Loading...
AST-0226-2021 Office Use Only ACCESSORY STRUCTURE Permit#: ft5%-- b 2.2 6- 20 Z) PERMIT APPLICATION Permit Fee:$r pJ 8`— 742 Bay Road,Queensbury,NY 12804 Invoice#: lt) P:518-761-8256 www.gueensbury.net Flood Zone? Y N Reviewed By: Project Location: L4 Vick." �C'%V-C , 60CZA3' b'Jry. Tax Map ID#: 2 $9 1 1 Subdivision Name: PROJECT INFORMATION: U C E (] TYPE: ? Residential ❑ Commercial, Proposed Use: APR 13 2021 TOWN OF QUEENSBURY STRUCTURE: SUiLDINC®DES ❑ Boathouse(with or w/o sundeck) ❑ Canopy ❑ Carport ❑ Cell Tower ❑ Deck ❑ Detached Garage(>300 s.f.) ❑ Dock ❑ Gazebo Pavilion ❑ Pole Barn ❑ Porch ❑ Ramp ❑ Shed (<300 s.f.) ❑ Solar Panels(w/o rafter upgrades) ❑ 3-Season Porch ❑ Other: SQUARE FOOTAGE OF STRUCTURE: 1st floor: i 2nd floor: Total square feet: Brief description of scope.of project: �+✓ �� pay.�'�'` 1-�r' Dvc�ar 1Ca �-�1�� I ��g� Accessory Structure Application Revised January 2021 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction:$ 1 o 2. Are there any structures not shown on the plot plan? ❑YES ❑NO Explain: 3. Are there any easements on the property? ❑ YES �NO DEQLARAMON: 1.• I acknowledge that no construction shall be commenced-prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. k 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations. 5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: 4tll Lp,,MQIL SIGNATURE: �— 2-. DATE: Accessory Structure Application Revised January 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): 4"",� 1- pgrw Mailing Address, C/S/Z: JC4 6A anL '�Y ��'�`�`� Cell Phone: -5�,b - 744- C42-"- Land Line: Email: Ac-L e_ Con. • Primary Owner(s): S,Ni"t 4L 4.9 40?L:Z CAV4 Name(s): Mailing Address, C/S/Z: Cell Phone: Land Line: Email: ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contractor Name(s): �-�,. S�,�a, cta���� LL t Contractor Trade: Mailing Address, C/S/Z: n LD?w '7`7,'l aVv-o V4Ak Cell Phone: Land Line: Email: **Workers' Comp documentation must be submitted with this application** • Architect(s)/Eneineer(s): Business Name: Contact Name(s): ♦ -r,iJ: Zte ep>ac, j � Mailing Address, C/S/Z: -L v a, v R z , L,,4'. c-,6S Cell Phone: .5A P "' m 104 Land Line: Email: r,(1''' Z cn d--"V 61 Qo t. Contact Person for any questions regarding this project: . Cell Phone: Land Line: Email: Accessory Structure Application Revised January 2021 Deck and Roof Design checklist CtA.-rIs deck freestanding or attached\ (&,is Footing 1�4A, Sono tubes sized for posts_4X4 8" 6X612"Aldn Big foot or footing for roof load Y�--Sproper attachment to post and footing shown qA-Proper flashing or waterproofing to structure shown t✓%� Attachment to structure shown on plans Galvanized or Stainless Steel Bolts shown NO ZINC COATED Hex headed bolts NO CARRIDGE BOLTS j� Diagonal bracing shown for deck over 24" Floor joist parallel to carrying beams �I Deck post to beam attachment shown t Over 30" requires handrail Over 30" requires guards Over 30" required guards @ 34"to 38" in height and handrails @ 34"—38" i Me rsEWJMMCE- HAND ESTATES SUBDIVISION DAM APRIL 13.2005 LAST REVISED MAY 23.2005 BY YAN DUS N @ SIEVES LAND SURIVEWORS S86.50'42°E 106.85' 10 11 3 g 36,756.43 sq. ft. 0.82 acres - 60 ry9 - t�ry rye' POOL 2 STORY WOOD FRAMED HOUSE a CHA M11 LOF LC m t..cr _ a� 0 0 ASPHALT a DRIVE n i, ,,,.s 9a>i1°o 222.26' p�� g L� s1T•1�2°'" D � � pper� L ,� 0 1Y6 APR 13 2021 12 TOWN OF QUEENSBURY BUILDING&CODES ai SFPFEMIIER 113,Pont) Dub a vm®..nvm,mm.ua. Scaly 11=90' llep of a 3urYey mode for Q■IOtnIRYaO•IM Steves oui■®.