Loading...
2003-181 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERLU'rLIFICATE OF OCCUP-A-N- CY hermit.Number: P20030181 Date_Issued:- Monday, March 28, 2005- _= This°is to-certify-that work requested,to=be done as shown b Permit Number q _ y- _a P200.30'181 has been completed.. Tax'Map Number: 523400-239-017-0001-007-000-0000 Location: 23 ANTIGUA Rd Owner: ROBERT WALL Applicant: ROBERT WALL This structure may be occupied as a: By Order of Town Board Garage - 3 Cars Attached TOWN OF QUEENSBURY Single Family Dwelling Director of Building&Code Enforcement y TOWN OF Q:UEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building 8i Codes (518)761-8256 BUILDING PERMIT Permit Number: P20030181 Application Number: A20030181 Tax Map No: 523400-239-017-0001-007-000-0000 Permission is hereby granted to: ROBF,RT WALL, For property located at: 23 ANTIGUA Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Buiiding;Codes and the Queensbury Zoning Ordinance. Twe of Construction Value Owner Address: DONALD &LYNN KING C/O DONALD KING Garage-3 Cars Attached Single Family Dwelling $180,000..00 23 ANTIGUA Rd Total Value $180,000.00 LAKE GEORGE,NY 12845 Contractor or Builder's Name/Address Electrical Inspection Agency HOWLAND CONSTRUCTION.INC. ATLANTIC-INLAND INC 793-6907 997 MCCLF,AN Rd 28 H1 TNTF,R LANF, 017FF,NSBURY.NY 12904-0000 CORTLAND.NY 13045 Plans&Specifications 2003-181 853 SQ FT SINGLE FAMILY DWELLING WITH 3-CAR ATTACHED GARAGE AS PER PLOT PLAN SPECIFICATIONS $191.96 PERMIT FEE PAID-THIS PERMIT EXPIRES:.:, Friday,May 07,2004 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at a To of a ury nesday,May 07,2003 SIGNED BY for the Town of Queensbury. Director'of Building&Code Enforcement ENERGY CODE COMPLIANCE APPLICATION I TOWN OF QUEENSBURY, WARREN COUNTY 9000 HEATING DEGREE DAYS Compliance Methods:Part 5 -Acceptable Practice Method—1&2 Family Dwellings(only) RECEIVED Part 6*- Thermal Rating—Component trade Offs 1&2 Family Dwelling; APR 17 2003 Multi-Family Dwellings(3 Stories or less) Part 4*-Design by Component Performance, Commercial Buildings-H;q'oWN OF QUEENSBuRy Rise Residential _I=Bl11LQINq APl®CODE *Requires submission of worksheets APPLICANT'S NAME: PROPERTY LOCATION: PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE: 1. Gross Floor Area- square feet 2. Type of heat- Electric Oil Gas X Other 3. Is building mechanically cooled? yes X No 4. Percentage of area of windows and doors Over 17% X Under 17% 5. R-VALUES FOR INSULATION GIVEN BEE OW MUST CORRESPOND TO R VALUES AS , SHOWN ON PLANS SUBMITTED: a: Roof - R j4R b. Exterior walls R 2/ C. Glazed areas R Zg§EVA16 d. Exterior doors R /D e. Floors over unheated spaces R AV,9- f. Edge of slab on.grade(heated building) R vl,+ g. Basement/cellar walls (above grade) R &3 h. Basement/cellar walls(below grade) R 913 i. Heating/cooling-ducts-piping in unheated space R n�l� 6. Service(domestic)hot water heating device Conforms to minimum efficiency per code�_Yes No TEMPERATURE CONTROL MAXIMUM SETTING 140—WILL NOT BE EXEEDED is 'gnat Date Phone Number INSPECTOR'S REMARKS: Project Name: BP# Address: Building Permit Submission S -family dud14 Tzzo farruly duelling Checklist All items below must-be checked either yes,no or not applicable prior to submission of any building permit to the Town of QueensburyBuilding Department. If any of the below items are lacking,the-permit will not be accepted until such time as the application is deemed complete for submission. 1. Building Permit Application Completed ... ... 2. Energy Form or CheckMate Energy Code Compliance Forms Complete.. ❑no ❑n/a 3. Energy Code Inspector's Report from CheckMate Program.. ... ... ... ..... ❑no ❑n/a 4. Septic application completely filled out(if applicable)... ... ... ... ... ... ... ... s ❑no ❑n/a 5. Solid Fuel Burning or Gas Appliance Form... ...... 54'D ... ...... ... ... ... ... ... ... .