Loading...
RC-0836-2021 Office Use Only ADDITION/ALTERATION PERMIT Permit#: 20Z APPLICATION .Town:ofCjucensbury Permit Fee:$ 2� 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.aueensbury.net Invoice#: Project Location:_62 Country Club Rd Tax Map ID#:_296.14-1-51 Subdivision Name: CONTACT INFORMATION: • Applicant: Name(s): Hilltop Construction Company Mailing Address, C/S/Z: 51 Crowley Rd. Hudson Falls, NY 12839 Cell Phone:_(518)_258-9327_Land Line: _(518)_798-0338 Email:_tomjr@hilltopconstructionco.com V • Primary Owner(s): NOV 22 �011 _Name(s):_Frank and Cindy Steciuk T BU LDFQUEENSq Mailing Address, C/S/Z:_62,Country Club Rd. Queensbury,NY 12804 G& CODESRY Cell Phone: 518 52774323 Land Line: ._( ) Email:_cindy.steciuk@gmail.com ❑ Check if all work will be performed by homeowner only • Contractor(s): Contact Name(s):_Tom Albrect Jr., Hilltop Construction Contractor Trade: General Mailing Address, C/S/Z:_51 Crowley Rd. Hudson Falls,NY 12839 Cell Phone:_(518)_258-9327 Land Line: _(_518)_798-0338_ Email:_tomjr@hilltopconstructionco.com "List all additional contractors on the back of this form • Architect(s)/Eneineer(s): Business Name: Oldenquist Design Architecture and Planning Contact Name(s): Nina Oldenquist, AIA Mailing Address, C/S/Z: 15 Dixon Ct.Queensbury,NY 12804_ Cell Phone:_(518)726-6557 Land Line: _( ),_n/a Email: Nina@OldenquistDesign.com Contact Person for Building & Code Compliance: Nina Oldenquist,AIA Cell Phone:_(_518)_726-6557 Land Line: _( ) Email: Nina@ OldenquistDesign.com Addition/Alteration Application Revised February 2019 PROJECT INFORMATION: TYPE: ❑ Commercial X Residential WORK CLASS: X Single-Family ❑Two-Family ❑Multi-Family(#of units ) ❑Townhouse El Business Office El Retail ❑ Industrial/Warehouse ❑ Garage (#of cars ) ❑ Other(describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 78 211 floor: 2nd floor: 290 3rd floor: 3rd floor: Basement(habitable space): Basement (habitable space): Total square feet: Total square feet:_368 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $_50,000 2. If Commercial project,what is the proposed use: 3. Source of heat: ©Gas❑Oil❑Propane❑Solar ❑Other Fireplaces need a separate Fuel Burning Appliances&Chimney Application 4. Are there any structures not shown on the plot plan? DYES ©NO Explain: 5. Are there any easements on the property? DYES Shared driveway access ®NO 6. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? _2.02 acres b. Is this a corner lot? DYES ONO c. Will the grade be changed as a result of the construction? DYES ONO d. What is the water source? ®PUBLIC El PRIVATE WELL e. Is the parcel on SEWER or a PRIVATE SEPTIC system? _Septic Addition/Alteration Application Revised February 2019 DECLmARATION: 1_ I acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. 1 acknowledge that prior to occupying the facilities proposed i, or my agents, will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities priorto issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Tom Albrecht Jr., Hilltop Construction Co. SIGNATURE: DATE: 11/22/21 AMWOMAN Waft Romw ftmny lug Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (1 of 2) Two (2) full sets of plans -G Over 1,500 sq. ft. requires engineering stamp Design loads on plans: 115 Wind Floor Loads 40 psf e (North of Rte. 149 60) 50 Ground Snow Load Sleeping Areas &Attics 30 psf Calculations Decks 40 psf Wind design for lake front properties G Window schedule with glass size & main doors/Air leakage< .5 cfm for doors, < .3 cfm for windows/Tempered glass in bathrooms Door schedule/Main entrance 36" door Z- Emergency Escape or Bedrooms & Habitable Space Above-grade: 5.7 sq. ft. Grade: 5.0 sq. ft. 24" (h) x 20" (w) minimum 44" maximum height above door Window control devices 24" or less 2nd story or 72" above grade Egress window from basement 5.0 sq. ft. q­0 Floor system sizing per table 502.3.1 Residential check ERI or Prescriptive method Driveway length: 300' or more-12' width required/500' or more,turnaround required Foundation drainage on plans, if required 6" drop in 10' exterior grade Framing cross section for each roof line, vertical fire stopping every 10'where required/joist spans pg. 127 „j Ice &snow shield-24"from exterior wall �a Platforms at exterior doors b, Stairway headroom 6'8"; all stairs 36" vAdth fj d Stair run and rise Iti Winder run and rise Spiral stairs meet requirements Smoke detectors—battery backup & proper location, interconnected Bathroom fixtures—proper clearance vS Hall width-36" width s Handrails more than four risers on open sides -e,S Railing&guards >30"/basement stairs included/closed risers more than 4" in height A Safety glazing notes for required areas Garage fire separation:%" gable end/5/8" under living space &%" on walls/20 min. door and closer l - —, Garage floor sloped +-1 y v Attic access: gasket seal & R-value eq I to roof insulation ejt�l cS l 1L Roof over 30"-22" x 30"/Crawl spaces 18" x 24" access Continued on back 4 4 Residential Plan Review Revised October 2021 Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (2 of 2) Carbon Monoxide detector outside lowest sleeping area, on every level & interconnected within 15' of sleeping area V � Soil test results, if required Septic to well or water line separation All paperwork signed Note on plans energy saving light bulbs 90% Blower door test agency paperwork .L Floodplain Permit required —check map: 2 feet above flood elevation Hurricane clips required Floors less than 2 x 10 covered by%" gypsum or 5/8" wood panel ,kj Manuals S &J required for heating system. Cold air return hard piped Separate room for draft HVAC or hot water heater with fresh air HRV shown and calculations jj Baffles at eaves for insulations and knee walls Makeup air for range hood >400 cfm Continuous header for garage doors to end wall 'u Chimney rain cap shown for fireplaces Deck hold down shown not less than 4 lags and bolts per table 507.2 Residential Plan Review Revised October 2021 <IInsulation Certificat D FEB 2 2 2022 NOT I�EI4�O TOWN OF QUEEfVSBURY ®® �� E. PLEASE POST NEAR -LE ' i r G' ° NEL. This form must be filled out and posted to comply with building code requirements. Meets IRC requirements: 2006 IRC-N1101.2, N1101.4, N1101.8 2009 IRC-N1101.2, N1101.4, N1101.8 2012 IRC-N1101.3, N1101.7, N1101.12 The following spray polyurethane foam product(s)has/have been installed, ❑Classic X Classic Plus ❑ ProSeal ❑ ProSeal Eco ❑ MD-0-200 ❑ Other Please consult International Building Code(IBC), Chapter 26-Plastic and International Residential Code (IRC)2006 IRC R314,2009 IRC R316,2012 IRC R316-Foam Plastics for specific requirements.The aforementioned Icynene spray polyurethane foam insulation system(s)has/have been installed in accordance with manufacturer's processing guidelines to provide a thermal resistance of: Area Insulated Aged R-Value Thickness* Attic Area R- at inches Sloped Ceilings R- at inches **Walls(location): Bonus Room North elevation R- R-21 at 5,25' inches *Walls(location): Bath_No.