AST-0226-2021 Office Use Only
ACCESSORY STRUCTURE Permit#: ft5%-- b 2.2 6- 20 Z)
PERMIT APPLICATION Permit Fee:$r pJ 8`—
742 Bay Road,Queensbury,NY 12804 Invoice#: lt)
P:518-761-8256 www.gueensbury.net Flood Zone? Y N Reviewed By:
Project Location: L4 Vick." �C'%V-C , 60CZA3' b'Jry.
Tax Map ID#: 2 $9 1 1 Subdivision Name:
PROJECT INFORMATION: U C E (]
TYPE: ? Residential ❑ Commercial, Proposed Use: APR 13 2021
TOWN OF QUEENSBURY
STRUCTURE: SUiLDINC®DES
❑ Boathouse(with or w/o sundeck) ❑ Canopy ❑ Carport ❑ Cell Tower ❑ Deck
❑ Detached Garage(>300 s.f.) ❑ Dock ❑ Gazebo Pavilion ❑ Pole Barn ❑ Porch ❑ Ramp
❑ Shed (<300 s.f.) ❑ Solar Panels(w/o rafter upgrades) ❑ 3-Season Porch ❑ Other:
SQUARE FOOTAGE OF STRUCTURE:
1st floor: i
2nd floor:
Total square feet:
Brief description of scope.of project: �+✓ �� pay.�'�'` 1-�r' Dvc�ar 1Ca �-�1�� I ��g�
Accessory Structure Application Revised January 2021
ADDITIONAL PROJECT INFORMATION:
1. Estimated Cost of Construction:$ 1 o
2. Are there any structures not shown on the plot plan? ❑YES ❑NO Explain:
3. Are there any easements on the property? ❑ YES �NO
DEQLARAMON:
1.• I acknowledge that no construction shall be commenced-prior to the issuance of a valid permit and will be
completed within a 12 month period.Any changes to the approved plans prior to/during construction will require
the submittal of amended plans,additional reviews and re-approval.
k
2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of
Queensbury.After 1 year from the initial application date, 100%of the fee is retained.
3. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees
and department approval.
4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or description
of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building laws
and ordinances, and in conformance with local zoning regulations.
5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of
occupancy.
6. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above:
PRINT NAME: 4tll Lp,,MQIL
SIGNATURE: �— 2-. DATE:
Accessory Structure Application Revised January 2021
CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL
• Applicant:
Name(s): 4"",� 1- pgrw
Mailing Address, C/S/Z: JC4 6A anL '�Y ��'�`�`�
Cell Phone: -5�,b - 744- C42-"- Land Line:
Email: Ac-L e_ Con.
• Primary Owner(s): S,Ni"t 4L 4.9 40?L:Z CAV4
Name(s):
Mailing Address, C/S/Z:
Cell Phone: Land Line:
Email:
❑ Check if all work will be performed by property owner only
• Contractor(s): (List all additional contractors on the back of this form)
Contractor Name(s): �-�,. S�,�a, cta���� LL t
Contractor Trade:
Mailing Address, C/S/Z: n LD?w '7`7,'l aVv-o V4Ak
Cell Phone: Land Line:
Email:
**Workers' Comp documentation must be submitted with this application**
• Architect(s)/Eneineer(s):
Business Name:
Contact Name(s): ♦ -r,iJ: Zte ep>ac, j �
Mailing Address, C/S/Z: -L v a, v R z , L,,4'. c-,6S
Cell Phone: .5A P "' m 104 Land Line:
Email: r,(1''' Z cn d--"V 61 Qo t.
Contact Person for any questions regarding this project: .
Cell Phone: Land Line:
Email:
Accessory Structure Application Revised January 2021
Deck and Roof Design checklist
CtA.-rIs deck freestanding or attached\
(&,is Footing
1�4A, Sono tubes sized for posts_4X4 8" 6X612"Aldn
Big foot or footing for roof load
Y�--Sproper attachment to post and footing shown
qA-Proper flashing or waterproofing to structure shown
t✓%� Attachment to structure shown on plans
Galvanized or Stainless Steel Bolts shown NO ZINC COATED
Hex headed bolts NO CARRIDGE BOLTS
j� Diagonal bracing shown for deck over 24"
Floor joist parallel to carrying beams
�I Deck post to beam attachment shown
t Over 30" requires handrail
Over 30" requires guards
Over 30" required guards @ 34"to 38" in height and handrails @ 34"—38"
i
Me rsEWJMMCE-
HAND ESTATES SUBDIVISION
DAM APRIL 13.2005
LAST REVISED MAY 23.2005
BY YAN DUS N @ SIEVES
LAND SURIVEWORS
S86.50'42°E
106.85'
10
11 3 g
36,756.43 sq. ft.
