2003-330 TOWN OF QUEENSBURY
742 BayRoad,Qaeensbury,NY 12804 5902 (518)761-8201
Community Development-Building&Codes (518)161.8256
U a I IFICATE Ur 'C'OMPLIANur,
PermitNumber. P20030330 Date Issued; Thursday, July 19,2007
This is to certify that work requested to be done as shown by Permit Number. P20030330
has been completed.
Tax Map Number. 523400-301-014-0001-024-000-0000
Location. 12 PHEASANT Walk
Owner. JOY MOSSEAU
Applicant. JOY MOSSEAU
This structure may be occupied as a.
Porch&Deck
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
Porch, Deck, Dock, or Boathouse Permit Application
Town of Queensbury—Dept of Community Development, 742 Bay Road, Queensbury,NY
(518)761-8256
A permit must be obtained before beginning construction. No Permit File _
inspection will be made until applicant has received a valid Fee Paid
building permit. All applicants' spaces on this application must be
completed and must appear on the application for Reviewed
m y:
(/l
Applicant: 5'G - ,/L�c� ,;�r;�cJ� Owner:_ BQUF R
Address: ,P.S �5: Address:
lcc-Ei0`' �itr.c.S �vy �a•aaJ v. ..+✓�- sc
Phone#(S-191 )-,6:3 - 3 Phone#( )
Email Address: Email Address:
Person Responsible for Supervision of Work as Regards to Building Codes-
Name J`�vrT Address: / 7r' teJ-.Id Phone
601-1-y
Property Location: Lot Number;_ 1 House Number A&----
Subdivision Name: t it-n J; f c1c Tax Map Number:
Estimated Market Value of Construction: $ ✓'�2�60
o Porch
I. Deck 0/SG e."--cs 1.-t Rics-f
0 Dock
❑ Boathouse
a Other work(describe
Size of structure to be built "O�-6 square feet �Sb
Submit along with this application:'
1. Two plot plans drawn to scale,preferably using a survey map. Indicate proposed
structure showing setback dimensions from all property lines. Show location of
water supply and location and configuration of septic disposal area.
2. Two sets of structural drawings.' Indicate size of posts or studs, floor j oists,
decking or flooring material to be used. Show how the porch or deck will be
fastened to the building. If a roof will be constructed, indicate the size of posts or
studs,roof rafter spacing and span. Indicate type of roof- sloped, flat, shed,or
other. Indicate the type of material being used for the roof.
Declaration: please sign below after you have carefully read the statement:
To the best of my knowledge the statements contained in this application,together with the plans and
specifications submitted,are a true and complete statement of all proposed work to be done on the
described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws
pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is
authorized by the owner.
Applicant's signature: Date: 3y------------
L:\SueHezningevayV3uilding.Permit.FORMS\Porch.Porch.Permit.doc 8/13/02 revised per 131-1
a " .
Queensbury Building & Code Enforcement - Residential Final Inspection
.86e No.(518)761-8256 Arrive: arU)
apart: _am/pm
Date Inspection request received; Inspector's Initials:
NAME: PERMIT#:
LOCATION: VA DATE:
TYPE OF STRUCTURE:
Comments
Yes No N/A
Buildiniz Number I Address visible from road � J �
ChimneyB Height/' "Vent/Direct Vent Location l
Fresh Aar Intake
3 inch Plumbing Vent tlzrou h roof minimum 6 inches 00
Roof Com late/Exterior Finish Com late
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 'inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade 24I2. j
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight -
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors: `
Every level: ; Every Bedroom: G, !L-
/
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, I s .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures i
Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum l2"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Gara a fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain CgAiftaftn,if required
okay to iss C/C C/0 Temporary/Permanent
L:1Building&Codes FormslBuilding&Codes\Inspection FormslResidential Final Inspection Form—revised-1 00405.doc
Framing / Firestoppin, g Inspection Report
Office No. (518) 761-8256 Date Inspection req t r ei ed: (e)/
Queensbury Building&Code Enforcement Arrive: —a epart.
742 Bay Road, Queensbury,NY 12804 Inspector's Initi s-
NAME: PERMIT#: c;?(ID 3
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y i N N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
I V2 (w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2,3 hour
Fire wall 2, 3, 4 hour
Firestopping L
Penetration sealed
16 inch insulation in cavity mi/
Garage Fire Separation
House side V2 inch or 5/8 in/Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/belo7grade
5.0 sf grade
LAS ueHerning,,vay\13ui I din,-.Codes.Inspection.FORM S\Frarni ng Firestopping Inspection Report.doc January 28,2003
60
Framing / Firestopping Inspection Report All
Office No. (518) 761-8256 Date Inspection request received:
m/p
Queensbury Building&Code Enforcement Arrive:
Inspector's Ini—'It— V
742 Bay Road, Queensbury,NY 12804 Initials:
mart:
V
NAME: 0 ssee-iA- PERMIT#:
LOCATION: Q INSPECT ON:
TYPE OF STRUCTURE:
ram Y N N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 V2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from w
Fire separation 1, 2, 3 hour'
Fire wall 2, 3,4 hour
Firestopping
z
Penetration sealed
16 inch insulation/cuavity min.
Garage Fire S eara on
House side PV2 ' ch or 5/8 inch Type X
Garage sid /8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above below grade
5.0 sf grade
LASuel-lerningway\13 ui Iding.Codes.Inspection.FORNISTrarni n Firestopping Inspection Report.doc January 28,2003
W
Foundation Inspection Report
r
p �
Office No. (51S)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p Depart- m/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT#: C,�
LOCATION: } INSPECT ON:
TYPE OF STRY7C
Comments
Y N N/A
ings
Piers
Mo olithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Walipour
Reinforcement in Place
s
Foundation Dampproofmg
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Glade 6 inch drop within 10 ft.
L;\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003