&adjacent to garage R- R-21 at 5.25" inches Floors(over an unheated crawl space) R-0 at inches Crawl Space Perimeter R- at inches Basement Walls R-�� at inches Other(location): Floor(s)_Bath &Bonus Room I R- 30 at 7.5 inches 'Nominal thicknesses are representative of field,spray-appned foam material. **Class If Vapor Retarder applied over Open cell foam Jobsite Address 1 62 Country Club Road Queensbury Date of Insulation Installation 0212022 Building Contractor Hilltop Construction Co. Insulation Contractor ASF Insulation Inc. Insulation Contractor Phone 5 8.309.5141 Installed By Icynene Inc. 6747 Campobello Road Mississauga,Ontario L5N 2L7 Canada \ Ph:1.800.758.7325 • ICYNENE.COM KYNENE SL-601 - Updated April 2015 The Evolution of Insulation ES ;� iMES Evaluation Report ESR-9626 Reissued February 2021 Revised September 2021 This report Is subject to renewal February 2022. www.icc-es.ora 1 (800)423.6N7 1 (SO)699-0543 A Subsidiary of ft International Code Councl!® DIVISION:07 00 00—THERMAL AND MOISTURE to seal areas such as plumbing and conduit penetrations PROTECTION against air Infiltration. The insulations are for use In wall Section:07 21 00—Thermal Insulation cavities and floor assemblies;and in attic and crawl space Installations as described in Section 4.4. REPORT HOLDER: The Classic, Classic Ultra and Classic Ultra Select HUNTSMAN BUILDING SOLUTIONS LLC Insulations are for use in Type V construction under the IBC and dwellings under the IRC; fire-resistance-rated construction when Installed In accordance with Section 4.5; EVALUATION SUBJECT: and in Types t through IV construction when installed in accordance with Section 4.6. CLASSIC,CLASSIC ULTRA,CLASSIC ULTRA SELECT The Classic Plus Insulation is for use in nonfire- AND CLASSIC PLUS resistance-rated construction under the IBC and IRC and 1.0 EVALUATION SCOPE In Types I through N construction when installed In accordance with Section 4.6. 1.1 Compliance with the following codes: The attributes of the Insulations have been verified as w 2021,2018,2015,2012 and 2009 Intemallonal Building conforming to the provisions of ICC 700-2008 Section Code®(IBC) 703.2.1.1.1(c)as an air impermeable Insulation.Note that decisions on compliance for those areas rest with the user ■ 2021, 2018, 2015, 2012 and 2009 lntemadonal of this report. The user Is advised of the project-specfftc Residential Code®(IRC) provisions that may be contingent upon meeting specific a 2021, 2018, 2015,2012 and 2009 International Energy conditions, and the verification of those conditions is Conservation Code®(IECC) outside the scope of this report These codes or standards often provide supplemental Information as guidance. ■ 2013 Abu Dhabi Intemedonal Building Code(ADIBC)t 3.0 DESCRIPTION Me ADIBC Is based on the 2009 IBC.2009 BC code sections referenced 3.1 General: In lids report are the same sections In the ADiBC. 3.1.1 Classic. Classic Ultra and Classic Ultra Select- Properties evaluated: Classic, Classic Ultra, and Classic Ultra Select are low- III Surface burning characteristics density, open-cell, polyurethane foam plastic insulations and air barrier systems that are 100 percent water-blown ■ Physical properties with an installed nominal density of 0.5 pcf ■ Therrlal performance(R-values) (8 kg/m3). The Insulations are two-component, spray- applied products.The two components of the insulation are ■ Attic and crawl space installation polymeric Isocyanate (A-Component, also known as Base ® Fire-resistance-rated construction Classic and proprietary resin (B-Component, Classic, Classic Ultra or Classic Ultra Select Resin).When stored * Air permeability at temperatures between 50°F (10°C) and 100°F (381C), ■ Exterior walls of Types I-N construction the components have a shelf life of six months. 3.1.2 Classic Pius: The Classic Plus foam plastic 1.2 Evaluation to the following green sbndard: insulation Is two-component,low density,open cell,spray- 2008 ICC 700 National Green Building Standardlu applied, foam plastic with a nominal density of {ICC 700-2008) 0.7 pat(11 kg/m3).The polyurethane foam Is produced by combining a polymeric isocyanate (A component) and Attributes verified: proprietary resin, Classic Plus (B component). When stored at temperatures between 50OF (10°C) and 100OF See Section 2.0. (384C),the components have a shelf life of twelve months. 2.0 USES 3.2 Surface Burning Characteristics: Classic, Classic Ultra, Classic Ultra Select, and Classic 3.2A Classic, Classic Ultra and Classic Ultra Select: Plus are used to provide thermal insulation in buildings and When tested in accordance with ASTM E84/UL 723, at a ICC_ES Elaluadon Reports arc not to be cmUMW as rcpresm ter om1hetics or my odw amibwo not apec$cnny addressed,nor me duy to be covwnred as an endorsement ofdhesubject oftherepmt or a reeommendadonfor its um here is no aaw'mny by ICCBvaluaaon Service,=zrprss orimpued,as {f to orryfindh+g or other matter in dds report or as to arty product covered by the repine b-=•• Copyright®2021 ICC EvaiwWon service,LLC. All dii is reserved. Pagel of 7 ESR-1826 I Most Widely Accepted and Trusted Page 2 of 7 thickness of 6 inches (152 mm)and a nominal density of is wet,or covered with frost or Ice,loose scales,rust,oil or 0.5 pcf(8 kg/m3), Classic, Classic Ultra and, Classic Ultra grease. The foam plastic insulation must not be used in Select have a flame spread index of 25 or less and a electrical outlet or junction boxes or in contact with rain or smoke-developed index of 460 or less. There is no water,and must be protected from the weather during and thickness limit when Installed behind a code-prescribad after application. Where the Insulation Is used as air- 15-minute thermal barrier, except as noted In Section impermeable insulation, such as in unvented attic spaces 4.3.12 and Table 2. regulated by 2021 and 2018 IBC Section 1202.3(2015 IBC 3.2.2 Classic Plus: When tested In accordance with Section 1203.3) or 2021, 2018, 2015 and 2012 IRC ASTM E841UL 723, at a thickness of 4 inches (152 mm) Section R806.5(2009 IRC Section R806.4), the insulation and a nominal density of 0.7 pof(11 kg/m3), Classic Plus must be Installed at a minimum thicknesses noted in has a flame spread index of 25 or less and a smoke- Section 3.4.The insulation can be Installed In one pass to developed Index of 450 or less.There Is no thickness limit the maximum thickness. Where multiple passes are when installed behind a code-prescribed required,the cure time between passes is negligible. 