Metal Frame with Thermal 92 — — 0.368 0.360 Break:Fixed,Perf.Specs.:NFRC CPD-ID P-KAW-5641,SHGC 0.34, VT 0.62,[Bldg.Use 1-Slab] Staff Door-4'x7':Insulated Metal,Swinging,[Bldg.Use 1 -Slab] 28 -- -- 0.410 0.370 Staff Door-Tx7%Insulated Metal,Swinging,[Bldg.Use 1 -Slab] 21 — -- 0.410 0.370 Exterior Wall-South 1"Cl:Wood-Framed,16"o.c.,[Bldg.Use 1-Slab] 671 14.0 5.0 0.058 0.051 WEST Exterior Wall-West 2"Cl(EIFS):Wood-Framed,16"o.c.,[Bldg.Use 1 589 14.0 8.0 0.049 0.051 -Slab] Aluminum Frame:Metal Frame with Thermal Break:Fixed,Perf.Specs.: 34 — — 0.368 0.360 NFRC CPD-ID P-KAW-5641,SHGC 0.34,VT 0.62,[Bldg.Use 1 -Slab] Exterior Wall-West 1"Cl:Wood-Framed,16"o.c.,[Bldg.Use 1-Slab] 984 14.0 5.0 0.058 0.051 Alluminum Storefront West:Metal Frame with Thermal Break:Fixed, 214 -- -- 0.368 0.360 Perf.Specs.:NFRC CPD-ID P-KAW-5641,SHGC 0.34,VT 0.62,[Bldg. Use 1 -Slab] (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. (b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope Compliance Statement Compliance Statement. The proposed envelope design represented in this document is consistent with the building-plans, specifications, and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.1 and.to comply with any applicable mandatory requirements listed in the Inspection Checklist. Rabia Shinaishin, Senior Associate 1/25/2021 Name-Title Signature Date Project Title: Carey Road Medical Office Building Report date: 01/25/21 Data filename: Z:\Active Projects\Adirondack Radiology Associates\18060-Adirondack Imaging Glens Falls\Prc Page 2 of 10 Info\10-Code Review\Carey Road MOB with MEP ComCheck 2020-11-2.cck t COMcheck Software Version 4.1.4.1 Interior Lighting Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Carey Road Medical Office Building Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: t 142 Carey Road Larry Novik Myles Hyman Queensbury, NY 12804 Bonacio Construction, Inc'— Hyman Hayes Associates 18 Division Street,Suite 401 6 Wembley Court Saratoga Springs, NY 12866 Albany, NY 12205 (518) 584-9007 518-452-3470 larry@bonacio.com MHyman@hymanhayes.com Additional Efficiency Package(s) Enhanced Interior Lighting Controls Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Slab(Office) 15002 0.79 11852 Total Allowed Watts= 11852 Proposed Interior Lighting Power A B C D E Fixture ID :Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-Slab(Office) LED 1:Li:Architecural Panel:LED Other Fixture Unit 90W: 1 3 90 270 LED 2:L2:Architectural Troffer:LED Other Fixture Unit 36W: 1 118 39 4602 LED 3:L&Prismatic Troffer:LED Other Fixture Unit 50W: 1 21 52 1092 LED 4:L4:6"down light:LED PAR 15W: 1 47 15 705 LED 6:L6:Decorative Pendant:LED MR 4W: 1 1 4 4 LED 7:L7:Strip Light:LED Other Fixture Unit 28W: 1 5 31 155 LED 8:L8:Decorative Pendant:LED PAR 15W: 1 9 15 135 LED 9:L9:Linear Slot:LED Other Fixture Unit 25W: 1 32 20 640 LED 10:L10:Linear Cove light:LED Other Fixture Unit 13W: 1 25 10 250 LED 11:Ll 1:Architectural troffer:LED Other Fixture Unit 36W: 1 12 33 396 LED 12:L12:Downlight:LED PAR 15W: 1 8 15 120 LED 13:L13:Down light:LED PAR 20W: 1 12 20 240 LED 17:L17:Decorative sconce:LED Other Fixture Unit 25W: 1 1 25 25 Total Proposed Watts= 8634 Project Title: Carey Road Medical Office Building Report date: 09/16/20 Data filename: MA2018\18096—Adirondack Radiology QueensburyX02-Design\00-Schematic\Carey Road MC Page 1 of 28 ComCheck.cck !I LightingInterior •A •- code Interior Lighting