Loading...
2003-187 -Igor-- - .r TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 . Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20030187 Date Issued: Monday, November 10, 2003 This is to certify that-work requested-to be done as shown by Permit Number P20030187 has been completed. Tax Map Number: 523400-290-017-0001-040-000-0000 Location: 97 MASTERS COMMON NORTH Owner: MICHAELS GROUP LLC THE Applicant: MICHAELS GROUP LLC THE This structure may be occupied as a: By Order of Town Board Fireplace TOWN OF QUEENSBURY Garage - 2 Cars Attached Single Family Dwelling Director of.Building&Code Enforcement TOWN-OF QUEENSBURY .742 Bay Road;Queensbury,NY 12804-5902 (518)761-8201 Community Development:-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20030187 Application Number: A20030187- Tax Map No: 523400-290-017-0001-0407000-0000 Permission is hereby granted to: MTCHAFI.S GROUP LLC T14F, For property located at: 97 MASTERS COMMON NORTH in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and,approved and in compliance:with the NYS Uniform Building Codes and,the Queensbury Zoning Ordinance. Tyne of.Construction Value Owner Address: MICHAELS GROUP LLC THE 10 BLACKSMITH Dr Fireplace MALTA,NY 12020 Garage-2 Cars Attached Single'Family Dwelling $255,900.00 Total Value $255,900.00 - r Contractor or Builder's Name/Address I 's Electrical Inspection Agency MICHAELS GROUP 10 BI,ACKSMTTH Dr STE 1 MALTA.NY 12020 Plans&Specifications 2003-187 LOT 1 HSE#97 MASTER COMMON NORTH 2622 SQ FT SINGLE FAMILY DWELLING WITH 2-CAR ATTACHED GARAGE AS PER PLOT PLAN SPECIFICATIONS $365.44 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,May 13',2004 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) ' Dated at th of Qu sb esday,May 13,2003 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY (518)761-8205 Application for Fuel Burnsing Appliances & Chimneys applicable to solid fuel; &vented gas appliances Date 1 ,� , 20 Permit No. D j F 7 Application is hereby made to the Building;& Codes Office for the issuance of a Building and Use Permit pursuant to the'New York State Fire Prevention and Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances; regulations, and all conditions that are part of i these requirements and also will allow all inspectois to enter premises to perform required inspections. , NOTE to applicant; Rough-in and jFinal Inspections are required. Applicant Information Fuel Burning Appliance Information i (circle appropriate words) Name: _ l ,c� �� ��tt .� Stove: wood coal pellet gas Fireplace insert Address: Fireplace, factory-built: wood gawk p Y g i Fireplace,-masonry: wood gas d-- Furnace: wood (gas) oil Phone: If non-masonary applicance, please provide Owner: n'� _ Manufacturer Name: Address.: ° Model Number: Chimney Information Phone: (circle appropriate words) Masonry block _ick stone Flue the el size.• inches Exact Address: m6 f`',w, of construction or installation: Factory-Built Manufacturer name: ModellNumber: Note: Listed By: Number: Construction/Installation must ; con ortn to NYS Fire Prevention do Building �ndicate(circle) chimney material: Code. Consult available Town of Queensbury Handouts regarding required inspections. Dlpuble wall / Triple wall / Insulated / Direct venting C4ninev Liner - _ l IJ i Ca,al»[ex�'sr Depar�zrient Toxic of Qszeen�buzy, 3V"e sorb: Fire Marshal Code# $Collected $Rcfirnded Received from (reftiaded'to.) address; A 173 3389 (190) Public Safety —_- A 233 2655 (230)Minor,Sales DATE: t` 1 wLv i"vL�- l own. (i 02 CD 7 White(Applicant) / Green(Fire Marshal) ! Yellow JBIdg.Dept.) / Pink&Goldenrod(Cashier's Dept.) Building Permit Application Town of Qucensbury—Dept of Community Development, 742 Bay Road, Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No 07 No inspection will be made until applicant has received a Fee Paid i .valid building permit. All applicants' spaces on this Rec. Fcc Paid" $ I application must be completed and must appear on the Reviewed By. application form. A Applicant: Ir�lF-AA Owner: _Sb0E____ 200 Address: 1O 1[_ Icti\t� Address: 0 Phone# Phone# C_ o Property Location: Lot Number: I/ House Number �J-1 / z���r �mmcrn \moo Subdivision Name: �, rC� Tax Map Number: New Building: residence /conimcrcial Estimated Market Value of Construction: $ a55�C ❑ Addition: residence/ commercial If an Addition, what will use of new addition be? ❑ Alteration: residence/ commercial ❑ No change to exterior size: residence/cont'I ❑ Other work(describe ) Cheek Occupancylnformation V Floor 2"' Floor Other 17oor Total Below sq. fl. sq. fl. sit.11. Square Fed Single family dwelling ❑ Two family dwelling ❑ Townhouse ❑ Multifamily dwelling #of units ' ❑ Office ❑ Mercantile ❑ Manufacturing ❑ 1 car detached garage ❑ 2 car detached garage ❑ 3 car detached garage ❑ I car attached garage_ _ 2 car attached garage �•- ❑ 3 car attached garage _ ❑ Storage building; commercial ❑ Storage building- residential ❑ Other Will any second-hand or ungraded lumber be used? If so, for what? ,N Type of I-leating System: electric/ oil / gas wood /forced hot air/ baseboard/other: Number of Firet)laces to be installed CAL . Number of Woodstoves•to be installed JA& List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Cam.__ �__�•. �_� �. Plumber Mason M.s �421— Electric ian %-C � \C � {� 1—(MYCL Declaration: please sign below aner you have carefully read the stalcment: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code, the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further, it is understood that Uwe shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes,an As Bailt Sarver by a licensed surveyor;drawn to scale,showing actual location of all new construction. Signature: owner,owner's agent, architect,contractor 9 Residential Plan Review: One &Two Family Dwellings Check Y/N/N/A (2)Full sets of plans Over 1,500 sq. ft.—stamped ' Design loads on plans: 90 wind Floor Loads 40 psf 70 ground snow load Sleeping areas and Attics 30 psf Calculations: — Window Schedule with glass size Door Schedule/Main Entrance 36"Door Emergency escape for Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade, 5.0 sq. ft. 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check paperwork compliance and inspectors checklist: OK r� Vertical Rebar as r quired b co /Anchor Bolts %2 x 7 6' O.C. 1� Dampproofmg/Waterproofing materials on plans Foundation Drainage on plans,if required 6"Drop in 10' Exterior Grade Framing cross section for each roof line,Vertical Fire Stopping every 10'where required Ice and Snow shield 24"inside exterior wall/Proper Vent,Attic Vent Platforms at exterior doors Stairway headroom 6 ft. 8 in. all stairs 36"Width Stair run and rise Winder run and rise Spiral not allowed from 2" story Smoke detectors battery backup and proper location Bathroom Fixtures proper clearance Hall width,36"min. Handrails more,than one riser on open sides Railing and Guards>30"/Basement Stairs included/Closed Risers more than 4"in height Safety Glazing Notes for required areas Garage Fire Separation Garage Floor Sloped Attic Access �- Roof over 30"—22"x 30�"�t Crawl Spaces 18"x 24"Access Carbon Monoxide Detector lowest sleeping level Soil Test Results,if required Septic to well or water line separation All paperwork signed TOWN OF QUEENSBURY BUILDING & CODE ENFORCEMENT 742 '.BAY ROAD QUEENSBURY NY 12804 (518) 761-8256 ARRIVE: DEPART: INSP: FINAL INSPECTION REPORT (hotel, motel, apt. complex) DATE INSRZCTION R UEST R IVED• NAME LOCATION DATE i PERMIT N 03-127 TYPE OF STRUCTURE FOOTINGS _BACKFILL_ FRAMING_ PLUMBING_ INSULATION N/A_ YES NO CHIMNEY/"B" VENT 11EIGHT PLUMBING VENT FIXTURES ROOFING EXTERIOR FINISH HEATING/HOT WATER RELIEF VALVES `FLOORS FOUNDATION INSULATION INTERIOR STAIRS/RAILINGS STOCKROOM ENCLOSURE FIRE/DEMISE WALLS PENETRATION FIRE DAMPERS CEILING FIRE STOPPING FIRE DOORS CLOSERS EXIT DOOR HARDWARE EXIT STAIRS/RAILS PLATFORM ELEVATOR HANDICAPPED ACCESS HANDICAPPED BATHS HANDICAPPED PARKING FINAL ELECTRICAL a _ SITE AN VARIANCE RE . FINAL SURVEY PLOT PLAN, IF RE OK TO ISSUE C/O OR C C Residential Final Inspection Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p epart: 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: �S -P ` PERMIT#: r LOCATION: DATE: ?16 TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in.or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in. to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight /•/ /�u /Q�/s / Safety glazing Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Bathroom Fans, if no window - $ A--'--C•-S Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emer ney egress below grade Basement stairs closed rise>4 inches %hour fire door/door closer Garage fireproofing Duct work Sealed properly Attic access 30 in.x 2 in.x 30 in. ht. In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s .ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C/O(Cert. Of Occupancy) Okay to issue Permanent C/0(Cert. Of Occu ancy) �� (c� Residential Final Inspection Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ m Dep �� am/pm 742 Bay Rd., Queensbuiy,NY r12804 Inspector's Initials: p �/ NAME: �`�(/l\ �6", PERMIT LOCATION: Z ZT3 1 , n M . U DATE: TYPE OF STRUCTURE: Comments " Y 1�T N/A ` Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete le Guard 30 in.or more @ stairs,decks,patios / '� � ���5 Guard at stairwell at 34 in. or more ` "114 , Guard at deck,porches 36 in. or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Grade away from foundation 6 in.with 10 ft. Handrail Tdrnunation at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backu : Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor tniss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches. %hour fire door/door closer Garage fireproofing Duct work Sealed properly Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s , ft.-150 s .ft.vents BuildingNo./Addrq&visible from ad Final Electrical , 'pus,r / i1 Site Plan /Varianc re ui ed �/ it `7U/�V�? Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C(Cert. Of Compliance) Okay to issue Temporary C/O(Cert. Of Occupancy) Okay to issue Permanent C/O(Cert. Of Occu anc L:\SueHen-d6gway\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doe edited January 28,2003 Town of Queensbury Fire Marshal 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas Fireplace/Stove InsRection Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. permit# � / Schedule Inspection/ /4✓ Time �'yo am pipe anytime Inspector Name M6kd 6_rft� Address 99 lt&.i hough In Final Appliance Manufacturer Model# Direct Vent Factory Built Chimney Flue Size Rouble Wall Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (ail sides) Firestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Shut-Of Valve Combustion Air Hearth Extension(if any) Mantel Height above f/p opening Witness Operation Tank Placement(if LP) White—Building Dept. Yellow C er Pink—Fire Miumhal Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pn Depart:_ s am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: v/// 5 • PERMIT#: V� LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast iron,Copper. Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping opper Commercial Copper,CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: -L:\SueHemingway\Building.Codes.Inspection.FORMS\Rougb Plumbing Insulation Report.doc January 28,2003 Rough Plumbing /Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/prn Depart: I Zf n-/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: } PERMIT#: C> �U 7 LOCATION: Z-12S INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper, CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check V� Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly �d CO tj A COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive:—am/pm. Depa _ — ,5 am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: 77 NAME: 6k,J v PERMIT#: ® " '`�GW 1 ' 67 LOCATION: -7 V-kA 5 on, . INSPECT ON: 3 d TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place i 1 ! r1 Rough Plumbing/Nail Plates S P 2 LUU Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper, CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent ` Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: L:\,SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ part: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials:. NAME: S PERMIT#: 05 — `f-7 LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y �N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. 