15-minute thermal barrier, except as noted In Section 4.2.2 Classic, Classic Ultra and Classic Ultra Select: 4.3.1.2 and Table 2. The Insulation must be used in areas where the maximum 3.3 Thermal Resistance: service temperature is no greater than 180°F(82°C). The Classic, Classic Ultra, Classic Ultra Select and Classic Insulation must be applied when the temperature is at or above Plus have thermal resistance (R values) at a mean F (- and be protected from the weather temperature of 75°F(24°C)as shown In Table 1. during and afterr application. 3A Air Permeability: 4.2.3 Classic Plus: The Insulation may be used In areas where the maximum service temperature Is no greater than Huntsman Building Solutions LLC spray-applied foam 180°F (82°C). The insulation must be applied when the plastic Insulations are considered alr-Impermeable temperature is at or above 14°F(10°C)and be protected Insulation in accordance with 2021 and 2018 iBC Section from the weather during and after application. 1202.3 (2015 iBC Section 1203.3)and 2021, 2018, 2015 and 2012 IRC Sections R202 and R806.5 (2009 IRC 4.3 Thermal Barrier. Sections R202 and R806.4),at the following thicknesses: 4.3.1 Classic, Classic Ultra, Classic Ultra Select and ■ Classic, Cliassic Ultra and Classic Ultra Soled: Classic Plus: Minimum, 3 Inches (76 mm) based on testing in 4.3.1.1 Application with a Prescriptive Thermal accordance with ASTM E2178. Barrier. Classic, Classic Ultra, Classic Ultra Select and ■ Classic Plus: Minimum, 2 inches (51 mm) based on Classic Plus foam plastic insulations must be separated testing in accordance with ASTM E2178, from the interior of the building by an approved thermal 3.6 Intumescent Coatings: barrier, such as Y.-inch (12.7 mm) gypsum wallboard installed using mechanical fasteners In accordance with 3.6A No Bum Plus XD: No Bum Plus XD Intumescent the -applicable code, or an equivalent coating Is a latex-based coating supplied In 1-gallon (4L) 15-minute thermal barrier complying with the applicable and 5-gallon(19L)palls and 55-gallon(208 L)drums.The fie.When installation is within an attic or crawl space as coating material has a shelf life of 12 months when stored described in Section 4.4, a thermal barrier is not required in factory-sealed containers at temperatures between 40°F between the foam plastic and the attic or crawl space,but (4.4°C)and 90°F(32.20C). is required between the foam plastic insulation and the 3.6.2 DC 315 Coating: DC 315 coating ESR-3702, interior of the bull ding. There Is no thickness limit when manufactured by International Fireproof Technology, installed behind a code-prescribed 15-minute thermal International Inc./Paint To Protect Inc., is a water-based barrier,except as noted in Section 4.3.12 and Table 2. Intumescent coating supplied In 5-gallon (19L) pails and 4.3.1.2 Application without a Prescriptive Thermal 55-gallon (208L)drums. The coating material has a shetf Barrier or Ignition Barrier. The prescriptive 15-minute life of 12 months when stored in factory-sealed containers thermal barrier or ignition barrier may be omitted when at temperatures between 500F(10°C)and 80°F(270C). Installation is In accordance with the following 3.5.3 FireshelP F10E Coating: Flreshell®F10E coating, requirements: manufactured by TPR2 Corporation (ESR-3997), Is a 4.3.1.2.1 The Insulation must be covered on all surfaces water-based Intumescent coating supplied in 5-gallon(19L) with a fire protective coating at the minimum thickness set palls and 55-gallon(208L)drums.The coating material has forth In Table 2. e shelf fife of 12 months when stored In factory-sealed containers at temperatures between 45°F(7.20C)and 95°F 4.3.1.2.2 The maximum installed thickness of the (350C), Insulation must not exceed the thicknesses set forth in 4.0 INSTALLATION Table 2. 4.1 General: 4.3.1.2.3 The coating must be applied over the insulation The manufacturer's published installation instructions and In accordance with the coating manufacturer's instructions this report must be strictly adhered to and a copy of these and this report instructions and this evaluation report must be available on 4A Attics and Crawl Spaces: the jobsite at all times during installation. 4AA Classic,Classic Ultra and Classic Ultra Select: 4.2 Application: 4A.1.1 Application with a Prescriptive Ignition Baffler: 4.2.1 General:Classic,Classic Ultra, Classic Ultra Select When Classic,Classic Ultra and Classic Ultra Select foam and Classic Plus foam plastic Insulations must be applied plastic Insulations are Installed within attics where entry Is on the jobsite using two-component, 1-t0-1 ratio, spray made only for service of utilities,an ignition barrier must be equipment specified by Huntsman Building Solutions LLC Installed in accordance with IBC Section 2603.4.1.6 and The foam plastic must not be sprayed onto a substrate that IRC Sections R316.5.3 and R316.5A. as applicable. The , ESR-1826 J Most Widely Accepted and Trusted Page 3 of 7 ignition barrier must be consistent with the requirements foam plastic Is applied at a minimum thickness of for the type of construction raquired by the applicable code 3.5 inches (89 mm) as described in this section in and must be installed in a manner so that the foam plastic accordance with 2021 and 2018 IBC Section 1202.3(2015 insulation is not exposed. The Classic, Classic Ultra or IBC Section 1203.3)and 2021, 2018,2015 and 2012 IRC Classic Ultra Select Insulation may be installed in unvented Section R806.5(2009 IRC Section R806.4),as applicable. attics when the foam plastic is applied at a minimum 4.4.1.2.2 Attics--Classic Ultra and Classic Ultra thickness of 3 inches (76 mm) In accordance with 2021 Select: When Classic Ultra or Classic Ultra Select is and 2018 iBC Section 1202.3 (2015 IBC Section 1203.3) applied in unvented attics conforming to 2021 and 2018 or 2021, 2018,2015 and 2012 IRC Section R806.5 (2009 IBC Section 1202.3(2015 IBC Section 1203.3)and 2021, IRC Section R806.4),as applicable. 