❑yes [:]no 6. Electrical Inspection Form... ... ... ... ... ... ... ... ... ... ...... ... ... ... ... ... ... ..YqS ❑no ❑n/a 7. Two (2) complete sets of structural drawings... .. ... ... ❑ ❑ a) floor plan;b) foundation plan;c) cross sections:d) elevations; e)window and door schedule It 11 8. Two (2) site plans showing location of the structure to be built. ... ... ... ... 1 ❑no ❑n/a location of well or water lines,location of septic system or sewer line. 9. Setbacks from property lines to new structure ... ... ... ... ... ... ... ... ... ... .. [:]no ❑n/a 10. Setbacks to neighboring wells and septic systems,including onsite well... . Ono ❑n/a and septic systems (if applicable) 11. DrivewayPermit... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... s [:]no ❑n/a Date: (�3 Staff Initial: L:\SueHeminga;ay\BuMing.Pemut.FORMS\Generic Checklist.doc Building Permit Application Town of Queensbury Department of Community Development, 742 Bay Rd.,Queensbury,NY 12804 (518)761-825.6 A permit must be obtained before beginning construction. Permit No.: No inspection will be made until applicant has received a Fee Paid: valid building permit. Form must be.completed. Rec.Fee Paid: n Reviewed By: Applicant: "' GMT6tdAwt, tdac• Owner: BobvLWafd 40.au. Address: 28 ,4wlv., G,wti Address: 23 /)6 441 ue&vZ4 ,v I 1 /2e4s Phone#: r.193~(Qo7 Phone Tax Map Number: — —' oc-°J�J• l — - Subdivision Name: (if applicable) Lot Number: /House Number:01'x�Street Name 9" OR Property Location: 23 A.) lIC/u Li Zia 620,eoe� /v V/Z8o5 J4 New Building: Residential/Commercial Estimated Market Value of Construction: /60,OM ❑ Addition: Residential/Commercial If an Addition,what will use of addition be? a Alteration: Residential/Commercial ❑ No change to Exterior size: Residential/Commercial ❑ Other work: (describe ) Check Below Occupancy Info 1"floor sq.ft. 2° floor sq.ft. Other floor sq.ft, Total Sq.Ft. Single Family Dwelling 8 e 85-3 Two Family Dwelling Townhouse Multifamily Dwelling #of units Office Mercantile Manufacturing 1 car detached garage 2 car detached garage 3 car detached garage ' 1 car attached garage 2 car attached garage 3 car attached garage 8 w Storage Bldg.,Comm Storage Bldg.,Res, Other What is the proposed height of the structure: 23 feet 9 inches Will any second-hand or ungraded lumber be used? If so,for what? No. of Firenlaees to be installed: N O No..of Woodstoves to be installed: List below the person(s)responsible for supervision of work in regards to Building Codes: Name Address Phone No. Builder 4.)4,,j kdwz �. 20 / a W 3-'fa7 Plumber Mason Electrician Declaration: Please sign below after you have carefully read the statement: --- To the best of my knowledge the statements contained in this application, together with the plans and specifications submitted, are a true and complete statement of.-all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that Uwe shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes,an As Built Survey ensed urveyor;drawn to scale,showing actual location of all new construction. Signature: (circle one: owner,owner's agent,architec contractor) Application for Permit-Septic Disposal System - Town of Queensbury 742 Bay Road Queensbury, NY 12804 (518) 761-8256 1. OWNER INFORMATION: Office Use Location of installation: 23 4,,y lqb LA File Permit No. Tax Map No. r / 7 I Fee Paid Owner's Name: zgy,&i a,)AIZ ................................................ ......................................................... Address: Z 3 /;-,o lwo.4 12 ZA&Z to' Pia V f 2. INSTALLER'S NAME _T'r- . PHONE NO. 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gal/bdrm = 1980- 1991 x 130 gal/bdnn = 1991 -present x 110 gandrin = Garbage Grinder Installed yes no Spa or Hot Tub Installed yes_ / not 4. PARCEL INFORMATION: (circle applicable information&indicate measurements) Topography Soil Nature Ground Water Bedrock or Impervious Material Domestic Water Supply F117 sand at what depth at what depth municipal Rollin R loam —feet V/,f feet well slope clay NO #1r.1-4 if well; water supply %slope other 4-)A"x4- from any septic-system depth: absorption is_ft. other 1,44,ff Percolation Test: (To be completed by licensed professional engineer or architect) Rate:. 