Compliance Statement Comp/lance Statement: The proposed interior,lighting design represented In this document is consistent with the building plans, specifications,and other calculations submitted-with this permit application.The proposed interior lighting systems have been designed to meet the 2018 IECC requirements In COMcheck ZVersIoq4.31:.4.;1, nd to comply with any applicable mandatory requirements listed in the Inspection Checklist.Pam. yE9, 15 -- ?0 Name-Title Slgna u Date Project Title: Carey Road Medical Office Building Report date: 09/16/20 Data.filename: M:\2018\18096-Adirondack Radiology Queensbury\02-Design\00-Schematic\Carey Road MC Page 2 of 28 ComCheck.cck I COMcheck Software Version 4.1.4.1 Exterior Lighting Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Carey Road Medical Office Building Project Type: New Construction Exterior Lighting zone 2(Neighborhood business district) Construction Site: Owner/Agent: Designer/Contractor: 142 Carey Road Larry Novik Myles Hyman Queensbury,NY 12804 Bonacio Construction,Inc Hyman Hayes Associates 18 Division Street,Suite 401 6 Wembley Court Saratoga Springs,NY 12866 Albany, NY 12205 (516)584-9007 518-452-3470 larry@bonacio.com MHyman@hymanhayes:com Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/Unit Wattage (B X C) Parking area 35000 ft2 0.04 Yes 1400 Driveway 3000 ft2 0.04 Yes 120 Entry canopy 280 1`12 0.25 Yes 70 Total Tradable Watts(a)= 1590 Total Allowed Watts= 1590 Total Allowed Supplemental Watts(b)= 400 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 400 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B G D E Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Parking area(35000 f12):Tradable Wattage LED 15:L15:Parking lot light:LED Roadway-Parking Unit 22OW: 1 7 219 1533 Driveway(3000 ft2):Tradable Wattage LED 15:L15:Parking lot light:LED Roadway-Parking Unit 220W: 1 1 219 219 Entry canopy(280 ft2):Tradable Wattage LED 14:LED PAR 20W: 1 6 20 120 Totat Tradable Proposed Watts= 1872 Exterior Lighting PASSES: Design 6% better than cod6 Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet:the 2018.IECC requirenienis in COMcheck Version 4.1.4.1 to,compiy with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title r 51gn ure Date Project Title: Carey Road Medical Office Building. Report date: 09/16/20 Data filename: M:\2018\18096-Adirondack Radiology Queensbury\02-Design\00-Schematic\Carey Road MC Page 3 of 28 ComCheck.cck COMcheck Software Version 4.1.4.1 Mechanical Compliance Certificate Project Information Energy Code: 2018 IE.CC Project Title: Carey Road Medical Office Building Location: Glens Falls,New York Climate Zone: 6a Project Type: New Construction I R Construction Site: Owner/Agent: Designer/Contractor. 142 Carey Road Larry Novik Myles Hyman Queensbury,NY 12804- Bonacio Construction,Inc Hyman Hayes Associates 19 Division Street,Suite.401 6 Wembley Court Saratoga Springs,NY 12866 Albany,NY 12205 (518)584-9007 518-452-3470 larry@bonacio.com MHyman@hymanhayes.com Additional Efficiency Package(s) Enhanced Interior Lighting Controls Mechanical Systems List Quantity System Type&Description 1 HVAC System 1 (Multiple-Zone): Heating:1 each-Central Furnace,Gas,Capacity.