2018, 2015 and 2012 IRC Section R806.5 (2009 iRC 4.4.1.2 Application without a Prescriptive Ignition Section R806.4), the insulation may be applied to the Barrier: Where Classic, Classic Ultra and Classic Ultra underside of roof sheathing and/or rafters to a minimum Select foam plastic insulations are installed In an attic or thickness of 31/2 inches (90 mm) and may be applied to crawl space without a prescriptive ignition barrier, in vertical wall surfaces to a minimum thickness of 31/2 Inches accordance with Sections 4.4.1.2.1, 4.4.1.2.2. 4.4.1.2.3 (90 mm). Maximum thickness on the underside of roof and 4.4.12.4,the following conditions apply: sheathing or on vertical wall surfaces is 20 Inches 1. Entry to the attic or crawl space is only for service of (508 mm).The insulation may be left exposed to the attic utilities and no storage is permitted. without a prescriptive ignition barrier or an intumescent coating. 2. There are no interconnected attic, crawl space or basement areas. The attic must have attic access complying with !RC Section R807,horizontally placed in the floor,and opening 3. Air in the attic or crawl space is not circulated to other outward toward the living space.Items penetrating the roof parts of the building. deck or walls, such as skylight wells and vents, must be 4. Combustion air is provided In accordance with IMC covered with a minimum of 3112 Inches (90 mm) of the Section 701. Classic Ultra or Classic Ultra Select insulation. 5. Attic ventilation is provided when required by 2021 4A.1.2.3 Crawl Spaces: In crawl spaces, Classic, and 2018 IBC Section 1202.2 (2015, 2012 and 2009 Classic Ultra or Classic Ultra Select insulations may be IBC Section 1203.2) or IRC Section R806, except spray-applied to vertical walls and the underside of floors, when alr4mpermeable Insulation is permitted in as described in this section. The thickness of the foam unvented attics In accordance with 2021 and 2018 plastic applied to the underside of the floors must not IBC Section 1202.3 (2016 IBC Section 1203.3) or exceed 14 Inches (356 mm). The thickness of the spray 2021, 2018. 2016 and 2012 IRC Sectlon R806.5 foam plastic insulation applied to vertical wall surfaces (2009 IRC Section R806.4),as applicable. must not exceed 31/2 inches(88.9 mm). The foam plastic 6. Under-floor(crawl space)ventilation Is provided when does not require an Ignition barrier or a coating. required by 2021 and 2018 IBC Section 1202.4 4.4.1.2.4 Use on Attic Floors:When used on attic floors, (2015 iBC Section 1203.4 or 2012 and 2009 IBC Classic, Classic Ultra or Classic Ultra Select foam plastic Section 1203.3)or IRC Section R408.1,as applicable. Insulations may be installed at a maximum thickness of 11112 inches (292 mm) between Joists In attic floors. The 4A.1.2.1 Attics--Classic, Classic Ultra and Classic Ultra Select: In attics, Classic, Classic Ultra and Classic insulation must separated from the Interior of the building by an approved thermal bonier. The coatings Ultra Select foam plastic insulations may be spray-applied specified in Section 4A.1.2.1 and the ignition barrier in to the underside of the roof sheathing and/or rafters, as accordance with IBC Section 2603.4.1.6 and IRC Section described in this section.The thickness of the foam plastic R316.5.3,may be omitted. applied to the underside of the roof sheathing must not exceed 14 inches (356 mm). The thickness of the spray 4.4.2 Classic Plus: foam insulation applied to vertical wall surfaces must not 4A.2.1 Application with a prescriptive Ignition Barrier: exceed 5.5 Inches (140 mm). The Insulation must be When Classic Plus Is installed up to a maximum thickness covered on all surfaces with one of the coatings described of 4 inches(102 mm)within attics or crawl spaces where In Section 3.5. The coating must be applied over the entry is made only for service of utilities,an Ignition barrier Insulation In accordance with the coating manufacturer's must be Installed In accordance with IBC Section Instructions and this report.Surfaces to be coated must be 2603.4.1.6 and IRC Sections R316.5.3 and R316.5.4, as dry, clean, and free of dirt, loose debris and other applicable.The ignition barrier must be consistent with the substances that could interfere with adhesion of the requirements for the type of construction required by the coating. The coating is applied In one coat with low- applicable code and must be Installed in a manner so that pressure aldess spray equipment. The coating must be the foam plastic Insulation is not exposed. Classic Plus applied to a thickness as follows: may be Installed In unvented attics when the foam plastic ■ No Bum Plus XD at a minimum thickness of 6 wet mils is applied at a minimum thickness of 2 Inches(51 mm) In (0.15 mm) [4 dry mils (0.1 mm) dry film thickness), accordance with 2021 and 2018 IBC Section 1202.3(2015 applied at a rate of 0.4 gallon (1.5 L) per 100 square IBC Section 1203.3)and 2021, 2018,2015 and 2012 IRC feet(9.2 m2). Section R806.5(2009 IRC Section R806.4),as applicable. ■ DC 315 at a minimum thickness of 4 wet mils(0.1 mm) 4A.2.2 Application without a Prescriptive Ignition [3 dry mils], applied at a rate of 0.3 gallon (1.1 I-) per Barrier: Where Classic Plus insulation is installed in 100 square feet(92 m2). accordance with Sections 4.4.32.1, 4A.3.2.2, and The coatings must be applied when ambient and 4.4.3.2.3,the following conditions apply: substrate temperature Is at least 60OF(16°C)and no more 1. Entry to the attic or crawl space is to service utilities, than 95OF(350C).All other surfaces(including glass)must and no storage is permitted. be protected against damage from the coating. .The 2. There are no interconnected attic or crawl space Insulation may be Installed In unvented attics when the areas. ESR-1826 I Most Widely Accepted and Trusted Page 4 of 7 3. Air In the attic or crawl space Is not circulated to other (38 mm by 89 mm)]southern pine(G=0.55),No.2 grade parts of the building. studs spaced 16 inches (406 mm)on center with a base 4. Combustion air is provided in accordance with IMC layer of 1/2-inch-thlck (12.7 mm)wood fiber sound board Section 701. Installed horizontally on- each face with vertical joints located over the studs,attached with 6d box nails,2 inches 5. Attic ventilation is provided when required by 2021 (51 mm) long and spaced 24 inches (610 mm)on center and 2018 IBC Section 1202.2(2015,2012, and 2009 along the studs, and a second layer of 5/a-inch-thick iBC Section 12032) or IRC Section R806, except (16.9 mm)Type X gypsum wallboard installed vertically on when air-Impermeable insulation Is permitted in each face,attached with 8d box nails,21/2 Inches(64 mm) unvented attics 1n accordance with 2021 and 2018 long and spaced 7 inches (178 mm) on center along the IBC Section 1202.3 (2015, 2012 and 2009 IBC studs. The stud cavity contains Classic, Classic Ultra or Section 1203.3) or 2021, 2018, 2015 and 2012 IRC Classic Ultra Select Insulation nominally 2 inches(51 mm) Section R806.5 (2009 IRC Section R806.4), as thick. applicable. 