3 to/0 minute per inch SH SP-1 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic tank and leach field for each Garbage Grinder,Spa or Whirlpool Tub. Septic Tank: j(�C) gallon (min. size 1,000 gal.) Tile Field: each trench -40—ft. Total System Length: /,?6 ft. Seepage Pit(s): number of size of each: ft. by_ft. Size of Stone to be used: # 2 depth or thickness E' feet Bed System Size: x Alternative System: length and/or size 6. HOLDING TANK SYSTEM: (if required) Number,of tanks,:- Size of each: gallons TOTAL Capacity: gallons Note. Alann'Systern and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury.Sanitary Sewage Disposal Ordinance. Signature of responsible person Date Residential Plan Review: One&Two Family Dwellings Check Y/N/N/ (2)Full sets of plans Over 1,500 sq. ft.—stamped Design loads on plans: 90 wind Floor Loads 40 psf 70 ground snow load Sleeping areas and Attics 30 psf Calculations: Window Schedule with glass size Door Schedule/Main Entrance 36"Door Emergency escape for Bedrooms and Habitable Space Above/Below grade, 5.1 sq. ft. Grade, 5.0 sq. ft. 24 (h)x 20"(w)min. 44"Max.Height above floor Residential Check paperwork compliance and inspectors checklist: OK Vertical Rebar as required by code/Anchor Bolts %x 7 6' O.C. ` Dampproofing/Waterproofing materials on plans '41 Foundation Drainage on plans,if required 6"Drop in 10' Exterior Grade Framing cross section for each roof line,Vertical Fire Stopping every 10' where required 1`ce and Snow shield 24"inside exterior wall/Proper Vent,Attic Vent Platforms at exterior doors Stairway headroom 6 ft. 8 in. all stairs 36"Width Stair run and rise Winder run and rise Spiral not allowed from 21d story ,Smoke detectors battery backup and proper-location- Bathroom Fixtures proper-clearance Hall width, 36"min. Handrails more than one riser on open sides Railing and Guards>30"/Basement Stairs included./Closed Risers more than 4"in height Safety Glazing Notes for required areas - Garage Fire Separation _ Garage Floor Sloped Attic Access Roof over 30"—22"x 30" Crawl Spaces 18"x 24"Access Carbon Monoxide Detector lowest sleeping leveli Soil Test Results, if required Septic to well or water line separation All paperwork signed ,, Queensbury Building & Code Enforcement - Residential Final Inspection Office Office No.(518)761-8256 Arrive: am/pm art; ����am/pm Date Inspection request received: Inspector's Initials: _� NAME: W,4c PERMIT#: ✓ (J -� LOCATION: 'Z;j - 6uL74—(fz U C7 DATE: •5 TYPE OF STRUCTURE: Comments Y lei N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform-at all-exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum '/" Gypsum- Grade away.from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site `Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. athroom/Kitchen watertight Safeglazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched \ Garage fireproofing/'/4 hour fire door/door closer ✓ y 1(!� � �,L� Duct work Sealed properly C6 rl Gas Logs in Sealed or Glass Enclosure Attic access 30 in x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces I8"x 24"access, 1 s . ft.-150 s . ft.vents Building No./Address visible from road 'final Electrical ite Plan /Variance required / U`(f �PP� Final Survey Plot Plan tN As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forms\Res. Final Insp. form 2.docLast printed 2/12/04 Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 Date received: l NAME: AY-- LOCATION: kyTi <oiOi gr-? PERMIT#: 05 I I Final Survey Plpt Plan Approved Denied The attached final survey has been received by the Dept. of Community Development. Upon review the survey has been: Craig Brown, Zoning Administrator Notes: L:\SueHemingway\Building.Codes.Inspection.FORMS\Fina1 Survey Zoning Administrator.doe Queensbury Building & Code Enforcement - Residential Final Innsspecrion Office No.