=64 kBtu/h Proposed Efficiency 80.00%Et,Required Efficiency: 80.00%Et or 80%AFUE Cooling:1 each-Single Package DX Unit,Capacity=70 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=11.3o'EER,Required Efficiency: 11.00 EER +12.6 IEER Fan System: RTU-1 supply—Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Multi-Zone VAV,1850 CFM,4.0 motor nameplate hp,90.0 fan,efficiency grade 1 HVAC System 2(Multiple-Zone): Heating:1 each-Central Furnace,Gas,Capacity=64 kBtu/h Proposed Efficiency=80.00%Et,Required Efficiency:80.00%Et or 80%AFUE Cooling:I each-Single Package DX Unit,Capacity=70 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=11.30 EER,Required Efficiency: 11.00 EER +12.6 IEER Fan System: RTU-2 Supply--Compliance(Motor nameplate HP method):Passes Fans: FAN 3 Supply,Multi-Zone VAV,2500 CFM,4.0 motor nameplate hp,90.0 fan efficiency grade 1 HVAC System 3(Single Zone): Heating:I each-Central Furnace,Gas,-Capacity=160 kBtu/h Proposed Efficiency=80.06%Et,Required Efficiency: 80.00 Et or 80%AFUE Cooling:1 each-Single,Package-DX Unit,Capacity=69 kBlu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=14.00 EER,Required Efficiency: 11.00 EER +12.6 IEER Fan System: RTU-3 supply--Compliance(Motor nameplate HP method):Passes Fans: FAN 2 Supply,Single-Zone VAV,2050 CFM,1.3 motor nameplate hp,90.0 fan efficiency grade 1 HVAC System 4(Multiple-Zone): Heating:1 each-Central Furnace,Gas,Capacity=160 kBtu/h Proposed Efficiency=80.00%Et,Required Efficiency: 80.06%Et or 80%AFUE Cooling:1 each-Single Package DX Unit,Capacity=139 kBtuft Air-Cooled Condenser,Air Economizer Proposed Efficiency=11.20 EER,Required Efficiency: 10.80 EER +12.2 IEER Fan System: RTU-4 supply--Compliance(Motor nameplate HP method):Passes. Project Title: Carey Road Medical Office Building Report date: 09/16/20 Data_filename: MA2018\18096-Adirondack Radiology Queensbury\02-Design\00-Schematic\Carey Road-MC Page 4 of 28 ComCheck.cck Quantity System Type&Description Fans: FAN 4 Supply,Multi-Zone VAV,3300 CFM,4.0 motor nameplate hp,90.0 fan efficiency grade t HVAC System 5(Single Zone): Heating:I each-Central Furnace,Gas,Capacity=160 kBtu/h Proposed Efficiency=80.00%Et,Required Efficiency: 80.00%Et br 80%AFUE Cooling:I each-Split System,Capacity=139 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=11.20 EER,Required Efficiency: 10.80 EER +12.2 IEER Fan System: RTU-5 &6 supply--Compliance(Motor nameplate HP method):Passes Fans: FAN 5 Supply,Single-Zone VAV,2500 CFM,4.0 motor nameplate hp,90.0 fan efficiency grade 1 HVAC System 6(Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=160 kBtu/h Proposed Efficiency=80.00%Et,Required Efficiency: 80.00%Et or 80%AFUE Cooling:l each-Single Package DX Unit,Capacity=139 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=11.20 EER,Required Efficiency: 10.80 EER +12.2 IEER Fan System: RTU-5 &6 supply--Compliance(Motor nameplate HP method):Passes Fans: FAN 5 Supply,Single-Zone VAV,2500 CFM,4.0 motor nameplate hp,90.0 fan efficiency grade 1 Plant 1: Heating:Hot Water Boiler,Capacity 199 kBtu/h,Gas Proposed Efficiency:96.00%AFUE,Required Efficiency:80.00%AFUE Mechanical Compliance Statement Compliance Statement~ The proposed mechanical design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed'mechanical systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.4.1 qpdto comply with any applicable mandatory requirements listed In the Inspection Checklist. Name-Title Sign re Date Project Title: Carey Road Medical Office Building Report date: 09/16/20 Data filename:'MA2018\18096-Adirondack Radiology Queensbury\02-Design\00-Schematic\Carey Road MC Page 5 of 28 