2 FAL Plumbing Vent/Vents in Placei�k ��� Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper, CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: ueHmingway\Building.Codes.Inspection.FORMSaough Plumbing Insulation Report.doe January 29,2003 r'� Rough Plumbing /Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/prapm 742 Bay Road, Queensbuly,NY 12804 Inspector's Initials: ` NAME: PERMIT#: ozz, �l LOCATION: INSPECT ON: 1 TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes ter Supply Piping Copper Commercial Co per, CPVC,Pex One &Two Family Insulation/Residential Check/Commercial Check 0 r ( U�►! (��� i Proper Vent,Attic Vent C� I U 2 Cd R Apcp� Duct/Hot Water Piping Insulation J If required unheated spaces Combustion Air Supply for Furnace ICvK( C7;o GL . Duct Work Sealed Properly ) _ COMMENTS: L:\SueHemingwaylBuilding.Codes.Inspection.FORMS\Rough Plumbing Insulation Report-doe January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: C ro A .3 Queensbury Building&Code Enforcement Arrive: am/p De art: a pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: �J NAME: / /1� I PERMIT#: 3—�� LOCATION: �. r INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron, Copper Drain/Vent/Comm. W Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial r, CPVC,Pex One &Two Family G ���� - �� sulati n Residential Check/Commercial Check �(��r Proper Vent,Attic Vent Duct/Hot Water Piping Insulation v Er 6AIP5 @ r b8 If required unheated spaces Combustion Air Supply for Furnace c6Rjuf-P u�,P— Q v*7--- Duct Work Sealed Properly colNTs: c 1:\Sue14emingway\Bui]ding.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: am/p D part: . n/pm 742-Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: CI& PERMIT#: LOCATION: INSPECT ON: O�S TYPE OF STRUCTURE: Framing Y YN N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %z (w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingWay\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 / 144-/ Framing /Firestopping Inspection Repo Office No. (518) 761-8256 Date Inspection request recei ®J Queensbury Building&Code Enforcement Arrive: am/p art: ai pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: -'- � ct .may s 04-/, NAME: G'`�if` PERMIT#: 3--/.? LOCATION: 9 INSPECT ON: TYPE OF STRUC Y N N/A COMMENTS Framuig , -ha -` I Jack Studs/Headers 0 o� Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. P�du S7 l./� ,`�`� U� S Headroom 6 ft. 8 in. Stairwells 36 in. or more w�C��' Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3,4 hour yp 3Firestopp7rig - - e a ion sealed _ 16 inch insulation in cavity min. Garage Fire Separation House side 'I/2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable'Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Framing /Firestopping Inspection Report cv, Office No. (518) 761-8256 Date Inspection request received: 9/3 G3 Queensbury Building&Code Enforcement Arrive: am/JJ�Depart:--- pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: t NAME: ' - PERMIT#: 7 LOCATION: o INSPECT ON: TYPE OF STRUCTURE: Y N N/A COMMENTS Sack Studs/Headers pa'&U- v Db AV ri Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. C4—ez-o-TG- �kA-0 GG� PN N t`t NL+ Headroom 6 ft. 8 in. t/ Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls �,`UV` C N� ke, 1 6'�� Metal Strapping for Notches Top Plate � �p 1 %z(w) 16 gauge(8) 16D nails each side ` , Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fir ,4 hour /i✓f'A 7 TD 4, `Penetration sealed IAA-�.L 16 inch insulation in cavity min. Garage Fire Separation House side ''/a inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade GPI4017 L:\SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Eqb vTlem +' o3 l o 31�0 Rough Plumbing / Insulation Inspection Report Q Office No. (518) 761-8256 Date Inspection request received: < 1(j Queensbury Building&Code Enforcement Arrive: am/ Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: - NAME: }Gd 1� PERMIT#: LOCATION: INSPECT ON: 2 TYPE OF STRUCTURE: J Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place o gh Plumbi g/ ail-Plates ea or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper,CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: 1:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doe January 2g,2003 Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/prI>, „Depart: am/pm 742 Bay Road, Queensbuly,NY 12804 Inspector's Initials: c,���� NAME: GYI PERMIT#: LOCATION: Gv`� _ INSPECT ON: O TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI 10 ft. above highest PSI for 15 minutes ter Supply Piping Copper Commercial Copper,CPVC,Pex One &Two Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: L:\,SueHemingwaylBuilding.