(518)761-8256 Arrive: am/pm artko#'O�!r : Date Inspection request received: Inspector's Initials: _C NAME: OJA-e-�^ PERMIT#: ✓ r LOCATION: 7� 6.'Ti�0,+_ [7 DATE: D S TYPE OF STRUCTURE: Comments Y N N/A Chimney Hi./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Co m lete Guard 30 in.or more @ stairs,decks patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at,.all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum ''/z" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp, 110 Interior privacy/trim/doors/main entrance 36 in. %athroorn/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/%hour fire door/door closer ✓�/ ( CTZ A,09Duct work Sealed ro erl CVd Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s .ft.-150 s .ft.vents Building No./Address visible from road final Electrical ite Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:1PamW\BuildinQ&Codes\Inspection Forms\Res.Final Insp, form 2.docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection / F 0-- Office No.(518)761-8256 Arrive: am/ Depart: 5 am/pm Date Inspection request received: Inspector's Initials:am/ Q NAME: _ PERMIT#: D-©v3—/ U I LOCATION: A DATE: TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" oe Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" Gypsum Grade away from foundation 6 in.with 10 ft. kzv Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing �a�A00- Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/1/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in x 22 in,x 30 in.(ht.)In accessible area Crawl Spaces 18"x 2 " acTess, 1 s . ft.-150 qq. ft.vents Buildin No./Addre i ble d tz inal Electrical Site Plan /Varianc re fired Final Surve Plot Plan As Built Se tic System/Sewer Dept.Inspection Sticker ' Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Insvection Forrns\Res. Final Inso. form 2.docLast printed 2/12/04 t Rough Plumbing / Insulation Inspection Report / Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm► D part: _am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: v1(iC� PERMIT#: LOCATION: l c3 f INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes W ter Supply Piping Copper Commercial Copper, CPVC,Pex One &Two Family f /Insulation/Residential Check/Commercial Check f itL�^ l L Proper Vent, Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly CONTENTS: -L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Rough Plumbing / Insulation Insp tion Repor Office No. (518) 761-8256 Date Inspection request received: ' Queensbury Building& Code Enforcement Arrive: am/p epart: am/pm f 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:� � N NAME: PERMIT #: LOCATION: — INSPECT QN: TYPE OF STRUCTURE: QS Y N N/A P C: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. z3 u Plumbing Vent/Vents in Place -Rough Plumbing/Nail Plates J 1 % inch min. Drain Size Vc,�l 1 H�J Washing Machine Drain 2 inch min. vat Head or Air Supply Test Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping C per Commercial 0o er,CPVC,Pex One and Two-Family Cool& I. Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.hispection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 1 Rough Plumbing / Insulation Inspection Repo ����_ Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/tym D part: am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: QPERMIT #: -/. LOCATION: - INSPECT ON: �l TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. Plu Vent/Vents in Place ou h Plumbin /Nail Plates 1-%--inch min. Drain Size (J odd Washing Machine Drain 2 inch min. Head or Air Supply Test I Drain and Vents 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper,CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape C MMENTS: ew L:\SueHemingway\Building.Codes.inspection.FORMS\Rough Plumbing Insulation Repoit.doc November 17,2003 Framing/Firestopping Inspection Report L� �i