■■o■.ems• 4 6 01 06 DRIVE COTS S—1 Jonathan La py�er Pi' 3 5102108 HOUSE/Poot LOCATION Land Sxxrveyors ""� '"="'� ":.�x� :■ m.= 2 4127106 HOUSE UNDER COMMUCDON CHM 1 W 1 100 RaeIIend Road queenebur,,New York 12804 pa.:w nam...,�MD Town of queenebury,Warren Count,Y, New York 1 10119105 REVISE HOUSE LOCATION LAP . ° ®iB 702-0474 New York Me. No. 50135 N0: DATE DESCRIPTION DWIL Na Oa3 _11 v , c Lacy T imber Fr' v��a 11�S, In C. wdega sytimberframes.com r ,.�,+'Fr�9 ''� 691 County Rd 70. Stillwater,NY 12170" (518)279-9108 fax: (5 1$) 81-9219 * legacytf@aol.col "JKkv build a house...when yogi can create a Legacy" PROPOSAL To: ion and Charlotre Lapper Re: 54 Grand View Dr, Queensbur3,NTY Date: March 16,2021 Scope of work: TIMBER FRAME: 12' x,18' pavilion: 8x10 posts (4), 6x8 posts(2) h 8x12 beams(1),8x10 beams(4) - D Lg: Q 2 4x6 knee braces(8) �S 6x truss (2) AP 6x10 rafters and collar tie p 212p 6x6 king post TOwN OF U�EE 6x12 hip rafters(4) BUILDING NSBURY CODES 4x8 hip jacks(10) 4xS common rafters (1 set) 4x12 header(1) 6x8 ridge(1) Based on drawings by Legacy dated 3/16/2021 Planed Eastern Hemlock timbers Octagonal oak pegs Traditional hand craned joinery "Timbers skim-planed or sanded at site prior to assembly Labor and materials to erect frame at site Crane rental, if easy access to site Delivery and unloading if ease-access to site Schedule: Approx. 15-18 weeks from authorization and receipt of deposit. ` 'e are experiencuig delays due to Covid,completion trill be at the eatliesr Possible date that material availability and schedule allows Proposal amount: Payment.• Deposit: $ Accepted: The above prices,speciticariot}s,and conditions are satisfactory and are hereby-accepted.You are authorized to do the work as specified.Payment will be made as outlined above. .Date of acceptance: f I BY: BY: / _ynnetn ',fitc cell,president,Legacy Timber frames Inc. ITimberlinx Page 1 of 1 A475 _y 4.75" Pipe. 'Half-connector' with one pin at one end • One slot with 7/8" internal thread at other end Overall length 4-3/4" • Pin hole center from end of timber =3-7/8" (when connecting post to concrete and post to steel) Pin hole center to center = 7-7/8" + exposed threaded rod (when you use two A475's + threaded rod to customize your own TIMBERLINX) Also available in stainless steel (A475SS) APPLICATIONS FOR A475 • Designed to customize any length of TIMBERLINX you require • Concealed hold-down, wood to concrete • (A475 attached to 7/8" concrete expansion anchor) • Join wood to steel • (A475 attached to 7/8" threaded rod with 7/8" nut and washer) • Customers are discovering new uses for A475 every day Email Us info@timberlinx.com http://timberlinx.com/cat—a475.html 4/16/2021