6. Under-floor(crawl space)ventilation Is provided when Axial loads applied to the wall assembly must be limited to the least of the following: required by 2021 and 2018 ISC Section 1202.4 (2015 IBC Section 1203.4 and 2012 and 2009 IBC ■ 1,805 pounds(8029 N)per stud. Section 1203.3)or IRC Section R408.1,as applicable. ■ Design stress of 0.78 Pc. 4.4.2-2.1 Attics: In attics, Classic Plus Insulation may be 0 Design stress of 0.78 Pc at a maximum leld of 33. sprayappiled to the underside of the roof sheathing and/or rafters,the underside of wood floors,and vertical surfaces, 4.5.1.2 Assembly 2(Limited Load-bearing Wood Stud as described in this section. The thickness of the foam Wall): Minimum 'nominally 2-by-4 [1112 by 3112 inches plastic applied to the underside of the top of the space (38 mm by 89 mm)]southern pine(G=0.55),No.2 grade must not exceed 14 inches(356 mm).The thickness of the studs spaced 16 inches (408 mm) on center with two spray foam plastic Insulation applied to vertical wall layers of 1/24nch-thick (12.7 mm) Type X gypsum surfaces must not exceed 8 Inches wallboard installed vertically with joints staggered on each (203 mm).The foam plastic Insulation must be covered on face,attached with 8d box nails, 21/2 Inches(64 mm)long all exposed surfaces with DC315 Intumescent coating at a and spaced 7 inches(178 mm)on center along the studs minimum thickness of 4 wet mils (0.1 mm) 13 dry mils for the face layer and 6d cement coated box nails,2 inches (0.08 mm)], applied at a rate of 0.25 gallon (0.95 L) per (51 mm)long and spaced 24 inches (610 mm)on center 100 square feet(9.2 m2).The coating must be applied over along the studs.The stud cavity contains Classic, Classic the Classic Plus Insulation in accordance with Ultra or Classic Ultra Select insulation nominally the coating manufacturer's instructions and this report 2 Inches(51 mm)thick. Surfaces to be coated must be dry,clean, and free of dirt, Axial loads applied to the wall assembly must be limited loose debris and other substances that could interfere with to the least of the following: adhesion of the coating.The coating is applied in one coat with low-pressure airless spray equipment ■ 1,805 pounds(8029 N)per stud. The coating must be applied when ambient and ■ Design stress of 0.78 Fc. substrate temperature is at least 60"F(16°C)and no more Design stress of 0.78 Pc at a maximum Io/d of 33. than 95 F(35 C).All other surfaces(including glass)must 9 be protected against damage from the coating. 4.6.1.3 Assembly 3 (Floor/Celling): Minimum nominally Classic Pius Insulation may be installed in unvented 2-by-10[11/2 by 91/4 inches(38 mm by 235 mm)]Douglas attics when the foam plastic Is applied at a minimum Or,No.2 grade wood joists spaced 24 Inches(610 mm)on thickness of 2 inches(51 mm)as described in this section, center, with minimum 1-by-3 PA by 21/2 Inches (19.1 by In accordance with 2021 and 2018 IBC Section 1202.3 64 mm)] spruce bridging at mid-span. Floor decking (2015 IBC Section 1203.3) and 2021, 2018, 2015 and must be minimum 1/2-inch-thick (12.7 mm) exterior grade 2012 IRC Section R806.5 (2009 iRC Section R806.4), as plywood Installed perpendicular to joists and fastened with applicable. 2-Inch-long(51 mm)ring shank nails 6 inches(152 mm)on 4A.2.2.2 Crawl Spaces: In crawl spaces, Classic Plus center at the joints and 12 Inches (305 mm)on center at Insulation may be spray-applied to vertical walls and the the Intermediate joists. Plywood joints must occur over underside of floors, as described in this section. The joists. Classic, Classic Ultra or Classic Ultra Select thickness of the foam plastic applied to the underside of Insulation must be applied to the underside of the plywood floors must not exceed 14 inches deck between the joists to a depth of 5 Inches(127 mm). the the floors The thickness of the spray foam plastic Two layers of minimum 5/a-Inch-thick (15.9 mm), Type X insulation applied to vertical wall surfaces must not exceed gypsum wallboard must be attached perpendicular to the 8 Inches(203 mm). The Insulation must be covered with joists on the ceiling side the assembly. The first layer DC�15 coating as described In Section 4.4.2.2.1. must be attached with 1 1/!a-Inch-long (32 mm), Type W drywall screws,spaced 24 Inches(610 mm)on carder.The 4A.2.2.3 Use on Attic Floors: Classic Plus insulation second layer must be applied perpendicular to the joists, may be installed at a maximum thickness of offset 24 Inches(610 mm)from the base layer.The second 13 Inches (330 mm) between joists in attic floors. The layer must be attached with 24nch4ong (51 mm), Type S Insulation must be separated from the interior of the drywall screws spaced 12 Inches (305 mm) on center. building by an approved thermal barrier. The insulation Additional fasteners must be Installed along the butt joints does not require an ignition barrier or a coating. of the second layer, securing the two layers together. 4.6 One-hour F{re-ces{stance4sted Assemblies: These fasteners must be 11/2-Inchlong(38 mm), Type G 4.6.1 Classic,Classic Ultra and Classic Ultra Select: drywall screws placed 2 Inches (51 mm) back from each end of the butt joint and spaced 12 inches (305 mm)on 4.5.1.1 Assembly 1 (Limited Load-bearing Wood Stud center.The wallboard joints on the exposed side must be Wall): Minimum nominally 2-by-4 [11/2 by 31/2 inches treated with paper tape embedded In joint compound and ` e ESR-1826 1 Most iMdslyAccepted and Trusted Page 5 of 7 topped with an added coat of compound,and the fastener 6.1 This evaluation report and the manufacturer's heads must be coated with joint compound In accordance published installation Instructions, when required by with ASTM C840 or GA-216. the code offlclsl, must be submitted at the time of 4.6.1A Assembly 4(Non-loadbearing Steel Stud Wall): permit application. Nominally 6-inch-deep (152.4 mm), No. 18 gage, 6.2 The insulation must be installed in accordance with galvanized steel studs spaced 16 inches (406.4 mm) on the manufacturer's published installation instructions, center, are friction-fit into No. 18 gage galvanized steel this evaluation