L� Office No. (518)761-8256 Date Inspection request received: ` d o Queensbury Building&Code Enforcement Arrive: am/pm part: ` m/pm 742 Bay Road, Queensbury,NY 1.2804 Inspector's Initials: NAME: �t �l PERMIT#: 3 �f LOCATION: INSPECT ON: TYPE OF STRUCTURE: 01 Y N N/A COMMENTS Framing . Jack Studs/Headers f I BracingBridging/ L �\��✓ ' `� '� 1AJ(—[5 Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center lee and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side 1/2 inch or 5/8 inch Type X Garage side 5/8 inch Type Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes,Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 z Foundation Inspection Report / "q A p Office No. (518)761-8256 Date InspectionrTET cei ed• Queensbury Building&Code Enforcement Arrive: , aDepart: � am/p 742 Bay Rd., Queensbury,NY 12804 Inspectors h3ni' l NAME: P #: LOCATION: - INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofmg/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval umbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Reportdoc January 28,2003 Foundation Ins ection Report Re ��PIT) p p Office No. (518) 761-8256 Date Inspectio request received: -Queensbury Building&Code Enforcement Arrive: 9 1 3f am/p Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: n, PERMIT#: 0 3 LOCATION: INSPECT ON: — TYPE OF STRUCTURE: L s Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 oly for wet areas under slab ill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:1SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Qffice-.No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: amJp ,D p 6epar am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: L NAME: . . PERMIT#: 6 LOCATION: . INSPECT ON:. TYPE OF STRUCT Comments Y N N/A otings Piers Monolithic Slab Reinforcement in Place —7 The-contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallp our Reinforcement in Place. Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC J Cast/Copper Foundation Insulation Interior/Exterior R Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Bui]ding.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pT3 Depart: m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: Q-QPERMIT#: LOCATION: INSPECT ON: I—J���3 TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab inforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. terials for this purpose on site. undation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump. Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building.Codes.Inspection.FORMSToundadon Inspection Report.doc January 28,2003 Queensbury Building & Code Enforcement - Residential Final InspectiorPP,)(C— Office No.(518)761-8256 Arrive: am/pm Depart: am/pm Date Inspection request received: Inspector's Initials: _ NAME: PERMIT#: LOCATION: DATE: _ TYPE OF STRUCTURE: _ _ Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more a�stairs,decks patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: 'Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched _ Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents irildin No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent L:\PamW\Building&Codes\Inspection Forrns\Res. Final Insp. form 2.docLast printed 2/12/04 3- C� Permit Number REScheck Compliance Certificate Checked By/Date 1995 MEC REScheckSoftware Version 3.5 Release I Data filename:C:\Program Files\Check\REScheck\Wall Carraige House.rck TITLE:Bob&Laurie Wall IF , CITY: Glens Falls APR 17 2003 STATE:New York HDD:7635 TOWN OF OUEENSSURY CONSTRUCTION TYPE: Single Family BUILDING AND GOD- DATE:04/16/03 DATE OF PLANS:4/16/03 PROJECT INFORMATION: Carraige House Wall residence 23 Antiqua Road Lake george,NY 12845 COMPANY INFORMATION: Howland Construction Inc. 28 Hunter Lane Queensbury,NY 12804 COMPLIANCE:Passes Maximum UA=351 Your Home UA=340 3.1%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 588 49.0 0.0 15 Ceiling 2:Cathedral Ceiling(no attic) 324 40.0 8.0 