0.82 acres
- 60 ry9 -
t�ry rye' POOL
2 STORY
WOOD FRAMED
HOUSE a CHA M11 LOF
LC
m
t..cr _ a�
0
0
ASPHALT a
DRIVE
n i,
,,,.s
9a>i1°o 222.26' p�� g L�
s1T•1�2°'" D � � pper�
L ,� 0 1Y6
APR 13 2021
12 TOWN OF QUEENSBURY
BUILDING&CODES
ai SFPFEMIIER 113,Pont)
Dub a
vm®..nvm,mm.ua. Scaly 11=90'
llep of a 3urYey mode for
Q■IOtnIRYaO•IM
Steves
oui■®.■■o■.ems• 4 6 01 06 DRIVE COTS S—1
Jonathan La py�er
Pi' 3 5102108 HOUSE/Poot LOCATION
Land Sxxrveyors ""� '"="'�
":.�x� :■ m.= 2 4127106 HOUSE UNDER COMMUCDON CHM 1 W 1
100 RaeIIend Road queenebur,,New York 12804 pa.:w nam...,�MD Town of queenebury,Warren Count,Y, New York 1 10119105 REVISE HOUSE LOCATION
LAP .
° ®iB 702-0474 New York Me. No. 50135 N0: DATE DESCRIPTION DWIL Na Oa3 _11
v ,
c
Lacy T imber Fr' v��a 11�S, In C. wdega sytimberframes.com
r ,.�,+'Fr�9
''� 691 County Rd 70. Stillwater,NY 12170" (518)279-9108 fax: (5 1$) 81-9219 * legacytf@aol.col
"JKkv build a house...when yogi can create a Legacy"
PROPOSAL
To: ion and Charlotre Lapper
Re: 54 Grand View Dr, Queensbur3,NTY
Date: March 16,2021
Scope of work:
TIMBER FRAME:
12' x,18' pavilion:
8x10 posts (4), 6x8 posts(2) h
8x12 beams(1),8x10 beams(4) - D Lg: Q 2
4x6 knee braces(8) �S
6x truss (2) AP
6x10 rafters and collar tie p 212p
6x6 king post TOwN OF U�EE
6x12 hip rafters(4) BUILDING NSBURY
CODES 4x8 hip jacks(10)
4xS common rafters (1 set)
4x12 header(1)
6x8 ridge(1)
Based on drawings by Legacy dated 3/16/2021
Planed Eastern Hemlock timbers
Octagonal oak pegs
Traditional hand craned joinery
"Timbers skim-planed or sanded at site prior to assembly
Labor and materials to erect frame at site
Crane rental, if easy access to site
Delivery and unloading if ease-access to site
Schedule:
Approx. 15-18 weeks from authorization and receipt of deposit.
` 'e are experiencuig delays due to Covid,completion trill be at the eatliesr Possible date
that material availability and schedule allows
Proposal amount:
Payment.•
Deposit: $
Accepted:
The above prices,speciticariot}s,and conditions are satisfactory and are hereby-accepted.You are
authorized to do the work as specified.Payment will be made as outlined above.
.Date of acceptance: f I
BY:
BY: /
_ynnetn ',fitc cell,president,Legacy Timber frames Inc.
ITimberlinx Page 1 of 1
A475
_y
4.75" Pipe. 'Half-connector' with one pin at one end
• One slot with 7/8" internal thread at other end
Overall length 4-3/4"
• Pin hole center from end of timber =3-7/8"
(when connecting post to concrete and post to steel)
Pin hole center to center = 7-7/8" + exposed threaded rod (when
you use two A475's + threaded rod to customize your own
TIMBERLINX)
Also available in stainless steel (A475SS)
APPLICATIONS FOR A475
• Designed to customize any length of TIMBERLINX you require
• Concealed hold-down, wood to concrete
• (A475 attached to 7/8" concrete expansion anchor)
• Join wood to steel
• (A475 attached to 7/8" threaded rod with 7/8" nut and washer)
• Customers are discovering new uses for A475 every day
Email Us info@timberlinx.com
http://timberlinx.com/cat—a475.html 4/16/2021