report and the applicable code.If there floor and ceiling track with a layer of 5/8-inch4hick Is a conflict between the installation Instructions and (15.9 mm),Type X gypsum board applied to the interior this report,this report governs. side with the long edge parallel to steel studs and secured 5.3 The insulation must be separated from the Interior of using No. 6, 1 1/4-inch-long (31.7 mm), self-drilling drywall the building by an approved 15-minute thermal screws spaced 8 Inches (203 mm) on center around the barrier,except as noted In this report. perimeter and 12 inches(305 mm) on center In.the fleid. The gypsum board joints must be treated with vinyl or 6.4 Since the performance of Classic Ultra and Classic casein, dry or premixed joint compound applied in two Ultra Select when Installed In unvented attics without coats to cover all exposed screw heads and gypsum board a code-prescribed Ignition barrier or an Intumescent butt joints, and a minimum 2-Inch-wide (51 mm) paper, coating,Is based on fire performance of an unvented plastic, or fiberglass tape embedded In the first layer of attic, the installation must be approved by the code compound over butt joints of the gypsum board.The stud official as conforming with the provisions of Section cavity is filled with Classic, Classic Ultra or Classic Ultra 4.4.1.2.2 and Conditions 1 to 5 of Section 4A.1.2. Select insulation up to 6 Inches (162 mm) thick. 5.5 When Classic Ultra and Classic Ultra Select Insulation DensOlass®Exterior Sheathing,1/2 Inch(12.7 mm)thick,Is Is installed under Section 4A.1.2.2 of this report, a Installed parallel to steel studs with vertical joints offset a certificate must be placed in the attic stating that the minimum of 16 Inches(406 mm)from the vertical joints of foam plastic insulation has been installed in the gypsum board and the horizontal joints offset a accordance with Conditions 1 through 5 of Section minimum of 24 Inches(610 mm)from the horizontal joints 4A.12 and the terms of Section 4A.1.2.2 of of the gypsum board. The sheathing is attached using ESR-1826; any alterations to the attic or Insulation No.6,11144nch-long(31.7 mm),self-drilling drywall screws must be consistent with those requirements. spaced 8 inches(203 mm)on center around the perimeter and In the field. Hohmann $ Barnard DW-10 brick ties, 6.6 The Insulation must not exceed the thicknesses and 6 inches(152 mm)long by 11/2-anches(38 mm)wide; are densities noted in this report. spaced 16 Inches(406.4 mm)on center vertically on each 6.7 The Insulation must be protected from the weather steel stud,and secured,using two 15/a-inch-long(41.3 mm) during and after application. self-drilling screws,through 4-inch(102 mm)red day brick [31/2 Inches (88.9 mm) by 21/4 inches (57.1 mm) by 6.8 The insulation must be applied by Huntsman licensed dealers 75/4 Inches(197 mm)] laid In a running bond pattern with and installers certlfled by Hunttsman Building Type S mortar, leaving a nominally 1-Inch (25.4 mm)air Solutions LLC. gap between the brick and the exterior sheathing. 6.9 Use of the Insulation In areas where the probability of Optional: It is permitted to add code-complying, termite infestation Is °very heavy' must be in expanded polystyrene(EPS),extruded polystyrene(XPS), accordance with IRC Section R318.4 or IBC Section foil-faced, rigid polyurethane board stock or polyurethane 2603.8.as applicable., spray foam on the exterior of the wall (between the 5.10 Jobsite certification and labeling of the Insulation must DensGlas& sheathed wail and the brick), while comply with 2021, 2018, 2015 IRC Sections maintaining the 1-inch(25.4 mm)air space.The length of N1101.10.1 and N1101.10.1.1 (2012 IRC Sections the brick ties must be increased to account for the N1101.12.1 and N1101.12.1.1 or 2009 iRC Sections thickness of the Insulation. N1101.4 and N1101.4.1) and 2021, 2018 2015 and 4.6 Exterior Walls In Type 1.It,Ill and IV Construction: 2012 IECC Sections C303.1.1, C303.1.1.1, R303.1.1 and R303.1.1.1 (2009 IECC Sections 303.1.1 and 4.6.1 General.When used on exterior walls of Types 1,II, 303.1.1.1),as applicable. III or IV construction,the assembly must comply with 2018, 2015,2012,and 2009 IBC Section 2603.5 and this section, 6.11 A vapor retarder must be Installed in accordance with and the Classic, Classic Ultra and Classic Ultra Select the applicable code. Insulations must be installed at a maximum thickness 6.12 Classic, Classic Ultra, Classic Ultra Select and described in Table 3. The potential heat of Huntsman Classic Pius foam plastic Insulations are Building Solutions Insulations tested in accordance with manufactured in Mississauga, Ontario, Canada and NFPA 259 Is as follows: Arlington,Texas,under a quality control program with ■ Classic, Classic Ultra and Classic Ultra Select. inspections by ICC-ES. 494 Btu/ft2(5.6 MJ/rn2)per inch of thickness 6.0 EVIDENCE SUBMITTED 4.6.2 Specific Wall Assemblies: Wall assemblies 6.1 Data In accordance with the [CC-ES Acceptance complying with Section 4.6 must be as described in Criteria for Spray-applied Foam Plastic Insulation Table 3. (AC377), dated April 2020 (Editorially revised July 6.0 CONDITIONS OF USE 2020). The Classic,Classic Ultra,Classic Ultras Select and Classic 6.2 Reports of tests in ecoordancs with AC377 Appendix Plus spray-applied polyurethane foam plastic Insulations X [Classic, Classic Ultra and Classic Ultra Select described In this report comply with, or are suitable (Section 4A.12.1) and Classic Plus (Sections alternatives to what is specified in, those codes listed in 4.4.32.1 and 4A.32.3)] and Appendix C [Classic, Section 1.0 of this report, subject to the following Classic Ultra and Classic Ultra Select (Section conditions: 4.4.12.3)]. ESR-1826 I Most Iffidely Accepted and Trusted Page 6 of 7 6.3 Test report on air leakage rate in accordance with smoke-developed Index; the expiration date; the ASTM E2178(Classic, Classic Ultra and Classic Ultra name of the Inspection body (ICC-ES); and the Select and Classic Plus). evaluation report number(ESR-1826). 6A Reports of room comer fire testing in accordance with No Bum Plus XP Intumescent coating described in NFPA 286(Classic,Classic Ultra,Classic Ultra Select Section 3.5.1 is identified with the manufacturers and Classic Plus). name and address, the product trade name and use 6.5 Test reports in accordance with ASTM E119(Classic, instructions. Classic Ultra and Classic Ultra Select). The International Fireproof Technology, Inc./Paint 6.6 Test report in accordance with NFPA 285,and related To Protect Inc. DC 315 coating described In Section engineering analysis (Classic, Classic Ultra and 3.5.2 is identified with the manufacturer's name and Classic Ultra Select). address, the product trade name, date of manufacture, shelf life or expiration date, the 6.7 Reports of tests In accordance with NFPA 259 manufacturer's application Instructions and the (Classic,Classic Ultra and Classic Ultra Select). evaluation report number(ESR-3702). 