7 Ceiling 3:Flat Ceiling or Scissor Truss 211 49.0 0.0 5 Wall 1:Wood Frame, 16"o.c. 588 21.0 0.0 34 Wall 2:Wood Frame, 16"o.c. 150 21.0 0.0 9 Wall 3:Wood Frame, 16"o.c. 96 21.0 0.0 5 Wall 4:Wood Frame, 16"o.c. 1224 21'.0 0.0 53 Window:3759:Wood Frame,Double Pane with Low-E 121 0.530 64 Window:3347-3:Wood Frame,Double Pane with Low-E 32 0.530 17 Window:3747:Wood Frame,Double Pane with Low-E 85 0.530 45 Door:6082AI:Glass 41 0.450 18 Door:2/8x6/8: Solid 18 0.100 2 BaseMeot 1: Solid Cgncrete or Masonry 1224 13.0 0.0 66 Weil height:9.0' Depth below grade: 8.5' Insuldtion depth:9.0' Boiler 1:Other(Except Gas-Fired Steam),85 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 MEC requirements in RES checkVersion 3.5 Release lc (formerly MECchecl and to comply with,the mandatory requirements listed in the RES checkInspection Checklist.` 'Builder/Designer Date IX116lo 3 ' F.NEyy1, CD�Q �p ACr ' z� L Uj Cy ,i V• rn �� p66•752. �� . . - •REScheck Inspection Checklist 1995 MEC REScheckSoftware Version 3.5 Release I DATf.:04/16/03 TITL�:Bob&Laurie Wall Bldg. Dept. _ Use " Ceilings: [ ] 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-49.0 cavity insulation - Comments:Flat Ceilings up Living Area [ ] 2. Ceiling 2:Cathedral Ceiling(no attic);R-40.0 cavity+R4.0 continuous insulation Comments:Sloped ceilings around up living [ ] 3. Ceiling 3:Flat Ceiling or Scissor Truss,R 49.0 cavity insulation Comments:Garage area ceiling Above-Grade Walls: [ ] 1. Wall 1,:Wood Frame, 16".o.c.,R-21.0 cavity insulation Comments: 8'exterior precut 2nd level [ ] J 2. Wall 2:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments:4'kneewalls 2nd level [ ] 3. Wall 3:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments:sloped walls 2nd level ' [ ] 4. Wall 4:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments:garage level walls Basement Walls: L' Basement 1: Solid Concrete or Masonry,9.0'ht/8.5'bg/9.0'insul, R-13.0 cavity insulation Comments:Foundation walls Windows: [ ] 1. Window:3759:Wood Frame,Double_Pane with Low-E,U-factor:0.530 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments:Pella [ ] 2. Window:3347-3:Wood Frame,Double Pane with Low-E.U-factor:0.530 For windows without labeled U-factors,describe features:" #Panes Frame Type Thermal Break? [ ]Yes[" ]No Comments:Pella [ ] 3. Window'3747:Wood Frame,Double Pane with Low-E,U-factor:0.530 For'windows without labeled U-factors,describe features: #Panes, Frame Type Thermal Break?[ ]Yes [ ]'No Comments: Doors: [ ] 1. Door: 6082AI:Glass,U-factor:0.450 Comments:Pella French Door [ ] 2. Door:2/8x6/8: Solid,U-factor:0.100 Comments: Swing entry Heating and Cooling Equipment: [ ] 1. Boiler 1:-Other(Except Gas-Fired Steam), 85 AFUE or higher Make and Model Number Air,Leakage: [ ] Joints,penetrations,and,all other such openings in the building envelope that are sources of:air leakage must be sealed. . [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5 clearance from.combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance ffom insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating_and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation. [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All ducts must be sealed with mastic and fibrous backing tape..Pressure-sensitive tape may be used for fibrous ducts.. Duct tape is not permitted. ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to. partially restrict or shut off the heating and/or cooling input to each zone or floor.shall be provided. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-d_epletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 126 °F or chilled fluids below 55 T must be,insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1,' Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 -0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Ran e F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 . 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)