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: G 3 Queensbury Building&Code Enforcement Arrive: am/pr� e art: m 742 Bay Road, Queensbuiy,NY 12804 Inspector's Initials: J - a NAME: l�`�'vL, (--' "'�Y' PERMIT#: a603 - LOCATION: Q 72 INSPECT ON: OP 16-3 TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent/Vents in Place ough lumbin Nail Plates Head or Air Supply Test Drain and Vents //JJ 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial � � yon-U Copper,CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check S�FLIq 'PeZAr AJ Proper Vent, Attic Vent l Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doe January 28,2003 Framing / Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received- Queensbury Building&Code Enforcement Arrive: am/p D art: pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: ( onPERMIT#: d 3 l �� LOCATION: �O INSPECT ON: 7 —aL1-0 3 TYPE OF STRUCTURE: Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %2 (w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center ce and snow shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemineway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-82.56 Date Inspection request re ved: Queensbury Building&Code Enforcement Arrive: -am/k9_ Depart: ` am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: /Y(6ff+1W,S 6 PERMIT#: LOCATION: xv INSPECT ON: aIlle O TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place + Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width _ 6 ' ches above footing yL mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:4SueH=ingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (51-8)761-8256 Date Inspection request received: f Queensbury Building&Code Enforcement Arrive: ani/Dm Depart: m/pIn / 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: - LOCATION: `" °r ►MI(MINSPECT ON: , L. ) TYPE OF STRUCTURE: i(j Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place w Foun ation Dampproofing ca IZ 1TA , . vV aterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Y07Fin!Rwilddth .� one: 6 inches above footing 6 mil poly for wet areas under slab / l Bacicfill Approval t '7Tv/ )C— Plumbing Under Slab �l p PVC/Cast/Copper �' Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\Building,Codes,InspectionTORMSToundation Inspection Report.doc January 28,2003 2 5'� Foundation Inspection Report Office No. (51'8)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Depart: m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: Gry L PERMIT#: 04 3 LOCATION: !✓w�+Sir Cw�•�wv1 r�r` ii INSPECT ON: TYPE OF STRUCTURE: i Comments Y N/A— . 4 Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for Y providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. ` L:\SueHemingway\Bui]ding.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 - 02003 -/ Pe er RFD APR1 � REScheck Compliance Certificate 2003 hecked B to -OI�' ,�_ y New York State Energy Conservation,C�rwttr•� eiriom „o ff REScheekSoftware Version 3.5 Release lb COL)E Data filename: C:\Program Files\Check\REScheck\Complete Works\HILAND\97 Masters Common North.cck TITLE:H1783 -Avalon COUNTY:Warren STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE: 04/11/03 DATE OF PLANS:March 25,2003 PROJECT INFORMATION: Udall Residence Queensbury,N.Y. 12804 COMPANY INFORMATION: The Michaels Group 10 Blacksmith Dr. Malta,N.Y. 12020 NOTES: Avalon @ Hiland all options are included Pella proline windows COMPLIANCE:Passes Maximum UA=519 Your Home UA=463 10.8%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 2:Raised