6.8 Reports of fire tests in accordance with ASTM E970 Flreshell F10E coating is labeled with the (Classic, Classic Ultra, Classic Ultra Select and manufacturers name and address;the product name; Classic Plus). the date of manufacture; the shelf life or expiration 6.9 For Classic Ultra and Classic Ultra Select, an date; the manufacturer's Instructions for application; engineering evaluation,Including full-scale fire testing, and the evaluation report number ESR-3997 . small-scale testing and fire modeling (Section 7.2 The report holders contact information Is as follows: 4.4.12.2). HUNTSMAN BUILDING SOLUTIONS LLC 7.0 IDENTIFICATION 3315 E.DIVISION STREET 7.1 All packages and containers of Classic,Classic Ultra, ARLINGTO 0 TEXAS 76011 Classic Ultra Select and Classic Plus Insulations must www hunts a be labeled with the Huntsman Building Solutions LLC w�vw•huntsmanbtttlding.com name and address; the product name; component designation(A or B);the flame spread Index and the TABLE 1—THERMAL RESISTANCE(R VALUES) R-VALUE(-F-fe-hBtu) THICKNESS Classic,Classic Ultra and Classic Plus (inches) Classic Ultra Select 1 3.7 4.0 2 7.4 8.0 3 11 12 3.5 13 14 4 14 16 5 18 20 5.5 20 22 6 22 24 7 25 28 7.5 27 30 8 29 32 9 32 36 9.5 34 38 10 36 40 11.5 41 42 13.5 54 14 50 56 For SI: 1 inch=25.4 min,1'F•ftZfifBtu=0.1761101K•m21W. W-Values are calculated based an tested K values at 1-and 3.64rtch Wckneseea. 2R-velues greater than 10 are rounded to the nearest whole number. ESR 1826 I Most IKrdelyAccepted and Trusted Page 7 of 7 TABLE 2—USE OF INSULATION WITHOUT A PRESCRIPTIVE THERMAL BARRIERS MAXIMUM MAXIMUM RE-PROTECTIVE COATING MINIMUM THEORETICAL INSULATION TYPE THICKNESS On.) THICKNESS(In.) MINIMUM THICKNESS& APPLICATION TESTS (Walls 3 Vertical (Ceilings;Underside of Roof TYPE(Applied to all Foam RATE OF FIRE- SUBMITTED Surfaces) SheathinglRafters&Floors) Surfaoes)2 PROTECTIVE COATING' CLASSIC,CLASSIC 8% 14 14 mlis DC315%9 mAs DF�i 0.88 gal/100 flz NFPA 286 ULTRA AND CLASSIC ULTRA S Flreshall F10E SELECT 7/2 11/2 21 mils W FT 114 rolls DFT 1.31 gal/100 ft2 NFPA 286 CLASSIC PLUS 81/2 14 DC315 0.88 gal/100 42 NFPA 286 14 mile WFT 19 mils DFT For Sh 1 Inch=25.4 mm;1 mil=0.0254 mm;1 gallon=3,38 L;1 ft2-D.093 m2;NA=not applicable. 'See section 4.3.12. 'See Sections 3.5.2 and 3.5.3. °As reported In the manuhchW& application instructions.Actual appitcation rate, based on speeiflc project conditions, must be In sccordance with the manufacturer's application Instructions. TABLE 3--NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES'-' WALL COMPONENT MATERIALS Base Wag System- 1- Concrete wall. Use either 1,2 or 3 2- Concrete masonry well. 3- Minimum 35/e4nch-deep(92 mm), No. 20 gage, Cshoped steel studs,spaced a maximum of 24 inches on center with lateral bracing every 4 feet(1219 mm)as required by code.Sheathing shag be a described in Exterior Sheathing below. Floorline Firestopping Minimum 4 pd mineral woof in each stud cavity at each floorline,attached with Z-clips.Thickness must match stud cavity depth. Cavity Insulation- 1- None. Use either 1,2,3,41 or 5 2- Partial cavity fill with a maximum air space of 2 Inches(51 mm)or full cavity depth trot exceeding r1e inches(194 mm)of Classic,Classic Plus,Classic Ultra or Classic Ultra Soled(ESR-1826); MD-R-210(ESR-3493};MD-0-200(ESR-3199);or Proseal(ESR-3500). 3- Any Insulation qualified as noncombustible in accordance with ASTM E136. 4- Glass fiber bolt insulation•. 5- Mineral fiber Insulation'. a,Insulation must comply with the applicable requirements of 2018,2015 or 2012 IBC Section 720.2(2009 IBC Section 719.2). Exterior Sheathing-Only for Base Wall 1- Minimum Vz-fnch-thick(12.7 mm),),glass mat gypsum sheathing complying with ASTM C1177. System No.3 2- Sheathing shall be attached with No. 6, 1114- inc-long (32 mm)self-fapping screws located Use either 1 or 2 8 Inches(203 mm)on center along the perimeter and 12 Inches 302 mm)on center In the field of wallboard. Joints must be taped and treated with joint compound in accordance with ASTM C840 or GA-216. Exterior Insulation Maximum thickness of 51/2 Inches (140 mm) of Proseal Eco (MD-R 210) (ESR-3493)or Proseal (ESR-3500). Exterior Wag Covering- i- Brick-standard nominally 4-Inch-thick(102 mm)clay brick; brick veneer anchors-standard Use either 1,2,3,4,5,6 or 7 types Installed a maximum of 24 Inches OC vertically on each studb. 2- Stucco-minlrnrun 3/44rhch-thick(19.1 mm),exterior cement plaster and lath with a secondary water-resistive barrier may be installed between the exterior Insulation and the lath. 3- Natural stone(limestone,granite,marble,sandstone),minimum 2-inch-thick(51 mm)'. 4- Cast artificial stone, minimum 1'/2-tnch-thick(38 mm),complying with AC51 and subject of a cement ICC-ES evaluation report°. 5- Terracotta cladding,minimum of 1'Lr-inch-thick(32 mm),. 6- Precast concrete panels,minimum of 1'/2-4nch-thlck(32 mm)°. 7- Concrete masonry units(CMU),minknum of 1'/24ncrtidck(38 mm)°. °The maximum el gap between exterior Insulation and cladding shall be 2Inches(51 mm). '-Any standard non-open-Jointed Installation technique such as ship-lap,etc.,may be used. S When used on exterior walls of Types I,II,III or IV construction,the speclflc wail assembly must comply with 2018,2015, 2012,and 20M IBC Section 2603.5. 