ComCheck.cck Chad Stevens From: Kevin Knobloch Sent: Thursday, May 20, 2021 7:48 AM To: Chad Stevens Subject: FW: Required for Town of Queensbury OLE Copy From:Tom Bethon<bethon@albanymechanical.com> Sent:Thursday, May 20, 20216:33 AM To: Kevin Knobloch<kevink@bonacio.com> Cc:Chad Stevens<chads@bonacio.com> Subject: RE: Required for Town of Queensbury Kevin The Third party company who Will be completing the Air Balancing report for the Carey Rd. project will be the following. Northeaster Air Quality, Inc. P.O. Box 3271 Albany, NY 12203 Thomas Bethon President ��GKANICq�SF Q L I � 15 Albany A venue Green Island,NY 12183 Phone:(518)273 5541 Fax;(518)273 3597 Email:bethon@a]bMmechanical.com DISCLAIMER:CONFIDENTIALITY NOTICE TO RECIPIENT This email(including attachments)is covered by the Electronic Communications Privacy Act, 18 U.S.C.§§2510-2521,is confidential and may be legally privileged(including,without limitation,attorney-client privilege). If you are not the intended recipient,you are hereby notified that any retention,dissemination,distribution or copying of this communication is strictly prohibited. If you have received this message in error,please notify the sender,and delete it immediately. From: Kevin Knobloch [mailto:kevink@bonacio.coml Sent:Thursday, May 20, 20215:48 AM 1 To:Tom Bethon<bethon@albanVmechanical.com> Cc:Chad Stevens<chads@bonacio.com>; Kevin Knobloch<kevink@bonacio.com> Subject: Required for Town of Queensbury Tom Please answer the following for the Town of Queensbury Building permit. A. Provide name of company who will perform and submit report for-hvac air balancing. Kevin Knobloch I Project Mtan3ger Office: (518)584-9007 ext.227 { Ceii: (518)415-9166 Bonaci® Construction, Inc. 18 Division St I Suite 401 1 Saratoga Springs, NY 12866 www.bonacio.com ( facebook I instagram I twitter 2 FIRE MARSHAL'S OFFICE Town of Queensbury 742 Say Road, Queensbury, NY 12804 " Home of Natural Beauty ... A Good Place to Lice " PLAN REVIEW FILE COPY Carey Road Medical Offices 170 Carey Road CC-OOXX-2021 - 1/27/2021 15,000sf Fit Up Plans The following comments are based on a review of submittals: • Knox Box for FD entry required, minimum Model 3200 • Truss ID will be required • Verify Fire extinguisher locations • Clearly label all breakers for testing of exit/ emergency lighting fixtures • Locks /Latches to comply with Chapter 10 of IFC. No key locks or thumb turns • Exit and emergency lighting appears compliant. A witness function test will be required. • Exterior emergency lighting required at all doors • Submit complete sprinkler system layout, including hydraulic calcs. In addition, the following requirements_must be met: - FDC shall be 5" storz - Install FFS over FDC, to be active on all fire alarms - NFPA 13 letter of compliance required • Submit complete fire alarm system layout, including the following: - System layout drawing with riser diagram - CO detection - IVS over FDC - Spec. sheets for all equipment and appliances - NFPA 72 completion report - NFPA 72 inspection and testing report - FM witness test of system R r e M a r s It a l 's Off i.c e - P ly o n e: 518-761-8206 - F a x: 518-745-4437 'rentarshalftteensbui�Lnet a Tipu queensbunt.net s r� mil Michael J Palmer Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.net RYe MarsItaf 's Office a PItoite: 518-761-82,0E Fax: 518-745-4437 �temrzf•sJuti�t�icee�tsbctr•t�.r2et zr�zt�zv.c�zzeet�si'uraiaiet