Loading...
Narrative Structural Civil Municipal DANIEL W. RYAN P.E. Licensed Professional Engineer P.O. Box 596 • Glens Falls, NY • 12801 • (518) 792-9264 www.dwrpe.com Town of Queensbury December 15, 2021 742 Bay Road Queensbury, NY 12804 Attn: Laura Moore, Town Planner RE: Patrick M. Connors – 95 Rockhurst Road Existing Non-Conforming Deck Repair/Reconstruction Project DWRPE represents the above Applicant regarding required project-related Town approvals. More specifically, the Applicant is planning to perform repairs to an existing boathouse and an attached deck structure at the rear and side of the existing dwelling. In accordance with Zoning Section 179-13-010 (F) reconstruction of an existing non-conforming structure requires an area variance, and the zoning administrator has referred this project to the Planning Board for site plan review. Since the project includes removal of the existing attached deck structure in its entirety, this work has been classified as new construction, reconstruction, or replacement, rather than repairs. The intent of the project is simply to remove deteriorated elements of the deck and boathouse, then to replace those deteriorated components in-kind to match the existing conditions and configuration. The boathouse will receive a replacement roof, upper deck, new railings/guards, and new access stairs. The rear attached elevated deck will be removed entirely and replaced with new posts, structural framing, decking, railings/guards, and access stairs. No modifications are proposed for either structure as the intent is to maintain the existing structures with replacement components as deemed necessary. In addition, due to significant settlement of existing deck components resulting from inadequate foundations and/or piers, several deck column foundation elements (sonotube piers) will be replaced. No site work or site modifications are proposed. The boathouse will receive new components to replace deteriorated elements of the structure to address long overdue maintenance. The attached deck will be removed and reconstructed in-kind, to match existing conditions. Only very minor land disturbance will occur as a result of the project at several sonotube piers supporting deck posts that have settled and require replacement. The balance of the deck structure is supported on an existing concrete mat slab to remain. Because no site changes or deck or boathouse alterations, expansion, or reconfiguration are proposed, waivers are requested regarding the following application submission requirements since the project is residential in nature and considered in-kind replacement or repairs;  Existing Site Plan with Water/Sewer/Utility/Grading Information  Erosion and Sediment Control  Lighting Specifications  Boundary or Topographic Survey (existing boundary survey is included without topography)  Landscaping Specifications  Architectural Floor Plans and Elevations  Drainage and/or Stormwater Management Due to the nature of the application in that it is residential and falls within the definition of a Type II SEQRA Action (617.5(c)(1), 617.5(c)(2), & 617.5(c)(17)), from the perspective of SEQRA the project is believed to be exempt from review relative to the potential for resulting adverse impacts. Enclosed please find the following documents in support of the project and area variance application; 1. Site Plan Review Application 2. Owner/Applicant Authorizations P.O. Box 596 • Glens Falls, NY • 12801 • (518) 792-9264 www.dwrpe.com 3.Deed 4.Existing Boundary Survey & Sewage Utility Plan 5.Property Photos 6.Existing Deck Measurement Schematic 7.Deck/Boathouse Repair and Reconstruction Drawings We request that the Application, if deemed complete, be placed upon the upcoming Planning Board agendas for the January 2022 meeting dates if possible. Upon your initial review of the documentation, please contact me at your earliest convenience if you have any questions or require additional information. Sincerely, Daniel W. Ryan, P.E.