or Energy Truss 1817 30.0 0.0 58 1st floor walls:Wood Frame, 16"o.c. 2122 19.0 0.0 107 2x Mbr(BF):Wood Frame,Double Pane with Low-E 29 0.340 10 lx Mbr(BG):Wood Frame,Double Pane with Low-E 29 0.340 10 lx opt.Mbr(BP):Wood Frame,Double Pane with Low-E 10 0.340 3 lx Mbath(D):Wood Frame,Double Pane with Low-E 15 0.340 5 Mud rm,#20: Solid 19 0.240 5 lx Living(BL):Wood Frame,Double Pane with Low-E 27 0.340 9 Entry#lA:,Solid 22 0.350 8 3x Dining(Y):Wood Frame,Double Pane with Low-E 41 0.340 14 2x Brkfst(BJ):Wood Frame,Double Pane with Low-E 22 0.340 7 Brkfst#7: Glass 47 0.400 -19 lx Kitchen(BH):Wood Frame,Double Pane with Low-E 16 0.340 . 5 lx Family(BF):Wood Frame:Double Pane with Low-E 14 0.340 5 lx Family(BQ):Wood Frame:Double Pane with Low-E 56 0.340 19: 2nd floor walls:Wood Frame, 16"o.c. 1263 19.0 0.0 69 Ix Bath(N):Wood Frame,Double Pane with Low-E 6 0.340 2 lx Bed#3 (BK):Wood Frame,Double Pane with Low-E 29 0.340 10 lx Bed#3 (BS):Wood Frame,Double Pane with Low-E 5 0.340 2 1x Bed#2(DK):Wood Frame,Double Pane with Low-E 29 0.340 10 lx Foyer (BU):Wood Frame,Double Pane with Low-E 7 0.340 2 2x Loft(BS):Wood Frame,Double Pane with Low-E 10 0.340 3 lx Family(BR):Wood Frame,Double Pane with Low-E 20 0.340 7 Basement Wall 1: Solid Concrete or.Masonry 1081 0.0 11.0 70 Wall height:7.6' Depth below grade: 6.6' Insulation depth: 6.0' Window 18:Wood Frame,Double Pane with Low-E 5 0.560 3 Opt.bsmnt bay wall: Solid Concrete or Masonry 13 0.0 11.0 1 Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 6.0' Plant-shelf over foyer: All-Wood Joist/Truss, Over Outside Air 9 19.0 0.0 0 Furnace 1:Forced Hot Air, 80 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation.Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or " specifications are in complianc ith this C e. Builder/Designer Date Ir"CEScheck Inspection Checklist New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lb DATE:04/11/03 TITLE:HI783-Avalon Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 2:Raised or Energy Truss,R-30.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. Above-Grade Walls: [ ] 1. lst floor walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 2. 2nd floor walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 1:Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insul, R-11.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. [ ] 2. Opt.bsmnt bay wall: Solid Concrete or Masonry,7.6'ht16.6'bg/6.0'insul, R-11.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. Windows: [ ] 1. 2x Mbr(BF):Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 2. lx Mbr(BG):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 3. lx opt.Mbr(BP):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 4. lx Mbath(D): Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 5. 1x Living(BL):Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 6. 3x Dining(Y):Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: j #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 7. 2x Brkfst(BJ):Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: j #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] j 8. lx Kitchen(BH):Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] j 9. lx Fan-lily(BF):Wood Frame:Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors;describe features: j #Panes Frame Type Thermal Break?[ ]Yes [ ]No j Comments: [ ] j 10. lx Family(BQ):Wood Frame:Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No j Comments:_ [ ] 11. lx Bath(N):Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: j #Panes Frame Type Thermal Break? [ ]Yes[ ]No j Comments: [ ] j 12. lx Bed#3 (BK):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No . Comments: [ ] 13. lx Bed#3(BS):Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No j Comments: [ ] j 14. lx Bed#2(DK):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 15. lx Foyer (BU):Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: j #Panes Frame Type Thermal Break? [ ]Yes [ ]No j Comments: 16. 