2 The exterior wall assemblies described in Table 3 comply with 2018,2015,2012-and 2009 IBC Section 2603.5.5. .'Y SolarSkylights HOME > ROOF WINDOWS > TOP HINGED ROOF WINDOW > VELUX 37-5/8 IN.X 63-1/2 IN.TOP HINGED ROOF WINDOW-GPU-PK10 VELUX 37-5/8 IN. X 63-1 /2 IN. TOP HINGED ROOF WINDOW - GPU-PK10 - - " *****Write a review Brand: VELUX fif $1,243.00 PayPa! Pay in 4 interest-free payments of$3, I' t SKU: GPU-0060R-37x63 Shipping: FREE Shipping! (Estimated Arrival: 7-10 days) "Y Z7 m /` �7-/ 7/ GPU - Flashing Options: m ---r Please choose an option to add this produc * GPU Acessories: Please choose an option to add this produc 1 v 1 1 1 TrustedSite` CERTIFIED SECURE OTHER TOP RATED PRODUCTS 4.3**fit*4 Google Customer Reviews _ r < i M. > Solar Night Light VELUX 21 in.x 45-3/4 in. ... VELUX 14-1/2 in.x 46-1/... VELUX 22-1/2 $32.00 $642.00 $172.90 $194.00 Powered by 0 Reviews Write A Review m m BE THE FIRST TO WRITE A REVIEW Ln Overview Specifications Info&Guides Related Items MORE NATURAL LIGHT AND FRESH AIR Put fresh air at your fingertips with a top hinged VELUX roof window.A top hinged roof window is easy to operate -even with furniture beneath. The innovative top control bar allows you to install the window lower than an equivalent bottom-operated window to get an excellent view while standing and when seated. We recommend top hinged windows if you have to, or wish to, place your window in a low position, for instance: in rooms with a low ceiling or where you'd like a better view of the surroundings below. WATCH THE OPERATION 4.3**rA-i:- Googla Customer Reviews 0:00 /0:12 > Enjoy panoramic views -while increasing your energy efficiency and natural ventilation > Convenient bottom handle for operation > Increase the amount of natural light in your rooms BENEFITS OF TOP HINGED ROOF WINDOWS m m LA f a 1O v ThermoTechnologyTM I f i 20 v Natural ventilation ' l (3� How to clean your window 4.3****1!,, Go4gle Customer Reviews Blinds PRICE RANGE FOR SINGLE TOP HINGED ROOF WINDOW INSTALL With a small investment, you can dramatically transform any room in your home with daylight and fresh air. In the long run, installing roof windows will help you save on your utility bills. Costs vary depending on the number of roof windows and your ceiling type. View all price ranges m m Ln 4.3 ;`; Google Customer Reviews New Skylight. $-2r150 - 2 7a ReplacementSkylight m 1= 11 r 2 .5 0 - $ 1r650 ROOF WINDOW SIZES GPU Size Code CK04 CK06 MK04 MK06 MK08 PK10 Outside frame (W'W") 21%x 21%x 303/4 x 303/4 x 303/4 x 371/8) 4.3 38 1/2 46% 38 1/2 46% 55 63 Gaagle Customer Reviews - _ Rough opening/Finished frame (W"xH") 221/8 x 221/8 x 311/4 x 311/4 x 311/4 x 37%) 39 46 7/8 39 46 7/8 55 1/2 63 1/2 EXCELLENT ENERGY EFFICIENCY Experience a more comfortable home and lower energy bills with VELUX ThermoTechnologyTm. Innovative use of high performance materials in the window construction provides excellent energy efficiency, insulation and an airtight seal. Look for the ThermoTechnologyTm seal for your guarantee of excellent energy efficiency. m m 4.3 0 s Google f NATURAL VENTILATION - WITH A CLOSED WINDOW Let fresh air into your home even when you are away or sleeping, without having to worry about security or bad weather. Pull the unique top control bar once and you will allow fresh, filtered air to enter through the ventilation flap. � I 1 1 w i m ENJOY FRESH, CLEAN, FILTERED AIR The built-in air filter improves the indoor climate by preventing dust and insects from entering your home. The filter is reusable and easy to clean. ARE YOU READY TO BUY? Shop Now Get in Touch 4.3c* ;`: Goggle Customer Reviews CONNECT WITH US CATEGORIES BRANDS NEWSLETTER f Q Solar Skylights VELUX First Name Electric Skylights Babcock-Davis --- Manual Skylights Acudor FEmail FURTHER INFO Fixed Skylights Fakro Sun Tunnels VELUX SUN TUNNEL Reviews Roof Windows View all brands Damage Policy Contact Us Privacy Policy_ Returns and Refunds Policy Shipping Policy_ Skylight Product ID Terms of Use Velux Tax Credit Information Sitemap �!lNtER[CAN oiscUVER amazon '' Pa pa, EXPRESS NETWORK payments '� Y M 1 -- In All prices are in USD.©2021 SolarSkylights.com Sitemap I Shopping Cart Software by Bigcommerce 4.3 *1"- Google Customer Reviews "� WINDOW &DOOR MANUFACTURERS ASSOCIATION 1 August 24, 2020 TO: Mike Rhoden Regulatory Compliance Manager VELUX America Inc. PO Box 5001 Greenwood,SC 29648 RE:WDMA Hallmark Certification Program—Emergency Escape and Rescue—Approval No.TP01-021815 Approval No.TP02 082420 This letter is being written to verify the compliance with the building code Emergency Escape and Rescue Egress Openings requirements for some VELUX America, Inc. Products. The 2018 IRC Code Section R 310.2 and the IBC Section 1030.2 and state the emergency escape and rescue openings requirements. 2018 IRC R310.2 Emergency escape and rescue openings.Emergency escape and rescue openings shall have minimum dimensions as specified in this section. R310.2.1 Minimum opening area.Emergency and escape rescue openings shall have a net clear opening of not less than 5.7 square feet(0.530 m2).The net clear opening dimensions required by this section shall be obtained by the normal operation of the emergency escape and rescue opening from the inside.The net clear height of the opening shall be not less than 24 inches (610 mm)and the net clear width shall be not less than 20 inches(508 mm).Exception: Grade floor openings or below-grade openings shall have a net clear opening area of not less than 5 square feet(0.465 m2). 2018 IBC 1030.2 Minimum size.Emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.53 m2).Exception:The minimum net clear opening for gradefloor emergency escape and rescue,openings shall be 5 square feet(0.46 m2). 1030.2.1 Minimum dimensions.The minimum net clear opening height dimension shall be 24 inches(610 mm).The minimum net clear opening width dimension shall be 20 inches(508 mm).The net clear opening dimensions shall be the result of normal operation of the opening The two VELUX,America, Inc. Roof Window Products covered by this letter in the following sizes were found to comply with the Emergency Escape and Rescue Egress Openings Requirements under certain installation conditions compliant with the building code limitations and the products are the GPU MK06, GPU SK06, GPU MK08, GPU UKO% PU PK10 nd the GXU FK06. (See attached drawings.) VELUX,America, Inc. is a licensee in the Window and Door Manufacturers Association Hallmark and NFRC programs. Please let me know if you have any additional questions. I can be reached at (312) 673- 4828 or via email at jmcfee@wdma.com. Sincerely, Y6A_"-I- John McFee V.P. Certification Programs Washington DC Office:2025 M Street,NW,Suite 800 I Washington,DC 20036 I Phone:202-367-1157 I wdma@wdma.com Chicago Office: 330 N.Wabash Avenue.,Suite 2000 1 Chicago,IL 606111 Phone:312-321-6802 1 www.wdma.com CLG 2'-11" PLAN 3/16"=1'-0" 19'-11" CLG 5'-5" STORAGE v 4 , Tom" RE9WE I � CLG 6'-6" CLOSET TOWN OF OUEENSSURY BUILDING&GODES 2 STE 3S DN 2'-4" RE ISED SECTION 1/4"=1'-0" N - 21411 -o a �aE�ARC �`as' o�oEkoy �'V 'DA Lo (O to (� 15'-0" OF " rl project/ Sheet Tm.E SECTION IN STORAGE UNDER THE ROOF 20-09 SK53 Date 3/16/22 st PRWECT STECIUK RESIDENCE- 2ND FLOOR EXTENSION Oldesign ��e AS NOTED Design ■ I. Not Scab for ConetrucNon