2x Loft(BS):Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] j 17. lx Family(BR):Wood Frame,Double Pane with Low-E,U-factor: 0.340 For windows without labeled U-factors,describe features: j #Panes Frame Type Thermal Break? [ ]Yes [ ]No j Comments: [ ] j 18. Window 18:Wood Frame,Double Pane with Low-E,U-factor:0.560 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No j Comments: Doors: ] j 1. Mud rm.#20: Solid,U-factor: 0.240 j Comments: [ ] 2. Entry#IA:Solid,U-factor:0.350 f Comments: [ ] j 3. Brkfst#7:Glass,U-factor: 0.400 Comments: j Floors: [ ] 1. Plant shelf over foyer:All-Wood Joist/Truss,Over Outside Air, R-19.0 cavity insulation Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1:Forced Hot Air, 80 AFUE or higher Make and Model Number Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls, and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values,glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State ,the Residential Code of New York State or the New York City Building Code ,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate cir r culating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. l Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. i a Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circa atmg Runouts Circulating Mains and Runouts Temperature(F) Up to p to to 2.011 Over 170-180 7 -- T.T - 1.5 Tu 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(F) unouts and Less to . to 4 Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) 1 MAP REFERENCE: MASTER'S COMMON NORTH DATED: AUGUST 26, 1987 BY: VAN DUSEN & STEVES FILED: MARCH 10, 1988 DRAWER 17 FOLDER 1 E­4yy S83031'311E W 150.06' o n O _ 3 ASPHALT DRYS c� o Tod� y j V s i — 40.65' 1 2 STORY WOOD FRAME HOUSE WW [� ■ � 33.76' L N - N CD o N O N Z LOT 1Go o 131,137.96 sq ft ao04 �! 0 0.71 acres ° 1 t 132.82' N82°13'35°W I HAVILAND ROAD C. •. • • o D _ Date, NOVEMBER 5, 2003 S 'UNALTHCNRED ALTERATION OR ADDITION TO A SURVEY Scale 1'=30' a u L MAP BEARING A ED LAND SURVEYORS SEAL IS A Map of a Survey made for �... VIOLATION OF SECTION i 7409.S1N-DINSION 1.OF THE NEW YORK STATE EDUCATION LAN.' 'ONLY COrItl rRDM THE ORIGINAL Or TNIS SUR12Y jj P P i �.a V V-t/ s MARKED WITH AN ORIGINAL Or THE LAND SURV[rDRS - S- 1 SEAL SMALL BE CONSIDERED lb BE VALID TRUE COPIES' : ` CE SURVEY WAS INDICATED HEREON DANCE%VTH RI�C HARD P . - & LO I S H 1 UDALL I THIS SUtVEY WAS PREPARED tN ACCORDANCE Mt111 THE L a IZ d S Ll Y'V e Y O r ►.� EXISTING CODE OF PRACTICE A l LAND SURVEYORS ADOPTED BY 11$NEW VOIMC STATE ASSOCIATION OF PROFESSIONAL 1 LAND SURVEYORS.SAID CERTNICATIONS SMALL RUN ONLY. TO THE PERSON FOR WHOM THE SURVEY IS PREPARED.AND 1/'� 1 OF: 21 ON MS BEHALFLTD THE STEP COMPANY.GOVERNMENTAL Q ry Warren COilnty, 169 Haviland Road Queensbury, `New York 12804AGENC'Y AND a HEREON.. ""° Town of ueensbu , -New York UDALL 5 9 - DWG. CN- ( 18) 7 2 8474 New York IAic. No. 50135 ' NO. DATE DESCRIPTION No M 1 MAP REFERENCE: MASTER'S COMMON NORTH DATED: AUGUST 26, 1987 BY: VAN DUSEN & STEVES FILED: MARCH 10, 1988 DRAWER 17 FOLDER 1 S83031 '316E ..� 150.06' j O f o ASPHALT DWYE N O d, O y — 40.65' p� H n 2 STORY WOOD FRAME HOUSE (w� W 33.7G f � N N O N Z j LOT 1 M o 00 _ b 31,137.96 sq ft Co a 2 0.71 acres to ° y 132.82' N82013'35"W �-7 HAVILAND ROAD Date, NOVEMBER 5, 2003 -� D u ,S' i 'UNAU,HORRED ALTERATION CR ADDITION TO A SURVEY Scale 1'=30' MAP BEARING A LICENSED LAW SURVEYORS SM IS A Map of a Survey made for •�`�/ VIOLATION OF SECTION'7200,SUB-DIVISION 2.OF THE NEW YORK STATE EDUCATION LAW MW'ID WITH L`A Nb TSHUDR VSCUrRR0SteVeS SEAL SHALL BNE OCGNMDERDEO EY BE VAUD TRUE COPIES.' CERTIFICATIONS PREPARED IN ACO1 DANCE THAT R I C HAR D P . & L O I S H. U D ALL THIS SURVEY WAS PREPARED IN ACCORDANCE NTH THE Land Surveyors BY THE EW PRACTICE FOR LAND SURVEYORS ADOPTED BY THE NEW YCRK STATE ASSOCIATION OF PROFESSIONAL LAID SURVEYORS SAID CERTIFICATIONS SHALL RUN ONLY TO THE PERSON FOR RHOM THE SURVEY IS PREPARED,AND SHEET 1\/�F 1 ON MS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL 169 Haviland Road Queensbury, New York 12804 AGENCY AND LENDING RNS7ITUITION LISTED HEREON.AND Town of Queensbury, Warren County, New York To TTIG A2WHIMS Of TI!L"NG INSTITUTION.' UDALL (518) 792-8474 New York Lic. No. 50135 1 1 NO. DATE DESCRIPTION DWG. NO. MCN-1 LI U- 1 -